E-CA-S32A [ACCRETECH]
SURFCOM · CONTOURECORD Option;型号: | E-CA-S32A |
厂家: | ACCRETECH |
描述: | SURFCOM · CONTOURECORD Option |
文件: | 总20页 (文件大小:3633K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Surface Texture – Contour
Measuring Instruments
SURFCOM · CONTOURECORD Option
Nose Piece
Applicable models S1500
S1900
S1910
S2900
S-NEX001
Measuring application
Model
External view
Applicable stylus
Skid shape
-
Remarks
Skidless
• Front travel adjustment with
adjustment screw
DM44026
All
• E-DT-SS01A pickup use only
Applicable models
FLEX-50
S130
S480
S1400
S1800
S2800
Measuring application
Model
External view
Applicable stylus
Skid shape
Remarks
General
010 2501
DM43801
• Tip skid
• Standard pickup built in
010 2701
32 mmR sapphire
purpose
Skidless
9.1
4
• For protection
• For front travel adjustment
010 2702*
010 2703*
All styluses
-
Horizontal
tracing of
ordinary planes
• Double sided straddling skid
• Skid radius for horizontal
tracking: 4.5 mm
010 2501
DM43801
9.1
8.4
1
4.8
• Double sided straddling skid
• Position adjustment with stylus
required
010 2511
DM43811
Extra fine holes 010 2704
8 mmR tool steel
8 mmR tool steel
8 mmR tool steel
32 mmR sapphire
32 mmR sapphire
32 mmR sapphire
0.8 mmR ruby
1.8
17.2
010 2512
DM43812
Fine holes
010 2705
010 2706
010 2707
010 2708
010 2709*
010 2710*
010 2711
010 2722*
010 2723
010 2724
010 2726
• Tip skid
4.5
5.2
Thin groove
tooth surfaces
010 2512
DM43812
• Double sided straddling skid
Curved sur-
faces
010 2515
DM43815
20.3
• Sliding skid
12
010 2515
DM43815
Deep grooves
20.3
• Double sided straddling skid
Narrow
deep grooves
010 2515
DM43815
• Tip skid
20.3
• One sided straddling skid
• Magnification: 5,000 or more
• Position adjustment with stylus
required
010 2515
DM43815
R grooves
2.5
1.5
• Recording only
• Double sided straddling skid
• Skid position adjustment
required
• Three types of skids provided
for Φ 2 to 4,Φ 4 to 8, Φ 8 to 16
Small round
bars
010 2501
DM43801
32 mmR sapphire
32 mmR sapphire
32 mmR sapphire
32 mmR sapphire
0.8 mmR ruby
5.5
4
010 2522
DM43822
Long holes
• Tip skid
7.2
• Tip skid
• Position adjustment with stylus
required
Deep grooves
in holes
010 2525
DM43825
6
• Double sided straddling skid
• Position adjustment with stylus
required
Extra
deep grooves
010 2526
DM43826
63.5
• Double sided straddling skid
• Magnification: 5,000 or more
• Position adjustment with stylus
required
Bottom surface
of O-ring
010 2525
DM43825
grooves
* Indicates stylus/nose piece set DM43800 and 010 2640
Standard Inventory Parts
81
TOKYO SEIMITSU
Surface Texture – Contour
Measuring Instruments
SURFCOM · CONTOURECORD Option
Replaceable Roughness Profile Measuring Styli (Tip Radius 2 μm)
Applicable models
FLEX-50
Model
S130
S1400
S1500
S1900
S1910
S480
S1800
S2800
S2900
S-NEX001
Measuring application
General purpose
External view
Specifications
Remarks
2 μmR,
• All orientations
DM43801
DM43802
60° conical diamond,
0.75 mN
• Horizontal tracing possible
• Standard accessory
Fine wires,
knife edges
2 μmR,
60° knife edge-shaped
diamond,
• All orientations
0.75 mN
ø1.2
ø2.7
Medium fine holes
2 μmR,
60° conical diamond,
0.75 mN
2.6
• All orientations
• Horizontal tracing possible
DM43809
DM43811
DM43812*
15
(4.8)
33.5
5.7
(0.7)
Extra fine holes,
gear flank
2 μmR,
60° conical diamond,
0.75 mN
• All orientations
• Horizontal tracing possible
4.8
Fine holes/
thin grooves
2 μmR,
60° conical diamond,
0.75 mN
• All orientations
• Horizontal tracing possible
Hole bottom/conical
surfaces
2 μmR,
60° conical diamond,
0.75 mN
• All orientations
• Horizontal tracing possible
DM43813
DM43814*
Corners/
tooth surfaces
2 μmR,
60° conical diamond,
0.75 mN
• All orientations
• Horizontal tracing possible
Deep grooves/
round grooves
2 μmR,
• Downward measurement
• Large waveform distortion
DM43815*
60° conical diamond,
0.8 mN
Fine long holes
• Downward measurement
• Sensitivity: 1/2
• Magnification: x5000
• Large waveform distortion
2 μmR,
60° conical diamond,
3 mN
DM43821
DM43822*
DM43824
Low magnification,
long holes
2 μmR,
60° conical diamond,
3 mN
• Downward measurement
• Sensitivity: 1/2
• Magnification: x20000
Low magnification,
corners
2 μmR,
60° conical diamond,
4 mN
• Downward measurement
• Sensitivity: 1/2
• Magnification: x20000
Deep groove
corners
2 μmR,
60° conical diamond,
4 mN
• Downward measurement
• Sensitivity: 1/2
• Magnification: x10000
DM43827
DM43825
Deep hole grooves,
O-ring groove bottom
surfaces
• Downward measurement
• Sensitivity: 1/2
• Magnification: x20000
• Large waveform distortion
2 μmR,
60° conical diamond,
3.4 mN
Extra deep
grooves
• Downward measurement
• Sensitivity: 1/2
• Magnification: x5000
• Large waveform distortion
2 μmR,
60° conical diamond,
4 mN
DM43826
DM43800
Nosepiece
010 2702, 010 2703, 010 2709,
010 2710, 010 2722
Stylus
DM43812, DM43814,
DM43815, DM43822
2 μmR
2 μmR
Stylus set
E-DT-SS01A pickup use only
Nosepiece DM44026
Stylus
DM43801, DM43811,
DM43812, DM43814,
DM43815, DM43822
DM43900
* Indicates stylus/nose piece set DM43800. The value of measuring force is when E-DT-S03A/E-DT-SE19A are mounted.
Standard Inventory Parts
82
TOKYO SEIMITSU
Replaceable Roughness Profile Measuring Styli (Tip Radius 5 μm)
Applicable models
FLEX-50
Model
S130
S1400
S1500
S1900
S1910
S480
S1800
S2800
S2900
S-NEX001
Measuring application
General purpose
External view
Specifications
Remarks
5 μmR,
90°conical diamond,
• All orientations
010 2501
• Horizontal tracing possible
• All orientations
4 mN
Fine wires,
knife edges
5 μmR,
90°knife edge-shaped
diamond, 5 mN
010 2502
Medium fine
holes
5 μmR,
• All orientations
• Horizontal tracing possible
010 2509
010 2511
010 2512*
010 2513
010 2514*
90°conical diamond,
4 mN
15
Extra fine holes,
gear flank
5 μmR,
90°conical diamond,
4 mN
• All orientations
• Horizontal tracing possible
0.5
Fine holes/
thin grooves
5 μmR,
90°conical diamond,
4 mN
• All orientations
• Horizontal tracing possible
Hole bottom/
conical surfaces
75°
5 μmR,
90°conical diamond,
4 mN
• All orientations
• Horizontal tracing possible
6.1
Corners/
tooth surfaces
5 μmR,
60°conical diamond,
4 mN
• All orientations
• Horizontal tracing possible
Deep grooves/
round grooves
5 μmR,
90°conical diamond,
5 mN
• Downward measurement
• Large waveform distortion
010 2515*
Gear tooth
profiles,
thread flank
5 μmR,
90°conical diamond,
4 mN
7
010 2518
• Magnification: x10000
Fine long holes
• Downward measurement
• Sensitivity: 1/2
• Magnification: x5000
• Large waveform distortion
5 μmR,
90°conical diamond,
5 mN
010 2521
010 2522*
010 2524
010 2527
40.7
Low magnification,
long holes
5 μmR,
90°conical diamond,
5 mN
• Downward measurement
• Sensitivity: 1/2
• Magnification: x20000
Low magnification,
corners
5 μmR,
60°conical diamond,
5 mN
• Downward measurement
• Sensitivity: 1/2
• Magnification: x20000
Deep groove
corners
• Downward measurement
• Sensitivity: 1/2
• Magnification: x10000
• Large waveform distortion
5 μmR,
60°conical diamond,
8 mN
Nosepiece
010 2702, 010 2703, 010 2709,
010 2710, 010 2722
Stylus
5 μmR
Stylus set
010 2640
010 2512, 010 2514,
010 2515, 010 2522
* Indicates stylus/nose piece set 010 2640. The value of measuring force is when E-DT-S01A/E-DT-SE18A are mounted
Standard Inventory Parts
83
TOKYO SEIMITSU
Surface Texture – Contour
Measuring Instruments
SURFCOM · CONTOURECORD Option
Replaceable Roughness Profile Measuring Styli
Applicable models
FLEX-50
Model
S130
S1400
S1500
S1900
S1910
S480
S1800
S2800
S2900
S-NEX001
Measuring application
External view
Specifications
Remarks
Soft materials
• All orientations
10 μmR,
90° conical diamond,
0.75 mN
• Horizontal tracing possible
• Specifications are for when
E-DT-S02A is mounted
010 2508
Deep hole grooves,
bottom surface of
Oring groove
• Downward measurements
• Sensitivity: 1/2
• Magnification: x20000
• Large waveform distortion
10 μmR,
90° conical diamond,
8 mN
010 2525
Extra deep grooves
• Downward measurements
• Sensitivity: 1/2
• Magnification: x5000
• Large waveform distortion
10 μmR,
90° conical diamond,
8 mN
010 2526
Bottom surface
of holes
• Magnification: x5000
• Large waveform distortion
• Dedicated connecting rod
used
5 μmR,
90° conical diamond,
8 mN
010 2541
High
magnification
measurement
• All orientations
1 μmR,
60° conical diamond,
0.75 mN
• Horizontal tracing possible
• Specifications are for when
E-DT-S04A is mounted.
010 2506
010 2528
High
magnification
contour profiles
• Downward measurements
• Sensitivity: 1/2
• Magnification: x10000
• For E-DT-S01A, -S03A
1 μmR,
60° conical diamond,
8 mN
* The value of measuring force is when E-DT-S01A/E-DT-SE18A are mounted
Standard Inventory Parts
Replaceable Waviness Profile Measuring Styli
Applicable models
FLEX-50
Model
S130
S1400
S1500
S1900
S1910
S480
S1800
S2800
S2900
S-NEX001
Measuring application
External view
Specifications
Remarks
Steps
250 μmR,
60° conical saphire,
7.2
010 2504
• All orientations
5 mN
Waviness
Φ 1.6, ruby,
4 mN
7.2
010 2505
010 2510
010 2520
010 2523
• All orientations
• All orientations
• Magnification: x5000
• Excluding E-DT-S03A/
-SS01A/SE19A
Extra fine hole
profiles
0.29
Φ 0.5, tool steel,
4 mN
Fine long hole
waviness
• Downward measuring
• Sensitivity: 1/2
• Magnification: x10000
Φ 1.6, ruby,
5 mN
Large steps
• Downward measuring
• Sensitivity: 1/2
• Magnification: x25000
250 μmR, sapphire,
5 mN
7.2
* The value of measuring force is when E-DT-S01A/E-DT-SE18A are mounted
Standard Inventory Parts
84
TOKYO SEIMITSU
Pickups
Applicable models
FLEX-50
S130
S1400
S1500
S1900
S1910
S480
S1800
S2800
S2900
Measuring application
Model
External view
Specifications
Remarks
• All orientations
• Horizontal tracing possible
2 μmR,
60° conical diamond,
0.75 mN
Low measuring
force
•
Provided as standard S1500, S1900, S1910, S2900,
E-DT-SS01A
S-NEX001 (Specialized for Linear/NEX Series)
• With DM43801 stylus
5 μmR,
• All orientations
90° conical diamond,
4 mN
• Horizontal tracing possible
• With 0102501 stylus
General purpose E-DT-SS08A
General purpose
For S1500, S1900, and S2900 DX/SD types
• All orientations
• Horizontal tracing possible
• With 0102501 stylus
5 μmR,
90° conical diamond,
4 mN
E-DT-S01A
E-DT-SE18A
• E-DT-SE18A: for S130A/S-FLEX50A
Soft materials
E-DT-S02A
10 μmR,
90° conical diamond,
0.75 mN
• All orientations
• Horizontal tracing possible
• With 0102508 stylus
Low measuring
force
• All orientations
2 μmR,
60° conical diamond,
0.75 mN
• Horizontal tracing possible
• Standard specifications
• With DM43801 stylus
E-DT-S03A
E-DT-SE19A
9.1
• E-DT-SE19A: for S130A/S-FLEX50A
High magnification
1 μmR,
• All orientations
60° conical diamond,
0.75 mN
• Horizontal tracing possible
• With 0102506 stylus
E-DT-S04A
Non-continuous
measurement
• All orientations
5 μmR,
90° conical diamond,
4 mN
• Horizontal tracing possible
• Front travel: 110 to 120 μm
• Other specifications are same as for
E-DT-S01A
E-DT-S05A
Grooves in holes
• Skidless measurement only
• Max. magnification: x10000
• Dedicated connecting rod required
(010 2746)
5 μmR,
90° conical diamond,
4 mN
E-DT-S06A
• With 0102542 dedicated stylus
Ultra deep
5 μmR,
grooves
90° conical diamond,
5 mN
E-DT-S07A
• Stylus can not be replaced
• Max. magnification: x10000
• Sensitivity: 1/2
2 μmR,
60° conical diamond,
4 mN
• Large waveform distortion
E-DT-S122A
Ultra long holes
5 μmR,
90° conical diamond,4 mN
E-DT-S08A
E-DT-S137A
• Stylus can not be replaced
• Max. magnification: x5000
• Sensitivity: 1/5
2 μmR,
60° conical diamond,4 mN
High magnification
• Max. magnification: x500000
• Measuring force:0.2 mN
• With 016 2854 stylus
E-DT-SH01A
1 μmR, 90° conical diamond • Included with E-DT-SA01A as standard
1 μmR, 60° conical diamond
0162854
010 2567
010 2210
010 2211
010 2212
10 μmR, 60° conical diamond
Stylus for
E-DT-SH01A
5 μmR, 60° conical diamond
0.5 μmR, 60° conical diamond
0.5 μmR, 90° 2.5 μm width
knife edge, diamond
010 2213
23
5 μmR,
90° conical diamond
10 mN,
• With 0102501 dedicated stylus
DM42001: for S1400, S1800, S2800
DM42011: for S480
DM42001
DM42011
DM42012
Thin pickup
horizontal tracing possible
Max. magnification: x5000 or less • DM42020: for Linear Series/NEX Series
DM42012: for models preceding S590A
• Used for horizontal tracing of
crankshaft pins, journals,
or other such parts.
Pickup holder
for thin pickup
E-DH-S60A
E-DT-SL12B
123.6
Measuring range: 300 μm
Spot diameter: 2 μm
Work distance: 4.5 mm
• Color confocal point type
• Light source: Halogen light bulb
• Life: 1000h
Non-contact
measurement
Standard Inventory Parts
85
TOKYO SEIMITSU
Surface Texture – Contour
Measuring Instruments
SURFCOM · CONTOURECORD Option
Replaceable Styli for S5000DX/S3000/SNEX
Applicable models
Name
S5000DX/SD
S3000A
SNEX100
Model
External view
Specifications
Remarks
• Stroke: 13 mm (S5000)
12mm (S3000)
5mm (S-NEX 100)
• For roughness and contour
measurement
2 μmR,
60° conical diamond,
0.75 mN
DM48505
General purpose
• Stroke: 13 mm (S5000)
12mm (S3000)
5mm (S-NEX 100)
• For roughness and contour
measurement
• S5000DX/SD standard
accessory
2 μmR,
60° conical diamond,
0.75 mN
General purpose
highly rigid
stylus
DM84071
(Old model: DM48507)
• Stroke: 26 mm (S5000)
24mm (S3000)
10mm (S-NEX 100)
• For contour measurement
only
Highly rigid sty-
lus for contours
2X arm
Φ 1 ruby ball,
0.75 mN
DM48508
DM48509
DM48511
DM48742
DM48513*1
DM48514
DM48515
DM48588
DM48774
• Stroke: 32.5 mm (S5000)
30mm (S3000)
12.5mm (S-NEX 100)
• For contour measurement
only
Highly rigid sty-
lus for contours
2.5X arm
Φ 1 ruby ball,
3.2 mN
• Stroke: 13 mm (S5000)
12mm (S3000)
5mm (S-NEX 100)
• For roughness and contour
measurement
2 μmR,
60° conical diamond,
0.75 mN
Offset measure-
ment stylus
• Stroke: 26 mm (S5000)
24mm (S3000)
10mm (S-NEX 100)
• For contour measurement
only
25 μmR,
24° conical carbide,
4 mN or less
Offset measure-
ment stylus
2X arm
• Stroke: 13 mm (S5000)
12mm (S3000)
5mm (S-NEX 100)
• For roughness and contour
measurement
2 μmR,
60° conical diamond,
0.75 mN
Small hole stylus
• Stroke: 13 mm (S5000)
12mm (S3000)
5mm (S-NEX 100)
• For roughness and contour
measurement
2 μmR,
60° conical diamond,
0.75 mN
Extra small hole
stylus
• Stroke: 13 mm (S5000)
12mm (S3000)
5mm (S-NEX 100)
• For roughness and contour
measurement
2 μmR,
60° conical diamond,
0.75 mN
Deep hole stylus
• Stroke: 13 mm (S5000)
12mm (S3000)
5mm (S-NEX 100)
• For roughness and contour
measurement
5 μmR,
30° conical diamond,
0.75 mN
Stylus for
fine contours
• Stroke: 13 mm (S5000)
12mm (S3000)
5mm (S-NEX 100)
• For roughness and contour
measurement
2 μmR,
60° knife edge-shaped
diamond,
Stylus for ridge/
tooth tip mea-
surement
0.75 mN
2 or less
*1 Requires master ball calibration unit for small holes. *Special stylus will be studied and proposed in accordance with customer’s workpieces.
Standard Inventory Parts
86
TOKYO SEIMITSU
Replaceable Styli for S2000DX/SD
Applicable models
Name
S2000DX/SD
Model
External view
Specifications
2 μmR,
60° conical diamond,
0.75 mN
5 μmR,
30° conical diamond,
0.75 mN
5 μmR,
40° conical diamond,
4 mN
Remarks
• Standard accessory
• Stroke: 5 mm
• For roughness and contour measurement
DM47501
General purpose DM47508
DM47548
• Stroke: 5 mm
• For roughness and contour
measurement
• Stroke: 5 mm
• For roughness and contour
measurement
LH=65, LV=−14.35
25 μmR,
24° conical carbide,
5 mN
• Standard accessory
• Stroke: 10 mm
LH=130,
LV=−21.5
DM47513
•
For contour measurement only
138.5
Contour stylus
2X arm
25 μmR,
12° inclined carbide,
7 mN or less
• Stroke: 10 mm
For contour measurement only
LH=130,
LV=−21.5
DM47525
•
• Stroke: 5 mm
2 μmR,
60° conical diamond,
0.75 mN
Offset measure-
DM47504
LH=65,
LV=−14.5
• Offset: 13.5 mm
• For roughness and contour
measurement
ment stylus
2 μmR,
60° conical diamond,
0.75 mN
• Stroke: 5 mm
• For roughness and contour
measurement
DM47505*1
LH=65,
LV=−5.025
Small hole stylus
2 μmR,
• Stroke: 5 mm
DM47524
60° conical diamond,
0.75 mN
• For roughness measurement
only
LH=65,
LV=−5.7
2 μmR,
60° conical diamond,
3 mN or less
• Stroke: 10 mm
• For roughness and contour
measurement
Small hole stylus
DM47546*1
2X arm
LH=65,
LV=−5.025
2 μmR,
60° conical diamond,
0.75 mN
• Stroke: 5 mm
• For roughness and contour
measurement
Extra small hole
DM47506*1
stylus
LH=65,
LV=−4.625
2 μmR,
• Stroke: 5 mm
DM47507
60° conical diamond,
0.75 mN
• For roughness and contour
measurement
LH=65,
5 μmR,
• Stroke: 5 mm
LV=−30.5
DM47549
90° conical diamond,
4 mN
• For roughness and contour
measurement
Deep groove
stylus
2 μmR,
60° conical diamond,
2 mN or less
• Stroke: 5 mm
• For roughness and contour
measurement
LH=65,
LV=−55.5
DM47572
General purpose
stylus
2X arm
2 μmR,
60° conical diamond,
4 mN
• Stroke: 10 mm
• For roughness and contour
measurement
LH=130,
LV=−15.5
DM47547
DM47523
DM47595
DM47551
138.5
2 μmR,
60° conical diamond,
0.75 mN
• Stroke: 5 mm
• For roughness measurement
only
LH=65,
LV=−12.525
Corner/tooth
surface stylus
Corner/tooth
surface stylus
2X arm
2 μmR,
60° conical diamond,
4 mN or less
• Stroke: 10 mm
• For roughness measurement
only
130,
−13.5
2 μmR,
60° knife edge-shaped
diamond,
Stylus for ridge/
tooth tip mea-
surement
• Stroke: 5 mm
• For roughness and contour
measurement
LH=65,
LV=−8.35
0.75 mN
Stylus for wavi-
ness measure- DM47540
ment
• Stroke: 5 mm
• For contour (waviness)
measurement
Φ 2 ruby ball,
0.75 mN
LH=65,
LV=−14.35
*Requires master ball calibration unit for small holes. *Special stylus will be studied and proposed in accordance with customer’s workpieces.
Standard Inventory Parts87
TOKYO SEIMITSU
Surface Texture – Contour
Measuring Instruments
SURFCOM · CONTOURECORD Option
Contour Styli
*See page 90 to 91 for the details of stylus/arm for C1710/S1910.
Stylus material: Cemented carbide
Applicable models
Measuring application
General purpose
C1600
Model
C1700
S1800
S1900
External view
d
3
L1
60
L2 Applicable arm
Remarks
DM45501*2
DM45502
DM45503
DM45504 *2
DM45505*
DM45506
DM45507 *2
DM45508*
DM45509
DM45081
DM45082
DM45083*1
DM45084*
DM45085
DM45086* *1
DM45087
DM45088
DM45089*1
DM45090
DM45091
DM45092*1
52
26
13
52
26
13
52
26
13
9
010 2804
010 2800
010 2801
010 2804
010 2800
010 2801
010 2804
010 2800
010 2801
3
2
34
21
60
34
21
60
34
21
12
7
General purpose
3
ød
• Standard acces-
sory
3
L1
L2
24° conical, R0.025
2
Edge line
3
3
2
Small holes
─
─
─
─
─
─
─
─
─
─
─
─
010 2802
010 2802
010 2802
010 2802
5
3.5
12
7
1.5
9
Small hole twist
Ordinary offset
Helix surface offset
High precision
7
17
5
L1
L2
65
3.5
12
7
1.5
9
25
65
5
• Offset: 25 mm
L1
L2
17
12° angular, R0.025
3.5
12
7
1.5
9
25
65
5
• Offset: 25 mm
L1
L2
17
24° conical, R0.025
3.5
1.5
DM45522 *2
DM45523
DM45524
DM45525 *2
DM45526
DM45527
3
3
2
3
3
2
60
34
21
60
34
21
52
26
13
52
26
13
010 2804
010 2800
010 2801
010 2804
010 2800
010 2801
• Φ 0.7 ruby ball
• Φ 1 ruby ball
*Indicates stylus/arm set 010 2999
*1:Requires master ball calibration unit for small holes. *2:Requires pickup holder joint
Standard Inventory Parts
88
TOKYO SEIMITSU
Contour Detectors and Arms
*See page 90 to 91 for the details of stylus/arm for C1710/S1910.
Applicable models
Measuring application
C1600
Model
C1700
S1800
S1900
External view
Applicable arm
Remarks
E-DT-CE02A
E-DT-CE03
• C1600, S1800D/G
Contour detector
General purpose
• C1700DX/SD, S1900DX/SD
DM45502
DM45505
DM45508
DM45523
DM45526
010 2800
Inner surface
Small holes
DM45503
DM45506
DM45509
DM45524
DM45527
010 2801
179
DM45081
to
010 2802*
DM45092
Deep grooves
DM45501
DM45504
DM45507
DM45522
DM45525
• Max. magnification: x50
• 010 2744 pickup holder coupling
required
010 2804
• Provided with auxiliary weight
Offset measurement
DM45502
DM45505
DM45508
DM45523
DM45526
• Max. magnification: x100
• Offset: 50 mm
• Provided with auxiliary weight
010 2805
DM45502
DM45505
DM45508
DM45523
DM45526
• Max. magnification: x50
• Offset: 100 mm
• Provided with auxiliary weight
010 2806
DM45503
DM45506
DM45509
DM45524
DM45527
179
• Max. magnification: x100
• Offset: 50 mm
• Provided with auxiliary weight
010 2807
Long items
• Max. magnification: x10
• Lever movement range: 100 mm
• Sensitivity: 1/2
• Provided with auxiliary weight
• 010 2744 pickup holder coupling
required
DM45501
DM45504
DM45507
DM45522
DM45525
010 2808
Long holes
DM45503
DM45506
DM45509
DM45524
DM45527
• Max. magnification: x25
• Lever movement range: 100 mm
• Sensitivity: 1/2
010 2810
010 2999
• Provided with auxiliary weight
Stylus : DM45505, DM45508,
DM45084, DM45086
Arms : 010 2802, 010 2805
Arm/stylus set
Standard Inventory Parts89
*Indicates stylus/arm set 010 2999
TOKYO SEIMITSU
Surface Texture – Contour
Measuring Instruments
SURFCOM · CONTOURECORD Option
Contour Styli
Stylus material: Cemented carbide
Applicable models
Measuring application
General purpose
C1710
Model
C2600
C2700
S1910
External view
S2800
S2900
d
3
L1
60
L2 Applicable arm
Remarks
DM45501
DM45502
52 DM45531
26 DM45528
3
34
DM45503
DM45504
DM45505*
DM45506
DM45507
DM45508*
DM45509
2
3
3
2
3
3
2
21
60
34
21
60
34
21
13 DM45529
52 DM45531
26 DM45528
13 DM45529
52 DM45531
26 DM45528
13 DM45529
General purpose
ød
• Standard accessory:
DM45505
L1
L2
24° conical, R0.025
Edge line
Small holes
7
DM45510
DM45511
DM45512*1
─
─
─
12
8
9
• Measuring force:
10 mN or less
DM45530 • Deflection:
5
Approx. 1.5 μm for
10 mN
4.5 1.5
Small hole twist
7
DM45513*
DM45514
─
─
─
12
8
9
5
• Measuring force:
10 mN or less
DM45530 • Deflection:
17
L1
L2
65
Approx. 1.5 μm for
10 mN
DM45515* *1
4.5 1.5
24° conical, R0.025
Ordinary offset
Helix surface offset
High precision
DM45516
DM45517
DM45518*1
DM45519
DM45520
DM45521*1
─
─
─
─
─
─
12
8
9
5
25
• Measuring force:
10 mN or less
DM45530 • Deflection:
65
Approx. 3 μm for
10 mN
L1
L2
17
4.5 1.5
12° angular, R0.025
12
8
9
5
25
• Measuring force:
10 mN or less
DM45530 • Deflection:
65
Approx. 3 μm for
10 mN
L1
L2
17
4.5 1.5
24° conical, R0.025
ø3
21
DM45580
DM45583
3
21
13 DM45733 • Φ 0.5 ruby ball
13
ø0.5 ruby ball
• Φ 0.5 ruby ball
• Integrated with arm
─
16.5 8.5
─
DM45522
DM45523
DM45524
DM45525
DM45526
DM45527
3
3
2
3
3
2
60
34
21
60
34
21
52 DM45531
26 DM45528 • Φ 0.7 ruby ball
13 DM45529
52 DM45531
26 DM45528 • Φ 1 ruby ball
13 DM45529
*Indicates stylus/arm set DM45500
Standard Inventory Parts
*1:Requires master ball calibration unit for small holes.
90
TOKYO SEIMITSU
Contour Detectors and Arms
Applicable models
Measuring application
C1710
C2600
C2700
S1910
S2800
S2900
Model
External view
Applicable arm stylus
Remarks
E-DT-CH07A
• C2600, S2800E/G
Contour detector
E-DT-CH08A
E-DT-CH10B
• C2700DX/SD, S2900DX/SD
• C1710DX/SD, S1910DX/SD
General purpose
DM45502
DM45505
DM45508
DM45523
DM45526
• Standard configuration
• Deflection: Approx. 1.2 μm for 10 mN
Approx. 3.7 μm for 30 mN
DM45528
DM45529
DM45530*
DM45531
DM45532*
DM45533
DM45500
Inner surface
DM45503
DM45506
DM45509
DM45524
DM45527
• Deflection: Approx. 1.2 μm for 10 mN
Approx. 3.7 μm for 30 mN
179
Small holes
DM45510
to
DM45521
• Stylus combination arm for
measuring small holes
Deep grooves
DM45501
DM45504
DM45507
DM45522
DM45525
• Measuring force: 10 mN or less
(Provided with auxiliary weight)
• Deflection: Approx. 1.2 μm for 10 mN
Approx. 3.7 μm for 30 mN
Offset measurement
DM45502
DM45505
DM45508
DM45523
DM45526
• Measuring force: 10 mN or less
(Provided with auxiliary weight)
• Deflection: Approx. 2.6 μm for 10 mN
Approx. 7.8 μm for 30 mN
DM45503
DM45506
DM45509
DM45524
DM45527
179
• Measuring force: 10 mN or less
(Provided with auxiliary weight)
• Deflection: Approx. 2.6 μm for 10 mN
Approx. 7.8 μm for 30 mN
• Stylus : DM45505, DM45508,
DM45513, DM45515
Arm/stylus set
• Arms : DM45530, DM45532
*Indicates stylus/arm set DM45500
Standard Inventory Parts
91
TOKYO SEIMITSU
Surface Texture – Contour
Measuring Instruments
SURFCOM · CONTOURECORD Option
Adjustment Devices
Applicable models
S480
S1400
S1500
S2000
S5000
C1600
S1800
C1700/C1710
S1900/S1910
S2000
C2600
S2800
C2700
S2900
S-NEX
Orthogonal axis adjustment
Swivel adjust-
Tilt adjust-
Table size Allowable load
(mm)
ment
ment
Name
Model
External view
Remarks
(mm)
(net wt.) (kg)
X
Y
Z
Fine Coarse Fine Coarse
20
(7)
• Min. reading
increment 10 μm
Adjustment stand
E-AT-S01D
E-AT-S02A
E-AT-S03A
E-AT-S04A
E-AT-S05A
E-AT-S36A
E-AT-S08A
E-AT-S10B
E-AT-S11B
E-AT-S12A
E-AT-S13B
E-AT-S64B
E-WJ-S03A
50
50
8°
360°
Φ 150
Leveling
adjustment stand
15
(3)
±1.5°
80 × 110
80 × 58
80 × 125
120 × 58
200 × 120
150 × 150
75 × 40
125 × 150
Φ 90
3
(0.9)
±2.5
±8
±2°
±3°
±1°
±1°
• For E-RM-S75A
15
(8)
Adjustment stand
3
(1.4)
±3
• For E-RM-S76A
• For E-RM-S77A
5
(4.5)
±3
X-direction
movement
adjustment stand
20
(25)
400
55
3D fine
adjustment stand
1
(3.4)
55
50
28
• Straightness: 0.03 mm
• Straightness: 3 μm
• Min. reading value:
10 μm
1-axis precision
fine adjustment stand
20
(4.9)
Swivel fine
rotation stand
3
±5° 360°
• Min. reading value: 5’
(0.58)
10
• Straightness: 3 μm
• Min. reading value:
0.5 μm
1-axis ultra precision
fine adjustment stand
10
(0.7)
Coarse
movement:
10 μm
60 × 60
60 × 120
Φ 110
0.m5oμvemme)nt:
Fine
10
(1)
Tilting stand
±20°
• Min. reading value: 5’
3
(2.5)
• X/Y-direction
adjustment
Universal stand
Column rotary spacer
Column spacer
360°
360°
±90°
*1
E-CS-S31A
• Inserted between
table and column
H:100
H:200
─
*3
E-CS-S76A
*1
E-CS-S32A
• Inserted between
table and column
*3
E-CS-S77A
• Inserted between
column and tracing
driver
Tracing driver spacer E-CS-S33A*1
L : 70
• For contour measurements
E-CA-S85A:
E-CA-S24A*2
E-CA-S85A*3
±15°
±5°
─
─
For tracing driver 100 mm
E-CA-S92A:
E-CA-S92A*3
Tracing driver tilting
device
For tracing driver 200 mm
E-CA-S32A*2
• For roughness
measurements
(5)
E-CA-S101A*3
*1: Cannot be used with S3000A Series and S5000 Series.
*2: Cannot be used for Linear Series and S3000A and S5000 Series. For S1400D,S1800D,S2800E,C1600D,C2600E.
*3: For Linear Series and S1400G, C1600G, S1800G, C2600G, S2800G and S2800G Series.
Standard Inventory Parts
92
TOKYO SEIMITSU
Holders
Applicable models
Name
S480
S1400
S1500
S2000
S5000
C1600
S1800
C1700/C1710
Chucking
(mm)
S1900/S1910
Vice
(mm)
S2000
Clamp
(mm)
C2600
S2800
C2700
S2900
S-NEX
V Holder
Flat surface Allowable load
(mm)
Model
External view
Remarks
(mm)
(net wt.) (kg)
Inside: 59
outside:
38 to 105
Consult us when
combining with the
tilt stand.
5
(0.8)
Double-side open vice E-WJ-S01B
Provided with
workpiece clamper
V-stand set
E-WJ-S02A
E-WJ-S04A
E-WJ-S05A
E-WJ-S06A
E-WJ-R01C
Φ 1 to Φ 150
Φ 12 to Φ 150
Φ 4 to Φ 10
(1.5)
(3)
Two pieces used
just for T-groove
clamp
V-stand holder set
Compact stand
Load plate
(0.4)
(1)
150 × 150
angle
plate
OD:
Φ 2 to Φ 79
ID:
Scroll chuck
Iris chuck
(1)
Φ 56 to Φ 90
OD:
Φ 5 to Φ 110
OD:
00
( 3 )
00
E-WJ-R10A
E-WJ-R378A
Manufactured after
receipt of order
Φ 5 to Φ 150
( 5 )
Height
40 to 60
Clamp set
JC-3
-
300 × 300
angle
plate
Manufactured after
receipt of order
E-WJ-S252A
E-WJ-S234A
(5.3)
(15)
Ceramic load plate
500 × 500
angle
plate
Manufactured after
receipt of order
Standard Inventory Parts
Sample Adjustment Stand/Holder Configurations
Scroll chuck
E-WJ-R01C
V-stand set
V-stand set
E-WJ-S02A
E-WJ-S02A
Universal stand
E-WJ-S03A
Tracing driver
E-RM-S76A
Leveling
adjustment stand
E-AT-S02A
Adjustment
stand
E-AT-S05A
Adjustment stand
E-AT-S04A
Adjustment stand
E-AT-S04A
V-stand set
E-WJ-S02A
V-holder set
E-WJ-S04A
Adjustment
stand
Double-side open vice
E-WJ-S01B
E-AT-S01D
Universal stand
E-WJ-S03A
X-direction movement
adjustment stand
E-AT-S08A
X-direction movement
adjustment stand
E-AT-S08A
Adjustment stand
E-AT-S01D
93
TOKYO SEIMITSU
Surface Texture – Contour
Measuring Instruments
SURFCOM · CONTOURECORD Option
Peripherals
Name
Model
External view
Specifications
Remarks
• E-RM-S72B:
Drive distance: 100 mm
Driving speed: 0.03 mm/s to 6.0 mm/s, 8
speeds
Straightness accuracy: (0.05 + 1.5L/1000) μm
Weight: Approx. 9 kg
excluding C2600, 2800
• E-RM-S138B:
E-RM-S72B/
S138B
for C2600, 2800
• S480: E-RM-S71B
Specifications same
as shown to left
• E-RM-S178B:
Drive distance: 200 mm
excluding C2600, 2800
• E-RM-S182B:
Pickup
movement
tracing driver
(For standard series)
E-RM-S178A/
S182A
Driving speed: 0.03 mm/s to 6.0 mm/s, 8 speeds
Straightness accuracy: (0.05 + 1.5L/1000) μm
Weight: Approx. 15 kg
for C2600, 2800
• S480: E-RM-S73B
Specifications same
as shown to left
Drive distance: 100 mm
• S480: E-RM-S78A
Specifications same
as shown to left
Driving speed: 0.003 mm/s to 6.0 mm/s, 11 speeds
Straightness accuracy: (0.05 + 1.5L/1000) μm
Weight: Approx. 9 kg
E-RM-S141A
E-RM-S205A
E-RM-S183E
Drive distance: 100 mm
Driving speed: 0.03 mm/s to 6.0 mm/s
Straightness accuracy: (0.05 + L/1000) μm
Weight: Approx. 9 kg
Pickup
movement
tracing driver
(For linear series)
Drive distance: 200 mm
Driving speed: 0.03 mm/s to 6.0 mm/s
Straightness accuracy: (0.05 + L/1000) μm
Weight: Approx. 15 kg
Drive distance: 50 mm
Driving speed: 0.03 mm/s to 6.0 mm/s, 8 speeds • Cannot be used for
Straightness accuracy: (0.05 + 1.5L/1000) μm
Weight: Approx. 15 kg
Load weight: 5 kg
Linear Series.
• Requires pickup
holder stand.
E-RM-S75A
E-RM-S76A
E-RM-S77B
Leveling range: ±1.5°
Drive distance: 150 mm
Driving speed: 0.03 mm/s to 6.0 mm/s, 8 speeds • Cannot be used for
Straightness accuracy: (0.05 + 1.5L/1000) μm
Weight: Approx. 20 kg
Load weight: 5 kg
Workpiece
movement
tracing driver
Linear Series.
• Requires pickup
holder stand.
Leveling range: ±1°
Drive distance: 300 mm
Driving speed: 0.03 mm/s to 6.0 mm/s, 8 speeds • Cannot be used for
Straightness accuracy: (0.05 + 1.5L/1000) μm
Weight: Approx. 32 kg
Load weight: 10 kg
Linear Series.
• Requires pickup
holder stand.
Leveling range: ±0.8°
Measuring OD: Φ 12 mm to 20 mm
Length: 30 mm to 150 mm
OD: Φ 20 to 150 mm
Length: 30 mm to 250 mm
Peripheral velocity: 0.3, 0.6, 1.5 mm/s
Weight: Approx. 7 kg
Outer periphery
roughness
tracing driver
E-RM-S85B
Load weight: 5 kg
Measuring radius: 0.25 mm to 40 mm
Rotation accuracy: ±0.25 μm (180° arbitrary)
Peripheral velocity: 0.3 mm/s (stepless)
Weight: Approx. 15 kg
Round surface
roughness
tracing driver
E-RM-S84A
Y-axis direction
stroke 200
Range of movement :
X : 660 mm
Y : 200 mm
For measurement of
large and heavy parts
(Manufactured upon
receipt of order)
Column cross
feed device
E-ST-S131A
Weight: Approx. 370 kg
Leveling range: ±2°
Load weight: 5 kg
Auto tilting table
E-AT-S72A
Standard Inventory Parts
94
TOKYO SEIMITSU
Name
Model
E-DH-
External view
Specifications
Remarks
• Maximum extrusion:
90mm from left end of driver
• Column height:
10mm less than normal height
• For S2000DX/SD
Wide-Range (Hybrid)
Detector Holder
Magnification:x5000 or less
Straightness:0.5 μm/100 mm
S182A
Pickup
holder stand
E-CA-
S25A
• When workpiece movement tracing
driver is used
Weight: Approx. 1.5 kg
M a g n ifi c a t io n :
Skid measurement x5000
Min. inner dia: Up to Φ 25 mm
Max. depth: 650 mm
• Used with large measuring stand
• For S480B, S1400G, S1800G, S2800G
010 2736
Weight: Approx. 1.2 kg
Rod diameter: Φ 21.7 mm
Connecting rod
for ultra-long hole
measurement
Magnification: Up to x5000
Min. inner dia: Up to Φ 18 mm
Max. depth: 630 mm
Weight: Approx. 1.2 kg
Rod diameter: Φ 14 mm
• For S1500, S1900G, S1910, S2900,
S-NEX001, 031, 041, 131, 141
DM57537
010 2744
010 2745
010 2746
• Used with 010 2804 and
010 2808 contour profile arms
• Applicable to all models
Coupling length: 30 mm
Weight: Approx. 0.25 kg
Pickup holder
coupling
Measuring depth: Up to 131 mm
beneath tracing driver
Weight: Approx. 0.47 kg
• Applicable to all models
Measuring depth: 142 mm
beneath detector holder
Weight: Approx. 0.2 kg
Rod diameter: Φ 21.7 mm
Pickup right
angle coupling/
connecting rod
• Pickup vertical measurement using
hole bottom stylus
Ordinary stand
for desktop
anti-vibration table
Dimensions:
510 mm × 430 mm × 643 mm
Weight: 22 kg
E-VS-
S13A
• For E-VS-S57A/B, E-VS-S58A
510
430
Anti-vibration: Pneumatic diaphragm spring
Natural frequency: 2.5 Hz to 3.5 Hz
Load weight: 130 kg
Dimensions: 600 mm × 530 mm × 60 mm
Air source: 350 kPa to 700 kPa
Weight: 25 kg
• With regulator
• Air tube (external diameter Φ 6)
attached.
E-VS-
S57B
Desktop
anti-vibration table
Anti-vibration: Pneumatic diaphragm spring
Natural frequency: 2.5 Hz to 3.5 Hz
Load weight: 130 kg
Dimensions: 600 mm × 530 mm × 60 mm
Weight: 25 kg
E-VS-
S58B
• Air source: Pump
1000
Anti-vibration:
Pneumatic diaphragm spring
Natural frequency: 4 Hz
Load weight: 300 kg
Dimensions:
Desktop large
anti-vibration table
E-VS-
S45A
• Air source: Pump
1000 mm × 750 mm × 143 mm
Weight: 80 kg
125
750
125
Anti-vibration: Pneumatic diaphragm spring
Natural frequency: V: 2 Hz; H: 2.2 Hz
Load weight: 250 kg
Dimensions: 980 mm × 780 mm × 700 mm
Air source: 350 kPa to 700 kPa
Weight: 170 kg
E-VS-
R16B
• With regulator
Anti-vibration table
Anti-vibration: Pneumatic diaphragm spring
Natural frequency: V: 1.6 Hz; H: 2 Hz
Load weight: 550 kg
Dimensions: 1100 mm × 850 mm × 700 mm
Air source: 350 kPa to 700 kPa
Weight: 340 kg
E-VS-
S21B
• With regulator
*3 If retrofitted to S2000 and SNE100, correction value needs to be obtained again.
Standard Inventory Parts
95
TOKYO SEIMITSU
Surface Texture – Contour
Measuring Instruments
SURFCOM · CONTOURECORD Option
Name
Model
External view
Specifications
Remarks
Dimensions:
E-DK-S24A
800 mm × 800 mm × (1070 to 1370) mm
Weight: 44.5 kg
System rack
Dimensions:
1200 mm × 800 mm × (1070 to 1370) mm
E-DK-S25A
Dimensions:
400 mm × 700 mm × 700 mm
Side desk
E-DK-S10A
• Used with desktop anti-vi-
bration table/stand for
roughness measuring
• For Standard/Linear
series SD type (Excluding
S5000, S3000)
Transparent
vinyl sheet
Dimensions:
750 mm × 614 mm × 810 mm
Weight: 8 kg
E-CV-S02A
W
D
Transparent
acrylic plate
High magnifi-
cation
dust cover
H
• Used with desktop anti-vi-
bration table/stand for
contour profile measure-
ment
Dimensions:
1000 mm × 629 mm × 810 mm
Weight: 13 kg
E-CV-S03A
•
For Standard/Linear series
SD type
(Excluding S5000, S3000)
Dimensions:
1070 mm × 750 mm × 1050 mm
Weight: 20 kg
• Used with E-VS-S21A an-
ti-vibration table for large
measuring table
Dust cover
E-CV-S25A
Microscope
X25
Magnification: x20
Focal distance: 60 mm
E-MA-S81A
DM59014
E-MA-S84A
DM59103
• Stand type
Stand
Microscope knob
Measuring
position
verification unit
Light guide (option)
• Can be used with work-
piece movement tracing
driver
CCD camera
Magnification: x20
Focal distance: 60 mm
(option)
Microscope
Flexible arm
Fine
movement
knob
Light guide
Flexible arm
Light
• Stand type
Fixing knob
115
70
Light guide (option)
Configuration
(1) Color camera
(2) Color monitor
(3) Power adapter
(4) Microscope adapter
(5) Connection cable
(6) Instruction manual
Image sensor:
Color camera
monitoring
system
Interline type CCD
Effective pixels:
768 mm × 494 mm
CCD camera
(option)
Microscope
(sold separately)
Standard Inventory Parts
96
TOKYO SEIMITSU
Name
Model
External view
Specifications
Remarks
• For pickup movement tracing
driver
Tape tension jig DM58526
Calibration surface:
Approx. 3.1 μm Ra
Stylus check surface:
Approx. 0.4 μm Ra
Measured value described.
• For sensitivity calibration and for
checking stylus
• Applicable to JCSS calibration
and NIST calibration
Reference
E-MC-S24C
specimen
• Standard accessory for linear
series roughness system
• For detector sensitivity calibration
and stylus check
Level
Large range: Approx. 20 μm
Small range: Approx. 2 μm
Measured value described.
difference
E-MC-S57A
reference
specimen
• Applicable to JCSS calibration
Narrow range accuracy:
0 to 10 μm ±0.1 μm
Wide range accuracy:
0 to 400 μm ±1.0 μm
Magnification
E-MC-S50C
calibrator
• For magnification calibration
181.5
Block gage
Master ball
ø12.7mm(1/2)
• For measurements with stylus
pointing downwards
46
25
E-MC-S34A
• Standard accessory for
C1600D/G, C2600E/G,
C1700DX/SD, C2700DX/SD
Y-direction adjustment
table
60
85
Block gage
マスターボール
Master ball
• For measurements with stylus
pointing downwards
• Standard accessory for
S2000DX/SD, SNEX100
Y-direction adjustment table
E-MC-S65B
60
82
Master ball
calibration unit
• For measurements with stylus
pointing downwards
• Standard accessory for
S3000A, S5000DX/SD
E-MC-S48A
Master ball calibration unit
• For measurements with stylus
pointing upwards
• For C2600E/G, S3000A,
C2700DX/SD, S5000DX/SD
E-MC-S51A
• For measurements with stylus
pointing downwards and stylus
for small bore measurement
• For C1600, C1700DX/SD,
C2600, S3000A
• For C2700DX/SD, S2000DX/SD,
S5000DX/SD, S2000, SNEX100
Block gageꢀ1.5mm
Calibration ball
1 .5 m m
Small hole
stylus master
E-MC-S59D
ball calibration
φ
Block gage: 1.5 mm
Reference sphere: Φ1.5 mm
6
unit
Standard
plate
63
Pin diameter: 7.9 mm
Pitch: 15 mm
Dimensions:
Pitch gage
E-MG-S02A
E-MG-S24A
144 mm × 38 mm × 49 mm
1
(Edge line length)
90
Stylus check
master
Tip radius: 0.1 μm or less
Material: Knife edge diamond
ø64
Input: 90 V to 240 V
Output: 100 V
Capacity: 2.1 kVA
Dimensions:
300 mm × 350 mm × 296 mm
Weight: 45 kg
Power
transformer
box
E-TF-R25A
• Specify the input voltage
Standard Inventory Parts
97
TOKYO SEIMITSU
Surface Texture – Contour
Measuring Instruments
SURFCOM · CONTOURECORD Option
Accessories for SURFCOM 130A, FLEX-50A
Name
Model
External view
Specifications
Table size:
Remarks
410 mm × 200 mm
Max. measuring height:
200 mm
Weight: Approx. 18 kg
Load weight: 20 kg
Compact
measuring
stand
• Tracing driver height and tilt can be
adjustable depending on a size
and form of a workpiece
0
10
20
30
40
50
MILLIMETER
INCH
S
U
R
F
C
O
M
1
3
0
A
E-ST-S130A
128 ~178
68
330
60
20
135
60
5
410
200
• All orientations
5 μm R90°conical diamond, • Horizontal tracing possible
E-DT-SE18A
4mN
• With 0102501 stylus
• For S130A, S-FLEX50A
Pickup
2 μm R60°conical diamond,
0.7mN
E-DT-SE19A
E-MA-S54A
• Standard accessory
Touch pen
Battery set
• Specialized for S130A, S480A/B
• Battery charger for 130A
• Size: 80 mm × 85 mm × 45 mm
• Weight: Approx. 400 g
• Charging time: 4 hours
Measurements and recording are available
on-site where there is no power source
E-MA-S65A
Contents:
AC adapter, battery charger, battery
• Battery for 130A
• Size: 203 mm × 58 mm × 67 mm
• Weight: Approx. 1.2 g
• Attachment for placing the tracing driver
on a roll shaped object for measurement
• Roll outer diameter: Φ 60 mm or more
E-MA-S62A
Roll foot
• Photo shows unit of E-MA-63A
• Roll outer diameter: Φ 60 mm or more
E-MA-S63A
E-MA-S64A
• For Amplification indicator
• Specialized for S130A, S480A/B
Dust proof cover
• For measuring surface roughness of
slanted surfaces, vertical surfaces, ceiling
surfaces and other non-flat surfaces
•Limited to the skid measurement
All position pickup
holder
E-DH-S107A
• Attachment for horizontal tracing of items,
such as crankshafts which have obstacles
in the front and back in the measuring
direction
(using double-side stradding skid)
•Limited to the skid measurement
Horizontal tracing
pickup holder
E-DH-S17A
E-CA-S62A
Attachment for
tracing driver
• 50 mm tracing driver attached to manual
column (E-CL-S133A)
• Cable connected
• Specialized for S130A
RS-232C cable
E-SC-S288A
E-MC-S24C
Support 9pin Windows PC
Calibration surface:
Approx. 3.1 μmRa
Stylus check surface:
Approx. 0.4 μmRa
Reference
specimen
• For sensitivity calibration and stylus check
• Standard accessory
Measured value described
Standard Inventory Parts
98
TOKYO SEIMITSU
Accessories for HANDYSURF E-35B, 40A, 45A and SURFCOM FLEX-35B, 40A, 45A
Name
Model
External view
Specifications
Remarks
• For general
measurement
• Standard accessory
E-DT-SM10A
E-DT-SM49A
E-DT-SM39A
5 μm, 90° conical diamond, 4 mN (For 35B · 40A)
2 μm, 90° conical diamond, 0.75 mN (For 35B · 40A)
5 μm, 90° conical diamond, 4 mN (For 45A)
• For fine hole
• Min. inner diameter:
Φ 5 mm
E-DT-SM11A
E-DT-SM50A
5 μm, 90° conical diamond, 4 mN (For 35B · 40A)
2 μm, 90° conical diamond, 0.75 mN (For 35B · 40A)
Pickup
• For extra fine hole
E-DT-SM12A
E-DT-SM51A
5 μm, 90° conical diamond, 4 mN (For 35B · 40A)
2 μm, 90° conical diamond, 0.75 mN (For 35B · 40A)
•
Min. inner diameter:
Φ 3 mm
5 μm, 90° conical diamond, 4 mN (For 35B · 40A) • For deep groove
2 μm, 90° conical diamond, 0.75 mN (For 35B · 40A) • Max. depth: 7 mm
E-DT-SM13A
E-DT-SM52A
クランプ解除レバー
ワーク端面
• For HANDYSURF
E-35B and SURFCOM
FLEX-35B
• With attachment
mechanism
最大測定径
:
Ø95
Ø71.5
クランプローラ
最小測定径
:
Specialized driver for
the bore roughness E-RM-S224C
measurement
Measuring range 130 mm
Max. measuring diameter Φ95 mm
Min. measuring diameter Φ71.5 mm
130
120
110
100
90
80
70
60
50
40
30
20
10
0
130 (測定範囲
)
100
340
•
Standard accessory
for 35B, 40A
E-WJ-S64A
Adjustment device
(Rear)
• Standard accessory
for 45A
E-WJ-S559A
• For 35B, 40A
E-WJ-S80A
Adjustment device
(Front)
• For 45A
E-WJ-S560A
Place a
• For 35B
E-WJ-S85A
V-shaped part
at lower side on
a workpiece for
measurement
Applicable up to
Φ 50
Nose piece (Cyl-
inder)
• For 35B, 40A
• For 35B
E-WJ-S562A
Place a
E-WJ-S88A
Nose piece (Flat)
protrusion and
lower side of
tracing driver on
a workpiece for
measurement
• For 35B, 40A
E-WJ-S561A
•
Standard accessory
for 45A
Nose piece
E-WJ-S536A
(V-shape)
Nose piece
• For 45A
E-WJ-S563A
(contact type)
長穴測定用アダプタ
(DT57507)
ピックアップ(E-DT-SM10A)
駆動部(E-RM-S59A)
Extension adapter
DM57506
• For 35B, 40A
for long hole
67.5~ 80
2 or more
adaptors
cannot be
used.
駆動部(E-RM-S59A)
ピックアップ(E-DT-SM10A)
横トレ-スホルダ
(DT57507)
Adapter for hori-
zontal measure-
ment
• For 35B, 40A
DM57507
4.5
1.5
68
22
Adapter for bore
measurement
• For 35B, 40A
E-WJ-S86A
Place a central pin on a lower bore
Standard Inventory Parts
99
TOKYO SEIMITSU
Surface Texture – Contour
Measuring Instruments
SURFCOM · CONTOURECORD Option
Accessories for HANDYSURF E-35B, 40A, 45A and SURFCOM FLEX-35B, 40A, 45A
Name
Model
External view
Specifications
Remarks
Holder for tracing
driver
E-MD-S200A
Mounted on side of FLEX amplifier
• For FLEX-35B, 40A
Magnetic stand
Post mount holder
Post mount
E-ST-MAC
010 2050
E-CS-S26A
E-WJ-S93A
• For Φ 6
Cross-section surface on scriber of height
gage:
9 mm × 9 mm
Adapter for height
gage
• Used with post mount,
E-SC-S26A
• With sample program for
communication
E-SC-S366A
RS-232C cable
Support 9 pin Windows PC
• Used with E-SC-S366A in
case PC has no RS port
USB-RS adapter
Consumables
Name
Model
External view
Specifications
Remarks
• 128MB
Remarks
Provides registrations of approx. 500
measurement conditions and storage of
approx. 500 measurement data
(200 text management items)
CF card +
adaptor
E-MU-S50C
130A, 480B
130A, 480B
• 10 rolls/box
E-CH-S21A
E-CH-S25A
• External diameter: Φ 47 mm,
external width: 58 mm, roll length: 25 m
High-speed printer for E35A , E35B,
E40A, E45A
E-RC-S24A
Compact printer for E35A, E35B, E40A, E45A
built-in printer for FLEX,
compact printer II for E35A/B, E40A,
E45A
E-RC-S23A
E-RC-S25A
E-RC-S29A
• 10 rolls/box
• External diameter: Φ 24 mm,
external width: 58 mm, roll length: 7 m
100B, 300B, 400B, 500B, 700B, 720B
550A, 900A/B, 920A, 730A, 470A, 740A
E-RC-S01A/B
E-RA-S01A
E-RA-S03A
• 10 rolls/box
• External diameter: Φ 58 mm,
external width: 80 mm, roll length: 40 m
• Grid width□50mm
E-CH-50A
200B
Recording
paper
200C
570A, 590A, 750A, 790A
440A, 470A, 740A, 900B, 920B
• 10 rolls/box
• External diameter: Φ 58 mm,
external width: 60 mm, roll length: 40 m
E-CH-S05B
E-RC-S09A
• 20 rolls/box
• External diameter: Φ 50 mm,
external width: 68 mm, roll length: 25 m
110A, 350A, 550A, 470A
730A, 740A, 920
E-CH-S02A
JIS No.121
E-CH-S26A
E-IR-S01A
• 100 sheets/leaflet
• A3 leaflet
E-RC-XY16
E-RC-S30A
600B/C/D
• 10 rolls/box
• External diameter: Φ 38 mm,
external width: 58 mm, roll length: 19 m
Compact printer III for E35B, E40A,
E45A
110A, 110B, 350A, 550A, 470A
730A, 740A, 920A
Ink ribbon
Standard Inventory Parts
100
TOKYO SEIMITSU
相关型号: