3B16-01 [ADI]
Narrow Bandwidth Strain Gage Input; 窄带宽应变计输入型号: | 3B16-01 |
厂家: | ADI |
描述: | Narrow Bandwidth Strain Gage Input |
文件: | 总8页 (文件大小:350K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Narrow Bandwidth Strain Gage Input
3B16
FUNCTIONAL BLOCK DIAGRAM
FEATURES
Interfaces, amplifies, & filters signals from 4-arm full-bridge
strain-gage bridges with a resistance from 300Ω to 1 kΩ.
Module provides a constant +10V bridge excitation voltage.
Module provides simultaneous precision voltage and
current outputs.
Module circuitry can withstand 130v rms at the input screw-
terminals
All 3B16 series modules are mix-and-match and Hot
Swappable
Figure 1. 3B16 Functional Block Diagram
APPLICATIONS
Output modules accept 0 to +10V (or +10V) single-ended
signals and provide an isolated 4-20 mA (or 0-20 mA) process
signal. All modules feature a universal pin-out and may be
readily hot-swapped under full power and interchanged without
disrupting field wiring.
Industrial signal conditioning
Industrial signal isolation
Industrial signal filtering
PRODUCT OVERVIEW
The Analog Devices 3B Series Signal Conditioning Subsystem is
designed to easily handle signal conditioning problems in
measurement and control applications. Some typical uses are in
microcomputer-based data acquisition systems, programmable
controllers, analog recorders, dedicated control systems, and any
other applications where monitoring of temperature, pressure,
flow and analog signals are required. Since each input module
features two simultaneous outputs, the voltage output can be
used to provide an input to a microprocessor-based data
acquisition or control system while the current output can be
used for analog transmission, operator interface, or an analog
backup system.
The 3B Series of Signal Conditioning I/o Subsystems provide a
low-cost, versatile method of transferring analog transducer
signals to a data acquisition, monitoring or control system
without the inherent noise, non-linearity, drift and extraneous
voltages. The modules are designed to directly accept analog
signals from Thermocouples, RTD’s, AC and DC Strain Gages,
Torque Transducers, Frequency Transducers, LVDTs, millivolt
or process current signals. The modules amplify, isolate,
linearize and convert the transducer output signals to
standardized analog inputs for high-level analog I/O
subsystems. The 3B Series Subsystem consists of a 10” relay
rack with universal mounting backplane and a family of plug-in
(up to 16 per rack) input and output signal conditioning
modules.
Each input module is a single-channel signal conditioner which
plugs into a socket on the backplane and accepts its signal from
the input screw terminals. All input modules provide input
protection, amplification and filtering of the input signal,
accuracy of +0.1%, low drift of +1 uV/ oC (low-level input
modules), and feature two high-level analog outputs that are
compatible with most process instrumentation. The isolated
input modules also provide +1500 V peak isolation.
Eight and four channel backplanes are also available. Each
backplane incorporates screw terminals for sensor inputs and
current outputs and a 26-pin connector for high-level single-
ended voltage outputs to the user’s equipment.
The input modules feature complete signal conditioning
circuitry optimized for specific sensors or analog signals and
provide two simultaneous high-level analog outputs: 0 to +10V
(or +10V) and 4-20 mA (or 0-20 mA).
The choice of a specific 3B module depends upon the type of
input signal. Input modules are available to accept millivolt, volt,
process current, thermocouple, RTD, AC and DC strain gage,
frequency and LVDT inputs. The voltage output of each module
is available from the system I/O connector while the current
output is available on the output screw terminals.
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable.
However, no responsibility is assumed by Analog Devices for its use, nor for any
infringements of patents or other rights of third parties that may result from its use.
Specifications subject to change without notice. No license is granted by implication
or otherwise under any patent or patent rights of Analog Devices. Trademarks and
registered trademarks are the property of their respective companies.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
Fax: 781.326.8703
www.analog.com
© 2004 Analog Devices, Inc. All rights reserved.
3B16
GENERAL DESCRIPTION
selecting resistors, a Windows program, 3B-CUSTOM,
The 3B16 is a single-channel signal conditioning module which
interfaces, amplifies, and filters signals from 4-arm full-bridge
strain-gage bridges with a resistance from 300W to 1kW. The
module provides a constant +10V bridge excitation voltage and
provides simultaneous precision voltage and current outputs.
The user-configurable Model 3B16-00 can be applied in
applications involving large tare weights which must be
compensated with zero suppression. The 3B16 protects the
computer side from damage due to field-side over-voltage faults
up to 130V rms. In addition, the current output withstands
130V rms without damage and interfaces user equipment
through screw terminals located on the 3B Series backplane.
The 3B16 is a plug-in, mix-and-match, hot-swappable module
which is easily field calibrated via front-panel zero and span
adjustments for both voltage and current outputs.
calculates resistor values based on the user-desired input/output
ranges.
A chopper-stabilized low-drift (+1uV/oC) input amplifier
assures long-term stability. At the amplifier input, a stable, zero-
scale input voltage is subtracted from the input signal to set the
zero-scale value. Zero suppression can exceed 100% of the input
range. This is ideal for expanded-scale applications requiring
high-resolution measurement of a selected portion of an input
signal. For user convenience, the zero and span can be factory
configured to meet custom range needs (Model 3B16-
CUSTOM) or can be externally programmed (Model 3B16-00)
via user supplied resistors inserted in the optional AC1310 plug-
on ranging card. Internal low-pass filtering with a 3 Hz cutoff
(-3dB) two-pole Butterworth filter enhances a 60 dB normal-
mode rejection at 50/60 Hz, enabling accurate measurement of
small signals in high electrical noise.
3B Series Custom-Ranging Program – Externally-
programmable Model 3B16-00, enables the user to configure a
special input range, including tare weight suppression, by using
the optional plug-on AC1310 ranging card, which houses user-
supplied resistors to determine zero and span. To facilitate
.
.
Figure 2
Rev. 0 | Page 2 of 8
3B16
3B16 Models Available
Model
Input
Bridge
Input
Range
Excitation
+10 V
Sensitivity
Output
Ranges1
3B16-00
Full Bridge
Full Bridge
Full Bridge
Externally
Externally
-10 V to +10 V &
0 mA to 20 mA
Programmable2
Programmable2
3B16-01
-30 mV to +30 mV
+10 V
3 mV/V
-10 V to +10 V &
0 mA to 20 mA
3B16-Custom
*
+10 V
*
*
1 Output current range may be user programmed to 4 mA to 20 mA using jumper supplied.
2 Requires AC1310 ranging card.
* Custom Input/Output ranges are available. Refer to configuration guide.
3B16 Specifications
(typical @ +25°C and ±15 V dc, and +24 V dc Power)
Description
Model 3B16
Input Range
Standard Range
Custom Ranges
±30 mV (3 mV/V sensitivity @ Vexc = +10V)
±5 mV to ±500 mV
Output Range
-10 V to +10 V
Voltage (RL > 2 KΩ)
Current (RL = 0 to 850Ω)1
Maximum Current Output Span
4 mA to 20 mA or 0 mA to 20 mA
0 mA to 31 mA
Accuracy2
Initial @ +25°C
Nonlinearity2
±0.1% Span
±0.01% Span
Stability vs. Temperature
Voltage Output
Zero
±3 µV/°C (RTI)
Span
±25 ppm of Reading/°C
Current Output3
Zero
±25 ppm of Span/°C
Span
±25 ppm of Reading/°C
Bridge Excitation
+10 V
Voltage
Voltage, tolerance
Voltage vs. Temperature
±2%
±0.0015%/°C
Bridge Resistance Range
Rev. 0 | Page 3 of 8
3B16
Vexc= +10.0 V
300 Ωto 1 kΩ
±5% of Span
Zero and Span Adjustment Range4
Input Bias Current
+3 nA
Input Resistance
100 MΩ
Noise
Input, 0.1 Hz to 10 Hz Bandwidth
Output, 100 kHz Bandwidth
Bandwidth, -3 dB
0.2 µV rms
50 µV rms
3 Hz
Output Rise Time, 10% to 90% Span
200 ms
Common-Mode Voltage (CMV)
±10 V peak, maximum
ANSI/IEEE C37.90.1-1989
60 dB
Input-to-Output, Continuous
Transient
Normal Mode Rejection @ 50/60 Hz
Input Protection, Signal and Excitation Voltage
130 V rms maximum
ANSI/IEEE C37.90.1-1989
Continuous Short to Ground
130 V rms, continuous
Power Supply Voltages 5
Continuous
Trasient
Voltage Output Protection
Current Output Protection
±15 V dc Supplies
Rated Operation
Current
±(12.7 V dc to 16.5 V dc)
+45 mA, -10 mA
Sensitivity
±0.01% span/V
+24 V dc Loop Supply
Rated Operation
Current
+12 V dc to +30 V dc
+27 mA @ lout = 20 mA
±0.0002% span/V
Sensitivity
Mechanical Dimensions
3.15" x 3.395" x 0.775"
80.0 mm x 86.2 mm x 19.7 mm)
Environmental
Temperature Range
Rated Performance
Storage
-25°C to +85°C
-55°C to +85°C
Relative Humidity, 24 hours
RFI Susceptibility
0 to 95% @ +60°C noncondensing
±0.5% Span error @ 400 MHz, 5 Watt, 3 ft
1 For a 0 mA to 20 mA range, a typical minimum output current is 10 µA.
2 Includes the combined effects of repeatability, hysteresis, and nonlinearity.
3 With respect to the voltage output.
4 A wide range of custom zero suppression and span is available with the 3B16-00 model, using the AC1310 ranging card.
5 +24 V dc loop power is required for driving the current output at loads up to 850Ω. If a current output load of 400Ω or less is applied, +15 V dc is sufficient for loop power. If only
voltage output is used, loop power is not required.
Specifications subject to change without notice.
Rev. 0 | Page 4 of 8
3B16
PIN CONFIGURATIONS AND FUNCTIONAL DESCRIPTIONS
Figure 3 3B16 Input Field Connections
Table 1. Pin Function Descriptions—
Pin No.
Description
1
2
3
4
+EXC
HI
LO
-EXC
Figure 4 . Model 3B Series Module, with pin-out assignments.
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human
body and test equipment and can discharge without detection. Although this product features proprietary ESD
protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges.
Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality.
Rev. 0 | Page 5 of 8
3B16
OUTLINE DIMENSIONS
Figure 5. Outline Dimensions
Rev. 0 | Page 6 of 8
3B16
NOTES
Rev. 0 | Page 7 of 8
3B16
NOTES
©
2004 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective companies.
D05104-0-9/04(0)
Rev. 0 | Page 8 of 8
相关型号:
©2020 ICPDF网 联系我们和版权申明