AD590J [ADI]
Two-Terminal IC Temperature Transducer; 双端IC温度传感器型号: | AD590J |
厂家: | ADI |
描述: | Two-Terminal IC Temperature Transducer |
文件: | 总12页 (文件大小:151K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Two-Terminal IC
Temperature Transducer
a
AD590
P IN D ESIGNATIO NS
FEATURES
Linear Current Output: 1 A/ K
Wide Range: –55؇C to +150؇C
Probe Com patible Ceram ic Sensor Package
Tw o Term inal Device: Voltage In/ Current Out
Laser Trim m ed to ؎0.5؇C Calibration Accuracy (AD590M)
Excellent Linearity: ؎0.3؇C Over Full Range (AD590M)
Wide Pow er Supply Range: +4 V to +30 V
Sensor Isolation from Case
Low Cost
P RO D UCT D ESCRIP TIO N
P RO D UCT H IGH LIGH TS
T he AD590 is a two-terminal integrated circuit temperature
transducer that produces an output current proportional to
absolute temperature. For supply voltages between +4 V and
+30 V the device acts as a high impedance, constant current
regulator passing 1 µA/K. Laser trimming of the chip’s thin-film
resistors is used to calibrate the device to 298.2 µA output at
298.2K (+25°C).
1. T he AD590 is a calibrated two terminal temperature sensor
requiring only a dc voltage supply (+4 V to +30 V). Costly
transmitters, filters, lead wire compensation and linearization
circuits are all unnecessary in applying the device.
2. State-of-the-art laser trimming at the wafer level in conjunc-
tion with extensive final testing ensures that AD590 units are
easily interchangeable.
T he AD590 should be used in any temperature sensing applica-
tion below +150°C in which conventional electrical temperature
sensors are currently employed. T he inherent low cost of a
monolithic integrated circuit combined with the elimination of
support circuitry makes the AD590 an attractive alternative for
many temperature measurement situations. Linearization
circuitry, precision voltage amplifiers, resistance measuring
circuitry and cold junction compensation are not needed in
applying the AD590.
3. Superior interface rejection results from the output being a
current rather than a voltage. In addition, power require-
ments are low (1.5 mWs @ 5 V @ +25°C.) T hese features
make the AD590 easy to apply as a remote sensor.
4. T he high output impedance (>10 MΩ) provides excellent
rejection of supply voltage drift and ripple. For instance,
changing the power supply from 5 V to 10 V results in only
a 1 µA maximum current change, or 1°C equivalent error.
5. T he AD590 is electrically durable: it will withstand a forward
voltage up to 44 V and a reverse voltage of 20 V. Hence, sup-
ply irregularities or pin reversal will not damage the device.
In addition to temperature measurement, applications include
temperature compensation or correction of discrete compo-
nents, biasing proportional to absolute temperature, flow
rate measurement, level detection of fluids and anemometry.
T he AD590 is available in chip form making, it suitable for
hybrid circuits and fast temperature measurements in protected
environments.
T he AD590 is particularly useful in remote sensing applications.
T he device is insensitive to voltage drops over long lines due to
its high impedance current output. Any well insulated twisted
pair is sufficient for operation hundreds of feet from the
receiving circuitry. T he output characteristics also make the
AD590 easy to multiplex: the current can be switched by a
CMOS multiplexer or the supply voltage can be switched by a
logic gate output.
REV. B
Inform ation furnished by Analog Devices is believed to be accurate and
reliable. However, no responsibility is assum ed by Analog Devices for its
use, nor for any infringem ents of patents or other rights of third parties
which m ay result from its use. No license is granted by im plication or
otherwise under any patent or patent rights of Analog Devices.
One Technology Way, P.O. Box 9106, Norw ood, MA 02062-9106, U.S.A.
Tel: 617/ 329-4700
Fax: 617/ 326-8703
World Wide Web Site: http:/ / w w w .analog.com
© Analog Devices, Inc., 1997
(@ +25؇C and V = +5 V unless otherwise noted)
AD590–SPECIFICATIONS
S
Model
AD 590J
AD 590K
Typ
Min
Typ
Max
Min
Max
Units
ABSOLUT E MAXIMUM RAT INGS
Forward Voltage ( E+ or E–)
Reverse Voltage (E+ to E–)
Breakdown Voltage (Case E+ or E–)
Rated Performance T emperature Range1
Storage T emperature Range1
+44
–20
±200
+150
+155
+300
+44
–20
±200
+150
+155
+300
Volts
Volts
Volts
°C
°C
°C
–55
–65
–55
–65
Lead T emperature (Soldering, 10 sec)
POWER SUPPLY
Operating Voltage Range
+4
+30
+4
+30
Volts
OUT PUT
Nominal Current Output @ +25°C (298.2K)
Nominal T emperature Coefficient
Calibration Error @ +25°C
Absolute Error (Over Rated Performance T emperature Range)
Without External Calibration Adjustment
With +25°C Calibration Error Set to Zero
Nonlinearity
298.2
1
298.2
1
µA
µA/K
°C
؎5.0
؎2.5
؎10
؎5.5
؎2.0
؎0.8
±0.1
±0.1
°C
°C
°C
°C
؎3.0
؎1.5
±0.1
±0.1
Repeatability2
Long-T erm Drift3
°C
Current Noise
40
40
pA/√Hz
Power Supply Rejection
+4 V ≤ VS ≤ +5 V
+5 V ≤ VS ≤ +15 V
+15 V ≤ VS ≤ +30 V
Case Isolation to Either Lead
Effective Shunt Capacitance
Electrical T urn-On T ime
Reverse Bias Leakage Current4
(Reverse Voltage = 10 V)
0.5
0.2
0.1
1010
100
20
0.5
0.2
0.1
1010
100
20
µA/V
µV/V
µA/V
Ω
pF
µs
10
10
pA
PACKAGE OPT IONS
T O-52 (H-03A)
Flatpack (F-2A)
AD590JH
AD590JF
AD590KH
AD590KF
NOT ES
1T he AD590 has been used at –100°C and +200°C for short periods of measurement with no physical damage to the device. However, the absolute errors
specified apply to only the rated performance temperature range.
2Maximum deviation between +25°C readings after temperature cycling between –55°C and +150°C; guaranteed not tested.
3Conditions: constant +5 V, constant +125°C; guaranteed, not tested.
4Leakage current doubles every 10°C.
Specifications subject to change without notice.
Specifications shown in boldface are tested on all production units at final electrical test. Results from those tests are used to calculate outgoing quality levels.
All min and max specifications are guaranteed, although only those shown in boldface are tested on all production units.
REV. B
–2–
AD590
Model
AD 590L
Typ
AD 590M
Typ
Min
Max
Min
Max
Units
ABSOLUT E MAXIMUM RAT INGS
Forward Voltage ( E+ or E–)
Reverse Voltage (E+ to E–)
Breakdown Voltage (Case to E+ or E–)
Rated Performance T emperature Range1
Storage T emperature Range1
+44
–20
±200
+150
+155
+300
+44
–20
±200
+150
+155
+300
Volts
Volts
Volts
°C
°C
°C
–55
–65
–55
–65
Lead T emperature (Soldering, 10 sec)
POWER SUPPLY
Operating Voltage Range
+4
+30
+4
+30
Volts
OUT PUT
Nominal Current Output @ +25°C (298.2K)
Nominal T emperature Coefficient
Calibration Error @ +25°C
Absolute Error (Over Rated Performance T emperature Range)
Without External Calibration Adjustment
With ±25°C Calibration Error Set to Zero
Nonlinearity
298.2
1
298.2
1
µA
µA/K
°C
؎1.0
؎0.5
؎3.0
؎1.6
؎0.4
±0.1
±0.1
؎1.7
؎1.0
؎0.3
±0.1
±0.1
°C
°C
°C
°C
Repeatability2
Long-T erm Drift3
°C
Current Noise
40
40
pA/√Hz
Power Supply Rejection
+4 V ≤ VS ≤ +5 V
+5 V ≤ VS ≤ +15 V
+15 V ≤ VS ≤ +30 V
Case Isolation to Either Lead
Effective Shunt Capacitance
Electrical T urn-On T ime
Reverse Bias Leakage Current4
(Reverse Voltage = 10 V)
0.5
0.2
0.1
1010
100
20
0.5
0.2
0.1
1010
100
20
µA/V
µA/V
µA/V
Ω
pF
µs
10
10
pA
PACKAGE OPT IONS
T O-52 (H-03A)
Flatpack (F-2A)
AD590LH
AD590LF
AD590MH
AD590MF
TEMP ERATURE SCALE CO NVERSIO N EQUATIO NS
5
°C = (°F – 32) K = °C +273.15
9
9
°F = °C + 32
°R = °F +459.7
5
–3–
REV. B
AD590
T he 590H has 60 µ inches of gold plating on its Kovar leads and
Kovar header. A resistance welder is used to seal the nickel cap
to the header. T he AD590 chip is eutectically mounted to the
header and ultrasonically bonded to with 1 MIL aluminum
wire. Kovar composition: 53% iron nominal; 29% ±1% nickel;
17% ± 1% cobalt; 0.65% manganese max; 0.20% silicon max;
0.10% aluminum max; 0.10% magnesium max; 0.10% zirco-
nium max; 0.10% titanium max; 0.06% carbon max.
In the AD590, this PT AT voltage is converted to a PT AT cur-
rent by low temperature coefficient thin-film resistors. T he total
current of the device is then forced to be a multiple of this
PT AT current. Referring to Figure 1, the schematic diagram of
the AD590, Q8 and Q11 are the transistors that produce the
PT AT voltage. R5 and R6 convert the voltage to current. Q10,
whose collector current tracks the colletor currents in Q9 and
Q11, supplies all the bias and substrate leakage current for the
rest of the circuit, forcing the total current to be PT AT . R5 and
R6 are laser trimmed on the wafer to calibrate the device at
+25°C.
T he 590F is a ceramic package with gold plating on its Kovar
leads, Kovar lid, and chip cavity. Solder of 80/20 Au/Sn com-
position is used for the 1.5 mil thick solder ring under the lid.
T he chip cavity has a nickel underlay between the metalization
and the gold plating. T he AD590 chip is eutectically mounted
in the chip cavity at 410°C and ultrasonically bonded to with 1
mil aluminum wire. Note that the chip is in direct contact with
the ceramic base, not the metal lid. When using the AD590 in
die form, the chip substrate must be kept electrically isolated,
(floating), for correct circuit operation.
Figure 2 shows the typical V–I characteristic of the circuit at
+25°C and the temperature extremes.
METALIZATIO N D IAGRAM
Figure 1. Schem atic Diagram
CIRCUIT D ESCRIP TIO N1
T he AD590 uses a fundamental property of the silicon transis-
tors from which it is made to realize its temperature propor-
tional characteristic: if two identical transistors are operated at a
constant ratio of collector current densities, r, then the differ-
ence in their base-emitter voltage will be (kT /q)(In r). Since
both k, Boltzman’s constant and q, the charge of an electron,
are constant, the resulting voltage is directly proportional to
absolute temperature (PT AT ).
Figure 2. V–I Plot
1For a more detailed circuit description see M.P. T imko, “A T wo-T erminal
IC T emperature T ransducer,” IEEE J. Solid State Circuits, Vol. SC-11,
p. 784-788, Dec. 1976.
REV. B
–4–
Understanding the Specifications–AD590
ERRO R VERUS TEMP ERATURE: WITH CALIBRATIO N
ERRO R TRIMMED O UT
EXP LANATIO N O F TEMP ERATURE SENSO R
SP ECIFICATIO NS
Each AD590 is tested for error over the temperature range with
the calibration error trimmed out. T his specification could also
be called the “variance from PT AT ” since it is the maximum
difference between the actual current over temperature and a
PT AT multiplication of the actual current at 25°C. T his error
consists of a slope error and some curvature, mostly at the
temperature extremes. Figure 5 shows a typical AD590K
temperature curve before and after calibration error trimming.
T he way in which the AD590 is specified makes it easy to apply
in a wide variety of different applications. It is important to
understand the meaning of the various specifications and the
effects of supply voltage and thermal environment on accuracy.
T he AD590 is basically a PT AT (proportional to absolute
temperature)1 current regulator. T hat is, the output current is
equal to a scale factor times the temperature of the sensor in
degrees Kelvin. T his scale factor is trimmed to 1 µA/K at the
factory, by adjusting the indicated temperature (i.e., the output
current) to agree with the actual temperature. T his is done with
5 V across the device at a temperature within a few degrees of
+25°C (298.2K). T he device is then packaged and tested for
accuracy over temperature.
CALIBRATIO N ERRO R
At final factory test the difference between the indicated
temperature and the actual temperature is called the calibration
error. Since this is a scale factory error, its contribution to the
total error of the device is PT AT . For example, the effect of the
1°C specified maximum error of the AD590L varies from 0.73°C
at –55°C to 1.42°C at 150°C. Figure 3 shows how an exagger-
ated calibration error would vary from the ideal over temperature.
Figure 5. Effect to Scale Factor Trim on Accuracy
ERRO R VERSUS TEMP ERATURE: NO USER TRIMS
Using the AD590 by simply measuring the current, the total
error is the “variance from PT AT ” described above plus the
effect of the calibration error over temperature. For example the
AD590L maximum total error varies from 2.33°C at –55°C to
3.02°C at 150°C. For simplicity, only the large figure is shown
on the specification page.
NO NLINEARITY
Nonlinearity as it applies to the AD590 is the maximum
deviation of current over temperature from a best-fit straight
line. T he nonlinearity of the AD590 over the –55°C to +150°C
range is superior to all conventional electrical temperature
sensors such as thermocouples. RT Ds and thermistors. Figure 6
shows the nonlinearity of the typical AD590K from Figure 5.
Figure 3. Calibration Error vs. Tem perature
T he calibration error is a primary contributor to maximum total
error in all AD590 grades. However, since it is a scale factor
error, it is particularly easy to trim. Figure 4 shows the most
elementary way of accomplishing this. T o trim this circuit the
temperature of the AD590 is measured by a reference tempera-
ture sensor and R is trimmed so that VT = 1 mV/K at that
temperature. Note that when this error is trimmed out at one
temperature, its effect is zero over the entire temperature range.
In most applications there is a current-to-voltage conversion
resistor (or, as with a current input ADC, a reference) that can
be trimmed for scale factor adjustment.
Figure 6. Nonlinearity
Figure 7A shows a circuit in which the nonlinearity is the major
contributor to error over temperature. T he circuit is trimmed by
adjusting R1 for a 0 V output with the AD590 at 0°C. R2 is then
adjusted for 10 V out with the sensor at 100°C. Other pairs of
temperatures may be used with this procedure as long as they
are measured accurately by a reference sensor. Note that for
+15 V output (150°C) the V+ of the op amp must be greater
than 17 V. Also note that V– should be at least –4 V: if V– is
ground there is no voltage applied across the device.
Figure 4. One Tem perature Trim
1T (°C) = T (K) –273.2; Zero on the Kelvin scale is “absolute zero”; there is no
lower temperature.
REV. B
–5–
AD590
thermal connection. Power source P represents the power
dissipated on the chip. T he rise of the junction temperature, TJ,
above the ambient temperature TA is:
T J −T A = P (θJC + θCA
)
Equation 1
T able I gives the sum of θJC and θCA for several common
thermal media for both the “H” and “F” packages. T he heatsink
used was a common clip-on. Using Equation 1, the temperature
rise of an AD590 “H” package in a stirred bath at +25°C, when
driven with a 5 V supply, will be 0.06°C. However, for the same
conditions in still air the temperature rise is 0.72°C. For a given
supply voltage, the temperature rise varies with the current and
is PT AT . T herefore, if an application circuit is trimmed with
the sensor in the same thermal environment in which it will be
used, the scale factor trim compensates for this effect over the
entire temperature range.
Figure 7A. Two Tem perature Trim
Table I. Therm al Resistances
Medium
θJC + θCA (؇C/Watt) τ (sec)(Note 3)
H
F
H
F
Aluminum Block
Stirred Oil1
30
42
10
60
0.6
1.4
0.1
0.6
Figure 7B. Typical Two-Trim Accuracy
Moving Air2
With Heat Sink
Without Heat Sink
Still Air
With Heat Sink
Without Heat Sink
45
115
–
190
5.0
13.5
–
10.0
VO LTAGE AND TH ERMAL ENVIRO NMENT EFFECTS
T he power supply rejection specifications show the maximum
expected change in output current versus input voltage changes.
T he insensitivity of the output to input voltage allows the use of
unregulated supplies. It also means that hundreds of ohms of
resistance (such as a CMOS multiplexer) can be tolerated in
series with the device.
191
480
–
650
108
60
–
30
1Note: τ is dependent upon velocity of oil; average of several velocities listed
above.
2Air velocity 9 ft./sec.
3T he time constant is defined as the time required to reach 63.2% of an
instantaneous temperature change.
It is important to note that using a supply voltage other than 5 V
does not change the PT AT nature of the AD590. In other
words, this change is equivalent to a calibration error and can be
removed by the scale factor trim (see previous page).
T he time response of the AD590 to a step change in tempera-
ture is determined by the thermal resistances and the thermal
capacities of the chip, CCH, and the case, CC. CCH is about
0.04 watt-sec/°C for the AD590. CC varies with the measured
medium since it includes anything that is in direct thermal
contact with the case. In most cases, the single time constant
exponential curve of Figure 9 is sufficient to describe the time
response, T (t). T able I shows the effective time constant, τ, for
several media.
T he AD590 specifications are guaranteed for use in a low thermal
resistance environment with 5 V across the sensor. Large
changes in the thermal resistance of the sensor’s environment
will change the amount of self-heating and result in changes in
the output which are predictable but not necessarily desirable.
T he thermal environment in which the AD590 is used deter-
mines two important characteristics: the effect of self heating
and the response of the sensor with time.
Figure 8. Therm al Circuit Model
Figure 8 is a model of the AD590 which demonstrates these
characteristics. As an example, for the T O-52 package, θJC is
the thermal resistance between the chip and the case, about
26°C/watt. θCA is the thermal resistance between the case and
the surroundings and is determined by the characteristics of the
Figure 9. Tim e Response Curve
REV. B
–6–
Applying the AD590
GENERAL AP P LICATIO NS
Figure 12. Differential Measurem ents
Figure 10. Variable Scale Display
Figure 10 demonstrates the use of a low cost Digital Panel
Meter for the display of temperature on either the Kelvin,
Celsius or Fahrenheit scales. For Kelvin temperature Pins 9, 4
and 2 are grounded; and for Fahrenheit temperature Pins 4 and
2 are left open.
desired temperature difference. For example, the inherent
offset between the two devices can be trimmed in. If V+ and
V– are radically different, then the difference in internal
dissipation will cause a differential internal temperature rise.
T his effect can be used to measure the ambient thermal
resistance seen by the sensors in applications such as fluid level
detectors or anemometry.
T he above configuration yields a 3 digit display with 1°C or 1°F
resolution, in addition to an absolute accuracy of ±2.0°C over
the –55°C to +125°C temperature range if a one-temperature
calibration is performed on an AD590K, L, or M.
Figure 13. Cold J unction Com pensation Circuit for
Type J Therm ocouple
Figure 13 is an example of a cold junction compensation circuit
for a T ype J T hermocouple using the AD590 to monitor the
reference junction temperature. T his circuit replaces an ice-bath
as the thermocouple reference for ambient temperatures
between +15°C and +35°C. T he circuit is calibrated by
adjusting RT for a proper meter reading with the measuring
junction at a known reference temperature and the circuit near
+25°C. Using components with the T Cs as specified in Figure
13, compensation accuracy will be within ±0.5°C for circuit
temperatures between +15°C and +35°C. Other thermocouple
types can be accommodated with different resistor values. Note
that the T Cs of the voltage reference and the resistors are the
primary contributors to error.
Figure 11. Series & Parallel Connection
Connecting several AD590 units in series as shown in Figure 11
allows the minimum of all the sensed temperatures to be
indicated. In contrast, using the sensors in parallel yields the
average of the sensed temperatures.
T he circuit of Figure 12 demonstrates one method by which
differential temperature measurements can be made. R1 and R2
can be used to trim the output of the op amp to indicate a
REV. B
–7–
AD590
Figure 14. 4 m A-to-20 m A Current Transm itter
Figure 14 is an example of a current transmitter designed to be
used with 40 V, 1 kΩ systems; it uses its full current range of
4 mA-to-20 mA for a narrow span of measured temperatures. In
this example the 1 µA/K output of the AD590 is amplified to
1 mA/°C and offset so that 4 mA is equivalent to 17°C and
20 mA is equivalent to 33°C. RT is trimmed for proper reading
at an intermediate reference temperature. With a suitable choice
of resistors, any temperature range within the operating limits of
the AD590 may be chosen.
Figure 16. DAC Set Point
low) in 0.2°C steps. T he comparator is shown with 1°C
hysteresis which is usually necessary to guard-band for extrane-
ous noise; omitting the 5.1 MΩ resistor results in no hysteresis.
Figure 15. Sim ple Tem perature Control Circuit
Figure 15 is an example of a variable temperature control circuit
(thermostat) using the AD590. RH and RL are selected to set the
high and low limits for RSET. RSET could be a simple pot, a
calibrated multiturn pot or a switched resistive divider. Power-
ing the AD590 from the 10 V reference isolates the AD590 from
supply variations while maintaining a reasonable voltage (~7 V)
across it. Capacitor C1 is often needed to filter extraneous noise
from remote sensors. RB is determined by the β of the power
transistor and the current requirements of the load.
Figure 17. AD590 Driven from CMOS Logic
T he voltage compliance and the reverse blocking characteristic
of the AD590 allows it to be powered directly from +5 V
CMOS logic. T his permits easy multiplexing, switching or
pulsing for minimum internal heat dissipation. In Figure 17 any
AD590 connected to a logic high will pass a signal current
through the current measuring circuitry while those connected
to a logic zero will pass insignificant current. T he outputs used
to drive the AD590s may be employed for other purposes, but
the additional capacitance due to the AD590 should be taken
into account.
Figure 16 shows the AD590 can be configured with an 8-bit
DAC to produce a digitally controlled set point. T his particular
circuit operates from 0°C (all inputs high) to +51°C (all inputs
REV. B
–8–
AD590
Figure 18. Matrix Multiplexer
CMOS Analog Multiplexers can also be used to switch AD590
current. Due to the AD590’s current mode, the resistance of
such switches is unimportant as long as 4 V is maintained across
the transducer. Figure 18 shows a circuit which combines the
principal demonstrated in Figure 17 with an 8-channel CMOS
Multiplexer. T he resulting circuit can select one of eighty
sensors over only 18 wires with a 7-bit binary word. T he inhibit
input on the multiplexer turns all sensors off for minimum
dissipation while idling.
Figure 19. 8-Channel Multiplexer
Figure 19 demonstrates a method of multiplexing the AD590 in
the two-trim mode (Figure 7). Additional AD590s and their
associated resistors can be added to multiplex up to 8 channels
of ±0.5°C absolute accuracy over the temperature range of
–55°C to +125°C. T he high temperature restriction of +125°C
is due to the output range of the op amps; output to +150°C
can be achieved by using a +20 V supply for the op amp.
REV. B
–9–
AD590
O UTLINE D IMENSIO NS
AND P IN D ESIGNATIO NS
D imensions shown in inches and (mm).
FLATP ACK P ACKAGE: D ESIGNATIO N “ F’’
TO -52 P ackage: D esignation “ H ’’
REV. B
–10–
–11–
–12–
相关型号:
AD590JFZ
Analog Temperature Sensor, ANALOG TEMP SENSOR-CURRENT, 298.2uA, RECTANGULAR, THROUGH HOLE MOUNT, CERAMIC, FP-2
ADI
©2020 ICPDF网 联系我们和版权申明