AD7418_15 [ADI]
10-Bit Digital Temperature Sensor;型号: | AD7418_15 |
厂家: | ADI |
描述: | 10-Bit Digital Temperature Sensor |
文件: | 总24页 (文件大小:396K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
10-Bit Digital Temperature Sensor
(AD7416) and Four Single-Channel ADCs
AD7416/AD7417/AD7418
FUNCTIONAL BLOCK DIAGRAMS
FEATURES
10-bit ADC with 15 μs and 30 μs conversion times
Single and 4 single-ended analog input channels
On-chip temperature sensor: −40°C to +125°C
On-chip track-and-hold
10-BIT
BAND GAP
TEMPERATURE
SENSOR
ANALOG-TO-DIGITAL
CONVERTER
AD7416
TEMPERATURE
VALUE
REGISTER
Overtemperature indicator
SETPOINT
COMPARATOR
Automatic power-down at the end of a conversion
Wide operating supply range: 2.7 V to 5.5 V
I2C-compatible serial interface
Selectable serial bus address allows connection of up to 8
AD7416/AD7417 devices to a single bus
AD7416 is a superior replacement for LM75
T
SETPOINT
OTI
REGISTER
ADDRESS
POINTER
REGISTER
8
V
DD
T
SETPOINT
HYST
REGISTER
3
4
OTI
FAULT
QUEUE
COUNTER
CONFIGURATION
REGISTER
GND
SDA
SCL
7
6
5
A0
A1
A2
1
2
SERIAL BUS
INTERFACE
APPLICATIONS
Data acquisition with ambient temperature monitoring
Industrial process control
Automotive
Figure 1. AD7416
REF
5
V
DD
IN
14
Battery-charging applications
Personal computers
T
SETPOINT
REGISTER
OTI
A > B
A
B
4
OTI
TEMP
SENSOR
CHARGE
DISTRIBUTION
DAC
DATA OUT
REF
2.5V
GENERAL DESCRIPTION
The AD7417 and AD7418 are 10-bit, 4-channel and single-channel
ADCs with an on-chip temperature sensor that can operate from a
single 2.7 V to 5.5 V power supply. The devices contain a 15 μs
successive approximation converter, a 5-channel multiplexer, a
temperature sensor, a clock oscillator, a track-and-hold, and a
reference (2.5 V). The AD7416 is a temperature-monitoring only
device in an 8-lead package.
3
2
SCL
SDA
7
A
A
A
A
IN1
CONTROL
LOGIC
2
I C
CLOCK
INTERFACE
8
9
IN2
IN3
IN4
SAMPLING
MUX
CAPACITOR
10
AD7417
V
BALANCE
1
16
NC NC
NC = NO CONNECT
6
15
13
12
11
A2
GND
CONVST
A0
A1
The temperature sensor on the parts can be accessed via multip-
lexer Channel 0. When Channel 0 is selected and a conversion
is initiated, the resulting ADC code at the end of the conversion
gives a measurement of the ambient temperature (±1°C @ 25°C).
On-chip registers can be programmed with high and low tempera-
ture limits, and an open-drain overtemperature indicator (OTI)
output is provided, which becomes active when a programmed
limit is exceeded.
Figure 2. AD7417
V
REF
6
DD
7
IN
T
SETPOINT
B
OTI
REGISTER
A > B
A
3
OTI
TEMP
SENSOR
CHARGE
DISTRIBUTION
DAC
DATA OUT
REF
2.5V
2
1
SCL
SDA
A configuration register allows programming of the sense of the
OTI output (active high or active low) and its operating mode
(comparator or interrupt). A programmable fault queue counter
allows the number of out-of-limit measurements that must
occur before triggering the OTI output to be set to prevent
spurious triggering of the OTI output in noisy environments.
5
A
MUX
IN
CONTROL
LOGIC
2
I C
CLOCK
INTERFACE
SAMPLING
CAPACITOR
AD7418
V
BALANCE
4
8
GND
CONVST
Figure 3. AD7418
Rev. I
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registeredtrademarks arethe property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700 www.analog.com
Fax: 781.461.3113 ©1998–2010 Analog Devices, Inc. All rights reserved.
AD7416/AD7417/AD7418
TABLE OF CONTENTS
Features .............................................................................................. 1
On-Chip Reference .................................................................... 11
Temperature Measurement....................................................... 12
Internal Register Structure........................................................ 12
Serial Bus Interface..................................................................... 14
OTI Output ................................................................................. 17
Fault Queue................................................................................. 17
Power-On Defaults..................................................................... 17
Operating Modes........................................................................ 17
Applications....................................................................................... 1
General Description......................................................................... 1
Functional Block Diagrams............................................................. 1
Revision History ............................................................................... 2
Product Highlights ........................................................................... 3
Specifications..................................................................................... 4
AD7417/AD7418 Specifications................................................. 4
AD7416 Specifications................................................................. 6
Absolute Maximum Ratings............................................................ 7
ESD Caution.................................................................................. 7
Pin Configurations and Function Descriptions ........................... 8
Terminology .................................................................................... 10
Theory of Operation ...................................................................... 11
Circuit Information.................................................................... 11
Converter Details........................................................................ 11
Typical Connection Diagram ................................................... 11
Analog Inputs.............................................................................. 11
CONVST
Start Mode................................................................. 18
Applications Information.............................................................. 19
Supply Decoupling ..................................................................... 19
Power-On Reset.......................................................................... 19
Mounting the AD7416/AD7417/AD7418 .............................. 19
Fan Controller............................................................................. 19
Thermostat.................................................................................. 19
System with Multiple AD7416 Devices................................... 20
Outline Dimensions....................................................................... 21
Ordering Guide .......................................................................... 23
REVISION HISTORY
11/10—Rev. H to Rev. I
Changes to Figure 19...................................................................... 16
2/09—Rev. G to Rev. H
8/04—Data Sheet Changed from Rev. F to Rev. G
Changes to Figure 12...................................................................... 12
Changes to Reading Data from the AD7416/AD7417/AD7418
Section.............................................................................................. 13
Changes to Power-On-Reset section ........................................... 14
Updated Format..................................................................Universal
Changes to Data Sheet Title, Figure 2 and Figure 3..................... 1
Moved Product Highlights Section................................................ 3
Changes to Table 1............................................................................ 4
Changes to Endnote 1, Table 2........................................................ 6
Added Figure 5 Caption................................................................... 7
Changes to Table 4............................................................................ 8
Changes to Table 5 and Table 6....................................................... 9
Changes to On-Chip Reference Section...................................... 11
Changes to Figure 13...................................................................... 12
Changes to Table 8 and Table 10................................................... 13
Changes to Figure 15, Figure 16, and Figure 17 ......................... 15
Changes to Reading Data From the AD7416/AD7417/AD7418
Section, Figure 18, and Figure 19 ................................................. 16
Change to Mode 1 .......................................................................... 17
7/03—Data Sheet Changed from Rev. E to Rev. F
Updated Features...............................................................................1
Updated Specifications .....................................................................3
Updated Absolute Maximum Ratings ............................................6
Updated Ordering Guide .................................................................6
Updated Product Highlights............................................................7
Updated Circuit Information...........................................................7
Updated Temperature Measurement section ................................9
10/02—Data Sheet Changed from Rev. D to Rev. E
Edits to Specifications Headings .....................................................2
Added Temperature Measurement section....................................8
Edits to Serial Bus Address section.............................................. 10
Edits to Figure 11............................................................................ 12
CONVST
Changes to Figure 22 Caption and
Pin Mode
Section.............................................................................................. 18
Moved Figure 21 and Figure 22 .................................................... 18
Changes to Power-On Reset Section............................................ 19
Updated Outline Dimensions....................................................... 21
Changes to Ordering Guide .......................................................... 23
CONVST
Edits to
Pin Mode section ........................................... 14
Edits to Power-On-Reset section ................................................. 14
Addition of Figures 16 and 17 ...................................................... 15
Updated Outlines ........................................................................... 16
Rev. I | Page 2 of 24
AD7416/AD7417/AD7418
An I2C® compatible serial interface allows the AD7416/AD7417/
AD7418 registers to be written to and read back. The three
LSBs of the AD7416/AD7417 serial bus address can be selected,
which allows up to eight AD7416/AD7417 devices to be connected
to a single bus.
made. The measurable temperature range is −40°C to
+125°C. An overtemperature indicator is implemented by
carrying out a digital comparison of the ADC code for
Channel 0 (temperature sensor) with the contents of the
on-chip TOTI setpoint register.
2. The AD7417 offers a space-saving, 10-bit analog-to-digital
solution with four external voltage input channels, an on-
chip temperature sensor, an on-chip reference, and a clock
oscillator.
3. The automatic power-down feature enables the AD7416/
AD7417/AD7418 to achieve superior power performance.
At slower throughput rates, the part can be programmed to
operate in a low power shutdown mode, allowing further
savings in power consumption.
The AD7417 is available in a narrow body, 0.15 inch, 16-lead,
small outline package (SOIC) and in a 16-lead, thin shrink,
small outline package (TSSOP). The AD7416 and AD7418 are
available in 8-lead SOIC and MSOP packages.
PRODUCT HIGHLIGHTS
1. The AD7416/AD7417/AD7418 have an on-chip temperature
sensor that allows an accurate measurement of the ambient
temperature (±1°C @ 25°C, ±2°C overtemperature) to be
Rev. I | Page 3 of 24
AD7416/AD7417/AD7418
SPECIFICATIONS
AD7417/AD7418 SPECIFICATIONS
VDD = 2.7 V to 5.5 V, GND = 0 V, REFIN = 2.5 V, unless otherwise noted.
Table 1.
Parameter
DC ACCURACY
Resolution
Minimum Resolution for Which No
Missing Codes Are Guaranteed
A Version
B Version1
Unit
Test Conditions/Comments
Any channel
10
10
10
10
Bits
Bits
Relative Accuracy2
Differential Nonlinearity2
Gain Error2
1
1
3
10
0.6
4
1
1
3
10
0.6
4
LSB max
LSB max
LSB max
LSB max
LSB max
LSB max
LSB max
This specification is typical for VDD of 3.6 V to 5.5 V
This specification is typical for VDD of 3.6 V to 5.5 V
External reference
Internal reference
AD7417 only
Gain Error Match2
Offset Error2
Offset Error Match2
ANALOG INPUTS
Input Voltage Range
0.7
0.7
AD7417 only
VREF
0
VREF
0
V max
V min
Input Leakage Current3
Input Capacitance
1
10
1
10
μA max
pF max
TEMPERATURE SENSOR1
Measurement Error
Ambient Temperature 25°C
TMIN to TMAX
Temperature Resolution
2
3
1/4
1
2
1/4
°C max
°C max
°C/LSB
CONVERSION RATE
Track-and-Hold Acquisition Time4
Conversion Time
400
400
ns max
Source impedance < 10 Ω
Temperature Sensor
Channel 1 to Channel 4
REFERENCE INPUT5,6
REFIN Input Voltage Range
30
15
30
15
μs max
μs max
Typically 27 μs
Typically 10 μs
2.625
2.375
40
2.625
2.375
40
V max
V min
kΩ min
pF max
2.5 V + 5%
2.5 V − 5%
Input Impedance
Input Capacitance
10
10
ON-CHIP REFERENCE
Reference Error6
Temperature Coefficient6
Nominal 2.5 V
25
80
25
80
mV max
ppm/°C typ
DIGITAL INPUTS
Input High Voltage, VIH
Input Low Voltage, VIL
Input Leakage Current
DIGITAL OUTPUTS
VDD × 0.7
VDD × 0.3
1
VDD × 0.7
VDD × 0.3
1
V min
V max
μA max
Output Low Voltage, VOL
Output High Current
0.4
1
0.4
1
V max
μA max
IOL = 3 mA
VOH = 5 V
Rev. I | Page 4 of 24
AD7416/AD7417/AD7418
Parameter
A Version
B Version1
Unit
Test Conditions/Comments
POWER REQUIREMENTS
VDD
5.5
2.7
5.5
2.7
V max
V min
For specified performance
Logic inputs = 0 V or VDD
IDD
Normal Operation
Power-Down
600
1.5
600
1.5
μA max
μA max
0.7 ꢀA typically
Auto Power-Down Mode
10 SPS Throughput Rate
1 kSPS Throughput Rate
10 kSPS Throughput Rate
Power-Down
VDD = 3 V; see the Operating Modes section
6
6
μW typ
μW typ
μW typ
μW max
60
600
3
60
600
3
Typically 0.15 μW
1 B Version applies to AD7417 only with temperature range of −40°C to +85°C. A Version temperature range is −40°C to +125°C. For VDD = 2.7 V, TA = 85°C maximum and
temperature sensor measurement error = 3°C maximum.
2 See the Terminology section.
3 Refers to the input current when the part is not converting. Primarily due to reverse leakage current in the ESD protection diodes.
4 Sample tested during initial release and after any redesign or process change that may affect this parameter.
5 On-chip reference shuts down when an external reference is applied.
6 The accuracy of the temperature sensor is affected by reference tolerance.
Rev. I | Page 5 of 24
AD7416/AD7417/AD7418
AD7416 SPECIFICATIONS
VDD = 2.7 V to 5.5 V, GND = 0 V, REFIN = 2.5 V, unless otherwise noted.
Table 2.
Parameter
Min
Typ
Max
2.0
Unit
°C
Test Conditions/Comments
TEMPERATURE SENSOR AND ADC
Accuracy
TA = −25°C to + 100°C
(VDD = 3 V minimum)1
TA = −40°C to + 125°C
(VDD = 3 V minimum)1
3.0
°C
Resolution
10
Bits
μs
μs
ms
mA
μA
μA
°C
Temperature Conversion Time
Update Rate, tR
OTI Delay
40
400
1 × tR
6 × tR
1.0
600
1.5
Depends on fault queue setting
I2C active
I2C inactive
Supply Current
350
0.2
80
Shutdown mode
TOTI Default Temperature
THYST Default Temperature
DIGITAL INPUTS
75
°C
Input High Voltage, VIH
Input Low Voltage, VIL
Input High Current, IIH
Input Low Current, IIL
Input Capacitance, CIN
VDD × 0.7
−0.3
VDD + 0.5
VDD × 0.3
+1.0
V
V
μA
μA
pF
+0.005
−0.005
20
VIN = 5 V
VIN = 0 V
All digital inputs
−1.0
DIGITAL OUTPUTS
Output Low Voltage, VOL
Output High Current
Output Fall Time, tf
OS Output Low Voltage, VOL
AC ELECTRICAL CHARACTERISTICS2
Serial Clock Period, t1
Data In Setup Time to SCL High, t2
Data Out Stable after SCL Low, t3
SDA Low Setup Time to SCL Low
(Start Condition), t4
0.4
1
250
0.8
V
IOL = 3 mA
VOH = 5 V
CL = 400 pF, IO = 3 mA
IOUT = 4 mA
μA
ns
V
AD7416/AD7417/AD7418
See Figure 4
See Figure 4
2.5
50
0
μs
ns
ns
See Figure 4
50
50
ns
See Figure 4
SDA High Hold Time after SCL High
(Stop Condition), t5
SDA and SCL Fall Time, t6
ns
ns
See Figure 4
See Figure 4
300
1 For VDD = 2.7 V to 3 V, TA maximum = 85°C and temperature sensor measurement error = 3°C maximum.
2 Sample tested during initial release and after any redesign or process change that may affect this parameter.
t1
SCL
t4
t2
t5
SDA
DATA IN
t3
SDA
DATA OUT
t6
Figure 4. Diagram for Serial Bus Timing
Rev. I | Page 6 of 24
AD7416/AD7417/AD7418
ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Table 3.
Parameter
Rating
VDD to AGND
VDD to DGND
−0.3 V to +7 V
−0.3 V to +7 V
Analog Input Voltage to AGND
AIN1 to AIN4
−0.3 V to VDD + 0.3 V
−0.3 V to VDD + 0.3 V
−0.3 V to VDD + 0.3 V
−0.3 V to VDD + 0.3 V
REF
V
IN
DD
Reference Input Voltage to AGND1
Digital Input Voltage to DGND
Digital Output Voltage to DGND
Operating Temperature Range
A Version
BAT81
AD7417
Figure 5. Diode Connection
−40°C to +125°C
−40°C to +85°C
−65°C to +150°C
150°C
450 mW
120°C/W
B Version
Storage Temperature Range
Junction Temperature
TSSOP, Power Dissipation
θJA Thermal Impedance
Lead Temperature, Soldering
Vapor Phase (60 sec)
ESD CAUTION
260°C
215°C
Infrared (15 sec)
220°C
16-Lead SOIC Package, Power Dissipation
θJA Thermal Impedance
Lead Temperature, Soldering
Vapor Phase (60 sec)
450 mW
100°C/W
215°C
Infrared (15 sec)
220°C
8-Lead SOIC Package, Power Dissipation
θJA Thermal Impedance
Lead Temperature, Soldering
Vapor Phase (60 sec)
450 mW
157°C/W
215°C
Infrared (15 sec)
220°C
MSOP Package, Power Dissipation
θJA Thermal Impedance
Lead Temperature, Soldering
Vapor Phase (60 sec)
450 mW
206°C/W
215°C
220°C
Infrared (15 sec)
1 If the reference input voltage is likely to exceed VDD by more than 0.3 V (for
example, during power-up) and the reference is capable of supplying 30 mA
or more, it is recommended to use a clamping diode between the REFIN pin
and the VDD pin. Figure 5 shows how the diode should be connected.
Rev. I | Page 7 of 24
AD7416/AD7417/AD7418
PIN CONFIGURATIONS AND FUNCTION DESCRIPTIONS
NC
SDA
SCL
OTI
1
2
3
4
5
6
7
8
16 NC
15 CONVST
14
V
DD
AD7417
13 A0
12 A1
11 A2
TOP VIEW
(Not to Scale)
REF
IN
GND
A
A
10
9
A
A
IN1
IN2
IN4
IN3
NC = NO CONNECT
Figure 6. AD7417 Pin Configuration (SOIC/TSSOP)
Table 4. AD7417 Pin Function Descriptions
Pin No. Mnemonic Description
1, 16
NC
No Connection. Do not connect anything to this pin.
2
3
4
SDA
SCL
OTI
Digital I/O. Serial bus bidirectional data. Push-pull output.
Digital Input. Serial bus clock.
This pin is a logic output. The overtemperature indicator (OTI) is set if the result of a conversion on Channel 0
(temperature sensor) is greater than an 8-bit word in the TOTI setpoint register. The signal is reset at the end of a
serial read operation. Open-drain output.
5
6
REFIN
GND
Reference Input. An external 2.5 V reference can be connected to the AD7417 at this pin. To enable the on-chip
reference, the REFIN pin should be tied to GND. If an external reference is connected to the AD7417, the internal
reference shuts down.
Ground reference for track-and-hold, comparator and capacitor DAC, and digital circuitry.
7 to 10 AIN1 to AIN4
Analog Input Channels. The AD7417 has four analog input channels. The input channels are single-ended with
respect to GND. The input channels can convert voltage signals in the range of 0 V to VREF. A channel is selected by
writing to the configuration register of the AD7417.
11
12
13
14
15
A2
A1
A0
VDD
Digital Input. This is the highest programmable bit of the serial bus address.
Digital Input. This is the middle programmable bit of the serial bus address.
Digital Input. This is the lowest programmable bit of the serial bus address.
Positive Supply Voltage, 2.7 V to 5.5 V.
Logic Input Signal. Convert start signal. The rising edge of this signal fully powers up the part. The power-up time
for the part is 4 μs. If the CONVST pulse is greater than 4 μs, the falling edge of CONVST places the track-and-hold
mode into hold mode and initiates a conversion. If the pulse is less than 4 μs, an internal timer ensures that the
track-and-hold does not go into hold, and conversion is not initiated until the power-up time has elapsed. The
track-and-hold goes into track mode again at the end of conversion (see the Operating Modes section).
CONVST
Rev. I | Page 8 of 24
AD7416/AD7417/AD7418
SDA
SCL
OTI
1
2
3
4
8
7
6
5
V
SDA
SCL
OTI
1
2
3
4
8
7
6
5
CONVST
DD
AD7416
AD7418
A0
A1
A2
V
DD
REF
TOP VIEW
(Not to Scale)
TOP VIEW
(Not to Scale)
IN
GND
GND
A
IN
Figure 7. AD7416 Pin Configuration (SOIC/MSOP)
Figure 8. AD7418 Pin Configuration (SOIC/MSOP)
Table 5. AD7416 Pin Function Descriptions
Pin No. Mnemonic Description
1
2
3
SDA
SCL
OTI
Digital I/O. Serial bus bidirectional data. Push-pull output.
Digital Input. Serial bus clock.
This pin is a logic output. The OTI is set if the result of a conversion on Channel 0 (temperature sensor) is greater
than an 8-bit word in the TOTI setpoint register. The signal is reset at the end of a serial read operation. Open-drain
output.
4
5
6
7
8
GND
A2
A1
A0
VDD
Ground reference for track-and-hold, comparator and capacitor DAC, and digital circuitry.
Digital Input. This is the highest programmable bit of the serial bus address.
Digital Input. This is the middle programmable bit of the serial bus address.
Digital Input. This is the lowest programmable bit of the serial bus address.
Positive Supply Voltage, 2.7 V to 5.5 V.
Table 6. AD7418 Pin Function Descriptions
Pin No. Mnemonic Description
1
2
3
SDA
SCL
OTI
Digital I/O. Serial bus bidirectional data. Push-pull output.
Digital Input. Serial bus clock.
This is a logic output. The OTI is set if the result of a conversion on Channel 0 (temperature sensor) is greater than
an 8-bit word in the TOTI setpoint register. The signal is reset at the end of a serial read operation. Open-drain
output.
4
5
GND
AIN
Ground reference for track-and-hold, comparator and capacitor DAC, and digital circuitry.
Analog Input Channel. The input channel is single-ended with respect to GND. The input channel can convert
voltage signals in the range of 0 V to VREF. The analog input channel is selected by writing to the configuration
register of the AD7418 and choosing Channel 4.
6
REFIN
Reference Input. An external 2.5 V reference can be connected to the AD7418 at this pin. To enable the on-chip
reference, the REFIN pin should be tied to GND. If an external reference is connected to the AD7418, the internal
reference shuts down.
7
8
VDD
CONVST
Positive Supply Voltage, 2.7 V to 5.5 V.
Logic Input Signal. Convert start signal. The rising edge of this signal fully powers up the part. The power-up time
CONVST
CONVST
places the track-and-hold
for the part is 4 μs. If the
pulse is greater than 4 μs, the falling edge of
mode into hold mode and initiates a conversion. If the pulse is less than 4 μs, an internal timer ensures that the
track-and-hold does not go into hold, and conversion is not initiated until the power-up time has elapsed. The
track-and-hold goes into track mode again at the end of conversion (see the Operating Modes section).
Rev. I | Page 9 of 24
AD7416/AD7417/AD7418
TERMINOLOGY
Gain Error Match
This is the difference in gain error between any two channels.
Relative Accuracy
Relative accuracy or endpoint nonlinearity is the maximum
deviation from a straight line passing through the endpoints of
the ADC transfer function.
Track-and-Hold Acquisition Time
Track-and-hold acquisition time is the time required for the
output of the track-and-hold amplifier to reach its final value,
within ±± LSB, after the end of conversion (the point at which
the track-and-hold returns to track mode). It also applies to
situations where a change in the selected input channel takes
place or where there is a step input change on the input voltage
applied to the selected AIN input of the AD7417 or AD7418. It
means that the user must wait for the duration of the track-and-
hold acquisition time after the end of conversion, or after a
channel change or step input change to AIN before starting
another conversion, to ensure that the part operates to
specification.
Differential Nonlinearity
This is the difference between the measured and the ideal 1 LSB
change between any two adjacent codes in the ADC.
Offset Error
This is the deviation of the first code transition (0000…000) to
(0000…001) from the ideal, that is, GND + 1 LSB.
Offset Error Match
This is the difference in offset error between any two channels.
Gain Error
This is the deviation of the last code transition (1111…110) to
(1111…111) from the ideal, that is, VREF − 1 LSB, after the
offset error has been adjusted out.
Rev. I | Page 10 of 24
AD7416/AD7417/AD7418
THEORY OF OPERATION
external reference is used, a 10 μF capacitor should be connected
between REFIN and GND. SDA and SCL form the 2-wire I2C
compatible interface. For applications where power consump-
tion is of concern, the automatic power-down at the end of a
conversion should be used to improve power performance (see
the Operating Modes section.)
CIRCUIT INFORMATION
The AD7417 and AD7418 are single-channel and four-channel,
15 μs conversion time, 10-bit ADCs with on-chip temperature
sensor, reference, and serial interface logic functions on a single
chip. The AD7416 has no analog input channel and is intended
for temperature measurement only. The ADC section consists
of a conventional successive approximation converter based
around a capacitor DAC. The AD7416, AD7417, and AD7418
are capable of running on a 2.7 V to 5.5 V power supply, and the
AD7417 and AD7418 accept an analog input range of 0 V to
+VREF. The on-chip temperature sensor allows an accurate
measurement of the ambient device temperature to be made.
The working measurement range of the temperature sensor is
−40°C to +125°C. The parts require a 2.5 V reference that can
be provided from the part’s own internal reference or from an
external reference source.
SUPPLY
2.7V TO 5.5V
2-WIRE
+
+
SERIAL
INTERFACE
10µF
0.1µF
V
DD
SCL
SDA
A
A
A
IN1
IN2
IN3
0V TO 2.5V
INPUT
CONVST
OTI
MICROCONTROLLER/
MICROPROCESSOR
A
IN4
AD7417
A0
A1
A2
GND
REF
IN
OPTIONAL
EXTERNAL
REFERENCE
AD780/
REF192
10µF FOR
EXTERNAL
REFERENCE
CONVERTER DETAILS
Conversion is initiated on the AD7417/AD7418 by pulsing the
CONVST
input. The conversion clock for the part is internally
Figure 9. Typical AD7417 Connection Diagram
generated so that no external clock is required except when
reading from and writing to the serial port. The on-chip track-
and-hold goes from track mode to hold mode, and the conversion
CONVST
ANALOG INPUTS
Figure 10 shows an equivalent circuit of the analog input
structure of the AD7417 and AD7418. The two diodes, D1
and D2, provide ESD protection for the analog inputs. Care
must be taken to ensure that the analog input signal never
exceeds the supply rails by more than 200 mV to prevent these
diodes from becoming forward-biased and start conducting
current into the substrate. The maximum current these diodes
can conduct without causing irreversible damage to the part is
20 mA. Capacitor C2 in Figure 10 is typically about 4 pF and
can primarily be attributed to pin capacitance. Resistor R1 is a
lumped component made up of the on resistance of a multiplexer
and a switch. This resistor is typically about 1 kΩ. Capacitor C1
is the ADC sampling capacitor and has a capacitance of 3 pF.
sequence is started on the falling edge of the
signal.
A conversion is also initiated in the automatic conversion mode
every time a read or write operation to the AD7416/AD7417/
AD7418 takes place. In this case, the internal clock oscillator
(which runs the automatic conversion sequence) is restarted
at the end of the read or write operation. The track-and-hold
goes into hold mode approximately 3 μs after the read or write
operation is complete, and a conversion is then initiated. The
result of the conversion is available either 15 μs or 30 μs later,
depending on whether an analog input channel or the tempera-
ture sensor is selected. The track-and-hold acquisition time of
the AD7417/AD7418 is 400 ns.
V
DD
A temperature measurement is made by selecting the Channel 0
of the on-chip mux and carrying out a conversion on this
channel. A conversion on Channel 0 takes 30 μs to complete.
Temperature measurement is explained in the Temperature
Measurement section.
D1
C1
3pF
R1
1kΩ
V
A
BALANCE
IN
C2
4pF
D2
CONVERT PHASE: SWITCH OPEN
TRACK PHASE: SWITCH CLOSED
The on-chip reference is not available to the user, but REFIN can
be overdriven by an external reference source (2.5 V only).
Figure 10. Equivalent Analog Input Circuit
All unused analog inputs should be tied to a voltage within the
nominal analog input range to avoid noise pickup. For
minimum power consumption, the unused analog inputs
should be tied to GND.
ON-CHIP REFERENCE
The AD7417/AD7418 have an on-chip 1.2 V band gap reference
that is amplified by a switched capacitor amplifier to give an
output of 2.5 V. The amplifier is only powered up at the start of
the conversion phase and is powered down at the end of the
conversion. The on-chip reference is selected by connecting the
REFIN pin to analog ground, which causes SW1 (see Figure 11) to
open and the reference amplifier to power up during a conver-
sion. Therefore, the on-chip reference is not available externally.
TYPICAL CONNECTION DIAGRAM
Figure 9 shows a typical connection diagram for the AD7417.
Using the A0, A1, and A2 pins allows the user to select from up
to eight AD7417 devices on the same serial bus, if desired. An
external 2.5 V reference can be connected at the REFIN pin. If an
Rev. I | Page 11 of 24
AD7416/AD7417/AD7418
An external 2.5 V reference can be connected to the REFIN pin.
This has the effect of shutting down the on-chip reference
circuitry.
The temperature resolution of the ADC is 0.25°C, which corres-
ponds to 1 LSB of the ADC. The ADC can theoretically measure a
temperature span of 255°C; the guaranteed temperature range is
−40°C to +125°C. The result of the conversion is stored in the
temperature value register (0x00) as a 16-bit word. The 10 MSBs
of this word store the temperature measurement (see Table 9
and Table 10).
REF
IN
EXTERNAL
REFERENCE
DETECT
1.2V
The temperature conversion formulas using the 10 MSBs of the
temperature value register are
SW1
1.2V
Positive Temperature = ADC Code/4
(1)
(2)
26kΩ
24kΩ
BUFFER
2.5V
Negative Temperature = (ADC Code − 512)/4
The MSB is removed from ADC Code in Equation 2.
INTERNAL REGISTER STRUCTURE
Figure 11. On-Chip Reference
The AD7417/AD7418 have seven internal registers, as shown in
Figure 13. Six of these are data registers and one is an address
pointer register. The AD7416 has five internal registers (the
ADC and Config2 registers are not applicable to the AD7416).
TEMPERATURE MEASUREMENT
A common method of measuring temperature is to exploit the
negative temperature coefficient of a diode, or the base-emitter
voltage of a transistor, operated at a constant current. Unfortu-
nately, this technique requires calibration to null out the effect
of the absolute value of VBE, which varies from device to device.
TEMPERATURE
VALUE
REGISTER
(READ-ONLY
ADDRESS 0x00)
CONFIGURATION
REGISTER
(READ/WRITE
ADDRESS 0x01)
The technique used in the AD7416/AD7417/AD7418 is to
measure the current change in VBE when the device is operated
at two different currents.
T
SETPOINT
HYST
REGISTER
(READ/WRITE
ADDRESS 0x02)
This is given by
ADDRESS POINTER
REGISTER
(SELCTS DATA REGISTER
FOR READ/WRITE)
ΔVBE = KT /q×1n
where:
K is Boltzmann’s constant.
(
N
)
T
SETPOINT
OTI
REGISTER
ADDRESS
(READ/WRITE
ADDRESS 0x03)
q is the charge on the electron (1.6 × 10−19 Coulombs).
T is the absolute temperature in Kelvins.
N is the ratio of the two currents.
ADC VALUE
REGISTER
(READ-ONLY
ADDRESS 0x04)
DATA
CONFIG2
REGISTER
V
DD
(READ/WRITE
ADDRESS 0x05)
I
N × I
SDA
SCL
SERIAL BUS INTERFACE
Figure 13. AD7417/AD7418 Register Structure
V
OUT+
Address Pointer Register
TO ADC
SENSING
TRANSISTOR
The address pointer register is an 8-bit register that stores an
address that points to one of the six data registers. The first data
byte of every serial write operation to the AD7416/AD7417/
AD7418 is the address of one of the data registers, which is
stored in the address pointer register, and selects the data
register to which subsequent data bytes are written. Only the
three LSBs of the address pointer register are used to select a
data register.
V
OUT–
SENSING
TRANSISTOR
Figure 12. Temperature Measurement Technique
Figure 12 shows the method the AD7416/AD7417/AD7418 use
to measure the device temperature. To measure ΔVBE, the
sensor (substrate transistor) is switched between operating
currents of I and N × I. The resulting waveform is passed through
a chopper-stabilized amplifier that performs the functions of
amplification and rectification of the waveform to produce a dc
voltage proportional to ΔVBE. This voltage is measured by the ADC
to give a temperature output in 10-bit twos complement form.
Table 7. Address Pointer Register
P71
P61
P51
P41
P31
P2
P1
P0
0
0
0
0
0
Register select
1 P3 to P7 must be set to 0.
Rev. I | Page 12 of 24
AD7416/AD7417/AD7418
Table 8. Register Addresses
The AD7416 contains a temperature-only channel; the AD7417
has four analog input channels and a temperature channel; and
the AD7418 has two channels, a temperature channel, and an
analog input channel. The temperature channel address for all
parts is the same, Channel 0. The address for the analog input
channel on the AD7418 is Channel 4. Table 12 outlines the
channel selection on the parts, and Table 13 shows the fault
queue settings. D1 and D2 are explained in the OTI Output
section.
P2
P1
P0
Registers
0
0
0
0
0
1
0
1
0
Temperature value
Configuration register
THYST setpoint
0
1
1
TOTI setpoint
1
1
0
0
0
1
ADC value (AD7417/AD7418 only)
Config2 (AD7417/AD7418 only)
Temperature Value Register (Address 0x00)
Table 12. Channel Selection
The temperature value register is a 16-bit, read-only register
whose 10 MSBs store the temperature reading from the ADC in
10-bit twos complement format. Bit D5 to Bit D0 are unused.
D7
D6
D5
Channel Selection
0
0
0
0
0
0
1
1
0
1
0
1
Temperature sensor (all parts), Channel 0
AIN1 (AD7417 only), Channel 1
AIN2 (AD7417 only), Channel 2
AIN3 (AD7417 only), Channel 3
AIN4 (AD7417) and AIN (AD7418), Channel 4
Table 9. Temperature Value Register
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6
MSB B8
B7
B6
B5
B4
B3 B2 B1 LSB
1
0
0
The temperature data format is shown in Table 10. This shows
the full theoretical range of the ADC from −128°C to +127°C,
but in practice, the temperature measurement range is limited
to the operating temperature range of the device.
Table 13. Fault Queue Settings
D4
D3
Number of Faults
0
0
1 (power-up default)
0
1
1
1
0
1
2
4
6
Table 10. Temperature Data Format
Temperature
−128°C
−125°C
−100°C
−75°C
−50°C
−25°C
−10°C
−0.25°C
0°C
+0.25°C
+10°C
+25°C
+50°C
+75°C
+100°C
+125°C
+127°C
Digital Output
10 0000 0000
10 0000 1100
10 0111 0000
10 1101 0100
11 0011 1000
11 1001 1100
11 1101 1000
11 1111 1111
00 0000 0000
00 0000 0001
00 0010 1000
00 0110 0100
00 1100 1000
01 0010 1100
01 1001 0000
01 1111 0100
01 1111 1100
THYST Setpoint Register (Address 0x02)
The THYST setpoint register is a 16-bit, read/write register whose
nine MSBs store the THYST setpoint in twos complement format
equivalent to the nine MSBs of the temperature value register.
Bit D6 to Bit D0 are unused.
TOTI Setpoint Register (Address 0x03)
The TOTI setpoint register is a 16-bit, read/write register whose
nine MSBs store the TOTI setpoint in twos complement format
equivalent to the nine MSBs of the temperature value register.
Bit 6 to Bit 0 are unused.
Table 14. THYST Setpoint and TOTI Setpoint Registers
D15
D14
D13 D12 D11 D10 D9 D8 D7
MSB
B7
B6 B5 B4 B3 B2 B1 LSB
ADC Value Register (Address 0x04)
The ADC value register is a 16-bit, read-only register whose
10 MSBs store the value produced by the ADC in binary format.
Bit D5 to Bit D0 are unused. Table 15 shows the ADC value
register with 10 MSBs containing the ADC conversion request.
Configuration Register (Address 0x01)
The configuration register is an 8-bit, read/write register that is
used to set the operating modes of the AD7416/AD7417/AD7418.
Bit D7 to Bit D5 control the channel selection as outlined in
Table 12. Bits[D7:D5] should always be set to 000 for the AD7416.
Bit D4 and Bit D3 are used to set the length of the fault queue.
D2 sets the sense of the OTI output. D1 selects the comparator
or interrupt mode of operation, and D0 = 1 selects the shutdown
mode (default: D0 = 0).
Table 15. ADC Value Register
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6
MSB B8
B7
B6
B5
B4
B3 B2 B1 LSB
ADC Transfer Function
The designed code transitions occur at successive integer
LSB values (that is, 1 LSB, 2 LSB, and so on). The LSB size =
VREF/1024. The ideal transfer function characteristic for the
AD7417 and AD7418 ADC is shown in Figure 14.
Table 11. Configuration Register
D7 D6 D5 D4 D3 D2
D1
D0
Channel
selection
Fault
queue
OTI
polarity
Cmp/Int Shutdown
Rev. I | Page 13 of 24
AD7416/AD7417/AD7418
direction of the data transfer, that is, whether data is written
to or read from the slave device.
111...111
111...110
The peripheral whose address corresponds to the transmitted
address responds by pulling the data line low during the low
period before the ninth clock pulse, known as the acknowl-
edge bit. All other devices on the bus now remain idle while
the selected device waits for data to be read from or written
111...000
1LSB – VREF/1024
011...111
W
to it. If the R/ bit is a 0, then the master writes to the
000...010
000...001
000...000
W
slave device. If the R/ bit is a 1, then the master reads
from the slave device.
0V 1/2LSB
+VREF – 1LSB
ANALOG INPUT
2. Data is sent over the serial bus in sequences of nine clock
pulses, eight bits of data followed by an acknowledge bit
from the receiver of data. Transitions on the data line must
occur during the low period of the clock signal and remain
stable during the high period, because a low-to-high transi-
tion when the clock is high may be interpreted as a stop signal.
3. When all data bytes have been read or written, stop
conditions are established. In write mode, the master pulls
the data line high during the 10th clock pulse to assert a
stop condition. In read mode, the master device pulls the
data line high during the low period before the ninth clock
pulse. This is known as no acknowledge. The master then
takes the data line low during the low period before the
10th clock pulse, then high during the 10th clock pulse to
assert a stop condition.
Figure 14. Ideal Transfer Function Characteristic for the AD7417/AD7418
Config2 Register (Address 0x05)
A second configuration register is included in the AD7417/
AD7418 for the functionality of the
register with Bit D5 to Bit D0 being left at 0. Bit D7 determines
whether the AD7417/AD7418 should be operated in its default
mode (D7 = 0), performing conversions every 355 μs or in its
CONVST
pin. It is an 8-bit
CONVST
when the
pin mode (D7 = 1), where conversions start only
CONVST
pin is used. Bit 6 contains the Test 1 bit.
When this bit is 0, the I2C filters are enabled (default). Setting
this bit to 1 disables the filters.
Table 16. Config2 Register
D7
D6
D5 D4 D3 D2 D1 D0
Any number of bytes of data can be transferred over the serial
bus in one operation, but it is not possible to mix read and write
in one operation because the type of operation is determined at
the beginning and cannot subsequently be changed without
starting a new operation.
Conversion mode
Test 1
0
0
0
0
0
0
SERIAL BUS INTERFACE
Control of the AD7416/AD7417/AD7418 is carried out via the
I2C compatible serial bus. The AD7416/AD7417/AD7418 are
connected to this bus as a slave device, under the control of a
master device, for example, the processor.
Writing to the AD7416/AD7417/AD7418
Depending on the register being written to, there are three
different writes for the AD7416/AD7417/AD7418.
Serial Bus Address
•
Writing to the address pointer register for a subsequent read.
To read data from a particular register, the address pointer
register must contain the address of that register. If it does
not, the correct address must be written to the address pointer
register by performing a single-byte write operation, as shown
in Figure 15. The write operation consists of the serial bus
address followed by the address pointer byte. No data is
written to any of the data registers.
As with all I2C compatible devices, the AD7416/AD7417/AD7418
have a 7-bit serial address. The four MSBs of this address for the
AD7416 are set to 1001; the AD7417 are set to 0101, and the
three LSBs can be set by the user by connecting the A2 to A0
pins to either VDD or GND. By giving them different addresses,
up to eight AD7416/AD7417 devices can be connected to a
single serial bus, or the addresses can be set to avoid conflicts
with other devices on the bus. The four MSBs of this address for
the AD7418 are set to 0101, and the three LSBs are all set to 0.
•
Writing a single byte of data to the configuration register, the
Config2 register, or to the TOTI setpoint or THYST setpoint
registers.
If a serial communication occurs during a conversion operation,
the conversion stops and restarts after the communication.
The configuration register is an 8-bit register, so only one
byte of data can be written to it. If only 8-bit temperature
comparisons are required, the temperature LSB can be
ignored in TOTI and THYST, and only eight bits need to be
written to the TOTI setpoint and THYST setpoint registers.
Writing a single byte of data to one of these registers consists
of the serial bus address, the data register address written
to the address pointer register, followed by the data byte
The serial bus protocol operates as follows:
1. The master initiates data transfer by establishing a start condi-
tion, defined as a high-to-low transition on the serial data
line, SDA, while the serial clock line, SCL, remains high.
This indicates that an address/data stream follows. All slave
peripherals connected to the serial bus respond to the 7-bit
W
address (MSB first) plus an R/ bit, which determines the
Rev. I | Page 14 of 24
AD7416/AD7417/AD7418
written to the selected data register. This is illustrated in
Figure 16.
Writing two bytes of data to the TOTI setpoint or THYST
setpoint register.
THYST setpoint registers. This consists of the serial bus
address, the register address written to the address pointer
register, followed by two data bytes written to the selected
data register. This is illustrated in Figure 17.
•
If 9-bit resolution is required for the temperature setpoints,
two bytes of data must be written to the TOTI setpoint and
1
9
1
9
SCL
SDA
1
0
0
1
A2
A1
A0
R/W
P7
P6
P5
P4
P3
P2
P1
P0
START BY
MASTER
ACK. BY
AD741x
ACK. BY STOP
1
1
AD741x
BY
MASTER
FRAME 1
SERIAL BUS ADDRESS BYTE
FRAME 2
ADDRESS POINTER REGISTER BYTE
1
AD741x = AD7416/AD7417/AD7418.
Figure 15. Writing to the Address Pointer Register to Select a Data Register for a Subsequent Read Operation
1
1
9
1
9
SCL
SDA
0
0
1
A2
A1
A0
R/W
P7
P6
P5
P4
P3
P2
P1
P0
START BY
MASTER
ACK. BY
AD741x
ACK. BY
AD741x
1
1
FRAME 1
SERIAL BUS ADDRESS BYTE
FRAME 2
ADDRESS POINTER REGISTER BYTE
1
9
SCL (CONTINUED)
SDA (CONTINUED)
STOP
D7
D6
D5
D4
D3
D2
D1
D0
BY
MASTER
ACK. BY
AD741x
1
FRAME 3
DATA BYTE
1
AD741x = AD7416/AD7417/AD7418.
Figure 16. Writing to the Address Pointer Register Followed by a Single Byte of Data to the Selected Data Register
1
1
9
1
9
SCL
SDA
0
0
1
A2
A1
A0
R/W
P7
P6
P5
P4
P3
P2
P1
P0
START BY
MASTER
ACK. BY
AD741x
ACK. BY
AD741x
1
1
FRAME 1
SERIAL BUS ADDRESS BYTE
FRAME 2
ADDRESS POINTER REGISTER BYTE
1
9
1
9
SCL
(CONTINUED)
SDA
(CONTINUED)
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
STOP
BY
MASTER
ACK. BY STOP BY
1
ACK. BY
AD741x
1
AD741x
MASTER
FRAME 3
FRAME 4
MOST SIGNIFICANT DATA BYTE
LEAST SIGNIFICANT DATA BYTE
1
AD741x = AD7416/AD7417/AD7418.
Figure 17. Writing to the Address Pointer Register Followed by Two Bytes of Data to the TOTI Setpoint or THYST Setpoint Register
Rev. I | Page 15 of 24
AD7416/AD7417/AD7418
Reading Data From the AD7416/AD7417/AD7418
Note that when reading back from the AD7416/AD7417/
AD7418, no more than three bytes of data must be read back.
A stop command must be inserted at the end of the read
communication. If a stop command is not inserted by the
master and the AD7416/AD7417/AD7418 receive more SCL
cycles than the maximum needed for three bytes of data, then
the I2C interface on the AD7416/AD7417/AD7418 pulls the
SDA line low and prevents it from going high again. To recover
the AD7416/AD7417/AD7418 interface, the part must be
powered off and on again. Reference the AN-686 Application
Note, Implementing an I2C® Reset at www.analog.com for more
Reading data from the AD7416/AD7417/AD7418 is a single-
byte or 2-byte operation. Reading back the contents of the
configuration register is a single-byte read operation, as shown
in Figure 18, with the register address previously having been
set by a single-byte write operation to the address pointer
register.
Reading data from the temperature value register, the TOTI
setpoint or THYST setpoint register is a 2-byte operation, as
shown in Figure 19. It is also possible to read the most
significant bit of a 9-bit or 10-bit register in this manner.
information on I2C interfaces.
1
9
1
9
SCL
SDA
1
0
0
1
A2
A1
A0
R/W
D7
D6
D5
D4
D3
D2
D1
D0
START BY
MASTER
ACK. BY
AD741x
NO ACK. BY STOP
1
BY
MASTER
MASTER
FRAME 1
SERIAL BUS ADDRESS BYTE
FRAME 2
SINGLE DATA BYTE FROM AD741x
1
1
AD741x = AD7416/AD7417/AD7418.
Figure 18. Reading a Single Byte of Data from the Configuration Register
1
9
1
9
SCL
SDA
1
0
0
1
A2
A1
A0
R/W
D15
D14
D13
D12
D11
D10
D9
D8
START BY
MASTER
ACK. BY
AD741x
ACK. BY
MASTER
1
FRAME 1
SERIAL BUS ADDRESS BYTE
FRAME 2
1
MOST SIGNIFICANT BYTE FROMAD741x
1
9
SCL (CONTINUED)
SDA (CONTINUED)
STOP
BY
MASTER
D7
D6
D5
D4
D3
D2
D1
D0
NO ACK. BY
MASTER
FRAME 3
1
LEAST SIGNIFICANT DATA BYTE FROM AD741x
1
AD741x = AD7416/AD7417/AD7418.
Figure 19. Reading Two Bytes of Data from the TOTI Setpoint or THYST Setpoint Register
Rev. I | Page 16 of 24
AD7416/AD7417/AD7418
OTI OUTPUT
FAULT QUEUE
The OTI output has two operating modes that are selected by
Bit D1 of the configuration register. In the comparator mode,
(D1 = 0), the OTI output becomes active when the temperature
exceeds TOTI and remains active until the temperature falls
below THYST. This mode allows the AD7416/AD7417/AD7418 to
be used as a thermostat, for example, to control the operation of
a cooling fan.
To avoid false triggering of the AD7416/AD7417/AD7418 in
noisy environments, a fault queue counter is provided that can
be programmed by Bit D3 and Bit D4 of the configuration
register (see Table 11) to count 1, 2, 4, or 6 fault events before
OTI becomes active. To trigger OTI, the faults must occur
consecutively. For example, if the fault queue is set to 4, then
four consecutive temperature measurements greater than TOTI
(or less than THYST) must occur. Any reading that breaks the
sequence resets the fault queue counter, so if there are three
T
OTI
readings greater than TOTI followed by a reading less than TOTI
,
the fault queue counter is reset without triggering OTI.
T
HYST
OTI OUTPUT
COMPARATOR
MODE
POWER-ON DEFAULTS
The AD7416/AD7417/AD7418 always power up with the
following defaults:
OTI OUTPUT
INTERRUPT
MODE
1
1
1
1
1
1
1
READ READ READ READ READ READ READ
•
Address pointer pointing to temperature value register
comparator mode
1
IN INTERRUPT MODE, A READ OPERATION OR SHUTDOWN RESETS THE OTI
OUTPUT; OTHERWISE, THE OTI OUTPUT REMAINSACTIVE INDEFINITELY,
ONCE TRIGGERED.
•
•
•
•
T
OTI = 80°C
Figure 20. Operation of OTI Output (Shown Active Low)
THYST = 75°C
The open-drain configuration of OTI allows the OTI outputs of
several AD7416/AD7417/AD7418 devices to be wire-AND’ed
together when in active low mode.
OTI active low
Fault queue = 1
These default settings allow the AD7416/AD7417/AD7418 to
be used as a standalone thermostat without any connection to a
serial bus.
The OTI output is used to indicate that an out-of-limit tempera-
ture excursion has occurred. OTI is an open-drain output that
can be programmed to be active low by setting Bit D2 of the
configuration register to 0 or active high by setting Bit D2 of
the configuration register to 1.
OPERATING MODES
The AD7416/AD7417/AD7418 have two possible modes of
operation depending on the value of D0 in the configuration
register.
In the interrupt mode (D1 = 1), the OTI output becomes active
when the temperature exceeds TOTI and remains active even if
the temperature falls below THYST, until it is reset by a read opera-
tion. Once OTI becomes active by the temperature exceeding
Mode 1
Normal operation of the AD7416/AD7417/AD7418 occurs
when D0 = 0. In this active mode, a conversion takes place
every 400 μs. After the conversion has taken place, the part
partially powers down, consuming typically 350 μA of the
current until the next conversion occurs.
T
OTI, and resets, it remains inactive even if the temperature
remains, or subsequently rises again, above TOTI. It does not
become active again until the temperature falls below THYST. It
then remains active until reset by a read operation. Once OTI
becomes active by the temperature falling below THYST and then
resets, it remains inactive even if the temperature remains, or
Two situations can arise in this mode on the request of a tempera-
ture read. If a read occurs during a conversion, the conversion
aborts and a new one starts on the stop/repeat start condition.
The temperature value that is read is that of the previous com-
pleted conversion. The next conversion typically occurs 400 μs
after the new conversion has begun.
subsequently falls again, below THYST
.
OTI is also reset when the AD7416/AD7417/AD7418 are placed
in shutdown mode by setting Bit D0 of the configuration
register to 1.
The OTI output requires an external pull-up resistor. This can
be connected to a voltage different from VDD (for example, to
allow interfacing between 5 V and 3.3 V systems) provided that
the maximum voltage rating of the OTI output is not exceeded.
If a read is called between conversions, a conversion is initiated
on the stop/repeat start condition. After this conversion, the
part returns to performing a conversion every 400 μs.
With VDD = 3 V for each 400 μs cycle, the AD7416/AD7417/
AD7418 spend 40 μs (or 10% of the time) in conversion mode.
The part spends 360 μs (or 90% of time) in partial power-down
mode. Thus, the average power dissipated by the AD7416/
AD7417/AD7418 is
The value of the pull-up resistor depends on the application but
should be as large as possible to avoid excessive sink currents at
the OTI output, which can heat the chip and affect the temperature
reading. The maximum value of the pull-up resistor that meets
the output high current specification of the OTI output is 30 kΩ,
but higher values can be used if a lower output current is
required. For most applications, a value of 10 kΩ is suitable.
3 mW × 0.1 + 1 mW × 0.9 = 1.2 mW
Rev. I | Page 17 of 24
AD7416/AD7417/AD7418
Mode 2
CONVST
Pin Mode
For applications where temperature measurements are required
at a slower rate, for example, every second, power consumption
of the part can be reduced by writing to the part to go to a full
power-down between reads. The current consumption in full
power-down is typically 0.2 μA and full power-down is initiated
when D0 = 1 in the configuration register. When a measurement is
required, a write operation can be performed to power up the
part. The part then performs a conversion and is returned to
power-down. The temperature value can be read in full power-
down because the I2C bus is continuously active.
CONVST
is normally low.
Conversions are initiated only by using the
pin. In
CONVST
this method of operation,
CONVST
The rising edge of
starts the power-up time. This
CONVST
power-up time is 4 μs. If the
high time is longer than
CONVST
4 μs, a conversion is initiated on the falling edge of
and the track-and-hold also enters its hold mode at this time.
CONVST
If the
initiated by the rising edge of
and-hold and the initiation of conversion until the timer times
high time is less than 4 μs, an internal timer,
CONVST
, holds off the track-
CONVST
out (4 μs after the rising edge of
CONVST
, which corresponds
input remains low at
The power dissipation in this mode depends on the rate at which
reads take place. Taking the requirements for a temperature
measurement every 100 ms as an example, the optimum power
dissipation is achieved by placing the part in full power-down,
waking it up every 100 ms, letting it operate for 400 μs and
putting it into full power-down again. In this case, the average
power consumption is calculated as follows. The part spends
40 μs (or 0.04% of time) converting with 3 mW dissipation
and a 99.96 ms (99.96% of time) in full shutdown with 60 nW
dissipation.
with the power-up time). The
the end of conversion, thus causing the part to enter its power-
CONVST
down mode. In this method of operation,
is normally
low with a high going pulse controlling the power-up, and the
conversion starts.
CONVST
The
pin should not be pulsed when reading from or
writing to the port.
Figure 21 shows the recommended minimum times for the
pulse when the temperature channel is selected.
Figure 22 shows the minimum times an analog input channel is
CONVST
Thus, the average power dissipation is
3 mW × 0.004 + 60 nW × 0.9996 = 1.2 μW
selected.
100ns
The fastest throughput rate at which the AD7416/AD7417/
AD7418 can be operated is 2.5 kHz (that is, a read every 400 μs
conversion period). Because TOTI and THYST are 2-byte reads, the
read time with the I2C operating at 100 kbps would be 270 μs. If
temperature reads are called too often, reads will overlap with
conversions, aborting them continuously, which results in
invalid readings.
CONVST
40µs
CONVST
Figure 21.
When Temperature Channel Selected
100ns
CONVST START MODE
The AD7417/AD7418 have an extra mode, set by writing to the
MSB of the Config2 register.
CONVST
15µs
CONVST
Figure 22.
When VIN Channel Selected
Rev. I | Page 18 of 24
AD7416/AD7417/AD7418
APPLICATIONS INFORMATION
SUPPLY DECOUPLING
FAN CONTROLLER
The AD7416/AD7417/AD7418 should be decoupled with a
0.1 μF ceramic capacitor between VDD and GND. This is
particularly important if the part is mounted remote from the
power supply.
Figure 23 shows a simple fan controller that switches on a
cooling fan when the temperature exceeds 80°C and switches it
off again when the temperature falls below 75°C. The AD7416
can be used as a standalone device in this application or with a
serial bus interface if different trip temperatures are required. If the
AD7416 is used with a bus interface, the sense of OTI can be set
to active high, Q1 and R1 can be omitted, and OTI can be con-
nected directly to the gate of Q2, with R2 as the pull-up resistor.
12V
POWER-ON RESET
To ensure proper power-on reset, make sure that the supply
voltage on the VDD pin is at 0 V. Refer to the AN-588 Application
Note, AD7416/AD7417/AD7418 Power-On Reset Circuit at
www.analog.com for more information. A failed power-on reset
can prevent the default values from being loaded into the AD7416/
AD7417/AD7418 registers. If the correct values are not loaded
into the registers, then the device cannot start operating. The
output from the temperature value and ADC value registers will
be a constant value.
V
DD
3V TO 5.5V
Q2
R1
R2
LOGIC LEVEL
MOSFET RATED
TO SUIT FAN
CURRENT
10kΩ
10kΩ
8
To restart the device operation, the registers have to be loaded
with their default values via the I2C bus. Therefore, in the event
of an inadequate power-on reset and for all three devices, the
following registers should be loaded with their default values:
Q1
3
AD7416
2N3904
OR SIMILAR
4
•
•
•
•
Configuration register—default value = 0x00
Config2 register—default value = 0x00
Figure 23. AD7416 Used as a Fan Controller
THYST setpoint register—default value = 0x4B00
OTI setpoint register—default value = 0x5500
THERMOSTAT
T
Figure 24 shows the AD7416 used as a thermostat. The heater
switches on when the temperature falls below THYST and
switches off again when the temperature rises above TOTI. For
this application and for comparator mode, program the OTI
output active low.
MOUNTING THE AD7416/AD7417/AD7418
The AD7416/AD7417/AD7418 can be used for surface or air
temperature sensing applications. If the device is cemented to a
surface with thermally conductive adhesive, the die temperature
is within about 0.2°C of the surface temperature, due to the low
power consumption of the device. Take care to insulate the back
and leads of the device from the air if the ambient air
temperature is different from the surface temperature being
measured.
V
DD
3V TO 5.5V
HEATER
R1
10kΩ
D1
RELAY
Q1
8
1N4001
RLA1
The GND pin provides the best thermal path to the die, so the
temperature of the die is close to that of the printed circuit
ground track. Take care to ensure that this is in close thermal
contact with the surface being measured.
HEATER
SUPLY
3
AD7416
2N3904
OR SIMILAR
4
As with any IC, the AD7416/AD7417/AD7418 and its associated
wiring and circuits must be kept free from moisture to prevent
leakage and corrosion, particularly in cold conditions where
condensation is more likely to occur. Water resistant varnishes
and conformal coatings can be used for protection. The small
size of the AD7416 package allows it to be mounted inside sealed
metal probes that provide a safe environment for the device.
Figure 24. AD7416 Used as a Thermostat
Rev. I | Page 19 of 24
AD7416/AD7417/AD7418
line. This arrangement means that each device must be read to
determine which one has generated the interrupt, and if a
unique interrupt is required for each device, the OTI outputs
can be connected separately to the I/O chip.
SYSTEM WITH MULTIPLE AD7416 DEVICES
The three LSBs of the AD7416 serial address can be set by the
user, allowing eight different addresses from 1001000 to
1001111. Figure 25 shows a system in which eight AD7416
devices are connected to a single serial bus, with their OTI
outputs wire-AND’ed together to form a common interrupt
V
DD
3V TO
5.5V
R1
10kΩ
8
8
7
6
5
4
8
7
6
5
4
8
7
6
5
4
8
7
6
5
4
8
7
6
5
4
8
7
6
5
4
8
7
6
5
4
7
6
5
4
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
Figure 25. Multiple Connection of AD7416 Devices to a Single Serial Bus
Rev. I | Page 20 of 24
AD7416/AD7417/AD7418
OUTLINE DIMENSIONS
10.00 (0.3937)
9.80 (0.3858)
9
8
16
1
6.20 (0.2441)
5.80 (0.2283)
4.00 (0.1575)
3.80 (0.1496)
1.27 (0.0500)
BSC
0.50 (0.0197)
0.25 (0.0098)
45°
1.75 (0.0689)
1.35 (0.0531)
0.25 (0.0098)
0.10 (0.0039)
8°
0°
COPLANARITY
0.10
SEATING
PLANE
1.27 (0.0500)
0.40 (0.0157)
0.51 (0.0201)
0.31 (0.0122)
0.25 (0.0098)
0.17 (0.0067)
COMPLIANT TO JEDEC STANDARDS MS-012-AC
CONTROLLING DIMENSIONS ARE IN MILLIMETERS; INCH DIMENSIONS
(IN PARENTHESES) ARE ROUNDED-OFF MILLIMETER EQUIVALENTS FOR
REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN.
Figure 26. 16-Lead Standard Small Outline Package [SOIC_N]
Narrow Body
(R-16)
Dimensions shown in millimeters and (inches)
5.00 (0.1968)
4.80 (0.1890)
8
1
5
4
6.20 (0.2441)
5.80 (0.2284)
4.00 (0.1574)
3.80 (0.1497)
0.50 (0.0196)
0.25 (0.0099)
1.27 (0.0500)
BSC
45°
1.75 (0.0688)
1.35 (0.0532)
0.25 (0.0098)
0.10 (0.0040)
8°
0°
0.51 (0.0201)
0.31 (0.0122)
COPLANARITY
0.10
1.27 (0.0500)
0.40 (0.0157)
0.25 (0.0098)
0.17 (0.0067)
SEATING
PLANE
COMPLIANT TO JEDEC STANDARDS MS-012-AA
CONTROLLING DIMENSIONS ARE IN MILLIMETERS; INCH DIMENSIONS
(IN PARENTHESES) ARE ROUNDED-OFF MILLIMETER EQUIVALENTS FOR
REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN.
Figure 27. 8-Lead Standard Small Outline Package [SOIC_N]
Narrow Body
(R-8)
Dimensions shown in millimeters and (inches)
Rev. I | Page 21 of 24
AD7416/AD7417/AD7418
5.10
5.00
4.90
16
9
8
4.50
4.40
4.30
6.40
BSC
1
PIN 1
1.20
MAX
0.15
0.05
0.20
0.09
0.75
0.60
0.45
8°
0°
0.30
0.19
0.65
BSC
SEATING
PLANE
COPLANARITY
0.10
COMPLIANT TO JEDEC STANDARDS MO-153-AB
Figure 28. 16-Lead Thin Shrink Small Outline Package [TSSOP]
(RU-16)
Dimensions shown in millimeters
3.20
3.00
2.80
8
1
5
4
5.15
4.90
4.65
3.20
3.00
2.80
PIN 1
0.65 BSC
0.95
0.85
0.75
1.10 MAX
0.80
0.60
0.40
8°
0°
0.15
0.00
0.38
0.22
0.23
0.08
SEATING
PLANE
COPLANARITY
0.10
COMPLIANT TO JEDEC STANDARDS MO-187-AA
Figure 29. 8-Lead Mini Small Outline Package [MSOP]
(RM-8)
Dimensions shown in millimeters
Rev. I | Page 22 of 24
AD7416/AD7417/AD7418
ORDERING GUIDE
Temperature
Range
Temperature
Error
Package
Branding Option
Model1
Package Description
AD7416AR
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
2°C
2°C
2°C
2°C
2°C
2°C
2°C
2°C
2°C
2°C
2°C
2°C
8-Lead Standard Small Outline Package (SOIC_N)
8-Lead Standard Small Outline Package (SOIC_N)
8-Lead Standard Small Outline Package (SOIC_N)
8-Lead Standard Small Outline Package (SOIC_N)
8-Lead Standard Small Outline Package (SOIC_N)
8-Lead Standard Small Outline Package (SOIC_N)
8-Lead Mini Small Outline Package (MSOP)
8-Lead Mini Small Outline Package (MSOP)
8-Lead Mini Small Outline Package (MSOP)
8-Lead Mini Small Outline Package (MSOP)
8-Lead Mini Small Outline Package (MSOP)
8-Lead Mini Small Outline Package (MSOP)
Bare Die Wafer
R-8
R-8
R-8
R-8
R-8
R-8
RM-8
RM-8
RM-8
RM-8
RM-8
RM-8
AD7416AR-REEL
AD7416AR-REEL7
AD7416ARZ
AD7416ARZ-REEL
AD7416ARZ-REEL7
AD7416ARM
AD7416ARM-REEL
AD7416ARM-REEL7
AD7416ARMZ
AD7416ARMZ-REEL
AD7416ARMZ-REEL7
AD7417-WAFER
AD7417AR
C6A
C6A
C6A
C6A#
C6A#
C6A#
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +85°C
−40°C to +85°C
−40°C to +85°C
−40°C to +85°C
−40°C to +85°C
−40°C to +85°C
2°C
2°C
2°C
2°C
2°C
2°C
2°C
2°C
2°C
2°C
2°C
2°C
1°C
1°C
1°C
1°C
1°C
1°C
16-Lead Standard Small Outline Package (SOIC_N)
16-Lead Standard Small Outline Package (SOIC_N)
16-Lead Standard Small Outline Package (SOIC_N)
16-Lead Standard Small Outline Package (SOIC_N)
16-Lead Standard Small Outline Package (SOIC_N)
16-Lead Standard Small Outline Package (SOIC_N)
16-Lead Thin Shrink Small Outline Package (TSSOP)
16-Lead Thin Shrink Small Outline Package (TSSOP)
16-Lead Thin Shrink Small Outline Package (TSSOP)
16-Lead Thin Shrink Small Outline Package (TSSOP)
16-Lead Thin Shrink Small Outline Package (TSSOP)
16-Lead Thin Shrink Small Outline Package (TSSOP)
16-Lead Standard Small Outline Package (SOIC_N)
16-Lead Standard Small Outline Package (SOIC_N)
16-Lead Standard Small Outline Package (SOIC_N)
16-Lead Standard Small Outline Package (SOIC_N)
16-Lead Standard Small Outline Package (SOIC_N)
16-Lead Standard Small Outline Package (SOIC_N)
Die
8-Lead Standard Small Outline Package (SOIC_N)
8-Lead Standard Small Outline Package (SOIC_N)
8-Lead Standard Small Outline Package (SOIC_N)
8-Lead Mini Small Outline Package (MSOP)
8-Lead Mini Small Outline Package (MSOP)
8-Lead Mini Small Outline Package (MSOP)
8-Lead Mini Small Outline Package (MSOP)
8-Lead Mini Small Outline Package (MSOP)
8-Lead Mini Small Outline Package (MSOP)
Evaluation Board
R-16
AD7417AR-REEL
AD7417AR-REEL7
AD7417ARZ
AD7417ARZ-REEL
AD7417ARZ-REEL7
AD7417ARU
AD7417ARU-REEL
AD7417ARU-REEL7
AD7417ARUZ
AD7417ARUZ-REEL
AD7417ARUZ-REEL7
AD7417BR
AD7417BR-REEL
AD7417BR-REEL7
AD7417BRZ
AD7417BRZ-REEL
AD7417BRZ-REEL7
AD7418ACHIPS
AD7418ARZ
AD7418ARZ-REEL
AD7418ARZ-REEL7
AD7418ARM
AD7418ARM-REEL
AD7418ARM-REEL7
AD7418ARMZ
R-16
R-16
R-16
R-16
R-16
RU-16
RU-16
RU-16
RU-16
RU-16
RU-16
R-16
R-16
R-16
R-16
R-16
R-16
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
2°C
2°C
2°C
2°C
2°C
2°C
2°C
2°C
2°C
R-8
R-8
R-8
RM-8
RM-8
RM-8
RM-8
RM-8
RM-8
C7A
C7A
C7A
T0G
T0G
T0G
AD7418ARMZ-REEL
AD7418ARMZ-REEL7
EVAL-AD7416/7/8EBZ
1 Z = RoHS Compliant Part.
Rev. I | Page 23 of 24
AD7416/AD7417/AD7418
NOTES
I2C refers to a communications protocol originally developed by Philips Semiconductors (Now NXP Semiconductors).
©1998–2010 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D01126-0-11/10(I)
Rev. I | Page 24 of 24
相关型号:
©2020 ICPDF网 联系我们和版权申明