AD7799 [ADI]

Low Power, 24-Bit/16-Bit Sigma-Delta ADC with In-Amp; 低功耗,24位/ 16位Σ- Δ型ADC仪表放大器
AD7799
型号: AD7799
厂家: ADI    ADI
描述:

Low Power, 24-Bit/16-Bit Sigma-Delta ADC with In-Amp
低功耗,24位/ 16位Σ- Δ型ADC仪表放大器

仪表放大器
文件: 总17页 (文件大小:672K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Low Power, 24-Bit/16-Bit  
Sigma-Delta ADC with In-Amp  
Preliminary Technical Data  
AD7798/AD7799  
FUNCTIONAL BLOCK DIAGRAM  
FEATURES  
Resolution:  
AD7798: 16-Bit  
AD7799: 24-Bit  
REFERENCE  
DETECT  
AD7799/AD7798  
AV  
DD  
Three Differential Analog Inputs  
Low Noise Programmable Gain Amp  
RMS noise: 80 nV (Gain = 64) at 16.6 Hz update rate (AD7798)  
65 nV (Gain = 64) at 16.6 Hz update rate (AD7799)  
30 nV (Gain = 64) at 4 Hz update rate (AD7799)  
Update Rate: 4 Hz to 500 Hz  
Power  
AIN1(+)  
SERIAL  
INTERFACE  
AND  
CONTROL  
LOGIC  
AIN1(-)  
DOUT/RDY  
DIN  
AIN2(+)  
AIN2(-)  
SIGMA DELTA  
ADC  
IN-AMP  
MUX  
SCLK  
CS  
AIN3(+)/P1  
AIN3(-)/P2  
GND  
PWRSW  
INTERNAL  
CLOCK  
DV  
DD  
Supply: 2.7 V to 5.25 V operation  
Normal: 330 µA typ (AD7798)  
400 µA typ (AD7799)  
GND  
Figure 1.  
Power-down: 1 µA max  
GENERAL DESCRIPTION  
Simultaneous 50 Hz/60 Hz Rejection  
Two Programmable Digital Outputs  
Internal Clock Oscillator  
Reference Detect  
100 nA Burnout Currents  
Low Side Power Switch  
Independent Interface Power Supply  
16-Lead TSSOP  
The AD7798/AD7799 is a low power, complete analog front end  
for low frequency measurement applications. The device  
contains a low noise 24-bit (AD7799)/ 16-bit (AD7798) ∑-∆  
ADC with three differential inputs. The on-chip low noise  
instrumentation amplifier means that signals of small  
amplitude can be interfaced directly to the ADC. With a gain  
setting of 64, the rms noise is 80 nV for AD7798 and 65 nV for  
the AD7799 at 16.6 Hz.  
The device contains a low side power switch which is useful in  
bridge applications. The switch allows the bridge to be  
disconnected from the power supply when conversions are not  
being performed and this will minimise power consumption.  
The device also has 100 nA burnout currents. These currents  
are used to detect if sensors connected to the analog inputs are  
burnt out. Other on-chip features include an internal clock so  
the user does not have to supply a clock to the device. This  
reduces the component count in a system and provides board  
space savings. The update rate is programmable on the  
AD7798/99. It can be varied from 4 Hz to 500 Hz.  
INTERFACE  
3-wire serial  
SPI®, QSPI™, MICROWIRE™, and DSP compatible  
Schmitt trigger on SCLK  
APPLICATIONS  
Pressure measurement  
Weigh scales  
The part operates with a single power supply from 2.7 V to 5.25  
V. It consumes a current of 380 uA maximum for the AD7798  
and 450 uA maximum for the AD7799. The AD7799/AD7798 is  
housed in a 16-lead TSSOP package.  
Rev. PrD.  
Information furnished by Analog Devices is believed to be accurate and reliable.  
However, no responsibility is assumed by Analog Devices for its use, nor for any  
infringements of patents or other rights of third parties that may result from its use.  
Specifications subject to change without notice. No license is granted by implication  
or otherwise under any patent or patent rights of Analog Devices. Trademarks and  
registered trademarks are the property of their respective companies.  
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.  
Tel: 781.329.4700  
Fax: 781.326.8703  
www.analog.com  
© 2004 Analog Devices, Inc. All rights reserved.  
AD7798/AD7799  
Preliminary Technical Data  
TABLE OF CONTENTS  
AD7799/AD7798—Specifications.................................................. 3  
Timing Characteristics, .................................................................... 6  
Absolute Maximum Ratings............................................................ 8  
Pin Configuration and Function Descriptions............................. 9  
Typical Performance Characteristics ........................................... 11  
On-chip Registers ........................................................................... 12  
Communications Register (RS2, RS1, RS0 = 0, 0, 0).............. 12  
Configuration Register (rs2, RS1, RS0 = 0, 1, 0; Power-  
on/Reset = 0x0710) .................................................................... 15  
Data Register (RS2, RS1, RS0 = 0, 1, 1; Power-on/Reset =  
0x0000 (AD7798)/ 0x000000 (AD7799))................................ 16  
ID Register (RS2, RS1, RS0 = 1, 0, 0; Power-on/Reset = 0xX8  
(AD7798)/ 0xX9 (AD7799))..................................................... 16  
OFFSET Register (RS2, RS1, RS0 = 1, 1, 0; Power-on/Reset =  
0x8000 (AD7798)/0x800000 (AD7799))................................. 17  
FULLSCALE Register (RS2, RS1, RS0 = 1, 1, 1; Power-  
Status Register (RS2, RS1, RS0 = 0, 0, 0; Power-on/Reset =  
0x88)............................................................................................. 13  
on/Reset = 0x5XXX (AD7798)/0x5XXX000 (AD7799)) ..... 17  
TYPICAL APPLICATION........................................................ 17  
Mode Register (RS2, RS1, RS0 = 0, 0, 1; Power-on/Reset =  
0x000A)........................................................................................ 13  
REVISION HISTORY  
Prelim D, June 2004: Initial Version  
REV. PrD. Page 2 of 17  
Preliminary Technical Data  
AD7798/AD7799  
AD7799/AD7798—SPECIFICATIONS1  
Table 1. (AVDD = 2.7 V to 5.25 V; DVDD = 2.7 V to 5.25 V; GND = 0 V; REFIN(+) = 2.5 V; REFIN(-) = 0 V; all specifications TMIN to  
TMAX, unless otherwise noted.)  
Parameter  
AD7798/AD7799B  
Unit  
Test Conditions/Comments  
ADC CHANNEL SPECIFICATION  
Output Update Rate  
4
500  
Hz min nom  
Hz max nom  
ADC CHANNEL  
No Missing Codes2  
24  
16  
Bits min  
Bits min  
Bits p-p  
Bits p-p  
Bits p-p  
Bits p-p  
AD7799, fADC 125 Hz  
AD7798  
Gain = 128, 16.6 Hz Update Rate  
Gain = 1, 16.6 Hz Update Rate, AD7799  
Gain = 1, 16.6 Hz Update Rate, AD7798  
Gain = 64, 4 Hz Update Rate, AD7799  
Resolution  
16  
19  
16  
18.5  
Output Noise and Update Rates  
Integral Nonlinearity  
See Tables in ADC  
Description  
15  
25  
3
ppm of FSR max  
ppm of FSR max  
µV typ  
3.5 ppm typ, Gain 1 to 32  
Gain = 64 or 128  
Offset Error3  
Offset Error Drift vs. Temperature4  
Full-Scale Error5  
10  
10  
0.5  
3
nV/°C typ  
µV typ  
ppm/°C typ  
ppm/°C typ  
dB min  
Gain Drift vs. Temperature4  
Gain = 1, 2  
Gain = 4 to 128  
100 dB typ, AIN = 50 % of full scale  
Power Supply Rejection  
ANALOG INPUTS  
90  
Differential Input Voltage Ranges  
Absolute AIN Voltage Limits2  
Unbuffered Mode  
REFIN/Gain  
V nom  
REFIN = REFIN(+) – REFIN(–), Gain = 1 to 128  
Gain = 1 or 2  
GND + 30 mV  
AVDD – 30 mV  
GND + 100 mV  
AVDD – 100 mV  
GND + 300 mV  
V max  
V min  
V min  
V max  
V min  
V max  
Buffered Mode  
In-Amp Enabled  
Gain = 1 or 2  
Gain = 4 to 128  
V
DD – 1.2  
Common Mode Voltage  
In-Amp Enabled  
0.5  
V min  
Gain = 4 to 128  
Analog Input Current  
Buffered Mode or In-Amp Enabled  
2
Average Input Current  
200  
1
2
pA max  
nA max  
pA/°C typ  
AIN1(+) – AIN1(-), AIN2(+) – AIN2(-) only.  
AIN3(+) – AIN3(-).  
Average Input Current Drift  
Unbuffered Mode  
Average Input Current  
Average Input Current Drift  
Normal Mode Rejection2  
@ 50 Hz, 60 Hz  
Gain = 1 or 2  
Input current varies with input voltage.  
400  
50  
nA/V typ  
pA/V/°C typ  
70  
84  
90  
dB min  
dB min  
dB min  
73 dB typ, 50 1 Hz, 60 1 Hz, FS[3:0] = 10106  
90 dB typ, 50 1 Hz, FS[3:0] = 10016  
90 dB typ, 60 1 Hz, FS[3:0] = 10006  
AIN = 50% of FS  
@ 50 Hz  
@ 60 Hz  
Common Mode Rejection  
@DC  
90  
100  
dB min  
dB min  
80 dB typ, FS[3:0] = 10106  
@ 50 Hz, 60 Hz  
50 1 Hz (FS[3:0] = 10016), 60 1 Hz (FS[3:0] =  
2
10006)  
REV. PrD. Page 3 of 17  
 
 
 
AD7798/AD7799  
Preliminary Technical Data  
Parameter  
AD7798/AD7799B  
Unit  
Test Conditions/Comments  
REFERENCE INPUT  
REFIN Voltage  
2.5  
V nom  
REFIN = REFIN(+) – REFIN(–)  
2
Reference Voltage Range  
0.1  
V min  
AV DD  
V max  
2
Absolute REFIN Voltage Limits  
GND – 30 mV  
V min  
AVDD + 30 mV  
V max  
Average reference Input Current  
Average Reference Input Current Drift  
400  
0.03  
nA/V typ  
nA/V/°C typ  
2
Normal Mode Rejection  
See ANALOG INPUTS  
Common Mode Rejection  
Reference Detect  
See ANALOG INPUTS  
0.3  
0.65  
V min  
V max  
NOREF bit Inactive if VREF < 0.3 V  
NOREF bit Active if VREF > 0.65 V  
LOW SIDE POWER SWITCH  
RON  
5
7
20  
Ω max  
Ω max  
mA max  
AVDD = 5V  
AVDD = 3V  
Continuous Current  
Allowable Current  
INTERNAL CLOCK  
Drift  
64 2%  
0.01  
KHz nom  
%/°C typ  
LOGIC INPUTS  
All Inputs Except SCLK and DIN  
VINL, Input Low Voltage  
0.8  
0.4  
2.0  
V max  
V max  
V min  
DVDD = 5 V  
DVDD = 3 V  
DVDD = 3 V or 5 V  
VINH, Input High Voltage  
SCLK and DIN Only (Schmitt-  
2
Triggered Input)  
VT(+)  
VT(–)  
VT(+) – VT(–)  
VT(+)  
VT(–)  
VT(+) - VT(–)  
Input Currents  
Input Capacitance  
1.4/2  
0.8/1.4  
0.3/0.85  
0.9/2  
0.4/1.1  
0.3/0.85  
1
V min/V max  
V min/V max  
V min/V max  
V min/V max  
V min/V max  
V min/V max  
µA max  
DVDD = 5 V  
DVDD = 5 V  
DVDD = 5 V  
DVDD = 3 V  
DVDD = 3 V  
DVDD = 3 V  
V
IN = DVDD or GND  
10  
pF typ  
All Digital Inputs  
LOGIC OUTPUTS  
2
V
OH, Output High Voltage  
DVDD – 0.6  
0.4  
4
V min  
V max  
V min  
V max  
DVDD = 3 V, ISOURCE = 100 µA  
DVDD = 3 V, ISINK = 100 µA  
DVDD = 5 V, ISOURCE = 200 µA  
DVDD = 5 V, ISINK = 1.6 mA  
2
VOL, Output Low Voltage  
VOH, Output High Voltage  
VOL, Output Low Voltage  
2
2
0.4  
Floating-State Leakage Current  
Floating-State Output Capacitance  
Data Output Coding  
1
10  
µA max  
pF typ  
Offset Binary  
DIGITAL OUTPUTS  
P1 and P2  
V
OH, Output High Voltage2  
AVDD – 0.6  
0.4  
4
V min  
V max  
V min  
V max  
AVDD = 3 V, ISOURCE = 100 µA  
AVDD = 3 V, ISINK = 100 µA  
AVDD = 5 V, ISOURCE = 200 µA  
AVDD = 5 V, ISINK = 800 µA  
2
VOL, Output Low Voltage  
V
VOL, Output Low Voltage  
OH, Output High Voltage2  
2
0.4  
REV. PrD. Page 4 of 17  
Preliminary Technical Data  
AD7798/AD7799  
Parameter  
AD7798/AD7799B  
Unit  
Test Conditions/Comments  
SYSTEM CALIBRATION2  
Full-Scale Calibration Limit  
Zero-Scale Calibration Limit  
Input Span  
1.05 x FS  
-1.05 x FS  
0.8 x FS  
V max  
V min  
V min  
V max  
2.1 x FS  
POWER REQUIREMENTS7  
Power Supply Voltage  
VDD – GND  
2.7/5.25  
2.7/5.25  
V min/max  
V min/max  
IOVDD – GND  
Power Supply Currents  
IDD Current  
150  
175  
380  
450  
1
µA max  
µA max  
µA max  
µA max  
µA max  
125 µA typ, Unbuffered Mode  
150 µA typ, Buffered Mode, In-Amp Bypassed  
330 µA typ, In-Amp used (AD7798)  
400 µA typ, IN-AMP used (AD7799)  
IDD (Power-Down Mode)  
1 Temperature Range –40°C to +105°C.  
2 Specification is not production tested but is supported by characterization data at initial product release.  
3 A System calibration will reduce this error to the order of the noise for the programmed gain and update rate.  
4 A calibration at any temperature will remove this error.  
5 Full-scale error applies to both positive and negative full-scale and applies at the factory calibration conditions (AVDD = 4 V).  
6 FS[3:0] are the four bits used in the mode register to select the output word rate.  
7 Digital inputs equal to DVDD or GND.  
REV. PrD. Page 5 of 17  
AD7798/AD7799  
Preliminary Technical Data  
TIMING CHARACTERISTICS8, 9  
Table 2. (AVDD = 2.7 V to 5.25 V; DVDD = 2.7 V to 5.25; GND = 0 V, Input Logic 0 = 0 V, Input Logic 1 = DVDD, unless otherwise  
noted.)  
Limit at TMIN, TMAX  
(B Version)  
Parameter  
Unit  
Conditions/Comments  
SCLK High Pulsewidth  
SCLK Low Pulsewidth  
t3  
t4  
100  
100  
ns min  
ns min  
Read Operation  
t1  
0
ns min  
ns max  
ns max  
ns min  
ns max  
ns max  
ns min  
ns max  
ns max  
ns min  
CS Falling Edge to DOUT/RDY Active Time  
DVDD = 4.75 V to 5.25 V  
DVDD = 2.7 V to 3.6 V  
SCLK Active Edge to Data Valid Delay11  
DVDD = 4.75 V to 5.25 V  
DVDD = 2.7 V to 3.6 V  
Bus Relinquish Time after CS Inactive Edge  
60  
80  
0
60  
80  
10  
80  
100  
10  
10  
t2  
12, 13  
t5  
t6  
SCLK Inactive Edge to CS Inactive Edge  
SCLK Inactive Edge to DOUT/RDY High  
t7  
Write Operation  
1
1
t8  
0
ns min  
ns min  
ns min  
ns min  
CS Falling Edge to SCLK Active Edge Setup Time  
t9  
t10  
t11  
30  
25  
0
Data Valid to SCLK Edge Setup Time  
Data Valid to SCLK Edge Hold Time  
CS Rising Edge to SCLK Edge Hold Time  
8 Sample tested during initial release to ensure compliance. All input signals are specified with tR = tF = 5 ns (10% to 90% of VDD) and timed from a voltage level of 1.6 V.  
9 See Figure 3 and Figure 4.  
10 These numbers are measured with the load circuit of Figure 2 and defined as the time required for the output to cross the VOL or VOH limits.  
11 SCLK active edge is falling edge of SCLK.  
12 These numbers are derived from the measured time taken by the data output to change 0.5 V when loaded with the circuit of Figure 2. The measured number is then  
extrapolated back to remove the effects of charging or discharging the 50 pF capacitor. This means that the times quoted in the timing characteristics are the true bus  
relinquish times of the part and, as such, are independent of external bus loading capacitances.  
13 RDY  
RDY  
is high,  
returns high after a read of the ADC. In single conversion mode and continuous conversion mode, the same data can be read again, if required, while  
although care should be taken to ensure that subsequent reads do not occur close to the next output update. In continuous read mode, the digital word can be read  
only once.  
REV. PrD. Page 6 of 17  
 
 
 
 
 
 
 
 
Preliminary Technical Data  
AD7798/AD7799  
TO OUTPUT PIN  
+1.6 V  
50 pF  
Figure 2. Load Circuit for Timing Characterization  
CS (I)  
t6  
t1  
t5  
MSB  
LSB  
t7  
DOUT/RDY (O)  
t2  
t3  
SCLK (I)  
t4  
04227-0-003  
I = INPUT, O = OUTPUT  
Figure 3. Read Cycle Timing Diagram  
CS (I)  
t11  
t8  
SCLK (I)  
DIN (I)  
t9  
t10  
MSB  
LSB  
04227-0-004  
I = INPUT, O = OUTPUT  
Figure 4. Write Cycle Timing Diagram  
REV. PrD. Page 7 of 17  
AD7798/AD7799  
Preliminary Technical Data  
ABSOLUTE MAXIMUM RATINGS  
Table 3. (TA= 25°C, unless otherwise noted.)  
Parameter  
Rating  
AVDD to GND  
-0.3V to +7V  
Stresses above those listed under Absolute Maximum Ratings  
may cause permanent damage to the device. This is a stress  
rating only; functional operation of the device at these or any  
other conditions above those listed in the operational sections  
of this specification is not implied. Exposure to absolute  
maximum rating conditions for extended periods may affect  
device reliability.  
DVDD to GND  
-0.3V to +7V  
Analog Input Voltage to GND  
Reference Input Voltage to GND  
Digital Input Voltage to GND  
Digital Output Voltage to GND  
AIN/digital Input Current  
Operating Temperature Range  
Storage Temperature Range  
Maximum Junction Temperature  
TSSOP  
–0.3 V to AVDD + 0.3 V  
–0.3 V to AVDD + 0.3 V  
–0.3 V to DVDD + 0.3 V  
–0.3 V to DVDD + 0.3 V  
10 mA  
–40°C to +105°C  
–65°C to +150°C  
150°C  
θJA Thermal Impedance  
θJC Thermal Impedance  
Lead Temperature, Soldering  
Vapor Phase (60 sec)  
97.9°C/W  
14°C/W  
215°C  
220°C  
Infrared  
REV. PrD. Page 8 of 17  
 
Preliminary Technical Data  
AD7798/AD7799  
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS  
1
2
3
4
5
16  
15  
14  
13  
12  
SCLK  
CS  
DIN  
DOUT/RDY  
AIN3(+)/P1  
AIN3(-)/P2  
AIN1(+)  
DV  
DD  
AD7799/98  
AV  
DD  
TOP VIEW  
(Not To Scale)  
GND  
6
11  
10  
9
AIN1(-)  
AIN2(+)  
AIN2(-)  
PWRSW  
REFIN(-)  
REFIN(+)  
7
8
Figure 5. Pin Configuration  
Table 4. Pin Function Descriptions  
Pin  
No. Mnemonic  
Function  
1
SCLK  
Serial Clock Input for Data Transfers to and from the ADC. The SCLK has a Schmitt-triggered input, making  
the interface suitable for opto-isolated applications. The serial clock can be continuous with all data  
transmitted in a continuous train of pulses. Alternatively, it can be a noncontinuous clock with the  
information being transmitted to or from the ADC in smaller batches of data.  
2
CS  
Chip Select Input. This is an active low logic input used to select the ADC. CS can be used to select the ADC  
in systems with more than one device on the serial bus or as a frame synchronization signal in communi-  
cating with the device. CS can be hardwired low, allowing the ADC to operate in 3-wire mode with SCLK,  
DIN, and DOUT used to interface with the device.  
3
4
AIN3(+)/P1  
AIN3(–)/P2  
Analog Input/Digital Output pin. AIN3(+) is the positive terminal of the differential analog input pair  
AIN3(+)/AIN3(-). Alternatively, this pin can function as a general purpose output bit referenced between  
AVDD and GND  
Analog Input/ Digital Output pin. AIN3(–) is the negative terminal of the differential analog input pair  
AIN3(+)/AIN3(-). Alternatively, this pin can function as a general purpose output bit referenced between  
AVDD and GND  
5
6
7
8
9
AIN1(+)  
AIN1(-)  
AIN2(+)  
AIN2(-)  
REFIN(+)  
Analog Input. AIN1(+) is the positive terminal of the differential analog input pair AIN1(+)/AIN1(-).  
Analog Input. AIN1(–) is the negative terminal of the differential analog input pair AIN1(+)/AIN1(-).  
Analog Input. AIN2(+) is the positive terminal of the differential analog input pair AIN2(+)/AIN2(-).  
Analog Input. AIN2(–) is the negative terminal of the differential analog input pair AIN2(+)/AIN2(-).  
Positive Reference Input. REFIN(+) can lie anywhere between AVDD and GND + 0.1 V.  
The nominal reference voltage (REFIN(+) – REFIN(–)) is 2.5 V, but the part functions with a reference from 0.1  
V to AVDD  
.
10  
11  
12  
13  
14  
REFIN(-)  
PSW  
Negative Reference Input. This reference input can lie anywhere between GND and AVDD – 0.1 V.  
Low Side Power Switch to GND.  
GND  
Ground Reference Point.  
AVDD  
Supply Voltage, 2.7 V to 5.25 V.  
DVDD  
Serial Interface Supply voltage, 2.7 V to 5 V. DVDD is independent of AVDD, therefore the serial interface can  
be operated at 3V with VDD at 5V or vice versa.  
15  
DOUT/RDY  
Serial Data Output/Data Ready Output. DOUT/RDY serves a dual purpose . It functions as a serial data output  
pin to access the output shift register of the ADC. The output shift register can contain data from any of the  
on-chip data or control registers. In addition, DOUT/RDY operates as a data ready pin,  
going low to indicate the completion of a conversion. If the data is not read after the conversion, the pin will  
go high before the next update occurs.  
The DOUT/RDY falling edge can be used as an interrupt to a processor, indicating that valid data is available.  
With an external serial clock, the data can be read using the DOUT/RDY pin. With CS low, the data/control  
word informa-tion is placed on the DOUT/RDY pin on the SCLK falling edge and is valid on the SCLK rising  
edge.  
The end of a conversion is also indicated by the RDY bit in the status register. When CS is high, the  
DOUT/RDY pin is three-stated but the RDY bit remains active.  
REV. PrD. Page 9 of 17  
 
AD7798/AD7799  
Preliminary Technical Data  
Pin  
No. Mnemonic  
Function  
16  
DIN  
Serial Data Input to the Input Shift Register on the ADC. Data in this shift register is transferred to the control  
registers within the ADC, the register selection bits of the communications register identifying the  
appropriate register.  
REV. PrD. Page 10 of 17  
Preliminary Technical Data  
AD7798/AD7799  
TYPICAL PERFORMANCE CHARACTERISTICS  
Figure 6.  
Figure 7.  
Figure 8.  
Figure 9.  
Figure 10.  
Figure 11.  
REV. PrD. Page 11 of 17  
 
AD7798/AD7799  
Preliminary Technical Data  
ON-CHIP REGISTERS  
The ADC is controlled and configured via a number of on-chip registers, which are described on the following pages. In the following  
descriptions, set implies a Logic 1 state and cleared implies a Logic 0 state, unless otherwise stated.  
COMMUNICATIONS REGISTER (RS2, RS1, RS0 = 0, 0, 0)  
The communications register is an 8-bit write-only register. All communications to the part must start with a write operation to the com-  
munications register. The data written to the communications register determines whether the next operation is a read or write operation,  
and to which register this operation takes place. For read or write operations, once the subsequent read or write operation to the selected  
register is complete, the interface returns to where it expects a write operation to the communications register. This is the default state of  
the interface and, on power-up or after a reset, the ADC is in this default state waiting for a write operation to the communications regis-  
ter. In situations where the interface sequence is lost, a write operation of at least 32 serial clock cycles with DIN high returns the ADC to  
this default state by resetting the entire part. Table 5 outlines the bit designations for the communications register. CR0 through CR7 indi-  
cate the bit location, CR denoting the bits are in the communications register. CR7 denotes the first bit of the data stream. The number in  
brackets indicates the power-on/reset default status of that bit.  
CR7  
CR6  
CR5  
CR4  
CR3  
CR2  
CR1  
CR0  
WEN(0)  
R/W(0)  
RS2(0)  
RS1(0)  
RS0(0)  
CREAD(0)  
0(0)  
0(0)  
Table 5. Communications Register Bit Designations  
Bit Location  
Bit Name  
Description  
CR7  
WEN  
Write Enable Bit. A 0 must be written to this bit so that the write to the communications register actually  
occurs. If a 1 is the first bit written, the part will not clock on to subsequent bits in the register. It will stay  
at this bit location until a 0 is written to this bit. Once a 0 is written to the WEN bit, the next seven bits  
will be loaded to the communications register.  
CR6  
R/W  
A 0 in this bit location indicates that the next operation will be a write to a specified register. A 1 in this  
position indicates that the next operation will be a read from the designated register.  
CR5–CR3  
CR2  
RS2–RS0  
CREAD  
Register Address Bits. These address bits are used to select which of the ADC’s registers are being  
selected during this serial interface communication. See Table 6.  
Continuous Read of the Data Register. When this bit is set to 1 (and the data register is selected), the  
serial interface is configured so that the data register can be continuously read, i.e., the contents of the  
data register are placed on the DOUT pin automatically when the SCLK pulses are applied. The commu-  
nications register does not have to be written to for data reads. To enable continuous read mode, the  
instruction 01011100 must be written to the communications register. To exit the continuous read  
mode, the instruction 01011000 must be written to the communications register while the RDY pin is  
low. While in continuous read mode, the ADC monitors activity on the DIN line so that it can receive the  
instruction to exit continuous read mode. Additionally, a reset will occur if 32 consecutive 1s are seen on  
DIN. Therefore, DIN should be held low in continuous read mode until an instruction is to be written to  
the device.  
CR1–CR0  
0
These bits must be programmed to logic 0 for correct operation.  
Table 6. Register Selection  
RS2  
RS1  
RS0  
Register  
Register Size  
8-Bit  
8-Bit  
0
0
0
0
0
0
0
0
1
Communications Register during a Write Operation  
Status Register during a Read Operation  
Mode Register  
16-Bit  
0
1
0
Configuration Register  
16-Bit  
0
1
1
Data Register  
24-Bit (AD7799)  
16-bit (AD7798)  
8-Bit  
1
1
1
0
0
1
0
1
0
ID Register  
IO Register  
Offset Register  
8-Bit  
24-Bit (AD7799)  
16-bit (AD7798)  
24-Bit (AD7799)  
16-Bit (AD7798)  
1
1
1
Full-Scale Register  
REV. PrD. Page 12 of 17  
 
 
 
Preliminary Technical Data  
AD7798/AD7799  
STATUS REGISTER (RS2, RS1, RS0 = 0, 0, 0; POWER-ON/RESET = 0x88)  
The status register is an 8-bit read-only register. To access the ADC status register, the user must write to the communications register,  
select the next operation to be a read, and load bits RS2, RS1 and RS0 with 0. Table 7 outlines the bit designations for the status register.  
SR0 through SR7 indicate the bit locations, SR denoting the bits are in the status register. SR7 denotes the first bit of the data stream. The  
number in brackets indicates the power-on/reset default status of that bit.  
SR7  
SR6  
SR5  
SR4  
SR3  
SR2  
SR1  
SR0  
RDY(1)  
ERR(0)  
NOREF(0)  
0(0)  
0/1  
CH2(0)  
CH1(0)  
CH0(0)  
Table 7. Status Register Bit Designations  
Bit Location  
Bit Name  
Description  
SR7  
RDY  
Ready bit for ADC. Cleared when data is written to the ADC data register. The RDY bit is set automatically  
after the ADC data register has been read or a period of time before the data register is updated with a  
new conversion result to indicate to the user not to read the conversion data. It is also set when the part  
is placed in power-down mode. The end of a conversion is indicated by the DOUT/RDY pin also. This pin  
can be used as an alternative to the status register for monitoring the ADC for conversion data.  
SR6  
SR5  
ERR  
ADC Error Bit. This bit is written to at the same time as the RDY bit. Set to indicate that the result written  
to the ADC data register has been clamped to all 0s or all 1s. Error sources include overrange,  
underrange, NOREF Cleared by a write operation to start a conversion.  
NOREF  
No Reference Bit. Set to indicate that one or both of the REFIN pins is floating or the applied voltage is  
below a specified threshold. When set, conversion results are clamped to all ones.  
Cleared to indicate that a valid reference is applied between REFIN(+) and REFIN(-).  
The NOREF bit is enabled by setting the REF_DET bit in the Configuration register to 1. The ERR bit is  
also set if the voltage applied to the reference input is invalid.  
SR4  
0
This bit is automatically cleared.  
SR3  
0/1  
This bit is automatically cleared on the AD7798, and is automatically set on the AD7799.  
These bits indicate which channel is being converted by the ADC.  
SR2–SR0  
CH2–CH0  
MODE REGISTER (RS2, RS1, RS0 = 0, 0, 1; POWER-ON/RESET = 0x000A)  
The mode register is a 16-bit register from which data can be read or to which data can be written. This register is used to configure the  
Low Side Power Switch, select the mode of the ADC and select the ADC update rate. Table 8 outlines the bit designations for the mode  
register. MR0 through MR15 indicate the bit locations, MR denoting the bits are in the mode register. MR15 denotes the first bit of the  
data stream. The number in brackets indicates the power-on/reset default status of that bit. Any write to the setup register resets the  
modulator and filter and sets the  
bit.  
RDY  
MR15  
MD2(0)  
MR7  
(0)  
MR14  
MD1(0)  
MR6  
(0)  
MR13  
MD0(0)  
MR5  
MR12  
PSW(0)  
MR4  
MR11  
0(0)  
MR10  
0(0)  
MR9  
0(0)  
MR8  
0(0)  
MR3  
FS3(1)  
MR2  
FS2(0)  
MR1  
FS1(1)  
MR0  
FS0(0)  
0(0)  
0(0)  
Table 8. Mode Register Bit Designations  
Bit Location  
MR15–MR13  
MR12  
Bit Name  
MD2–MD0  
PSW  
Description  
Mode Select Bits. These bits select the operational mode of the AD7798/AD7799 (See Table 9).  
Power Switch Control Bit.  
Set by user to close the power switch PSW to GND. The power switch can sink up to 20 mA.  
Cleared by user to open the power switch.  
When the ADC is placed in power-down mode, the power switch is opened.  
These bits must be programmed with a Logic 0 for correct operation.  
Filter Update Rate Select Bits (see Table 10).  
MR11-MR4  
MR3-MR0  
0
FS3-FS0  
REV. PrD. Page 13 of 17  
 
 
 
AD7798/AD7799  
Preliminary Technical Data  
Table 9. Operating Modes  
MD2  
MD1  
MD0  
Mode  
0
0
0
Continuous Conversion Mode (Default).  
In continuous conversion mode, the ADC continuously performs conversions and places the result in the data  
register. RDY goes low when a conversion is complete. The user can read these conversions by placing the  
device in continuous read mode whereby the conversions are automatically placed on the DOUT line when  
SCLK pulses are applied. Alternatively, the user can instruct the ADC to output the conversion by writing to  
the communications register. After power-on, or following a write to the Mode, Configuration or IO  
Registers, a conversion is available after a period 2/ fADC while subsequent conversions are available at a  
frequency of fADC  
.
0
0
1
Single Conversion Mode.  
In single conversion mode, the ADC is placed in power-down mode when conversions are not being  
performed. When single conversion mode is selected, the ADC powers up and performs a single conversion,  
which occurs after a period 2/fADC. The conversion result in placed in the data register, RDY goes low, and the  
ADC returns to power-down mode. The conversion remains in the data register and RDY remains active (low)  
until the data is read or another conversion is performed.  
0
0
1
1
1
0
0
1
0
Idle Mode.  
In Idle Mode, the ADC Filter an Modulator are held in a reset state although the modulator clocks are still  
provided  
Power-Down Mode.  
In power down mode, all the AD7798/99 circuitry is powered down including the power switch and  
burnout currents.  
Internal Zero-Scale Calibration.  
An internal short is automatically connected to the enabled channel. A calibration takes 2 conversion cycles  
to complete. RDY goes high when the calibration is initiated and returns low when the the calibration is  
complete. The ADC is placed in idle mode following a calibration. The measured offset coefficient is placed in  
the offset register of the selected channel.  
1
0
1
Internal Full-Scale Calibration.  
The fullscale input is automatically connected to the selected analog input for this calibration. When the gain  
equals 1, a calibration takes 2 conversion cycles to complete. For higher gains, 4 conversion cycles are  
required for the fullscale calibration. RDY goes high when the calibration is initiated and returns low when  
the calibration is complete. The ADC is placed in idle mode following a calibration. The measured full-scale  
calibration coefficient is placed in the fullscale register of the selected channel. A fullscale calibration is  
required each time the gain of a channel is changed. The full-scale error of the AD7799/AD7798 is calibrated  
in the factory at both a gain of 1 and 128. These values are loaded into the fullscale register when the gain is 1  
or 128. If a different PGA gain is used, then an Internal Full-Scale Calibration is required to calibrate out the  
gain error associated with that PGA gain. Note that Internal Fullscale Calibrations cannot be performed at a  
gain of 128.  
1
1
1
1
0
1
System Offset Calibration.  
User should connect the system zero-scale input to the channel input pins as selected by the CH2-CH0 bits.  
A system offset calibration takes 2 conversion cycles to complete. RDY goes high when the calibration is  
initiated and returns low when the calibration is complete. The ADC is placed in idle mode following a  
calibration. The measurded offset calibration coefficient is placed in the offset register of the selected  
channel.  
System Full-Scale Calibration.  
User should connect the system full-scale input to the channel input pins s selected by the CH2-CH0 bits. A  
system full-scale calibration takes 2 conversion cycles to complete. RDY goes high when the calibration is  
initiated and returns low when the calibration is complete. The ADC is placed in idle mode following a  
calibration. The measured full-scale calibration coefficient is placed in the fullscale register of the selected  
channel.  
REV. PrD. Page 14 of 17  
Preliminary Technical Data  
AD7798/AD7799  
Table 10. Update Rates Available  
Tsettle  
(ms)  
x
FS3  
0
FS2  
0
FS1  
0
FS0  
0
fADC (Hz)  
x
Rejection @50 Hz/60 Hz  
0
0
0
0
0
0
0
1
0
1
1
0
1
0
1
0
500  
250  
125  
62.5  
50  
5
8
16  
32  
0
1
0
1
40  
0
0
1
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
1
0
0
1
1
0
0
1
0
1
0
1
0
1
0
1
0
41.6  
33.3  
19.6  
16.6  
16.6  
12.5  
10  
8.33  
6.25  
4.17  
48  
60  
101  
120  
120  
160  
200  
240  
320  
480  
90 dB (60 Hz only)  
84 dB (50 Hz only)  
70 dB (50 Hz and 60 Hz)  
67 dB (50 Hz and 60 Hz)  
69 dB (50 Hz and 60 Hz)  
73 dB (50 Hz and 60 Hz)  
74 dB (50 Hz and 60 Hz)  
75 dB @ 50/60 Hz  
1
1
1
1
CONFIGURATION REGISTER (RS2, RS1, RS0 = 0, 1, 0; POWER-ON/RESET = 0x0710)  
The configuration register is a 16-bit register from which data can be read or to which data can be written. This register is used to configure  
the ADC for unipolar or bipolar mode, enable or disable the buffer, enable or disable the burnout currents, select the gain and select the ana-  
log input channel. CON0 through CON15 indicate the bit locations, CON denoting the bits are in the configuration register. CON15  
denotes the first bit of the data stream. The number in brackets indicates the power-on/reset default status of that bit.  
CON15  
CON14  
CON13  
BO(0)  
CON12  
U/B (0)  
CON4  
CON11  
0(0)  
CON10  
G2(1)  
CON9  
G1(1)  
CON8  
G0(1)  
0
0
CON7  
CON6  
CON5  
CON3  
0(0)  
CON2  
CH2(0)  
CON1  
CH1(0)  
CON0  
CH0(0)  
0
0
REF_DET(0)  
BUF(1)  
Table 11. Configuration Register Bit Designations  
Bit Location  
CON15–CON14  
CON13  
Bit Name  
Description  
0
BO  
These bits must be programmed with a logic 0 for correct operation.  
Burnout Current Enable Bit. When this bit is set to 1 by the user, the 100 nA current sources in the  
signal path are enabled. When BO = 0, the burnout currents are disabled. The burnout currents  
can be enabled only when the buffer or In-Amp is active.  
CON12  
U/B  
Unipolar/Bipolar Bit. Set by user to enable unipolar coding, i.e., zero differential input will result in  
0x0000(00) output and a full-scale differential input will result in 0XFFFF(FF) output for the  
AD7798(99).  
Cleared by the user to enable bipolar coding. Negative full-scale differential input will result in an  
output code of 0x0000(00), zero differential input will result in an output code of 0x8000(00), and  
a positive full-scale differential input will result in an output code of 0xFFFF(FF) for the  
AD7798(99).  
CON11  
CON10-CON8  
0
This bit must be programmed with a Logic 0 for correct operation.  
Gain Select Bits.  
G2-G0  
Written by the user to select the ADC input range as follows  
G2  
G1  
G0  
Gain  
ADC Input Range (2.5V Reference)  
0
0
0
1 (In-Amp not  
used)  
2.5 V  
0
0
1
2 (In-Amp not  
used)  
1.25 V  
REV. PrD. Page 15 of 17  
 
AD7798/AD7799  
Preliminary Technical Information  
Bit Location  
Bit Name  
Description  
0
0
1
1
1
1
1
1
0
0
1
1
0
1
0
1
0
1
4
625 mV  
8
312.5 mV  
156.2 mV  
78.125 mV  
39.06 mV  
19.53 mV  
16  
32  
64  
128  
CON7-CON6  
CON5  
0
These bits must be programmed to a logic 0 for correct operation.  
Enables the Reference Detect Function.  
REF_DET  
When set, the NOREF bit in the status register indicates when the reference being used by the  
ADC is not present.  
When cleared, the reference detect function is disabled.  
CON4  
BUF  
Configures the ADC for buffered or unbuffered mode of operation. If cleared, the ADC operates in  
unbuffered mode, lowering the power consumption of the device. If set, the ADC operates in  
buffered mode, allowing the user to place source impedances on the front end without  
contributing gain errors to the system.  
CON3  
CON2-CON0  
0
This bits must be programmed to a logic 0 for correct operation.  
Channel Select bits.  
CH2-CH0  
Written by the user to select the active analog input channel to the ADC.  
CH2 CH1 CH0 Channel  
Calibration Pair  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
AIN1(+) – AIN1(-)  
AIN2(+) – AIN2(-)  
AIN3(+) – AIN3(-)  
AIN1(-) – AIN1(-)  
Reserved  
0
1
2
0
Reserved  
Reserved  
VDD Monitor  
DATA REGISTER (RS2, RS1, RS0 = 0, 1, 1; POWER-ON/RESET = 0x0000 (AD7798)/ 0X000000 (AD7799))  
The conversion result from the ADC is stored in this data register. This is a read-only register. On completion of a read operation from  
this register, the  
bit/pin is set.  
RDY  
ID REGISTER (RS2, RS1, RS0 = 1, 0, 0; POWER-ON/RESET = 0xX8 (AD7798)/ 0xX9 (AD7799))  
The Identification Number for the AD7798/AD7799 is stored in the ID register. This is a read-only register.  
IO REGISTER (RS2, RS1, RS0 = 1, 0, 1; POWER-ON/RESET = 0x00)  
The I/O register is an 8-bit register from which data can be read or to which data can be written. IO0 through IO7 indicate  
the bit locations, IO denoting the bits are in the IO register. Table 12 outline the bit designations for the IO register. IO7 denotes the first  
bit of the data stream. The number in brackets indicates the power-on/reset default status of that bit.  
IO7  
IO6  
IO5  
IO4  
IO3  
IO2  
IO1  
IO0  
0
IOEN(0)  
IO2DAT(0)  
IO1DAT(0)  
0
0
0
0
Table 12. I/O register Bit Designations  
Bit Location  
Bit Name  
Description  
IO7  
IO6  
0
These bits must be programmed to a logic 0 for correct operation.  
IOEN  
Configures the pins AIN3(+)/P1 and AIN3(-)/P2 as analog input pins or digital output pins.  
When this bit is set, the pins are configured as digital output pins P1 and P2.  
When this bit is cleared, these pins are configured as analog input pins AIN3(+) and AIN3(-).  
IO5-IO4  
IO3-IO0  
IO2DAT/IO1DAT P2/P1 Data.  
These bits must be programmed to a logic 0 for correct operation.  
0
REV. PrD. Page 16 of 17  
 
Preliminary Technical Information  
AD7798/AD7799  
OFFSET REGISTER (RS2, RS1, RS0 = 1, 1, 0; Power-on/Reset = 0x8000 (AD7798)/0x800000 (AD7799))  
The offset register holds the offset calibration coefficient for the ADC. The power-on-reset value of the internal zero-scale calibration  
coefficient register is 8000 hex (AD7798)/800000 hex (AD7799). The AD7798/AD7799 has 3 offset registers. Each of these registers is a  
16/24-bit read/write register. However, when writing to the offset-scale registers, the ADC must be placed in power down mode or idle  
mode. This register is used in conjunction with its associated full-scale register to form a register pair. The power-on-reset value is  
automatically overwritten if an internal or system zero-scale calibration is initiated by the user.  
FULLSCALE Register (RS2, RS1, RS0 = 1, 1, 1; Power-on/Reset = 0x5XXX (AD7798)/0x5XXX000 (AD7799))  
The full-scale register holds the full-scale calibration coefficient for the ADC. The AD7798/AD7799 has 3 full-scale registers. Each of  
these registers is a 16/24-bit read/write register. However, when writing to the full-scale registers, the ADC must be placed in power  
down mode or idle mode. The full-scale error of the AD7799/AD7798 is calibrated in the factory at both a gain of 1 and 128. Therefore if  
the gain is set to 128, as on power-on, or if the gain is set to 1, the factory calibrated internal full-scale coefficients are automatically  
loaded into the full-scale registers of the AD7799/AD7798. Therefore, every device will have different default coefficients. The user can  
overwrite these values, if required. These coefficients will be automatically overwritten if an internal or system full-scale calibration is  
initiated by the user. A full-scale calibration should be performed when the gain is changed. When the gain equals 128, internal full-scale  
calibrations cannot be performed.  
TYPICAL APPLICATION  
AV  
DD  
GND  
REFIN(+)  
AV  
DD  
REFERENCE  
DETECT  
AD7799/AD7798  
AV  
DD  
IN+  
IN-  
AIN1(+)  
AIN1(-)  
OUT-  
OUT+  
SERIAL  
INTERFACE  
AND  
CONTROL  
LOGIC  
DOUT/RDY  
DIN  
SIGMA DELTA  
ADC  
IN-AMP  
MUX  
AIN2(+)  
AIN2(-)  
SCLK  
CS  
GND  
INTERNAL  
CLOCK  
REFIN(-)  
PWRSW  
DV  
DD  
Figure 12.  
REV. PrD. Page 17 of 17  
 

相关型号:

AD7799BRU

3-Channel, Low Noise, Low Power, 16-/24-Bit, ADC with On-Chip In-Amp
ADI

AD7799BRU-REEL

3-Channel, Low Noise, Low Power, 16-/24-Bit, ADC with On-Chip In-Amp
ADI

AD7799BRUZ

3-Channel, Low Noise, Low Power, 16-/24-Bit, ADC with On-Chip In-Amp
ADI

AD7799BRUZ

3-CH 24-BIT DELTA-SIGMA ADC, SERIAL ACCESS, PDSO16, ROHS COMPLIANT, MO-153AB, TSSOP-16
ROCHESTER

AD7799BRUZ-REEL

3-Channel, Low Noise, Low Power, 16-/24-Bit, Σ-Δ ADC with On-Chip In-Amp
ADI

AD7799BRUZ-REEL

3-CH 24-BIT DELTA-SIGMA ADC, SERIAL ACCESS, PDSO16, ROHS COMPLIANT, MO-153AB, TSSOP-16
ROCHESTER

AD7799_15

3-Channel, Low Noise, Low Power
ADI

AD779AD

14-Bit 128 kSPS Complete Sampling ADC
ADI

AD779AJ

Analog-to-Digital Converter, 14-Bit
ETC

AD779BD

14-Bit 128 kSPS Complete Sampling ADC
ADI

AD779BJ

Analog-to-Digital Converter, 14-Bit
ETC

AD779JD

14-Bit 128 kSPS Complete Sampling ADC
ADI