AD8494 [ADI]
Precision Thermocouple Amplifiers with Cold Junction Compensation; 精密热电偶放大器,冷端补偿型号: | AD8494 |
厂家: | ADI |
描述: | Precision Thermocouple Amplifiers with Cold Junction Compensation |
文件: | 总16页 (文件大小:481K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Precision Thermocouple Amplifiers
with Cold Junction Compensation
AD8494/AD8495/AD8496/AD8497
FEATURES
FUNCTIONAL BLOCK DIAGRAM
SENSE
Low cost and easy to use
AD8494/AD8495/
Pretrimmed for J or K type thermocouples
Internal cold junction compensation
High impedance differential input
Standalone 5 mV/°C thermometer
Reference pin allows offset adjustment
Thermocouple break detection
Laser wafer trimmed to 1°C initial accuracy
and 0.025°C/°C ambient temperature rejection
Low power: <1 mW at VS = 5 V
AD8496/AD8497
–IN
ESD AND
OVP
A2
1MΩ
COLD JUNCTION
COMPENSATION
THERMO-
COUPLE
A3
OUT
A1
+IN
ESD AND
OVP
Wide power supply range
Single supply: 2.7 V to 36 V
Dual supply: 2.7 V to 18 V
REF
Figure 1.
Small, 8-lead MSOP
APPLICATIONS
Table 1. Device Temperature Ranges
Optimized Temperature Range
J or K type thermocouple temperature measurement
Setpoint controller
Celsius thermometer
Universal cold junction compensator
White goods (oven, stove top) temperature measurements
Exhaust gas temperature sensing
Thermo-
couple
Part No. Type
Ambient Temperature Measurement
(Reference Junction) Junction
AD8494
AD8495
AD8496
AD8497
J
K
J
0°C to 50°C
0°C to 50°C
25°C to 100°C
25°C to 100°C
Full J type range
Full K type range
Full J type range
Full K type range
K
Catalytic converter temperature sensing
GENERAL DESCRIPTION
The AD8494/AD8495/AD8496/AD8497 are precision instrumen-
tation amplifiers with thermocouple cold junction compensators
on an integrated circuit. They produce a high level (5 mV/°C)
output directly from a thermocouple signal by combining an
ice point reference with a precalibrated amplifier. They can be
used as standalone thermometers or as switched output setpoint
controllers using either a fixed or remote setpoint control.
The AD8494/AD8495/AD8496/AD8497 allow a wide variety of
supply voltages. With a 5 V single supply, the 5 mV/°C output
allows the devices to cover nearly 1000 degrees of a thermo-
couple’s temperature range.
The AD8494/AD8495/AD8496/AD8497 work with 3 V supplies,
allowing them to interface directly to lower supply ADCs. They
can also work with supplies as large as 36 V in industrial systems
that require a wide common-mode input range.
The AD8494/AD8495/AD8496/AD8497 can be powered from a
single-ended supply (less than 3 V) and can measure temperatures
below 0°C by offsetting the reference input. To minimize self-
heating, an unloaded AD849x typically operates with a total
supply current of 180 μA, but it is also capable of delivering in
excess of 5 mA to a load.
PRODUCT HIGHLIGHTS
1. Complete, precision laser wafer trimmed thermocouple
signal conditioning system in a single IC package.
2. Flexible pinout provides for operation as a setpoint
controller or as a standalone Celsius thermometer.
3. Rugged inputs withstand 4 kV ESD and provide over-
voltage protection (OVP) up to VS 25 V.
4. Differential inputs reject common-mode noise on the
thermocouple leads.
5. Reference pin voltage can be offset to measure 0°C on
single supplies.
The AD8494 and AD8496 are precalibrated by laser wafer
trimming to match the characteristics of J type (iron-constantan)
thermocouples; the AD8495 and AD8497 are laser trimmed to
match the characteristics of K type (chromel-alumel) thermo-
couples. See Table 1 for the optimized ambient temperature
range of each part.
6. Available in a small, 8-lead MSOP that is fully RoHS compliant.
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registeredtrademarks arethe property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
Fax: 781.461.3113
www.analog.com
©2010 Analog Devices, Inc. All rights reserved.
AD8494/AD8495/AD8496/AD8497
TABLE OF CONTENTS
Features .............................................................................................. 1
Thermocouples........................................................................... 11
Thermocouple Signal Conditioner.......................................... 11
AD8494/AD8495/AD8496/AD8497 Architecture.................. 11
Maximum Error Calculation.................................................... 12
Recommendations for Best Circuit Performance.................. 13
Applications Information.............................................................. 14
Basic Connection ....................................................................... 14
Ambient Temperature Sensor................................................... 14
Setpoint Controller .................................................................... 15
Measuring Negative Temperatures .......................................... 15
Reference Pin Allows Offset Adjustment................................ 15
Outline Dimensions....................................................................... 16
Ordering Guide .......................................................................... 16
Applications....................................................................................... 1
Functional Block Diagram .............................................................. 1
General Description......................................................................... 1
Product Highlights ........................................................................... 1
Revision History ............................................................................... 2
Specifications..................................................................................... 3
Absolute Maximum Ratings............................................................ 5
Thermal Resistance ...................................................................... 5
ESD Caution.................................................................................. 5
Pin Configuration and Function Descriptions............................. 6
Typical Performance Characteristics ............................................. 7
Theory of Operation ...................................................................... 11
REVISION HISTORY
7/10—Revision 0: Initial Version
Rev. 0 | Page 2 of 16
AD8494/AD8495/AD8496/AD8497
SPECIFICATIONS
+VS = 5 V, −VS = 0 V, V+IN = V−IN = 0 V, VREF = 0 V, TA = TRJ = 25°C, RL = 100 kΩ, unless otherwise noted. Specifications do not include
gain and offset errors of the thermocouple itself. TA is the ambient temperature at the AD849x; TRJ is the thermocouple reference junction
temperature; TMJ is the thermocouple measurement junction temperature.
Table 2.
A Grade
Typ
C Grade
Typ
Parameter
Test Conditions/Comments
Min
Max
Min
Max
Unit
TEMPERATURE ACCURACY
Initial Accuracy
AD8494/AD8495
AD8496/AD8497
TA = TRJ = TMJ = 25°C
TA = TRJ = 60°C, TMJ = 175°C
3
3
1
1.5
°C
°C
Ambient Temperature
Rejection1
AD8494/AD8495
AD8496/AD8497
Gain Error2, 3
TA = TRJ = 0°C to 50°C
TA = TRJ = 25°C to 100°C
VOUT = 0.125 V to 4.125 V
0.05
0.05
0.025
0.025
°C/°C
°C/°C
AD8494/AD8495
AD8496/AD8497
Transfer Function
INPUTS
0.3
0.3
0.1
0.1
%
%
mV/°C
5
5
Input Voltage Range
Overvoltage Range
Input Bias Current4
Input Offset Current
Common-Mode Rejection
Power Supply Rejection
NOISE
−VS – 0.2
+VS – 25
+VS – 1.6 −VS – 0.2
−VS + 25 +VS – 25
50
1.5
1
+VS – 1.6
−VS + 25
50
0.5
0.3
V
V
nA
nA
°C/V
°C/V
25
25
VCM = 0 V to 3 V
+VS = 2.7 V to 5 V
0.5
0.5
Voltage Noise
f = 0.1 Hz to 10 Hz, TA = 25°C
f = 1 kHz, TA = 25°C
f = 1 kHz, TA = 25°C
0.8
32
100
0.8
32
100
μV p-p
nV/√Hz
fA/√Hz
Voltage Noise Density
Current Noise Density
REFERENCE INPUT
Input Resistance
Input Current
60
25
60
25
kΩ
μA
V
Voltage Range
−VS
+VS
−VS
+VS
Gain to Output
OUTPUT
1
7
1
7
V/V
Output Voltage Range
Short-Circuit Current5
DYNAMIC RESPONSE
−3 dB Bandwidth
AD8494
−VS + 0.025
+VS – 0.1 −VS + 0.025
+VS – 0.1
V
mA
30
25
31
30
25
31
kHz
kHz
kHz
AD8495/AD8497
AD8496
Settling Time to 0.1%
AD8494
AD8495/AD8497
AD8496
4 V output step
36
40
32
36
40
32
μs
μs
μs
POWER SUPPLY
Operating Voltage Range6
Single Supply
Dual Supply
Quiescent Current
2.7
2.7
36
18
250
2.7
2.7
36
18
250
V
V
μA
180
180
Rev. 0 | Page 3 of 16
AD8494/AD8495/AD8496/AD8497
A Grade
Typ
C Grade
Typ
Parameter
Test Conditions/Comments
Min
Max
Min
Max
Unit
TEMPERATURE RANGE (TA)
Specified Performance
AD8494/AD8495
AD8496/AD8497
Operational
0
25
−40
50
100
+125
0
25
−40
50
100
+125
°C
°C
°C
1 Ambient temperature rejection specifies the change in the output measurement (in °C) for a given change in temperature of the cold junction. For the AD8494 and
AD8495, ambient temperature rejection is defined as the slope of the line connecting errors calculated at 0°C and 50°C ambient temperature. For the AD8496 and
AD8497, ambient temperature rejection is defined as the slope of the line connecting errors calculated at 25°C and 100°C ambient temperature.
2 Error does not include thermocouple gain error or thermocouple nonlinearity.
3 With a 100 kΩ load, measurement junction temperatures beyond approximately 880°C for the AD8494 and AD8496 and beyond approximately 960°C for the AD8495
and AD8497 require supply voltages larger than 5 V or a negative voltage applied to the reference pin. Measurement junction temperatures below 5°C require either a
positive offset voltage applied to the reference pin or a negative supply.
4 Input stage uses PNP transistors, so bias current always flows out of the part.
5 Large output currents can increase the internal temperature rise of the part and contribute to cold junction compensation (CJC) error.
6 Unbalanced supplies can also be used. Care should be taken that the common-mode voltage of the thermocouple stays within the input voltage range of the part.
Rev. 0 | Page 4 of 16
AD8494/AD8495/AD8496/AD8497
ABSOLUTE MAXIMUM RATINGS
THERMAL RESISTANCE
Table 3.
θJA is specified for a device on a 4-layer JEDEC PCB in free air.
Parameter
Rating
Supply Voltage
18 V
Table 4.
Package
Maximum Voltage at −IN or +IN
Minimum Voltage at −IN or +IN
REF Voltage
+VS – 25 V
–VS + 25 V
VS
θJA
Unit
8-Lead MSOP (RM-8)
135
°C/W
Output Short-Circuit Current Duration
Storage Temperature Range
Operating Temperature Range
Maximum IC Junction Temperature
ESD
Indefinite
−65°C to +150°C
−40°C to +125°C
140°C
ESD CAUTION
Human Body Model
4.5 kV
Field-Induced Charged Device Model 1.5 kV
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Rev. 0 | Page 5 of 16
AD8494/AD8495/AD8496/AD8497
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
AD849x
–IN
1
2
3
4
8
7
6
5
+IN
+V
–
+
REF
S
–V
OUT
S
NC
SENSE
TOP VIEW
(Not to Scale)
NC = NO CONNECT
Figure 2. Pin Configuration
Table 5. Pin Function Descriptions
Pin No.
Mnemonic
Description
1
2
3
4
5
6
7
8
−IN
REF
−VS
NC
SENSE
OUT
+VS
Negative Input.
Reference. This pin must be driven by low impedance.
Negative Supply.
No Connect.
Sense Pin. In measurement mode, connect to output; in setpoint mode, connect to setpoint voltage.
Output.
Positive Supply.
Positive Input.
+IN
Rev. 0 | Page 6 of 16
AD8494/AD8495/AD8496/AD8497
TYPICAL PERFORMANCE CHARACTERISTICS
TA = 25°C, +VS = 5 V, RL = ∞, unless otherwise noted.
100
1200
AD8495/AD8497
AD8494
AD8496
1000
800
CONNECTED
10
1
THERMOCOUPLE
600
400
200
0.1
0.01
OPEN THERMOCOUPLE
0
THERMOCOUPLE CONNECTION
AD849x OUTPUT
–200
0.1
1
10
100
1k
10k
100k
TIME (50µs/DIV)
FREQUENCY (Hz)
Figure 6. Output Response to Open Thermocouple,
−IN Connected to Ground Through a 1 MΩ Resistor
Figure 3. CMRR vs. Frequency
1000
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0
AD8495/AD8497
AD8494
AD8496
+0.05, +3.45
+4.91, +2.95
+0.05, +3.21
100
10
1
+4.91, +2.71
+0.05, –0.36
+0.05, –0.39
+4.91, –0.37
+4.91, –0.39
–0.5
–1.0
V
V
= 0V
= 2.5V
REF
REF
0
1
10
100
1k
10k
100k
–0.5
0.5
1.5
2.5
3.5
4.5
5.5
FREQUENCY (Hz)
OUTPUT VOLTAGE (V)
Figure 4. PSRR vs. Frequency
Figure 7. Input Common-Mode Voltage Range vs. Output Voltage,
+VS = 5 V, VREF = 0 V, and VREF = 2.5 V
50
40
35
2.00
1.75
40
30
30
25
20
15
10
5
1.50
1.25
1.00
0.75
0.50
0.25
0
I
BIAS
20
10
AD8494
AD8496
AD8495/AD8497
0
–10
–20
I
OS
0
–40
100
1k
10k
FREQUENCY (Hz)
100k
1M
–20
0
20
40
60
80
100
120
TEMPERATURE (°C)
Figure 5. Frequency Response
Figure 8. Input Bias Current and Input Offset Current vs. Temperature
Rev. 0 | Page 7 of 16
AD8494/AD8495/AD8496/AD8497
3.00
2.75
2.50
2.00
16
3.0
2.5
2.0
1.5
12
8
1.50
1.00
0.50
0
V
OUT
2.25
2.00
1.75
1.50
1.25
1.00
0.75
0.50
0.25
0
V
OUT
4
0
1.0
0.5
0
I
IN
–4
–8
I
IN
–0.50
–1.00
–0.5
–1.0
–12
–16
–30 –25 –20 –15 –10 –5
0
5
10 15 20 25 30
–30 –25 –20 –15 –10 –5
0
5
10 15 20 25 30
INPUT VOLTAGE (V)
INPUT VOLTAGE (V)
Figure 9. AD8494 Input Overvoltage Performance, +VS = 2.7 V (Gain = 96.7)
Figure 12. AD8494 Input Overvoltage Performance, VS = 15 V (Gain = 96.7)
3.00
2.00
16
3.0
2.5
2.0
1.5
2.75
2.50
2.25
2.00
1.75
1.50
1.25
1.00
0.75
0.50
0.25
0
12
8
1.50
1.00
0.50
0
V
OUT
V
OUT
4
0
I
IN
1.0
0.5
0
–4
–8
I
IN
–0.50
–1.00
–0.5
–1.0
–12
–16
–30 –25 –20 –15 –10 –5
0
5
10 15 20 25 30
–30 –25 –20 –15 –10 –5
0
5
10 15 20 25 30
INPUT VOLTAGE (V)
INPUT VOLTAGE (V)
Figure 10. AD8495/AD8497 Input Overvoltage Performance,
+VS = 2.7 V (Gain = 122.4)
Figure 13. AD8495/AD8497 Input Overvoltage Performance,
VS = 15 V (Gain = 122.4)
3.00
2.00
16
3.0
2.5
2.75
2.50
2.25
2.00
1.75
1.50
1.25
1.00
0.75
0.50
0.25
0
12
8
1.50
1.00
0.50
0
V
V
2.0
1.5
OUT
OUT
4
0
I
IN
1.0
0.5
0
–4
–8
I
IN
–0.50
–1.00
–0.5
–1.0
–12
–16
–30 –25 –20 –15 –10 –5
0
5
10 15 20 25 30
–30 –25 –20 –15 –10 –5
0
5
10 15 20 25 30
INPUT VOLTAGE (V)
INPUT VOLTAGE (V)
Figure 11. AD8496 Input Overvoltage Performance, +VS = 2.7 V
Gain = 90.35)
Figure 14. AD8496 Input Overvoltage Performance, VS = 15 V (Gain = 90.35)
Rev. 0 | Page 8 of 16
AD8494/AD8495/AD8496/AD8497
C
C
= 0pF
= 1000pF
C
C
= 0pF
= 1000pF
L
L
L
L
C
C
= 4700pF
= 10000pF
C
C
= 4700pF
= 10000pF
L
L
L
L
120µs/DIV
120µs/DIV
Figure 15. AD8494/AD8496 Small-Signal Response
with Various Capacitive Loads
Figure 18. AD8495/AD8497 Small-Signal Response
with Various Capacitive Loads
AD8494/AD8496
AD8495/AD8497
2V/DIV
SETTLING TO 0.1% IN 36µs
0.02%/DIV
100µs/DIV
120µs/DIV
Figure 16. Small-Signal Response, RL = 100 kΩ, CL = 1 nF
Figure 19. AD8494 Large-Signal Step Response and Settling Time
2V/DIV
2V/DIV
SETTLING TO 0.1% IN 40µs
0.02%/DIV
SETTLING TO 0.1% IN 32µs
0.02%/DIV
100µs/DIV
100µs/DIV
Figure 17. AD8495/AD8497 Large-Signal Step Response and Settling Time
Figure 20. AD8496 Large-Signal Step Response and Settling Time
Rev. 0 | Page 9 of 16
AD8494/AD8495/AD8496/AD8497
OUTPUT VOLTAGE
5V POWER-UP
1s/DIV
TIME (1.5ms/DIV)
Figure 21. 0.1 Hz to 10 Hz RTI Voltage Noise
Figure 24. Output Voltage Start-Up
+V
5
4
S
–0.4
–0.8
–1.2
(+) –40°C
(+) +25°C
(+) +85°C
(+) +125°C
(+) –40°C
(+) +25°C
(+) +85°C
(+) +125°C
3
2
1
0
–1
(–) –40°C
(–) +25°C
(–) +85°C
(–) +125°C
(–) –40°C
(–) +25°C
(–) +85°C
(–) +125°C
–2
–3
–4
+1.2
+0.8
+0.4
–V
S
10µ
–5
1k
100µ
1m
5m
10k
100k
OUTPUT CURRENT (A)
LOAD RESISTANCE (Ω)
Figure 22. Output Voltage Swing vs. Load Resistance, VS = 5 V
Figure 25. Output Voltage Swing vs. Output Current, VS = 5 V
100
90
80
70
60
50
40
30
20
10
1
10
100
1k
10k
100k
FREQUENCY (Hz)
Figure 23. Voltage Noise Spectral Density vs. Frequency
Rev. 0 | Page 10 of 16
AD8494/AD8495/AD8496/AD8497
THEORY OF OPERATION
THERMOCOUPLES
Table 6. J Type Thermocouple Voltages and AD8494 Readings
A thermocouple is a rugged, low cost temperature transducer
whose output is proportional to the temperature difference
between a measurement junction and a reference junction. It
has a very wide temperature range. Its low level output (typically
tens of microvolts per °C) requires amplification. Variation in
the reference junction temperature results in measurement
error unless the thermocouple signal is properly compensated.
Measurement Reference
Junction
Temperature
Junction
Temperature Thermocouple AD8494
(TMJ
)
(TRJ)
Voltage
+2.585 mV
0 mV
0 mV
−2.585 mV
Reading
250 mV
250 mV
0 mV
50°C
50°C
0°C
0°C
50°C
0°C
0°C
50°C
0 mV
A thermocouple consists of two dissimilar metals. These metals
are connected at one end to form the measurement junction,
also called the hot junction. The other end of the thermocouple
is connected to the metal lines that lead to the measurement
electronics. This connection forms a second junction: the
reference junction, also called the cold junction.
AD8494/AD8495/AD8496/AD8497 ARCHITECTURE
Figure 27 shows a block diagram of the AD849x circuitry. The
AD849x consists of a low offset, fixed-gain instrumentation
amplifier and a temperature sensor.
SENSE
MEASUREMENT
JUNCTION
REFERENCE
JUNCTION
AD8494/AD8495/
AD8496/AD8497
–IN
ESD AND
OVP
PCB
TRACES
AD849x
A2
A1
1MΩ
THERMOCOUPLE WIRES
COLD JUNCTION
COMPENSATION
THERMO-
COUPLE
A3
OUT
Figure 26. Thermocouple Junctions
To derive the temperature at the measurement junction (TMJ),
the user must know the differential voltage created by the thermo-
couple. The user must also know the error voltage generated by
the temperature at the reference junction (TRJ). Compensating
for the reference junction error voltage is typically called cold
junction compensation. The electronics must compensate for
any changes in temperature at the reference (cold) junction so
that the output voltage is an accurate representation of the hot
junction measurement.
+IN
ESD AND
OVP
REF
Figure 27. Block Diagram
The AD849x output is a voltage that is proportional to the tem-
perature at the measurement junction of the thermocouple (TMJ).
To derive the measured temperature from the AD849x output
voltage, use the following transfer function:
THERMOCOUPLE SIGNAL CONDITIONER
T
MJ = (VOUT − VREF)/(5 mV/°C)
The AD8494/AD8495/AD8496/AD8497 thermocouple amplifiers
provide a simple, low cost solution for measuring thermocouple
temperatures. These amplifiers simplify many of the difficulties
of measuring thermocouples. An integrated temperature sensor
performs cold junction compensation. A fixed-gain instrumen-
tation amplifier amplifies the small thermocouple voltage to
provide a 5 mV/°C output. The high common-mode rejection
of the amplifier blocks common-mode noise that the long
thermocouple leads can pick up. For additional protection, the
high impedance inputs of the amplifier make it easy to add
extra filtering.
An ideal AD849x achieves this output with an error of less than
2°C, within the specified operating ranges listed in Table 7.
Instrumentation Amplifier
A thermocouple signal is so small that considerable gain is
required before it can be sampled properly by most ADCs. The
AD849x has an instrumentation amplifier with a fixed gain that
generates an output voltage of 5 mV/°C for J type and K type
thermocouples.
V
OUT = (TMJ × 5 mV/°C) + VREF
To accommodate the nonlinear behavior of the thermocouple,
each amplifier has a different gain so that the 5 mV/°C is accu-
rately maintained for a given temperature measurement range.
Table 6 shows an example of a J type thermocouple voltage for
various combinations of 0°C and 50°C on the reference and
measurement junctions. Table 6 also shows the performance
of the AD8494 amplifying the thermocouple voltage and
compensating for the reference junction temperature changes,
thus eliminating the error.
•
The AD8494 and AD8496 (J type) have an instrumentation
amplifier with a gain of 96.7 and 90.35, respectively.
The AD8495 and AD8497 (K type) have an instrumentation
amplifier with a gain of 122.4.
•
Rev. 0 | Page 11 of 16
AD8494/AD8495/AD8496/AD8497
The small thermocouple voltages mean that signals are quite
vulnerable to interference, especially when measured with
single-ended amplifiers. The AD849x addresses this issue in
several ways. Low input bias currents and high input impedance
allow for easy filtering at the inputs. The excellent common-mode
rejection of the AD849x prevents variations in ground potential
and other common-mode noise from affecting the measurement.
MAXIMUM ERROR CALCULATION
As is normally the case, the AD849x outputs are subject to
calibration, gain, and temperature sensitivity errors. The user
can calculate the maximum error from the AD849x using the
following information.
The five primary sources of AD849x error are described in this
section.
Temperature Sensor (Cold Junction Compensation)
AD849x Initial Calibration Accuracy
The AD849x also includes a temperature sensor for cold junc-
tion compensation. This temperature sensor is used to measure
the reference junction temperature of the thermocouple and to
cancel its effect.
Error at the initial calibration point can be easily calibrated out
with a one-point temperature calibration. See Table 2 for the
specifications.
AD849x Ambient Temperature Rejection
•
The AD8494/AD8495 cold junction compensation is
optimized for operation in a lab environment, where the
ambient temperature is around 25°C. The AD8494/AD8495
are specified for an ambient range of 0°C to 50°C.
The AD8496/AD8497 cold junction compensation is
optimized for operation in a less controlled environment,
where the temperature is around 60°C. The AD8496/AD8497
are specified for an ambient range of 25°C to 100°C.
Application examples for the AD8496/AD8497 include
automotive applications, autoclave, and ovens.
The specified ambient temperature rejection represents the
ability of the AD849x to reject errors caused by changes in the
ambient temperature/reference junction. For example, with
0.025°C/°C ambient temperature rejection, a 20°C change in the
reference junction temperature adds less than 0.5°C error to the
measurement. See Table 2 for the specifications.
•
AD849x Gain Error
Gain error is the amount of additional error when measuring away
from the measurement junction calibration point. For example,
if the part is calibrated at 25°C and the measurement junction is
100°C with a gain error of 0.1%, the gain error contribution is
(100°C − 25°C) × (0.1%) = 0.075°C. This error can be calibrated
out with a two-point calibration if needed, but it is usually small
enough to ignore. See Table 2 for the specifications.
Thermocouple Break Detection
The AD849x offers open thermocouple detection. The inputs
of the AD849x are PNP type transistors, which means that the
bias current always flows out of the inputs. Therefore, the input
bias current drives any unconnected input high, which rails the
output. Connecting the negative input to ground through a
1 Mꢀ resistor causes the AD849x output to rail high in an open
thermocouple condition (see Figure 6, Figure 28, and the
Ground Connection section).
Manufacturing Tolerances of the Thermocouple
Consult the data sheet for your thermocouple to find the
specified tolerance of the thermocouple.
Linearity Error of the Thermocouple
Each part in the AD849x family is precision trimmed to optimize
a linear operating range for a specific thermocouple type and
for the widest possible measurement and ambient temperature
ranges. The AD849x achieves a linearity error of less than 2°C,
within the specified operating ranges listed in Table 7. This error
is due only to the nonlinearity of the thermocouple.
1MΩ
Figure 28. Ground the Negative Input Through a 1 MΩ Resistor
for Open Thermocouple Detection
Input Voltage Protection
Table 7. AD849x 2°C Accuracy Temperature Ranges
The AD849x has very robust inputs. Input voltages can be up
to 25 V from the opposite supply rail. For example, with a +5 V
positive supply and a −3 V negative supply, the part can safely
withstand voltages at the inputs from −20 V to +22 V. Voltages
at the reference and sense pins should not go beyond 0.3 V of
the supply rails.
Thermo-
couple
Type
Ambient
Temperature Temperature
Measurement
Max
Error Range
Part
Range
AD8494
AD8495
AD8496
AD8497
J
K
J
2°C
2°C
2°C
2°C
0°C to 50°C
0°C to 50°C
25°C to 100°C +55°C to +565°C
25°C to 100°C −25°C to +295°C
−35°C to +95°C
−25°C to +400°C
K
For temperature ranges outside those listed in Table 7 or for
instructions on how to correct for thermocouple nonlinearity
error with software, see the product page for the AD8494,
AD8495, AD8496, or AD8497, or contact an Analog Devices
representative.
Rev. 0 | Page 12 of 16
AD8494/AD8495/AD8496/AD8497
Keeping the AD849x at the Same Temperature
as the Reference Junction
RECOMMENDATIONS FOR BEST CIRCUIT
PERFORMANCE
The AD849x compensates for thermocouple reference junction
temperature by using an internal temperature sensor. It is
critical to keep the reference junction (thermocouple-to-PCB
connection) as close to the AD849x as possible. Any difference
in temperature between the AD849x and the reference junction
appears directly as temperature error. Temperature difference
between the device and the reference junction may occur if the
AD849x is not physically close to the reference junction or if the
AD849x is required to supply large amounts of output power.
KEEP JUNCTION AND
Input Filter
A low-pass filter before the input of the AD849x is strongly
recommended (see Figure 29), especially when operating in an
electrically noisy environment. Long thermocouple leads can
function as an excellent antenna and pick up many unwanted
signals.
The filter should be set to a low corner frequency that still
allows the input signal to pass through undiminished. The
primary purpose of the filter is to remove RF signals, which,
if allowed to reach the AD849x, can be rectified and appear
as temperature fluctuations.
AD849x AT SAME
TEMPERATURE
MEASUREMENT
JUNCTION
REFERENCE
JUNCTION
PCB
AD849x
C
C
TRACES
R
R
C
C
D
KEEP
TRACES
SHORT
THERMOCOUPLE WIRES
AD849x
C
CONNECT WHEN
THERMOCOUPLE TIP
TYPE IS UNKNOWN
1MΩ
Figure 31. Compensating for Thermocouple Reference Junction Temperature
Driving the Reference Pin
1
FILTER FREQUENCY
FILTER FREQUENCY
=
DIFF
2πR(2C + C )
D
C
The AD849x comes with a reference pin, which can be used
to offset the output voltage. This is particularly useful when
reading a negative temperature in a single-supply system.
1
=
CM
2πRC
C
WHERE C ≥ 10C
C
D
Figure 29. Filter for Any Thermocouple Style
INCORRECT
CORRECT
To prevent input offset currents from affecting the measurement
accuracy, the filter resistor values should be less than 50 kΩ.
Ground Connection
AD849x
REF
AD849x
REF
V
It is always recommended that the thermocouple be connected
to ground through a 100 kΩ to 1 MΩ resistor placed at the
negative (inverting) input of the amplifier on the PCB (see
Figure 30). This solution works well regardless of the thermo-
couple tip style.
V
+
AD8613
–
Figure 32. Driving the Reference Pin
For best performance, the reference pin should be driven with a
low output impedance source, not a resistor divider. The AD8613
and the OP777 are good choices for the buffer amplifier.
1MΩ
Figure 30. Ground the Thermocouple with a 1 MΩ Resistor
Debugging Tip
If there is no electrical connection at the measurement junction
(insulated tip), the resistor value is small enough that no mean-
ingful common-mode voltage is generated. If there is an electrical
connection through a grounded or exposed tip, the resistor value
is large enough that any current from the measurement tip to
ground is very small, preventing measurement errors.
If the AD849x is not providing the expected performance, a
useful debugging step is to implement the ambient temperature
configuration in Figure 34. If the ambient temperature sensor
does not work as expected, the problem is likely with the AD849x
or with the downstream circuitry. If the ambient temperature
sensor configuration is working correctly, the problem typically
lies with how the thermocouple is connected to the AD849x.
Common errors include an incorrect grounding configuration
or lack of filtering.
The AD849x inputs require only one ground connection or source
of common-mode voltage. Any additional ground connection is
detrimental to performance because ground loops can form
through the thermocouple, easily swamping the small
thermocouple signal. Grounding the thermocouple through a
resistor as recommended prevents such problems.
Rev. 0 | Page 13 of 16
AD8494/AD8495/AD8496/AD8497
APPLICATIONS INFORMATION
BASIC CONNECTION
AMBIENT TEMPERATURE SENSOR
Figure 33 shows an example of a basic connection for the
AD849x, with a J type or K type thermocouple input.
The AD849x can be configured as a standalone Celsius thermo-
meter with a 5 mV/°C output, as shown in Figure 34. The
thermocouple sensing functionality is disabled by shorting both
AD849x inputs to ground; the AD849x simply outputs the value
from the on-board temperature sensor.
5V
0.1µF
10µF
+V
S
7
As a temperature sensor, the AD8494 has a measurement temp-
erature range of −40°C to +125°C with a precision output of
COLD JUNCTION
COMPENSATION
V
OUT = TA × 5 mV/°C
+IN
–IN
8
1
5V
+V
OUT
THERMO-
COUPLE
6
5
IN-AMP
S
7
SENSE
1MΩ
AD849x
COLD JUNCTION
COMPENSATION
2
3
–V
S
REF
+IN
–IN
0.1µF
10µF
8
1
OUT
6
5
IN-AMP
Figure 33. Basic Connection for the AD849x
SENSE
AD849x
To measure negative temperatures, apply a voltage at the refer-
ence pin to offset the output voltage at 0°C. The output voltage
of the AD849x is
2
3
–V
S
REF
Figure 34. Ambient Temperature Sensor
V
OUT = (TMJ × 5 mV/°C) + VREF
The AD8494 is the best choice for use as an ambient temper-
ature sensor. The AD8495, AD8496, and AD8497 can also be
configured as ambient temperature sensors, but their output
transfer functions are not precisely 5 mV/°C. For information
about the exact transfer functions of the AD8494/AD8495/
AD8496/AD8497, see the product page for the AD8494,
AD8495, AD8496, or AD8497, or contact an Analog Devices
representative.
A filter at the input is recommended to remove high frequency
noise. The 1 MΩ resistor to ground enables open thermocouple
detection and proper grounding of the thermocouple. The sense
pin should be connected to the output pin of the AD849x.
Decoupling capacitors should be used to ensure clean power
supply voltages on +VS and, if using dual supplies, on −VS, also.
A 0.1 ꢁF capacitor should be placed as close as possible to each
AD849x supply pin. A 10 ꢁF tantalum capacitor can be used
farther away from the part and can be shared.
The thermometer mode can be particularly useful for debugging
a misbehaving circuit. If the basic connection is not working,
disconnect the thermocouple and short both inputs to ground.
If the system reads the ambient temperature correctly, the
problem is related to the thermocouple. If the system does not
read the ambient temperature correctly, the problem is with
the AD849x or with the downstream circuitry.
Rev. 0 | Page 14 of 16
AD8494/AD8495/AD8496/AD8497
SETPOINT CONTROLLER
MEASURING NEGATIVE TEMPERATURES
The AD849x can be used as a temperature setpoint controller,
with a thermocouple input from a remote location or with the
AD849x itself being used as a temperature sensor. When the
measured temperature is below the setpoint temperature, the
output voltage goes to −VS. When the measured temperature is
above the setpoint temperature, the output voltage goes to +VS.
For best accuracy and CMRR performance, the setpoint voltage
should be created with a low impedance source. If the setpoint
voltage is generated with a voltage divider, a buffer is
recommended.
The AD849x can measure negative temperatures on dual
supplies and on a single supply. When operating on dual
supplies with the reference pin grounded, a negative output
voltage indicates a negative temperature at the thermocouple
measurement junction.
VOUT = (TMJ × 5 mV/°C) + VREF
When operating the AD849x on a single supply, level-shift
the output by applying a positive voltage (less than +VS) on
the reference pin. An output voltage less than VREF indicates
a negative temperature at the thermocouple measurement
junction.
5V
+V
S
7
REFERENCE PIN ALLOWS OFFSET ADJUSTMENT
COLD JUNCTION
COMPENSATION
The reference pin can be used to level-shift the AD849x output
voltage. This is useful for measuring negative temperatures on a
single supply and to match the AD849x output voltage range to
the input voltage range of the subsequent electronics in the
signal chain.
+IN
–IN
8
1
OUT
THERMO-
COUPLE
6
5
IN-AMP
SENSE
SETPOINT
VOLTAGE
AD849x
1MΩ
2
3
The reference pin can also be used to offset any initial calibra-
tion errors. Apply a small reference voltage proportional to the
error to nullify the effect of the calibration error on the output.
–V
S
REF
Figure 35. Setpoint Controller
Hysteresis can be added to the setpoint controller by using a
resistor divider from the output to the reference pin, as shown
in Figure 36. The hysteresis in °C is
VS R1/(R1 R2)
THYST
5mV/C
5V
+V
S
7
COLD JUNCTION
COMPENSATION
+IN
–IN
8
1
OUT
THERMO-
COUPLE
6
5
IN-AMP
R1
1kΩ
SENSE
AD849x
1MΩ
SETPOINT
VOLTAGE
2
3
–V
S
REF
R1
1kΩ
R2
100kΩ
Figure 36. Adding 10 Degrees of Hysteresis
A resistor equivalent to the output resistance of the divider should
be connected to the sense pin to ensure good CMRR.
Rev. 0 | Page 15 of 16
AD8494/AD8495/AD8496/AD8497
OUTLINE DIMENSIONS
3.20
3.00
2.80
8
5
4
5.15
4.90
4.65
3.20
3.00
2.80
1
PIN 1
IDENTIFIER
0.65 BSC
0.95
0.85
0.75
15° MAX
1.10 MAX
0.70
0.55
0.40
0.15
0.05
0.23
0.13
6°
0°
0.40
0.25
COPLANARITY
0.10
COMPLIANT TO JEDEC STANDARDS MO-187-AA
Figure 37. 8-Lead Mini Small Outline Package [MSOP]
(RM-8)
Dimensions shown in millimeters
ORDERING GUIDE
Model1, 2
AD8494ARMZ
Temperature Range
Package Description
8-Lead MSOP
Package Option
RM-8
Branding
Y36
0°C to 50°C
AD8494ARMZ-R7
AD8494CRMZ
0°C to 50°C
0°C to 50°C
8-Lead MSOP, 7”Tape and Reel
8-Lead MSOP
RM-8
RM-8
Y36
Y37
AD8494CRMZ-R7
AD8495ARMZ
0°C to 50°C
8-Lead MSOP, 7”Tape and Reel
8-Lead MSOP
RM-8
Y37
0°C to 50°C
RM-8
Y33
AD8495ARMZ-R7
AD8495CRMZ
0°C to 50°C
0°C to 50°C
8-Lead MSOP, 7”Tape and Reel
8-Lead MSOP
RM-8
RM-8
Y33
Y34
AD8495CRMZ-R7
AD8496ARMZ
AD8496ARMZ-R7
AD8496CRMZ
AD8496CRMZ-R7
AD8497ARMZ
AD8497ARMZ-R7
AD8497CRMZ
0°C to 50°C
8-Lead MSOP, 7”Tape and Reel
8-Lead MSOP
8-Lead MSOP, 7”Tape and Reel
8-Lead MSOP
8-Lead MSOP, 7”Tape and Reel
8-Lead MSOP
8-Lead MSOP, 7”Tape and Reel
8-Lead MSOP
RM-8
Y34
25°C to 100°C
25°C to 100°C
25°C to 100°C
25°C to 100°C
25°C to 100°C
25°C to 100°C
25°C to 100°C
25°C to 100°C
RM-8
RM-8
RM-8
RM-8
Y3C
Y3C
Y3D
Y3D
Y39
Y39
Y3A
Y3A
RM-8
RM-8
RM-8
RM-8
AD8497CRMZ-R7
8-Lead MSOP, 7”Tape and Reel
1 Z = RoHS Compliant Part.
2 The AD8494 and AD8496 models are prereleased.
©2010 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D08529-0-7/10(0)
Rev. 0 | Page 16 of 16
相关型号: