ADuM5020/ADuM5028
FEATURES
FUNCTIONAL BLOCK DIAGRAMS
isoPower integrated, isolated dc-to-dc converter
100 mA output current for ADuM5020
60 mA output current for ADuM5028
Meets CISPR22 Class B emissions limits at full load on a
2-layer PCB
16-lead SOIC_W package with 7.8 mm minimum creepage
8-lead SOIC_IC package with 8.3 mm minimum creepage
High temperature operation: 125°C maximum
Safety and regulatory approvals
1
2
3
4
5
6
7
8
16
NIC
NIC
ADuM5020
15 GND
GND
ISO
ISO
ISO
ISO
1
14
13
12
11
10
9
V
SEL
PDIS
PCS
GND
V
GND
1
OSC
V
RECT
REG
DDP
ISO
GND
1
GND
NIC
NIC
GND
1
GND
UL recognition (pending)
NIC = NO INTERNAL CONNECTION. LEAVE THIS PIN FLOATING.
3000 V rms for 1 minute per UL 1577
CSA Component Acceptance Notice 5A (pending)
VDE certificate of conformity (pending)
VDE V 0884-10
Figure 1. ADuM5020 Functional Block Diagram
V
IORM = 565 V peak
ADuM5028
CQC certification per GB4943.1-2011 (pending)
8
7
6
5
V
SEL
PDIS
1
2
3
4
PCS
GND
1
GND
APPLICATIONS
ISO
V
OSC
V
RECT
REG
DDP
ISO
RS-485/RS-422/CAN transceiver power
Power supply start-up bias and gate drives
Isolated sensor interfaces
GND
1
GND
ISO
Figure 2. ADuM5028 Functional Block Diagram
Industrial PLCs
GENERAL DESCRIPTION
The ADuM5020 and ADuM50281 are isoPower®, integrated,
isolated dc-to-dc converters. Based on the Analog Devices, Inc.,
iCoupler® technology, these dc-to-dc converters provide
regulated, isolated power that is below CISPR22 Class B limits at
full load on a 2-layer printed circuit board (PCB) with ferrites.
Common voltage combinations and the associated current
output levels are shown in Table 1 through Table 6.
The ADuM5020 and ADuM5028 isolated dc-to-dc converters
provide two different package variants: the ADuM5020 in a
wide body, 16-lead SOIC_W package, and the ADuM5028 in
the space saving, 8-lead, wide body SOIC_IC. For 5 V input
operations, use the ADuM5020-5BRWZ and the ADuM5028-
5BRIZ. For 3.3 V input to 3.3 V output operations, use the
ADuM5020-3BRWZ and the ADuM5028-3RIZ. See the Pin
Configuration and Function Descriptions section and the
Ordering Guide for more information.
The ADuM5020 and ADuM5028 eliminate the need to design
and build isolated dc-to-dc converters in applications up to
500 mW. The iCoupler chip scale transformer technology is used
for the magnetic components of the dc-to-dc converter. The
result is a small form factor, isolated solution.
1 Protected by U.S. Patents 5,952,849; 6,873,065; 6,903,578; and 7,075,329. Other patents are pending.
Rev. A Document Feedback
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registeredtrademarks arethe property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
©2018 Analog Devices, Inc. All rights reserved.
Technical Support
www.analog.com
ADuM5020/ADuM5028
Data Sheet
TABLE OF CONTENTS
Features .............................................................................................. 1
Recommended Operating Conditions .......................................9
Absolute Maximum Ratings ......................................................... 10
ESD Caution................................................................................ 10
Pin Configuration and Function Descriptions........................... 11
Typical Performance Characteristics ........................................... 13
Theory of Operation ...................................................................... 16
Applications Information.............................................................. 17
PCB Layout ................................................................................. 17
Thermal Analysis ....................................................................... 18
EMI Considerations................................................................... 18
Insulation Lifetime..................................................................... 18
Outline Dimensions....................................................................... 20
Ordering Guide .......................................................................... 21
Applications....................................................................................... 1
Functional Block Diagrams............................................................. 1
General Description......................................................................... 1
Revision History ............................................................................... 2
Specifications..................................................................................... 3
Electrical Characteristics—5 V Primary Input Supply/5 V
Secondary Isolated Supply .......................................................... 3
Electrical Characteristics—5 V Primary Input Supply/3.3 V
Secondary Isolated Supply .......................................................... 4
Electrical Characteristics—3.3 V Primary Input Supply/3.3 V
Secondary Isolated Supply .......................................................... 5
Regulatory Approvals................................................................... 6
Insulation and Safety Related Specifications ............................ 6
Package Characteristics ............................................................... 7
DIN V VDE V 0884-10 (VDE V 0884-10) Insulation
Characteristics .............................................................................. 7
REVISION HISTORY
12/2018—Rev. 0 to Rev. A
Change to Features Section ............................................................. 1
Change to General Description Section........................................ 1
Changes to Table 1 Table Title, Efficiency at IISO (MAX) Parameter,
Table 1, and Table 2 .......................................................................... 3
Changes to Table 3 and Table 4....................................................... 4
Added Electrical Characteristics—3.3 V Primary Input
Supply/3.3 V Secondary Isolated Supply Section, Table 5, and
Table 6; Renumbered Sequentially................................................. 5
Changes to Table 14.......................................................................... 9
Changes to Table 17, Table 18, and Table 19............................... 11
Changes to Figure 7, Figure 8, and Figure 9................................ 12
Change to Theory of Operations Section.................................... 15
Changes to Ordering Guide .......................................................... 20
6/2018—Revision 0: Initial Version
Rev. A | Page 2 of 20
Data Sheet
ADuM5020/ADuM5028
SPECIFICATIONS
ELECTRICAL CHARACTERISTICS—5 V PRIMARY INPUT SUPPLY/5 V SECONDARY ISOLATED SUPPLY
All typical specifications are at TA = 25°C, VDDP = VISO = 5 V. Minimum and maximum specifications apply over the entire recommended
operation range, which is 4.5 V ≤ VDDP ≤ 5.5 V, 4.5 V ≤ VISO ≤ 5.5 V, and −40°C ≤ TA ≤ +125°C, unless otherwise noted.
Table 1. ADuM5020-5BRIZ DC-to-DC Converter Static Specifications
Parameter
Symbol
Min Typ Max Unit
Test Conditions/Comments
DC-TO-DC CONVERTER SUPPLY
Setpoint
Line Regulation
Load Regulation1
Output Ripple1
VISO
4.75 5.0
5.25
5
V
VISO output current (IISO) = 10 mA
IISO = 50 mA, VDDP = 4.5 V to 5.5 V
IISO = 10 mA to 90 mA
VISO (LINE)
VISO (LOAD)
VISO (RIP)
2
1
75
mV/V
%
mV p-p 20 MHz bandwidth, bypass output capacitance (CBO) =
0.1 µF||10 µF, IISO = 90 mA
mV p-p CBO = 0.1 µF||10 µF, IISO = 90 mA
MHz
kHz
Output Noise1
Switching Frequency
Pulse-Width Modulation (PWM)
Frequency
Output Supply Current1
VISO (NOISE)
fOSC
fPWM
200
180
625
IISO (MAX)
50
mA
mA
%
4.75 V < VISO < 5.25 V
4.5 V < VISO < 5.25 V
IISO = 100 mA, TA = 25°C
100
33
Efficiency at IISO (MAX)
VDDP Supply Current
No VISO Load
IDDP (Q)
IDDP (MAX)
8
310
25
mA
mA
Full VISO Load
Thermal Shutdown
Shutdown Temperature
Thermal Hysteresis
154
10
°C
°C
1 Maximum VISO output current is derated by 1.75 mA/ºC for TA > 85ºC.
Table 2. ADuM5028-5BRIZ DC-to-DC Converter Static Specifications
Parameter
Symbol
Min Typ Max Unit
Test Conditions/Comments
DC-TO-DC CONVERTER SUPPLY
Setpoint
Line Regulation
Load Regulation1
Output Ripple1
Output Noise1
Switching Frequency
PWM Frequency
Output Supply Current1
Efficiency at IISO (MAX)
VDDP Supply Current
No VISO Load
VISO
4.75 5.0
5.25
5
V
IISO = 10 mA
IISO = 30 mA, VDDP = 4.5 V to 5.5 V
IISO = 6 mA to 54 mA
VISO (LINE)
VISO (LOAD)
VISO (RIP)
VISO (NOISE)
fOSC
2
1
75
mV/V
%
mV p-p 20 MHz bandwidth, CBO = 0.1 µF||10 µF, IISO = 54 mA
mV p-p CBO = 0.1 µF||10 µF, IISO = 54 mA
MHz
kHz
mA
%
200
180
625
60
fPWM
IISO (MAX)
4.75 V < VISO < 5.25 V
IISO = 60 mA, TA = 25°C
33
IDDP (Q)
IDDP (MAX)
8
190
25
mA
mA
Full VISO Load
Thermal Shutdown
Shutdown Temperature
Thermal Hysteresis
154
10
°C
°C
1 Maximum VISO output current is derated by 1 mA/ºC for TA > 85ºC.
Rev. A | Page 3 of 20
ADuM5020/ADuM5028
Data Sheet
ELECTRICAL CHARACTERISTICS—5 V PRIMARY INPUT SUPPLY/3.3 V SECONDARY ISOLATED SUPPLY
All typical specifications are at TA = 25°C, VDDP = 5.0 V, VISO = 3.3 V. Minimum/maximum specifications apply over the entire
recommended operation range, which is 4.5 V ≤ VDDP ≤ 5.5 V, 3.0 V ≤ VISO ≤ 3.6 V, and −40°C ≤ TA ≤ +125°C, unless otherwise noted.
Table 3. ADuM5020-5BRIZ DC-to-DC Converter Static Specifications
Parameter
Symbol
Min
Typ Max
Unit
Test Conditions/Comments
DC-TO-DC CONVERTER SUPPLY
Setpoint
Line Regulation
Load Regulation1
Output Ripple1
Output Noise1
Switching Frequency
PWM Frequency
Output Supply Current1
VISO
3.135 3.3
3.465
5
V
IISO = 10 mA
IISO = 50 mA, VDDP = 4.5 V to 5.5 V
IISO = 10 mA to 90 mA
VISO (LINE)
VISO (LOAD)
VISO (RIP)
VISO (NOISE)
fOSC
2
1
50
mV/V
%
mV p-p 20 MHz bandwidth, CBO = 0.1 µF||10 µF, IISO = 90 mA
mV p-p CBO = 0.1 µF||10 µF, IISO = 90 mA
130
180
625
50
100
27
MHz
kHz
mA
mA
%
fPWM
IISO (MAX)
3.135 V < VISO < 3.465 V
3.0 V < VISO < 3.465 V
IISO = 100 mA, TA = 25°C
Efficiency at IISO (MAX)
VDDP Supply Current
No VISO Load
IDDP (Q)
IDDP (MAX)
5
250
18
mA
mA
Full VISO Load
Thermal Shutdown
Shutdown Temperature
Thermal Hysteresis
154
10
°C
°C
1 Maximum VISO output current is derated by 1.75 mA/ºC for TA > 85ºC.
Table 4. ADuM5028-5BRIZ DC-to-DC Converter Static Specifications
Parameter
Symbol
Min
Typ Max
Unit
Test Conditions/Comments
DC-TO-DC CONVERTER SUPPLY
Setpoint
Line Regulation
Load Regulation1
Output Ripple1
Output Noise1
Switching Frequency
PWM Frequency
Output Supply Current1
VISO
3.135 3.3
3.465
5
V
IISO = 10 mA
IISO = 30 mA, VDDP = 4.5 V to 5.5 V
IISO = 6 mA to 54 mA
VISO (LINE)
VISO (LOAD)
VISO (RIP)
VISO (NOISE)
fOSC
2
1
50
mV/V
%
mV p-p 20 MHz bandwidth, CBO = 0.1 µF||10 µF, IISO = 54 mA
mV p-p CBO = 0.1 µF||10 µF, IISO = 54 mA
130
180
625
30
MHz
kHz
mA
mA
%
fPWM
IISO (MAX)
3.135 V < VISO < 3.465 V
3.0 V < VISO < 3.465 V
IISO = 60 mA, TA = 25°C
60
Efficiency at IISO (MAX)
VDDP Supply Current
No VISO Load
27
IDDP (Q)
IDDP (MAX)
5
150
18
mA
mA
Full VISO Load
Thermal Shutdown
Shutdown Temperature
Thermal Hysteresis
154
10
°C
°C
1 Maximum VISO output current is derated by 1 mA/ºC for TA > 85ºC.
Rev. A | Page 4 of 20
Data Sheet
ADuM5020/ADuM5028
ELECTRICAL CHARACTERISTICS—3.3 V PRIMARY INPUT SUPPLY/3.3 V SECONDARY ISOLATED SUPPLY
All typical specifications are at TA = 25°C, VDDP = 3.3 V, VISO = 3.3 V. Minimum/maximum specifications apply over the entire
recommended operation range, which is 3.0 V ≤ VDDP ≤ 3.6 V, 3.0 V ≤ VISO ≤ 3.6 V, and −40°C ≤ TA ≤ +125°C, unless otherwise noted.
Table 5. ADuM5020-3BRWZ DC-to-DC Converter Static Specifications
Parameter
Symbol
Min
Typ Max
Unit
Test Conditions/Comments
DC-TO-DC CONVERTER SUPPLY
Setpoint
Line Regulation
Load Regulation1
Output Ripple1
Output Noise1
Switching Frequency
PWM Frequency
Output Supply Current1
VISO
3.135 3.3
3.465
5
V
IISO = 10 mA
IISO = 50 mA, VDDP = 3.0 V to 3.6 V
IISO = 7 mA to 63 mA
VISO (LINE)
VISO (LOAD)
VISO (RIP)
VISO (NOISE)
fOSC
2
1
50
mV/V
%
mV p-p 20 MHz bandwidth, CBO = 0.1 µF||10 µF, IISO = 90 mA
mV p-p CBO = 0.1 µF||10 µF, IISO = 90 mA
130
180
625
35
MHz
kHz
mA
mA
%
fPWM
IISO (MAX)
3.135 V < VISO < 3.465 V
3.0 V < VISO < 3.465 V
IISO = 70 mA, TA = 25°C
70
Efficiency at IISO (MAX)
VDDP Supply Current
No VISO Load
33
IDDP (Q)
IDDP (MAX)
5
225
15
mA
mA
Full VISO Load
Thermal Shutdown
Shutdown Temperature
Thermal Hysteresis
154
10
°C
°C
1 Maximum VISO output current is derated by 2 mA/°C for TA > 105°C.
Table 6. ADuM5028-3BRIZ DC-to-DC Converter Static Specifications
Parameter
Symbol
Min
Typ Max
Unit
Test Conditions/Comments
DC-TO-DC CONVERTER SUPPLY
Setpoint
Line Regulation
Load Regulation1
Output Ripple1
Output Noise1
Switching Frequency
PWM Frequency
Output Supply Current1
VISO
3.135 3.3
3.465
5
V
IISO = 10 mA
IISO = 30 mA, VDDP = 3.0 V to 3.6 V
IISO = 6 mA to 54 mA
VISO (LINE)
VISO (LOAD)
VISO (RIP)
VISO (NOISE)
fOSC
2
1
50
mV/V
%
mV p-p 20 MHz bandwidth, CBO = 0.1 µF||10 µF, IISO = 54 mA
mV p-p CBO = 0.1 µF||10 µF, IISO = 54 mA
130
180
625
30
MHz
kHz
mA
mA
%
fPWM
IISO (MAX)
3.135 V < VISO < 3.465 V
3.0 V < VISO < 3.465 V
IISO = 60 mA, TA = 25°C
60
Efficiency at IISO (MAX)
VDDP Supply Current
No VISO Load
33
IDDP (Q)
IDDP (MAX)
5
190
15
mA
mA
Full VISO Load
Thermal Shutdown
Shutdown Temperature
Thermal Hysteresis
154
10
°C
°C
1 Maximum VISO output current is derated by 2 mA/°C for TA > 105°C.
Rev. A | Page 5 of 20
ADuM5020/ADuM5028
Data Sheet
REGULATORY APPROVALS
Table 7.
UL (Pending)1
CSA (Pending)
VDE (Pending)2
CQC (Pending)
Recognized Under 1577 Component Approved under CSA Component
DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
Certified under
CQC11-471543-2012
Recognition Program1
Acceptance Notice 5A
Single Protection, 3000 V rms
Isolation Voltage
CSA 60950-1-07+A1+A2 and
IEC 60950-1, second edition, +A1+A2
Reinforced insulation
565 V peak, surge isolation
voltage (VIOSM) =
GB4943.1-2011:
Basic insulation at 780 V rms
(1103 V peak)
6000 V peak
Basic insulation at 780 V rms
(1103 V peak)
Transient voltage (VIOTM) =
4242 V peak
Reinforced insulation at
390 V rms (552 V peak)
Reinforced insulation at 390 V rms
(552 V peak)
IEC 60601-1 Edition 3.1:
Basic insulation (1 means of patient
protection (1 MOPP)), 585 V rms
(827 V peak)
CSA 61010-1-12 and IEC 61010-1 third
edition:
Basic insulation at 300 V rms mains,
780 V rms (1103 V peak)
Reinforced insulation at 300 V rms
mains, 390 V rms (552 V peak)
File E214100
File 205078
File 2471900-4880-0001
File (pending)
1 In accordance with UL 1577, each ADuM5020 and ADuM5028 are proof tested by applying an insulation test voltage ≥ 3600 V rms for 1 sec.
2 In accordance with DIN V VDE V 0884-10, each ADuM5020 and ADuM5028 are proof tested by applying an insulation test voltage ≥ 1059 V peak for 1 sec (partial
discharge detection limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
INSULATION AND SAFETY RELATED SPECIFICATIONS
For additional information, see www.analog.com/icouplersafety.
Table 8. ADuM5020 Insulation and Safety
Parameter
Symbol Value Unit
Test Conditions/Comments
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
3000
7.8
V rms
1-minute duration
L (I01)
L (I02)
L (PCB)
mm min Measured from input terminals to output terminals,
shortest distance through air
mm min Measured from input terminals to output terminals,
shortest distance path along body
mm min Measured from input terminals to output terminals,
shortest distance through air, line of sight, in the PCB
mounting plane
Minimum External Tracking (Creepage)
7.8
8.3
Minimum Clearance in the Plane of the Printed
Circuit Board (PCB Clearance)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Material Group
25.5
>600
I
μm min
V
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
CTI
Table 9. ADuM5028 Insulation and Safety
Parameter
Symbol Value Unit
Test Conditions/Comments
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
3000
8.3
V rms
1-minute duration
L (I01)
L (I02)
L (PCB)
mm min Measured from input terminals to output terminals,
shortest distance through air
mm min Measured from input terminals to output terminals,
shortest distance path along body
mm min Measured from input terminals to output terminals,
shortest distance through air, line of sight, in the PCB
mounting plane
Minimum External Tracking (Creepage)
8.3
8.3
Minimum Clearance in the Plane of the Printed
Circuit Board (PCB Clearance)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Material Group
25.5
>600
I
μm min
V
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
CTI
Rev. A | Page 6 of 20
Data Sheet
ADuM5020/ADuM5028
PACKAGE CHARACTERISTICS
Table 10. ADuM5020 Package Characteristics
Parameter
Symbol Min Typ
Max Unit Test Conditions/Comments
Resistance (Input to Output)1
Capacitance (Input to Output)1
Input Capacitance2
RI-O
CI-O
CI
1013
2.2
4.0
45
Ω
pF
pF
f = 1 MHz
IC Junction to Ambient Thermal
Resistance
θJA
°C/W Thermocouple located at center of package
underside3
1 This device is considered a 2-terminal device: Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
2 Input capacitance is from any input data pin to ground.
3 The value of θJA is based on devices mounted on a JEDEC JESD-51 standard 2s2p board and still air.
Table 11. ADuM5028 Package Characteristics
Parameter
Symbol Min Typ
Max Unit Test Conditions/Comments
Resistance (Input to Output)1
Capacitance (Input to Output)1
Input Capacitance2
RI-O
CI-O
CI
1013
2.2
4.0
80
Ω
pF
pF
f = 1 MHz
IC Junction to Ambient Thermal
Resistance
θJA
°C/W Thermocouple located at center of package
underside3
1 This device is considered a 2-terminal device: Pin 1 through Pin 4 are shorted together, and Pin 5 through Pin 8 are shorted together.
2 Input capacitance is from any input data pin to ground.
3 The value of θJA is based on devices mounted on a JEDEC JESD-51 standard 2s2p board and still air.
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
the protective circuits. The asterisk (*) marking on packages denotes DIN V VDE V 0884-10 approval.
Table 12. ADuM5020 VDE Characteristics
Description
Test Conditions/Comments
Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
Climatic Classification
Pollution Degree per DIN VDE 0110, Table 1
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b1
I to IV
I to III
I to II
40/125/21
2
VIORM
VPR
565
1059
V peak
V peak
V
IORM × 1.875 = VPR, 100% production test, tm = 1 sec,
partial discharge < 5 pC
Input to Output Test Voltage, Method a
After Environmental Tests Subgroup 1
VPR
Vpd(m)
V
IORM × 1.5 = Vpd(m), tini = 60 sec, tm = 10 sec,
848
678
V peak
V peak
partial discharge < 5 pC
VIORM × 1.2 = Vpd(m), tini = 60 sec, tm = 10 sec,
partial discharge < 5 pC
After Input or Safety Test Subgroup 2
and Subgroup 3
Vpd(m)
Highest Allowable Overvoltage
Withstand Isolation Voltage
Surge Isolation Voltage Reinforced
Safety Limiting Values
Transient overvoltage, tTR = 10 sec
1 minute withstand rating
VIOSM(TEST) = 10 kV; 1.2 µs rise time; 50 µs, 50% fall time VIOSM
Maximum value allowed in the event of a failure
(see Figure 3)
VIOTM
VISO
4242
3000
6000
V peak
V rms
V peak
Case Temperature
Total Power Dissipation at 25°C
Insulation Resistance at TS
TS
IS1
RS
150
2.78
>109
°C
W
Ω
VIO = 500 V
Rev. A | Page 7 of 20
ADuM5020/ADuM5028
Data Sheet
Table 13. ADuM5028 VDE Characteristics
Description
Test Conditions/Comments
Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
Climatic Classification
Pollution Degree per DIN VDE 0110, Table 1
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b1
I to IV
I to III
I to II
40/125/21
2
VIORM
VPR
565
1059
V peak
V peak
VIORM × 1.875 = VPR, 100% production test, tm = 1 sec,
partial discharge < 5 pC
Input to Output Test Voltage, Method a
After Environmental Tests Subgroup 1
VPR
Vpd(m)
V
IORM × 1.5 = Vpd(m), tini = 60 sec, tm = 10 sec,
848
678
V peak
V peak
partial discharge < 5 pC
VIORM × 1.2 = Vpd(m), tini = 60 sec, tm = 10 sec,
partial discharge < 5 pC
After Input and/or Safety Test Subgroup 2
and Subgroup 3
Vpd(m)
Highest Allowable Overvoltage
Withstand Isolation Voltage
Surge Isolation Voltage Reinforced
Safety Limiting Values
Transient overvoltage, tTR = 10 sec
1 minute withstand rating
VIOSM(TEST) = 10 kV; 1.2 µs rise time; 50 µs, 50% fall time VIOSM
Maximum value allowed in the event of a failure
(see Figure 4)
VIOTM
VISO
4242
3000
6000
V peak
V rms
V peak
Case Temperature
Total Power Dissipation at 25°C
Insulation Resistance at TS
TS
IS1
RS
150
1.56
>109
°C
W
Ω
VIO = 500 V
Rev. A | Page 8 of 20
Data Sheet
ADuM5020/ADuM5028
3.0
2.5
2.0
1.5
1.0
0.5
RECOMMENDED OPERATING CONDITIONS
Table 14.
Parameter
Symbol Min Typ Max Unit
Operating Temperature1
Supply Voltages2
TA
VDDP
−40
+125 °C
ADuM5020-5BRWZ,
ADuM5028-5BRIZ,
VDDP at VISO = 3.135 V
to 3.465 V
ADuM5020-3BRWZ,
ADuM5028-3BRIZ,
VDDP at VISO = 3.135 V
to 3.465 V
4.5
5.5
3.6
5.5
V
V
V
3.0
4.5
0
0
50
100
150
200
AMBIENT TEMPERATURE (°C)
ADuM5020-5BRWZ,
ADuM5028-5BRIZ,
Figure 3. ADuM5020 Thermal Derating Curve, Dependence of Safety Limiting
Values with Ambient Temperature per DIN V VDE V 0884-10
VDDP at VISO = 4.75 V
to 5.25 V
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
1 Operation at >85°C requires reduction of the maximum load current.
2 Each voltage is relative to its respective ground.
0
50
100
150
200
AMBIENT TEMPERATURE (°C)
Figure 4. ADuM5028 Thermal Derating Curve, Dependence of Safety Limiting
Values with Ambient Temperature per DIN V VDE V 0884-10
Rev. A | Page 9 of 20
ADuM5020/ADuM5028
Data Sheet
ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted.
Table 16. Maximum Continuous Working Voltage
Supporting 50-Year Minimum Lifetime1
Table 15.
Applicable
Certification
Parameter
Rating
Parameter
Max Unit
Storage Temperature (TST)
−55°C to +150°C
AC Voltage
Ambient Operating Temperature (TA) −40°C to +125°C
Bipolar Waveform
Unipolar Waveform
Basic Insulation
DC Voltage
560
560
V peak 50-year operation
V peak 50-year operation
1
Supply Voltages (VDDP, VISO
VISO Supply Current
ADuM5020
)
−0.5 V to +7.0 V
100 mA
ADuM5028
60 mA
−0.5 V to VDDI + 0.5 V
−200 kV/µs to +200 kV/µs
Basic Insulation
1000 V peak 50-year operation
Input Voltage (PDIS, VSEL)1, 2
1 Maximum continuous working voltage refers to the continuous voltage
magnitude imposed across the isolation barrier. See the Insulation Lifetime
section for more information.
Common-Mode Transients3
1 All voltages are relative to their respective ground.
2 VDDI is the input side supply voltage.
3 Common-mode transients refer to common-mode transients across the
insulation barrier. Common-mode transients exceeding the absolute
maximum ratings may cause latch-up or permanent damage.
ESD CAUTION
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
Rev. A | Page 10 of 20
Data Sheet
ADuM5020/ADuM5028
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
NIC
NIC
GND
GND
1
ISO
ISO
ISO
ISO
V
PDIS
SEL
ADuM5020
GND
1
GND
TOP VIEW
V
V
DDP
ISO
(Not to Scale)
GND
1
GND
NIC
NIC
GND
GND
1
NIC = NO INTERNAL CONNECTION.
LEAVE THESE PINS FLOATING.
Figure 5. Pin Configuration
Table 17. ADuM5020 Pin Function Descriptions
Pin No. Mnemonic Description
1, 7, 10, 16 NIC No Internal Connection. Leave these pins floating.
2, 4, 6, 8
3
GND1
PDIS
Ground 1. Ground reference for the primary. It is recommended that these pins be connected to a common ground.
Power Disable. When tied to any GND1 pin, the VISO output voltage is active. When a logic high voltage is applied,
the VISO output voltage is shut down. Do not leave this pin floating.
5
VDDP
Primary Supply Voltage.
9, 11, 13, 15 GNDISO
Ground Reference for VISO on Side 2. It is recommended that these pins be connected to a common ground.
Secondary Supply Voltage Output for External Loads.
Output Voltage Selection. Connect VSEL to VISO for 5 V output or connect VSEL to GNDISO for 3.3 V output. This pin has a
weak internal pull-up. Therefore, do not leave this pin floating. It is recommended that the ADuM5020-3BRWZ and
12
14
VISO
VSEL
the ADuM5028-3BRIZ are only used for 3.3 V input to 3.3 V operation, therefore connect VSEL to GNDISO
.
V
1
2
3
4
8
7
6
5
PDIS
SEL
ADuM5028
GND
1
GND
ISO
TOP VIEW
V
V
DDP
ISO
(Not to Scale)
GND
1
GND
ISO
Figure 6. ADuM5028 Pin Configuration
Table 18. ADuM5028 Pin Function Descriptions
Pin No. Mnemonic Description
1
PDIS
Power Disable. When tied to any GND1 pin, the VISO output voltage is active. When a logic high voltage is applied, the
ISO output voltage is shut down. Do not leave this pin floating.
V
2, 4
3
GND1
VDDP
Ground 1. Ground reference for the primary. It is recommended that these pins be connected to a common ground.
Primary Supply Voltage.
5, 7
6
GNDISO
VISO
Ground Reference for VISO on Side 2. It is recommended that these pins be connected together.
Secondary Supply Voltage Output for External Loads.
8
VSEL
Output Voltage Selection. Connect VSEL to VISO for 5 V output or connect VSEL to GNDISO for 3.3 V output. This pin has a
weak internal pull-up; therefore, do not leave this pin floating. It is recommended that the ADuM5020-3BRWZ and the
ADuM5028-3BRIZ are only used for 3.3 V input to 3.3 V operation, therefore connect VSEL to GNDISO
.
Table 19. Truth Table (Positive Logic)
VDDP (V)
VSEL Input
PDIS Input
Low
VISO Output (V)
Notes
5
High
5
5
5
3.3
3.3
3.3
Low
Don’t care
Low
High
Don’t care
Low
High
Low
Low
3.3
0
3.3
5
Configuration not recommended
High
0
Rev. A | Page 11 of 21
ADuM5020/ADuM5028
Data Sheet
TYPICAL PERFORMANCE CHARACTERISTICS
35
5.10
5.08
5.06
5.04
5.02
5.00
4.98
4.96
30
25
20
15
10
3.3V IN/3.3V OUT
5V IN/5V OUT
5V IN/3.3V OUT
5
0
0
0.02
0.04
0.06
0.08
0.10
0
0.02
0.04
0.06
0.08
0.10
I
OUTPUT CURRENT (A)
I
OUTPUT CURRENT (A)
ISO
ISO
Figure 7. Typical Power Supply Efficiency in Supported Supply Configurations
Figure 10. VISO vs. IISO Output Current, Input = 5 V, VISO = 5 V
0.10
0.09
0.08
0.07
0.06
0.05
0.04
0.03
3.36
3.34
3.32
3.30
3.28
3.26
3.24
3.22
0.02
3.3V IN/3.3V OUT
5V IN/5V OUT
5V IN/3.3V OUT
0.01
0
0
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0
0.02
0.04
0.06
0.08
0.10
INPUT CURRENT (A)
I
OUTPUT CURRENT (A)
ISO
Figure 8. IISO Output Current vs. Input Current in Supported Power
Configurations
Figure 11. VISO vs. IISO Output Current, Input = 5 V,
VISO = 3.3 V
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
5.10
5.08
5.06
5.04
5.02
5.00
4.98
4.96
0.2
3.3V IN/3.3V OUT
5V IN/5V OUT
5V IN/3.3V OUT
0.1
0
0
0.02
0.04
0.06
0.08
0.10
–50
–25
0
25
50
75
100
125
I
OUTPUT CURRENT (A)
ISO
TEMPERATURE (°C)
Figure 9. Total Power Dissipation vs. IISO Output Current in Supported Power
Configurations
Figure 12. VISO vs. Temperature, Input = 5 V, VISO Output = 5 V
Rev. A | Page 12 of 20
Data Sheet
ADuM5020/ADuM5028
3.32
3.30
3.28
3.26
3.24
3.22
3.20
3.18
3.0
2.5
2.0
1.5
1.0
0.5
0
POWER DISSIPATION
DD1
I
–50
–25
0
25
50
75
100
125
3.5
4.0
4.5
5.0
5.5
TEMPERATURE (°C)
V
(V)
DDP
Figure 13. VISO vs. Temperature, Input = 3.3 V, VISO Output = 3.3 V
Figure 16. Short-Circuit Input Current (IDD1) and Power Dissipation vs. VDDP
15
10
5
1,000
V
AT 5V (mV)
ISO
PERCENT LOAD
500
0
0
–500
–1,000
–5
–10
–15
100
50
0
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
1.0
2.0
3.0
4.0
5.0
6.0
TIME (µs)
TIME (ms)
Figure 14. VISO Ripple, 5 V Input to 5 V Output at 90% Load,
Bandwidth = 20 MHz
Figure 17. VISO Transient Load Response 5 V Input to 5 V Output 10% to 90%
Load Step
15
10
5
1,000
VISO AT 3.3V (mV)
PERCENT LOAD
500
0
0
–500
–5
–10
–15
100
50
0
–1,000
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
–1.0
0
1.0
2.0
3.0
4.0
TIME (µs)
TIME (ms)
Figure 15. VISO Ripple, 5 V Input to 3.3 V Output at 90% Load,
Bandwidth = 20 MHz
Figure 18. VISO Transient Load Response 5 V Input to 3.3 V Output, 10% to
90% Load Step
Rev. A | Page 13 of 20
ADuM5020/ADuM5028
Data Sheet
7
5
4
V
V
AT 10% LOAD (V)
AT 90% LOAD (V)
V
V
AT 10% LOAD (V)
AT 90% LOAD (V)
ISO
ISO
ISO
ISO
6
5
3
4
3
2
2
1
1
0
0
–1
–1
0
1
2
3
4
0
1
2
3
4
TIME (ms)
TIME (ms)
Figure 19. 5 V Input to 5 V Output VISO Start-Up Transient at 10% and 90%
Load
Figure 20. 5 V Input to 3.3 V Output VISO Start-Up Transient at 10% and 90%
Load
Rev. A | Page 14 of 20
Data Sheet
ADuM5020/ADuM5028
THEORY OF OPERATION
The ADuM5020/ADuM5028 dc-to-dc work on principles that
are common to most standard power supplies. The converters
have a split controller architecture with isolated PWM feedback.
VDDP power is supplied to an oscillating circuit that switches
current into a chip scale air core transformer. Power transferred to
the secondary side is rectified and regulated to 3.3 V or 5.0 V,
depending on the setting of the VSEL pin. Note that the
ADuM5020-3BRWZ and the ADuM5028-3BRIZ can only be
used for 3.3 V input to 3.3 V output applications, and the
ADuM5020-5BRWZ and ADuM5028-5BRIZ operate best for
5 V input applications. The secondary (VISO) side controller
regulates the output by creating a PWM control signal that is sent
to the primary (VDDP) side by a dedicated iCoupler data
channel. The PWM modulates the oscillator circuit to control the
power being sent to the secondary side. Feedback allows
significantly higher power and efficiency.
The ADuM5020/ADuM5028 implement undervoltage lockout
(UVLO) with hysteresis on the primary and secondary side input
and output pins as well as the VDDP power input. The UVLO
feature ensures that the converters do not go into oscillation due
to noisy input power or slow power-on ramp rates.
Rev. A | Page 15 of 20
ADuM5020/ADuM5028
Data Sheet
APPLICATIONS INFORMATION
for several operating frequencies. Noise suppression requires a
low inductance, high frequency capacitor, whereas ripple
suppression and proper regulation require a large value capacitor.
These capacitors are most conveniently connected between the
PCB LAYOUT
The ADuM5020 and ADuM5028 isoPower integrated dc-to-dc
converters require power supply bypassing at the input and
output supply pins (see Figure 21 and Figure 22). Low effective
series resistance (ESR) 0.1 μF bypass capacitors are required
between the VDDP pin and GND1 pin, as close to the chip pads
as possible. Low ESR 0.1 μF or 0.22 μF capacitors are required
between the VISO pin and GNDISO pin, as close to the chip pads
as possible (see the CISO note in Figure 23 and Figure 24 for
more information). The isoPower inputs require multiple
passive components to bypass the power effectively, as well as
set the output voltage and bypass the core voltage regulator (see
Figure 21 through Figure 26).
VDDP pin and GND1 pin, and between the VISO pin and GNDISO pin.
To suppress noise and reduce ripple, a parallel combination of at
least two capacitors is required. The recommended capacitor values
are 0.1 μF and 10 μF for VDDP and VISO. The smaller capacitor
must have a low ESR. For example, use of a ceramic capacitor is
advised. The total lead length between the ends of the 0.1 μF low
ESR capacitors, and the power supply pins must not exceed 2 mm.
To reduce the level of electromagnetic radiation, the impedance
to high frequency currents between the VISO and GNDISO pins and
the PCB trace connections can be increased. Using this method
of electromagnetic interference (EMI) suppression controls the
radiating signal at its source by placing surface-mount ferrite beads
in series with the VISO and GNDISO pins, as shown in Figure 25
and Figure 26. The impedance of the ferrite bead is chosen to be
about 1.8 kΩ between the 100 MHz and 1 GHz frequency range to
reduce the emissions at the 180 MHz primary switching frequency
and the 360 MHz secondary side rectifying frequency and
harmonics. See Table 20 for examples of appropriate surface-
mount ferrite beads.
PDIS
3
GND
1
4
5
6
V
DDP
GND
1
10µF
0.1µF
Figure 21. ADuM5020 VDDP Bias and Bypass Components
PDIS
1
GND
1
2
3
4
Table 20. Surface-Mount Ferrite Beads Example
V
DDP
Manufacturer
Part No.
GND
1
10µF
0.1µF
Taiyo Yuden
Murata Electronics
BKH1005LM182-T
BLM15HD182SN1
Figure 22. ADuM5028 VDDP Bias and Bypass Components
ADuM5020
V
SEL
14
13
12
11
NIC
NIC
GND
ISO
ISO
GND
GND
ISO
1
FB1
V
V
PDIS
GND
ISO
SEL
VISO OUT
GND
V
1
ISO
ISO
GND
C
10µF
ISO
V
V
OUT
DDP
ISO
FB2
GND
NIC
GND
1
1
ISO
10µF 0.1µF
C
FERRITES 10µF
ISO
NIC
GND
GND
ISO
C
C
= 0.1µF FOR V
= 0.22µF FOR V
= 5V AND V
= 5V,
ISO
ISO
DDP
ISO
= 5V AND V
= 3.3V
ISO
DDP
BYPASS <2mm
= 0.1µF FOR V = 5V AND V = 5V,
ISO
Figure 23. ADuM5020 VISO Bias and Bypass Components
C
C
ISO
ISO
DDP
= 0.22µF FOR V
= 5V AND V
= 3.3V
DDP
ISO
V
SEL
8
7
6
5
Figure 25. Recommended ADuM5020 PCB Layout
GND
ISO
ISO
ADuM5028
FB1
V
ISO
VISO OUT
V
PDIS
GND
SEL
GND
C
10µF
FB2
ISO
GND
1
ISO
ISO
V
V
VISO OUT
DDP
GND
GND
1
ISO
10µF 0.1µF
C
FERRITES 10µF
ISO
C
C
= 0.1µF FOR V
= 0.22µF FOR V
= 5V AND V
= 5V,
ISO
ISO
ISO
DDP
BYPASS <2mm
= 0.1µF FOR V = 5V AND V = 5V,
ISO
= 5V AND V
= 3.3V
DDP
ISO
C
C
ISO
ISO
DDP
Figure 24. ADuM5028 VISO Bias and Bypass Components
= 0.22µF FOR V
= 5V AND V
= 3.3V
DDP
ISO
The power supply section of the ADuM5020 and ADuM5028
uses a 180 MHz oscillator frequency to efficiently pass power
through its chip scale transformers. Bypass capacitors are required
Figure 26. Recommended ADuM5028 PCB Layout
Rev. A | Page 16 of 21
Data Sheet
ADuM5020/ADuM5028
In applications involving high common-mode transients, ensure
that board coupling across the isolation barrier is minimized.
Furthermore, design the board layout such that any coupling
that does occur equally affects all pins on a given component
side. Failure to ensure these steps can cause voltage differentials
between pins, exceeding the absolute maximum ratings specified in
Table 15, thereby leading to latch-up or permanent damage.
surface insulation of components that allows the components to be
categorized in different material groups. Lower material group
ratings are more resistant to surface tracking and, therefore, can
provide adequate lifetime with smaller creepage. The minimum
creepage for a given working voltage and material group is in
each system level standard and is based on the total rms voltage
across the isolation, pollution degree, and material group. The
material group and creepage for the ADuM5020 and ADuM5028
are presented in Table 8 and Table 9.
THERMAL ANALYSIS
The ADuM5020 and ADuM5028 each consist of three internal
die attached to a split lead frame. For thermal analysis, the die is
treated as a thermal unit, with the highest junction temperature
reflected in the θJA values, shown in Table 10 and Table 11. The
value of θJA is based on measurements taken with the devices
mounted on a JEDEC standard, 4-layer board with fine width
traces and still air. Under normal operating conditions, the
ADuM5020 and ADuM5028 can operate at full load, but at
temperatures greater than 85°C, derating the output current
may be needed, as shown in Figure 3 and Figure 4.
Insulation Wear Out
The lifetime of insulation caused by wear out is determined by
its thickness, material properties, and the voltage stress applied.
It is important to verify that the product lifetime is adequate at
the application working voltage. The working voltage supported
by an isolator for wear out may not be the same as the working
voltage supported for tracking. The working voltage applicable
to tracking is specified in most standards.
Testing and modeling show that the primary driver of long-term
degradation is displacement current in the polyimide insulation
causing incremental damage. The stress on the insulation can be
grouped into broad categories, such as dc stress, which causes very
little wear out because there is no displacement current, and an
ac component time varying voltage stress, which causes wear out.
EMI CONSIDERATIONS
The ADuM5020/ADuM5028 dc-to-dc converters must, of
necessity, operate at a high frequency to allow efficient power
transfer through the small transformers. This high frequency
operation creates high frequency currents that can propagate in
circuit board ground and power planes, requiring proper power
supply bypassing at the input and output supply pins
The ratings in certification documents are usually based on a
60 Hz sinusoidal waveform because this stress reflects isolation
from line voltage. However, many practical applications have
combinations of 60 Hz ac and dc across the barrier as shown in
Equation 1. Because only the ac portion of the stress causes
wear out, the equation can be rearranged to solve for the ac rms
voltage, as shown in Equation 2. For insulation wear out with the
polyimide materials used in these products, the ac rms voltage
determines the product lifetime.
(see Figure 25 and Figure 26). Using proper layout, bypassing
techniques, and surface-mount ferrite beads in series with the
VISO and GNDISO pins, the dc-to-dc converters are designed to
provide regulated, isolated power that is below CISPR22 Class B
limits at full load on a 2-layer PCB with ferrites.
INSULATION LIFETIME
All insulation structures eventually break down when subjected to
voltage stress over a sufficiently long period. The rate of insulation
degradation is dependent on the characteristics of the voltage
waveform applied across the insulation, as well as on the materials
and material interfaces.
2
V
RMS VAC RMS2 VDC
(1)
or
2
V
AC RMS VRMS2 VDC
(2)
where:
The two types of insulation degradation of primary interest are
breakdown along surfaces exposed to the air and insulation wear
out. Surface breakdown is the phenomenon of surface tracking
and the primary determinant of surface creepage requirements
in system level standards. Insulation wear out is the phenomenon
where charge injection or displacement currents inside the
insulation material cause long-term insulation degradation.
V
V
V
RMS is the total rms working voltage.
AC RMS is the time varying portion of the working voltage.
DC is the dc offset of the working voltage.
Calculation and Use of Parameters Example
The following example frequently arises in power conversion
applications. Assume that the line voltage on one side of the
Surface Tracking
isolation is 240 V ac rms and a 400 V dc bus voltage is present
on the other side of the isolation barrier. The isolator material is
polyimide. To establish the critical voltages in determining the
creepage, clearance, and lifetime of a device, see Figure 27 and
the following equations.
Surface tracking is addressed in electrical safety standards by
setting a minimum surface creepage based on the working voltage,
the environmental conditions, and the properties of the insulation
material. Safety agencies perform characterization testing on the
Rev. A | Page 17 of 21
ADuM5020/ADuM5028
Data Sheet
To determine if the lifetime is adequate, obtain the time varying
portion of the working voltage. To obtain the ac rms voltage,
use Equation 2.
V
AC RMS
VAC RMS = VRMS2 −VDC
2
V
V
V
DC
=
4662 − 4002
PEAK
RMS
VAC RMS
AC RMS = 240 V rms
V
In this case, the ac rms voltage is simply the line voltage of
240 V rms. This calculation is more relevant when the waveform is
not sinusoidal. The value is compared to the limits for working
voltage in Table 16 for the expected lifetime, which is less than a
60 Hz sine wave, and it is well within the limit for a 50-year
service life.
TIME
Figure 27. Critical Voltage Example
The working voltage across the barrier from Equation 1 is
2
VRMS = VAC RMS2 +VDC
Note that the dc working voltage limit is set by the creepage of
the package as specified in IEC 60664-1. This value can differ
for specific system level standards.
VRMS = 2402 + 4002
V
RMS = 466 V
This VRMS value is the working voltage used together with the
material group and pollution degree when looking up the creepage
required by a system standard.
Rev. A | Page 18 of 20
Data Sheet
ADuM5020/ADuM5028
OUTLINE DIMENSIONS
10.50 (0.4134)
10.10 (0.3976)
16
1
9
8
7.60 (0.2992)
7.40 (0.2913)
10.65 (0.4193)
10.00 (0.3937)
0.75 (0.0295)
0.25 (0.0098)
1.27 (0.0500)
BSC
45°
2.65 (0.1043)
2.35 (0.0925)
0.30 (0.0118)
0.10 (0.0039)
8°
0°
COPLANARITY
0.10
SEATING
PLANE
0.51 (0.0201)
0.31 (0.0122)
1.27 (0.0500)
0.40 (0.0157)
0.33 (0.0130)
0.20 (0.0079)
COMPLIANT TO JEDEC STANDARDS MS-013-AA
CONTROLLING DIMENSIONS ARE IN MILLIMETERS; INCH DIMENSIONS
(IN PARENTHESES) ARE ROUNDED-OFF MILLIMETER EQUIVALENTS FOR
REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN.
Figure 28. 16-Lead Standard Small Outline Package [SOIC_W]
Wide Body (RW-16)
Dimensions shown in millimeters and (inches)
6.05
5.85
5.65
8
1
5
4
7.60
7.50
7.40
10.51
10.31
10.11
PIN 1
MARK
0.75
0.50 45°
0.25
2.45
2.35
2.25
2.65
2.50
2.35
1.04
BSC
8°
0°
0.30
0.33
0.27
0.20
SEATING
PLANE
0.20
0.10
COPLANARITY
0.10
0.51
0.41
0.31
1.27 BSC
0.75
0.58
0.40
Figure 29. 8-Lead Standard Small Outline Package, with Increased Creepage [SOIC_IC]
Wide Body
(RI-8-1)
Dimensions shown in millimeters
Rev. A | Page 19 of 20
ADuM5020/ADuM5028
Data Sheet
ORDERING GUIDE
Model1, 2, 3, 4
Typical VDDP Voltage (V)
Temperature Range
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
Package Description
16-Lead SOIC_W
16-Lead SOIC_W
16-Lead SOIC_W
16-Lead SOIC_W
Package Option
RW-16
RW-16
RW-16
RW-16
ADuM5020-5BRWZ
ADuM5020-5BRWZ-RL
ADuM5020-3BRWZ
ADuM5020-3BRWZ-RL
ADuM5028-5BRIZ
ADuM5028-5BRIZ-RL
ADuM5028-3BRIZ
ADuM5028-3BRIZ-RL
EVAL-ADuM5020EBZ
EVAL-ADuM5028EBZ
5.0
5.0
3.3
3.3
5.0
5.0
3.3
3.3
8-Lead SOIC_IC
8-Lead SOIC_IC
8-Lead SOIC_IC
8-Lead SOIC_IC
ADuM5020 Evaluation Board
ADuM5028 Evaluation Board
RI-8-1
RI-8-1
RI-8-1
RI-8-1
1 Z = RoHS Compliant Part.
2 The EVAL-ADuM5020EBZ is packaged with the ADuM5020-5BRWZ installed and can be used for evaluating the ADuM6020.
3 The EVAL-ADuM5028EBZ is packaged with the ADuM5028-5BRIZ installed and can be used for evaluating the ADuM6028.
4 For 5 V input operations, use the ADuM5020-5BRWZ and ADuM5028-5BRIZ. For 3.3 V input to 3.3 V output operations, use the ADuM5020-3BRWZ and the ADuM5028-
3BRIZ.
©2018 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D16520-0-12/18(A)
Rev. A | Page 20 of 20
相关型号:
ADUM5200CRWZ-RL
Dual-Channel Isolators with Integrated DC-to-DC Converter (2/0 channel directionality)
ADI
©2020 ICPDF网 联系我们和版权申明