APT60D100LCT [ADPOW]
ULTRAFAST SOFT RECOVERY RECTIFIER DIODES; 超快软恢复整流二极管![APT60D100LCT](http://pdffile.icpdf.com/pdf1/p00075/img/icpdf/APT60D100_396995_icpdf.jpg)
型号: | APT60D100LCT |
厂家: | ![]() |
描述: | ULTRAFAST SOFT RECOVERY RECTIFIER DIODES |
文件: | 总4页 (文件大小:66K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
1
3
2
1- Anode 1
2- Common Cathode
Back of Case -Cathode
3- Anode 2
APT60D100LCT 1000V 2x60A
1
3
2
ULTRAFAST SOFT RECOVERY RECTIFIER DIODES
PRODUCT APPLICATIONS
PRODUCT FEATURES
PRODUCT BENEFITS
• Parallel Diode
• Ultrafast Recovery Times
• Low Losses
-Switchmode Power Supply
-Inverters
• Free Wheeling Diode
-Motor Controllers
-Converters
• Soft Recovery Characteristics
• Popular TO-264 Package
• Low Forward Voltage
• Low Noise Switching
• Cooler Operation
• Higher Reliability Systems
• Snubber Diode
• Uninterruptible Power Supply (UPS)
• Induction Heating
• High Speed Rectifiers
• High Blocking Voltage
• Low Leakage Current
• Increased System Power
Density
MAXIMUM RATINGS
All Ratings Are Per Leg: T = 25°C unless otherwise specified.
C
APT60D100LCT
Symbol Characteristic / Test Conditions
UNIT
VR
VRRM
VRWM
IF(AV)
IF(RMS)
IFSM
Maximum D.C. Reverse Voltage
Maximum Peak Repetitive Reverse Voltage
Maximum Working Peak Reverse Voltage
Maximum Average Forward Current (TC = 50°C, Duty Cycle = 0.5)
RMS Forward Current
1000
Volts
60
100
Amps
Non-Repetitive Forward Surge Current (TJ = 45°C, 8.3ms)
Operating and StorageTemperature Range
Lead Temperature: 0.063" from Case for 10 Sec.
540
TJ,TSTG
TL
-55 to 150
300
°C
STATIC ELECTRICAL CHARACTERISTICS
Symbol Characteristic / Test Conditions
MIN
TYP
MAX
UNIT
IF = 60A
2.5
VF
Maximum Forward Voltage
IF = 120A
2.1
Volts
IF = 60A, TJ = 150°C
VR = VR Rated
VR = VR Rated, TJ = 125°C
2.0
250
500
Maximum Reverse Leakage Current
Junction Capacitance, VR = 200V
IRM
µA
CT
LS
65
10
pF
nH
Series Inductance (Lead to Lead 5mm from Base)
APT Website - http://www.advancedpower.com
USA
405 S.W. Columbia Street
EUROPE
Bend, Oregon 97702-1035
F-33700 Merignac - France
Phone: (541) 382-8028
Phone: (33) 5 57 92 15 15
FAX: (541) 388-0364
FAX: (33) 5 56 47 97 61
Avenue J.F. Kennedy Bât B4 Parc Cadéra Nord
APT60D100LCT
DYNAMIC CHARACTERISTICS
Symbol Characteristic
MIN
TYP
70
MAX
UNIT
trr1
trr2
Reverse Recovery Time, IF = 1.0A, diF/dt = -15A/µs, VR = 30V, TJ = 25°C
85
Reverse Recovery Time
TJ = 25°C
TJ = 100°C
TJ = 25°C
TJ = 100°C
TJ = 25°C
TJ = 100°C
TJ = 25°C
TJ = 100°C
TJ = 25°C
TJ = 100°C
TJ = 25°C
TJ = 100°C
70
trr3
IF = 60A, diF/dt = -480A/µs, VR = 540V
Forward Recovery Time
130
170
170
14
ns
tfr1
tfr2
IF = 60A, diF/dt = 480A/µs, VR = 540V
Reverse Recovery Current
IRRM1
IRRM2
Qrr1
Qrr2
Vfr1
Vfr2
26
36
Amps
nC
26
IF = 60A, diF/dt = -480A/µs, VR = 540V
Recovery Charge
500
1700
12
IF = 60A, diF/dt = -480A/µs, VR = 540V
Forward Recovery Voltage
Volts
A/µs
IF = 60A, diF/dt = 480A/µs, VR = 540V
Rate of Fall of Recovery Current
IF = 60A, diF/dt = -480A/µs, VR =540V (See Figure 10)
12
900
600
diM/dt
THERMAL AND MECHANICAL CHARACTERISTICS
Symbol Characteristic / Test Conditions
MIN
TYP
MAX
0.66
40
UNIT
RθJC
RθJA
Junction-to-Case Thermal Resistance
Junction-to-Ambient Thermal Resistance
°C/W
0.22
6.1
oz
WT
Package Weight
gm
10
lb•in
N•m
Torque
Maximum Mounting Torque (Screw Type = 6-32 or 3mm Machine)
1.1
1.0
0.5
D=0.5
0.2
0.1
0.1
0.05
0.05
0.02
0.01
NOTE:
0.01
t
1
SINGLE PULSE
0.005
t
2
=
DUTY FACTOR D t /t
1
2
=
P
+
T
C
PEAK T
x Z
J
DM
JC
0.001
10-5
10-4
10-3
RECTANGULAR PULSE DURATION (SECONDS)
FIGURE 1, MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs PULSE DURATION
10-2
10-1
1.0
10
APT60D100LCT
200
160
120
80
5000
4000
3000
2000
1000
0
T
= 100°C
J
V
= 540V
R
T
= 25°C
120A
60A
J
T
= 150°C
= 100°C
J
T
J
T
= -55°C
J
40
30A
0
0
1
2
3
4
5
10
F
50
100
500 1000
V , ANODE-TO-CATHODE VOLTAGE (VOLTS)
di /dt, CURRENT SLEW RATE (AMPERES/µSEC)
F
Figure 2, Forward Voltage Drop vs Forward Current
Figure 3, Reverse Recovery Charge vs Current Slew Rate
60
2.0
T
= 100°C
J
V
= 540V
R
120A
1.6
Q
rr
45
30
15
0
60A
t
rr
1.2
30A
I
RRM
0.8
0.4
0.0
t
rr
Q
rr
0
F
200
400
600
800
1000
-50 -25
0
25 50 75 100 125 150
T , JUNCTION TEMPERATURE (°C)
di /dt, CURRENT SLEW RATE (AMPERES/µSEC)
J
Figure 4, Reverse Recovery Current vs Current Slew Rate
Figure 5, Dynamic Parameters vs Junction Temperature
300
1500
1250
1000
750
500
250
0
30
T
= 100°C
T
= 100°C
J
J
V
= 540V
V
= 540V
R
R
I
= 60A
F
25
20
15
10
5
240
180
120
60
120A
60A
V
30A
fr
t
fr
0
0
0
F
200
400
600
800
1000
0
F
200
400
600
800
1000
di /dt, CURRENT SLEW RATE (AMPERES/µSEC)
di /dt, CURRENT SLEW RATE (AMPERES/µSEC)
Figure 6, Reverse Recovery Time vs Current Slew Rate
Figure 7, Forward Recovery Voltage/Time vs Current Slew Rate
2000
1000
500
100
50
0.01
0.05
0.1
0.5
R
1
5
10
50
100
200
V , REVERSE VOLTAGE (VOLTS)
Figure 8, Junction Capacitance vs Reverse Voltage
APT60D100LCT
V
r
D.U.T.
t
Q
/
30µH
rr rr
Waveform
PEARSON 411
CURRENT
TRANSFORMER
+15v
0v
diF/dt Adjust
-15v
Figure 9, Diode Reverse Recovery Test Circuit and Waveforms
1
IF - Forward Conduction Current
1
4
5
6
2
diF/dt - Current Slew Rate, Rate of Forward
Current Change Through Zero Crossing.
Zero
3
4
IRRM - Peak Reverse Recovery Current.
t
- Reverse Recovery Time Measured from Point of IF
3
rr
0.5 I
RRM
6
Current Falling Through Zero to a Tangent Line
{
diM/dt
}
0.75 I
RRM
Extrapolated Through Zero Defined by 0.75 and 0.50 IRRM
.
2
5
6
Q
- Area Under the Curve Defined by IRRM and t .
rr
rr
1
Q
t . IRRM
rr
= /
(
)
rr
2
diM/dt - Maximum Rate of Current Change During the Trailing Portion of t
rr.
Figure 10, Diode Reverse Recovery Waveform and Definitions
TO-264 Package Outline
4.60 (.181)
5.21 (.205)
19.51 (.768)
20.50 (.807)
1.80 (.071)
2.01 (.079)
3.10 (.122)
3.48 (.137)
5.79 (.228)
6.20 (.244)
25.48 (1.003)
26.49 (1.043)
2.29 (.090)
2.69 (.106)
2.29 (.090)
2.69 (.106)
19.81 (.780)
21.39 (.842)
Anode 1
Common Cathode
Anode 2
0.48 (.019)
0.84 (.033)
2.59 (.102)
3.00 (.118)
0.76 (.030)
1.30 (.051)
2.79 (.110)
3.18 (.125)
5.45 (.215) BSC
2-Plcs.
Dimensions in Millimeters and (Inches)
APT Reserves the right to change, without notice, the specifications and information contained herein.
相关型号: