E1476-80000 [AGILENT]

64-Channel 3-Wire T/C Relay Multiplexer; 64路3线T / C继电器多路复用器
E1476-80000
型号: E1476-80000
厂家: AGILENT TECHNOLOGIES, LTD.    AGILENT TECHNOLOGIES, LTD.
描述:

64-Channel 3-Wire T/C Relay Multiplexer
64路3线T / C继电器多路复用器

复用器 继电器
文件: 总4页 (文件大小:421K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Agilent E1476A 64-Channel  
3-Wire T/C Relay Multiplexer  
Data Sheet  
Features  
• 1-Slot, C-size, register based  
• Low-thermal offset relay <2 µV  
• 64 channels of temperature  
with compensation  
• 64 channels of voltage - 3-wire  
high, low, and guard  
• 64 channels 2-wire and  
32 channels 4-wire resistances  
• Includes QUIC easy-to-use  
terminal block  
Description  
Temperature Measurements  
High-integrity voltage meas-  
urements are possible with  
three-wire high, low, and guard  
switching. In addition to making  
two-wire resistance and precision  
four-wire resistance measure-  
ments, you can make up to  
64 channels of thermocouple  
temperature measurements  
with automatic cold junction  
compensation.  
The Agilent E1476A High-Density  
Reed Relay Multiplexer is a  
C-size, 1-slot, register-based  
VXI module. This low-offset,  
thermocouple compensated  
multiplexer is dynamically  
configurable providing 64 chan-  
nels of two-, three- or four-wire  
(32 channels) of switching. This  
multiplexer module consists of  
a component card with switches  
and a QUIC spring clamp termi-  
nal block that plugs onto the  
component card. The E1476A is  
ideal for applications needing a  
relay multiplexer that is dynami-  
cally configurable, and makes  
maximum high-quality, high-point  
count measurements.  
The reference thermistor is also  
accessible by both banks, each  
bank having a control switch  
allowing for either a two-wire or  
four-wire resistance measure-  
ment of the 5000 Ω reference  
thermistor mounted on the  
isothermal plane located in the  
terminal block. Using a scanning  
multimeter configuration, the  
channel relays and five control  
relays are programmed by SCPI  
commands or by register read/  
writes. SCPI command syntax  
to make a temperature scan  
of K type thermocouples is:  
MEAS:TEMP? TC, K, (@100:163)  
Refer to the Agilent Technologies  
Website for instrument driver  
availability and downloading  
instructions, as well as for  
recent product updates, if  
applicable.  
Configuration  
Product Specifications  
Each of the 64 channels provides  
separate high, low, and guard  
connections, all easily accessible  
via the quick connect screwless  
terminals on the companion  
terminal block. The multiplexer  
is organized in two banks of  
32 with each bank having its own  
voltage sense control switch and  
one bank having a current source  
control switch. This dual bank  
configuration makes it possible  
to use half the channels as sense  
channels, while the other half are  
used as current source channels,  
thus obtaining 32 four-wire mea-  
surement channels, each with  
high, low, and guard connections.  
Input  
DC:  
Maximum voltage  
120 Vdc  
120 V rms  
35 mA  
(any terminal to any other terminal or chassis):  
AC rms: Maximum voltage  
(any terminal to any other terminal or chassis):  
Maximum current  
(per channel common, non-inductive):  
Maximum power per channel:  
4 VA  
DC  
AC  
Maximum thermal  
offset per channel, differential Hi-Lo:  
<4 µV, <2 µV  
(10 samples averaged)  
Closed channel resistance:  
100 Ω 5 Ω  
Insulation resistance (between any two points): 10E9 Ω, 40ºC, 95% RH  
Insulation resistance (Hi to Lo, power off):  
n/a  
One 6 cm (2.5-in) analog bus  
cable (E1400-61605) is shipped  
with each module to allow you to  
interconnect the E1411B 5.5-digit  
multimeter to one or more E1476A  
multiplexers via its front panel  
analog bus connector. For con-  
nection to an external voltmeter  
or other VXI multimeter with  
conventional front panel con-  
nectors, access to the analog bus  
lines is available in the terminal  
block. This allows you to connect  
the analog bus signal lines to the  
multimeter inputs using ordinary  
hookup wire.  
Maximum bandwidth  
(-3 dB, 50 Ω source/load):  
100 kHz  
Crosstalk (channel-to-channel):  
100 kHz:  
10 MHz:  
Both:  
-70 dB  
-45 dB  
n/a  
Closed channel capacitance:  
<175 pf H-L, <300 pf L-G,  
<1500 pf G-C  
General Characteristics  
Relays:  
Reed relays  
Break-before-make  
Power down state:  
Power up state:  
Relays open on power down  
Relays open on power up  
Minimum relay life:  
No load:  
5 x 10E9 operations  
10E7 operations  
Rated load:  
Reference junction measurement  
accuracy (18 to 28 ºC operating):  
0.38 °C  
Strain gage excitation:  
Screw terminal wire size:  
Scanning rate:  
n/a  
22 to 26 AWG (0.5, 0.75, 0.9 mm)  
333 channels/s typ.  
2
Ordering Information  
Description  
General Specifications  
VXI Characteristics  
Product No.  
64-channel 3-wire T/C Relay Multiplexer  
Pre-QUIC-type terminal block  
E1476A  
VXI device type:  
Register-based,  
A16, slave only  
E1476A 106  
E1476A A3E**  
E1476A OB3  
E1476-80000  
E1476-80010  
E1476-80011**  
Size:  
C
Crimp-and-insert terminal block**  
Slots:  
1
Service Manual  
Connectors:  
Shared memory:  
VXI busses:  
C-size capability:  
P1/2  
None  
None  
n/a  
Extra pre-QUIC-type terminal block (if ordered seperately)  
Extra QUIC-type terminal block (if ordered seperately)  
Extra crimp-and-insert terminal block (if ordered seperately)**  
Notes:  
** Crimp-and-insert contacts are not included.  
Crimp-and-insert contacts order 1252-6533 or ERNI 014728  
Instrument Drivers  
Crimp-and-insert tools  
See the Agilent Technologies Website  
http://www.agilent.com/find/inst_drivers  
for availability and downloading.  
Hand crimp tool 8710-2306 or ERNI 014374  
Pin extractor tool 8710-2307 or ERNI 471555  
Extra crimp and insert connectors  
96 pin connector body 1252-6532 or ERNI 024069  
160 pin connector body 1252-6531 or ERNI 024070  
Command module  
firmware:  
Downloadable  
Command module firmware rev.: A.06  
I-SCPI Win 3.1:  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
I-SCPI Series 700:  
C-SCPI LynxOS:  
C-SCPI Series 700:  
Panel Drivers:  
Agilent E1476A terminal block  
VXIplug&play Win Framework:  
VXIplug&play Win 95/NT Framework: Yes  
VXIplug&play HP-UX Framework:  
No  
Module Current  
IPM  
IDM  
+5 V:  
+12 V:  
-12 V:  
+24 V:  
-24 V:  
-5.2 V:  
-2 V:  
0.1  
0
0
0
0
0.1  
0
0
0
0
0
0
0
0
Cooling Slot  
Watts/slot:  
4.00  
0.10  
0.30  
∆P mm H O:  
2
Air Flow liter/s:  
3
Agilent E1476A Circuit Diagram  
Remove all doubt  
www.agilent.com  
For more information on Agilent Technologies’  
products, applications or services, please  
contact your local Agilent office. The complete  
list is available at:  
www.agilent.com/find/emailupdates  
Get the latest information on the  
products and applications you select.  
Our repair and calibration services  
will get your equipment back to you,  
performing like new, when prom-  
ised. You will get full value out of  
your Agilent equipment through-  
out its lifetime. Your equipment  
will be serviced by Agilent-trained  
technicians using the latest factory  
calibration procedures, automated  
repair diagnostics and genuine parts.  
You will always have the utmost  
confidence in your measurements.  
www.agilent.com/find/contactus  
www.agilent.com/find/agilentdirect  
Quickly choose and use your test  
equipment solutions with confidence.  
Americas  
Canada  
Latin America  
United States  
(877) 894-4414  
305 269 7500  
(800) 829-4444  
Asia Pacific  
www.agilent.com/find/open  
Australia  
China  
Hong Kong  
India  
Japan  
Korea  
1 800 629 485  
800 810 0189  
800 938 693  
1 800 112 929  
0120 (421) 345  
080 769 0800  
1 800 888 848  
1 800 375 8100  
0800 047 866  
1 800 226 008  
Agilent Open simplifies the process  
of connecting and programming  
test systems to help engineers  
design, validate and manufacture  
electronic products. Agilent offers  
open connectivity for a broad range  
of system-ready instruments, open  
industry software, PC-standard I/O  
and global support, which are  
combined to more easily integrate  
test system development.  
Agilent offers a wide range of ad-  
ditional expert test and measure-  
ment services for your equipment,  
including initial start-up assistance  
onsite education and training, as  
well as design, system integration,  
and project management.  
Malaysia  
Singapore  
Taiwan  
Thailand  
For more information on repair and  
calibration services, go to:  
Europe & Middle East  
Austria  
Belgium  
Denmark  
Finland  
France  
0820 87 44 11  
www.agilent.com/find/removealldoubt  
www.lxistandard.org  
32 (0) 2 404 93 40  
45 70 13 15 15  
LXI is the LAN-based successor to  
GPIB, providing faster, more efficient  
connectivity. Agilent is a founding  
member of the LXI consortium.  
358 (0) 10 855 2100  
0825 010 700*  
*0.125 € fixed network rates  
Germany  
01805 24 6333**  
**0.14 €/minute  
Ireland  
1890 924 204  
Israel  
972-3-9288-504/544  
39 02 92 60 8484  
31 (0) 20 547 2111  
34 (91) 631 3300  
0200-88 22 55  
Italy  
Netherlands  
Spain  
Sweden  
Switzerland (French)  
Switzerland (German) 0800 80 53 53 (Opt 1)  
United Kingdom  
41 (21) 8113811(Opt 2)  
44 (0) 118 9276201  
Other European Countries:  
www.agilent.com/find/contactus  
Revised: October 24, 2007  
Product specifications and descriptions  
in this document subject to change  
without notice.  
© Agilent Technologies, Inc. 2008  
Printed in USA, January 11 2008  
5965-5607E  

相关型号:

E1476-80010

64-Channel 3-Wire T/C Relay Multiplexer
AGILENT

E1476-80011

64-Channel 3-Wire T/C Relay Multiplexer
AGILENT

E1476A

64-Channel 3-Wire T/C Relay Multiplexer
AGILENT

E1476A106

64-Channel 3-Wire T/C Relay Multiplexer
AGILENT

E1476AA3E

64-Channel 3-Wire T/C Relay Multiplexer
AGILENT

E1476AOB3

64-Channel 3-Wire T/C Relay Multiplexer
AGILENT

E148-12A

Safety Transformers
EICHHOFF

E148-12E

Safety Transformers
EICHHOFF

E148-12F

Safety Transformers
EICHHOFF

E148-32A

Safety Transformers
EICHHOFF

E148-32E

Safety Transformers
EICHHOFF

E148-32F

Safety Transformers
EICHHOFF