AM2L-051515D-NZ [AIMTEC]
2 Watt | DC-DC Converter; 2瓦| DC- DC转换器型号: | AM2L-051515D-NZ |
厂家: | AIMTEC |
描述: | 2 Watt | DC-DC Converter |
文件: | 总5页 (文件大小:346K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series AM2L-NZ
2 Watt | DC-DC Converter
FEATURES:
Low Profile SMD (Surface Mount Device)
1000VDC & 6000VDC Isolation
Industry Standard Pinout
MTBF>1,000,000 hours
Operating temperature: -40°C to +85°C
High Efficiency up to 85%
Unregulated Single, Dual, Dual Separated Output Models
Models
Single output
Input Voltage
(V)
Output Voltage
Output Current
Isolation
(VDC)
1000
Efficiency
Model
(V)
5
9
12
15
5
9
12
15
max (mA)
400
(%)
80
82
84
84
82
83
85
85
AM2L-0505S-NZ
AM2L-0509S-NZ
AM2L-0512S-NZ
AM2L-0515S-NZ
AM2L-1205S-NZ
AM2L-1209S-NZ
AM2L-1212S-NZ
AM2L-1215S-NZ
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
10.8-13.2
222
167
133
400
222
167
133
1000
1000
1000
1000
1000
1000
1000
AM2L-0505SH60-NZ
AM2L-0512SH60-NZ
AM2L-0515SH60-NZ
AM2L-1205SH60-NZ
AM2L-1212SH60-NZ
AM2L-1215SH60-NZ
AM2L-2405SH60-NZ
AM2L-2412SH60-NZ
AM2L-2415SH60-NZ
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
21.6-26.4
21.6-26.4
21.6-26.4
5
12
15
5
12
15
5
400
167
133
400
167
133
400
167
133
6000
6000
6000
6000
6000
6000
6000
6000
6000
76
79
78
76
80
79
77
80
78
12
15
Models
Dual output
Input Voltage
(V)
Output Voltage
Output Current
Isolation
(VDC)
1000
Efficiency
Model
(V)
±5
±9
±12
±15
±5
±9
±12
±15
max (mA)
±200
±111
±83
(%)
82
83
84
82
83
84
84
85
AM2L-0505D-NZ
AM2L-0509D-NZ
AM2L-0512D-NZ
AM2L-0515D-NZ
AM2L-1205D-NZ
AM2L-1209D-NZ
AM2L-1212D-NZ
AM2L-1215D-NZ
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
10.8-13.2
1000
1000
1000
1000
1000
1000
1000
±67
±200
±111
±83
±67
Models
Dual Separated output
Input Voltage
Output Voltage
Output Current
max (mA)
200/200
Isolation
(VDC)
1000
Efficiency
Model
(V)
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
(V)
5/5
9/9
15/15
5/5
9/9
(%)
82
83
85
82
83
85
AM2L-050505D-NZ
AM2L-050909D-NZ
AM2L-051515D-NZ
AM2L-120505D-NZ
AM2L-120909D-NZ
AM2L-121515D-NZ
112/112
67/67
200/200
112/112
67/67
1000
1000
1000
1000
15/15
1000
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
www.aimtec.com
F 051e R12.H
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2L-NZ
2 Watt | DC-DC Converter
Input Specifications
Parameters
Nominal
Typical
4.5-5.5
Maximum
Units
5
Voltage range
12
24
10.8-13.2
21.6-26.4
VDC
Isolation Specifications
Parameters
Tested I/O voltage
Tested V1 output/ V2 output
Capacitance V input/V output
Capacitance V1 output/V2 output
Resistance
Conditions
60 sec
Typical
Rated
1000, 6000
Units
VDC
VDC
pF
pF
MOhm
60 sec
1000
60
60
500VDC
500VDC
500Vdc
>1000
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Voltage accuracy
See Tolerance Graph
1000VDC Momentary
6000VDC Continuous
±5
%
1 sec
Short Circuit protection
Short Circuit Restart
Auto-Recovery
Line voltage regulation
For a 1% change of Vin
±1.2
12.8
8.3
6.8
6.3
±0.03
150
10
%
%
Load voltage regulation (5 Vout)
Load voltage regulation (9 Vout)
Load voltage regulation (12 Vout)
Load voltage regulation (15 Vout)
Temperature coefficient
From 10% load to 100% load
At 100% load
20MHz Bandwidth
%/oC
mV p-p
% of Max
Ripple & Noise*
Minimum Load Current**
* Test ripple & noise by “Parallel Cable Method” as described in Application Note “Ripple and Noise Measurement of Brick &
POL DC-DC Converters” available on Aimtec’s website www.aimtec.com
** If the operating output current is less than 10% of maximum it is recommended to install a load resister in parallel with the
load to ensure the actual load current meets the minimum load current requirement.
General Specifications
Parameters
Conditions
100% load, nominal input
Typical
100
Maximum
Units
KHz
oC
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
-40 to + 85
-55 to + 125
oC
100
95
oC
Free Air Convection
Humidity
% RH
Case material
Plastic(UL94-V0)
1000VDC
6000VDC
2.1
3.8
Weight
g
Single, Dual, Dual Separated 1000VDC
Single 6000VDC
0.70 x 0.70 x 0.24 inches
0.94 x 0.79 x 0.32 inches 23.86 x 18.50 x 8.00mm
17.78 x 17.78 x 6.00 mm
Dimensions (L x W x H)
MTBF
> 1,000, 000 hours (MIL-HDBK -217F, Ground Benign, t=+25ºC)
Maximum Soldering Temperature
1.5mm from case for 10 seconds
260
oC
Safety Specifications
Parameters
CE (for 6000VDC isolation models)
EN 60601-1-1; EN 60601-1-2
Agency approvals
Standards
www.aimtec.com
F 051e R12.H
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2L-NZ
2 Watt | DC-DC Converter
Pin Out Specifications
1000VDC
6000VDC
Dual
Separated
- Vin
Pin
1
2
3
4
5
6
7
Single
- V in
Pin
Single
Dual
1
2
5
6
7
8
-Vin
+ Vin
NC
- Vout
+Vout
NC
- Vin
+ Vin
-Vout
Common
+Vout
NC
No Pin
No Pin
No Pin
No Pin
No Pin
NC
+ Vin
-V1out
+V1out
NC
NC
8
9
NC
9
NC
NC
NC
NC
NC
-Vout
NC
NC
NC
+V2out
-V2out
NC
+V out
-V out
No Pin
No Pin
No Pin
No Pin
No Pin
+V in
10
12
13
14
10
11
12
13
14
15
16
NC
NC
NC
NOTE: On dual output models Pin 5 and Pin 10 are connected internally together.
Either Pin 5 or Pin 10, or both can be used as the -Vout
NC: not connected
Dimensions
1000VDC
Side View
17.78
(0.70)
Front View
A
2.75
(0.11)
6.00 5.75
(0.24) (0.23)
0.25
(0.01)
2.54
(0.10)
A
1.27
(0.05)
Top View
17.78
0.25
(0.01)
(0.70)
2.54
1.00
(0.04)
2.00
(0.08)
(0.10)
5.00º angle
14
13
12
10
9
8
1.30 ±0.13
(0.05 ±0.005) MAX
12.70
(0.50)
17.78
(0.70)
1
2
3
5
6
7
www.aimtec.com
F 051e R12.H
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2L-NZ
2 Watt | DC-DC Converter
Dimensions
6000VDC
Tolerance Envelope Graph
Typical Load Line
+10%
+5%
+2.5%
-2.5%
-7.5%
100%
10%
50%
Output Current(%)
www.aimtec.com
F 051e R12.H
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2L-NZ
2 Watt | DC-DC Converter
Recommended Filter Circuit
L
L
Single Output
Dual Output
L
L
+Vout
+Vout
+ Vin
Cin
+ Vin
+
Cout
+
+
Common
Cin
Cout
+
DC
DC
DC
DC
+
Cout
-Vout
L
- Vin
- Vin
- Vin
L
L
Dual Separated Output
L
+V1output
-V1 output
+V2 output
-V2 output
+ Vin
Cin
+
+
Cout
+
DC
DC
Cout
- Vin
If it is required to decrease the input/output ripple an “LC” filter network can be installed on the input and output of the
converter (see above).
It should be noted that the inductance and the resonant frequency of the “LC” filtering network should differ from the DC/DC
converter switching frequency to avoid mutual interference.
The capacitance of the output filter capacitor must not exceed the values in the Table below to avoid startup problems and
ensure safe and reliable operation.
It’s not recommended to connect any external capacitor in the application field when output loading is less than 0.5
watt.
External Capacitor Tables
Input Capacitor (Cin)
Output Capacitor (Cout)
Single
Vout
(VDC)
5
Dual
Dual
Separated
Vout (Vdc)
5/5
Cout
(uF)
Vin
(VDC)
5
12
24
Cin
(uF)
4.7
2.2
1
Cout
(uF)
Cout
(uF)
Vout
(Vdc)
±5
±9
±12
±15
10
4.7
2.2
1
4.7
2.2
1
4.7
2.2
1
9
12
15
9/9
12/12
15/15
0.47
0.47
Overload Protection
The output circuit of these products has no protection against overload. It is recommended to install external overload
protection in the form of a self-recovery fuse or a circuit breaker in series at the converter’s input.
To achieve a high degree of output voltage regulation, over-voltage, and over-current protection it is suggested to use the
AM2LV-NZ series as an alternative.
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.H
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
相关型号:
©2020 ICPDF网 联系我们和版权申明