AM3Q-2415DZ [AIMTEC]
3 Watt | DC-DC Converter; 3瓦| DC- DC转换器型号: | AM3Q-2415DZ |
厂家: | AIMTEC |
描述: | 3 Watt | DC-DC Converter |
文件: | 总3页 (文件大小:256K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series AM3Q-Z
3 Watt | DC-DC Converter
FEATURES:
RoHS Compliant
Operating Temperature -40ºC to 85ºC
Wide 2:1 input range
High Efficiency up to 85%
Continuous short circuit
Input / Output Isolation of 500VAC
No Tantalum capacitors used inside
Over voltage protection
Models
Single output
Output
Voltage
Max
Input Voltage
Output Current
Isolation
(VAC)
Efficiency
Model
Capacitive
Load (uF)
100
(V)
max (mA)
(%)
(V)
5
12
15
5
12
15
5
12
15
5
AM3Q-0505SZ
AM3Q-0512SZ
AM3Q-0515SZ
AM3Q-1205SZ
AM3Q-1212SZ
AM3Q-1215SZ
AM3Q-2405SZ
AM3Q-2412SZ
AM3Q-2415SZ
AM3Q-4805SZ
AM3Q-4812SZ
AM3Q-4815SZ
4.5-9
4.5-9
4.5-9
9-18
9-18
9-18
18-36
18-36
18-36
36-75
36-75
36-75
600
250
200
600
250
200
600
250
200
600
250
200
500
500
500
500
500
500
500
500
500
500
500
500
67
70
70
70
74
74
71
75
75
71
76
76
100
100
100
100
100
220
220
220
220
220
220
12
15
Models
Dual output
Output
Voltage
(V)
Max
Capacitive
Load (uF)
±220
Input Voltage
Output Current
Isolation
(VAC)
Efficiency
Model
(V)
max (mA)
(%)
AM3Q-0512DZ
AM3Q-0515DZ
AM3Q-1212DZ
AM3Q-1215DZ
AM3Q-2412DZ
AM3Q-2415DZ
AM3Q-4812DZ
AM3Q-4815DZ
4.5-9
4.5-9
9-18
±12
±15
±12
±15
±12
±15
±12
±15
±130
±100
±130
±100
±130
±100
±130
±100
500
500
500
500
500
500
500
500
82
82
84
85
84
85
84
84
±100
±220
±100
±220
±100
±220
±100
9-18
18-36
18-36
36-75
36-75
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Nominal
Typical
Maximum
Units
5
4.5-9
12
24
48
9-18
18-36
36-75
Voltage range
VDC
Filter
π (Pi) Network
Start up time
No Load Input Current
Input reflected current
20
25
20
ms
mA
mA
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM3Q-Z
3 Watt | DC-DC Converter
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Conditions
Typical
500
Maximum
Units
VAC
MOhm
pF
3sec
50
Capacitance
500
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Voltage accuracy
±1
%
25% load on one output
100% load on the other output
Cross Regulation (Dual Output Models)
%
±5
5
12
6.5
12
V
Over voltage protection
Zener Diode Clamp
15
18
±12
±15
±15
±18
Short Circuit protection
Short circuit restart
Continuous
Auto Recovery
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
LL-HL
±0.5
±1
±0.02
50
% of Vin
%
Load:0-100% unbalanced
%/oC
20MHz Bandwidth
mV p-p
% of Max
Minimum Load Current
0
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Conditions
100% load
Derating above 60ºC
Typical
100
Maximum
Units
KHz
oC
-40 to +85
-40 to +125
oC
100
oC
Free Air Convection
Humidity
Case material
Weight
95
% RH
g
Nickel Coated Copper
16
Dimensions (L x W x H)
1.37 x 0.90 x 0.28 inches
35.00 x 23.00 x 7.00 mm
MTBF
>1.6Mhrs ( MIL-HDBK -217F, Ground Benign, t=+25°C )
±3
Transient recovery deviation
%
Safety Specifications
Parameters
Standards
Designed to meet IEC/EN 60950-1
Pin Out Specifications
Pin
1
2
3
4
Single
-V Input
+V Input
+V Output
NP
Dual
-V Input
+V Input
+V Output
Common
-V Output
5
-V Output
NP: Not Populated
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM3Q-Z
3 Watt | DC-DC Converter
Dimensions
Derating
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
相关型号:
©2020 ICPDF网 联系我们和版权申明