AM40UW-4805SZ-K [AIMTEC]
DC/DC Converter; Product Weight (grams): 87; Input voltage min (V): 18; Input voltage max (V): 75; Output voltage min: 5; Output voltage max: 5; Output voltage dual assymetric (y/n): Single; Output Power (W): 40; Max Output current (A): 8; Efficiency (%): 92; Max Capacitive load (µF): 13000; Package type: 2x2; Mounting: PCB; W (in): 2; L (in): 2; H (in): 0.4; W (mm): 50.8; L (mm): 50.8; H (mm): 10.2; Min Operating temperature: -40; Max operating temperature (°C): 85; Isolation (VDC): 1600; EMC compliance 2: EN 55032 Class A; Case material: Copper; Application 4 (building automation/IoT): 1; M;型号: | AM40UW-4805SZ-K |
厂家: | AIMTEC |
描述: | DC/DC Converter; Product Weight (grams): 87; Input voltage min (V): 18; Input voltage max (V): 75; Output voltage min: 5; Output voltage max: 5; Output voltage dual assymetric (y/n): Single; Output Power (W): 40; Max Output current (A): 8; Efficiency (%): 92; Max Capacitive load (µF): 13000; Package type: 2x2; Mounting: PCB; W (in): 2; L (in): 2; H (in): 0.4; W (mm): 50.8; L (mm): 50.8; H (mm): 10.2; Min Operating temperature: -40; Max operating temperature (°C): 85; Isolation (VDC): 1600; EMC compliance 2: EN 55032 Class A; Case material: Copper; Application 4 (building automation/IoT): 1; M PC |
文件: | 总6页 (文件大小:633K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Click on Series name for product info on aimtec.com
Series AM40UW-Z
40 Watt | DC-DC Converter
FEATURES:
• Ultra Wide Input 4:1 Range
• Full SMD Technology
• 1600 VDC Isolation
• Efficiency up to 92%
• Soft Start
•
•
•
•
Adjustable Output Voltage
Remote ON/OFF Function
Over Current, Voltage, & Temperature Protection
Operating temperature -40oC to + 85oC
Models
Single output
Output
Voltage
Output
Current max
Max
Input Voltage
Isolation
(VDC)
Efficiency
Model
Capacitive
Load (uF)
25000
13000
2300
(V)
(%)
(V)
3.3
5
12
15
3.3
5
(A)
10
8
3.35
2.65
10
8
3.35
2.65
AM40UW-2403SZ
AM40UW-2405SZ
AM40UW-2412SZ
AM40UW-2415SZ
AM40UW-4803SZ
AM40UW-4805SZ
AM40UW-4812SZ
AM40UW-4815SZ
9-36
9-36
9-36
1600
1600
1600
1600
1600
1600
1600
1600
89
91
90
90
90
92
90
90
9-36
1500
18-75
18-75
18-75
18-75
25000
13000
2300
12
15
1500
Add suffix “-K” for optional heatsink
Models
Dual output
Output
Voltage
(V)
Output
Current max
(A)
Max
Capacitive
Load (uF)
±1200
Input Voltage
Isolation
(VDC)
Efficiency
Model
(V)
(%)
AM40UW-2412DZ
AM40UW-2415DZ
AM40UW-4812DZ
AM40UW-4815DZ
9-36
9-36
18-75
18-75
±12
±15
±12
±15
±1.65
±1.35
±1.65
±1.35
1600
1600
1600
1600
89
90
80
90
±750
±1200
±750
Add suffix “-K” for optional heatsink
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Nominal
Typical
9-36
18-75
Maximum
Units
24
48
Voltage range
VDC
Filter
Start up time
π(Pi) Network
25
ms
VDC
ms
24
48
50
100
100
Absolute Maximum Rating
Peak Input Voltage time
On/Off control
ON –3.0 -12 (or open) ; OFF -0 -1.2 (or short pin 2 to pin 3)
Off idle current: 5mA
No Load Input Current
Under voltage lockout
Input reflected ripple current
100
8.6/7.9
17.6/16
mA
VDC
24 ON/OFF
48 ON/OFF
20
mA p-p
Isolation Specifications
www.aimtec.com
F 051e R12.F
Tel: +1 514 620 2722
1 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM40UW-Z
40 Watt | DC-DC Converter
Parameters
Tested I/O voltage
Resistance
Conditions
Typical
Rated
1600
Units
VDC
MOhm
pF
3 sec
>1000
2500
Capacitance
Output Specifications
Parameters
Voltage accuracy
Conditions
Typical
±1
Maximum
Units
%
25% load on one output -
100% load on second load
±5
%
Cross Regulation (Dual Output Models)
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Zener Diode Clamp
Full Load
150
Continuous
Auto-Restart
110
%
Thermal shutdown
On Case
HL-LL
Iout=0% to 100%
Iout=0% to 100%
ºC
% of Vin
%
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Ripple & Noise
±0.5
±0.5
±1
±0.02
150
%
%/oC
mV p-p
%
20MHz Bandwidth
Voltage adjustment range
Minimum Load Current
±10
0
% of Max
General Specifications
Parameters
Switching frequency
Conditions
100% load
Typical
270
Maximum
Units
KHz
With derating above 55 oC
(see graph below)
Operating temperature
-40 to +85
oC
Storage temperature
Maximum case temperature
Derating
Cooling
Humidity
-40 to +125
oC
oC
%/ oC
105
95
Above 55 oC
2
Free Air Convection
% RH
g
Case material
Weight
Nickel – coated Copper
60
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Transient recovery time
Transient recovery deviation
2.00 x 2.00 x 0.40 inches
>1500000 hrs Calculated using MIL-HDBK-217 F at +25 oC
1.5mm from case for 10 sec 260
50.81 x 50.81 10.14 mm
oC
uS
mS
250
±3
Safety Specifications
Standards
Agency Approval
CE, meet IEC 60950-1:2001
EN55022: 2006 + A1:2007, Class A
EN55024:1998 + A1:2001 + A2:2003
IEC61000-4-2:1995 + A1:1998 + A2:2000, Perf. Criteria B
IEC61000-4-3:2006, Perf. Criteria A
Safety
IEC61000-4-4:2004, Perf. Criteria B (external 220uF/100V cap required)
IEC61000-4-5:2005, Perf. Criteria B (external 220uF/100V cap required)
IEC61000-4-6:2007, Perf. Criteria A
IEC61000-4-8, Perf:1993 + A1:2000, Criteria A
www.aimtec.com
F 051e R12.F
Tel: +1 514 620 2722
2 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM40UW-Z
40 Watt | DC-DC Converter
Pin Out Specifications
Single
+V Input
-V Input
Dual
+V Input
-V Input
Pin
1
2
3
4
5
6
7
8
On/Off Control
- Sense
+ Sense
+V Output
-V Output
Trim
On/Off Control
+V Output
Common
Common
-V Output
Trim
Dimensions
50.80
(2.00)
Bottom View
4
1
2
5
6
3
7
8
2.54
(0.10)
2.54
(0.1)
45.72
(1.80)
Printed Face
Dimensions mm(inch)
Case Tolerance ±0.50 (±0.02)
Pin Pitch Tolerance ±0.35 (±0.014)
5.08
(0.20)
Ø 1.00
(0.04)
Dimensions with Optional Heatsink
50.8
(2.0)
16.3
(0.64)
SIDE
Notes: Add “-K” suffix for ordering, heatsink is affixed with thermally dissipative adhesive tape.
See derating graph for temperature performance. Heatsink material is anodized (black) aluminum, adds weight 22g to total
mass (60g). Thermal impedance of converter is: without heatsink 10℃/W and 8.8℃/W with heatsink.
www.aimtec.com
F 051e R12.F
Tel: +1 514 620 2722
3 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM40UW-Z
40 Watt | DC-DC Converter
Derating
Free Air Convection
55 ºC
100
80
60
40
20
0
64 ºC
Heatsink
Safe Operating Area
64
85
55
0
40
80
100
-40 -25
20
60
º C
Ambient Temperature
Extended temperature performance can be achieved with optional heatsink. (add suffix “–K” to part number)
Trimming
AM40UW-XX03SZ
Trim down %
Vout (VDC)
1%
2%
3%
4%
3.168
79.806
4%
5%
3.135
59.153
5%
6%
3.102
44.930
6%
7%
3.069
34.539
7%
8%
3.036
26.616
8%
9%
3.003
20.374
9%
10%
2.97
3.267
3.234
3.201
Rt down (KΩ) 315.932 172.257 112.528
15.330
10%
Trim up %
Vout (VDC)
Rt up (KΩ)
1%
2%
3%
3.333
3.366
3.399
3.432
67.715
3.465
47.676
3.498
34.824
3.531
25.880
3.564
19.297
3.597
14.249
3.63
544.612 184.034 103.305
10.255
www.aimtec.com
F 051e R12.F
Tel: +1 514 620 2722
4 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM40UW-Z
40 Watt | DC-DC Converter
AM40UW-XX05SZ
Trim down %
Vout (VDC)
1%
2%
4.9
3%
4.85
4%
4.8
5%
4.75
6%
4.7
7%
4.65
8%
4.6
9%
4.55
10%
4.5
4.95
Rt down (KΩ) 230.566 106.182
64.301
3%
43.281
4%
30.643
5%
22.207
6%
16.177
7%
11.651
8%
8.129
9%
5.310
10%
Trim up %
Vout (VDC)
Rt up (KΩ)
1%
2%
5.1
5.05
5.15
5.2
5.25
5.3
5.35
5.4
5.45
5.5
244.547 113.776
70.631
49.142
36.274
27.707
21.592
17.010
13.447
10.598
AM40UW-XX12SZ
Trim down %
Vout (VDC)
1%
2%
3%
11.64
83.928
3%
4%
11.52
55.470
4%
5%
11.4
6%
11.28
27.418
6%
7%
11.16
19.477
7%
8%
11.04
13.542
8%
9%
10.92
8.939
9%
10%
10.8
11.88
11.76
Rt down (KΩ) 327.351 142.100
38.591
5%
5.264
10%
Trim up %
Vout (VDC)
Rt up (KΩ)
1%
2%
12.12
12.24
12.36
12.48
83.929
12.6
12.72
49.767
12.84
39.919
12.96
32.508
13.08
26.728
13.2
371.425 183.645 117.623
63.489
22.094
AM40UW-XX15SZ
Trim down %
Vout (VDC)
1%
2%
3%
4%
14.4
5%
14.25
45.468
5%
6%
14.1
7%
13.95
22.625
7%
8%
13.8
9%
13.65
10.165
9%
10%
13.5
14.85
14.7
14.55
Rt down (KΩ) 433.811 174.916 100.946
65.907
4%
32.077
6%
15.596
8%
5.842
10%
Trim up %
Vout (VDC)
Rt up (KΩ)
1%
2%
3%
15.15
15.3
15.45
15.6
15.75
61.683
15.9
16.05
37.882
16.2
16.35
24.430
16.5
347.293 178.523 115.235
82.084
47.863
30.336
19.682
AM40UW-XX12DZ
Trim down %
Vout (VDC)
1%
2%
3%
11.64
63.546
3%
4%
11.52
42.058
4%
5%
11.4
6%
11.28
20.468
6%
7%
11.16
14.280
7%
8%
11.04
9.634
8%
9%
10.92
6.017
9%
10%
10.8
11.88
11.76
Rt down (KΩ) 231.849 106.217
29.116
5%
3.122
10%
Trim up %
Vout (VDC)
Rt up (KΩ)
1%
2%
12.12
12.24
12.36
62.826
12.48
42.473
12.6
12.72
22.218
12.84
16.449
12.96
12.128
13.08
8.769
13.2
229.254 103.827
30.309
6.085
AM40UW-XX15DZ
Trim down %
Vout (VDC)
1%
2%
3%
14.55
85.137
3%
4%
14.4
5%
14.25
37.693
5%
6%
14.1
7%
13.95
17.886
7%
8%
13.8
9%
13.65
7.015
9%
10%
13.5
14.85
14.7
Rt down (KΩ) 351.590 146.987
55.280
4%
26.101
6%
11.760
8%
3.232
10%
Trim up %
Vout (VDC)
Rt up (KΩ)
1%
2%
15.15
15.3
15.45
71.431
15.6
15.75
34.251
15.9
16.05
17.919
16.2
16.35
8.740
16.5
239.820 116.162
48.344
24.754
12.765
5.509
www.aimtec.com
F 051e R12.F
Tel: +1 514 620 2722
5 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM40UW-Z
40 Watt | DC-DC Converter
Control ON/OFF
+ V output
- V output
+ V input
DC/DC
Converter
On/ Off
Control
- V input
Recommended Circuits
Conducted and Radiated Emissions
Single Output
Dual Output
1000pF
2KV,
1206
1000pF
2KV,
1206
12uH
L
C3
12uH
L
C3
+V output
+V output
+V input
+V input
C1
DC/DC
Converter
C1
Load
DC/DC
Converter
Load
100uF
100V
100uF
100V
-V output
Common
-V input
-V input
-V output
C2
C2
1000pF
2KV,
1206
1000pF
2KV,
1206
EFT/Surge
+V output
+V input
C1
DC/DC
Converter
Load
220uF
100V
-V input
-V output
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.F
Tel: +1 514 620 2722
6 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
相关型号: