AM4TW-2405S-RVZ [AIMTEC]
4 Watt | DC-DC Converter; 4瓦| DC- DC转换器型号: | AM4TW-2405S-RVZ |
厂家: | AIMTEC |
描述: | 4 Watt | DC-DC Converter |
文件: | 总3页 (文件大小:407K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series AM4TW-RVZ
4 Watt | DC-DC Converter
FEATURES:
• Wide Input Range (4:1)
• 24 Pin DIP Package
• Metal package
• Operating temperature -40oC to + 85oC
• Input / Output isolation 1500 VDC
• Pin compatible with multiple manufacturers
• Continuous short circuit protection
• High efficiency up to 75%
Models
Single output
Input Voltage
Output Voltage
Output Current Capacitive load,
Efficiency
Model
(V)
9-36
9-36
9-36
(V)
3.3
5
12
15
3.3
5
max (mA)
1000
800
max (μF)
1000
1000
320
(%)
66
71
74
74
66
72
73
74
AM4TW-2403S-RVZ
AM4TW-2405S-RVZ
AM4TW-2412S-RVZ
AM4TW-2415S-RVZ
AM4TW-4803S-RVZ
AM4TW-4805S-RVZ
AM4TW-4812S-RVZ
AM4TW-4815S-RVZ
333
9-36
220
266
18-72
18-72
18-72
18-72
1000
1000
320
1000
800
333
12
15
266
220
Models
Dual output
Input Voltage Output Voltage
Output Current
max (mA)
±400
Capacitive load,
Efficiency
Model
(V)
9-36
(V)
±5
max (μF)
±470
±100
±68
±470
±100
±68
(%)
70
72
75
70
72
73
AM4TW-2405D-RVZ
AM4TW-2412D-RVZ
AM4TW-2415D-RVZ
AM4TW-4805D-RVZ
AM4TW-4812D-RVZ
AM4TW-4815D-RVZ
9-36
9-36
18-72
18-72
18-72
±12
±15
±5
±12
±15
±166
±133
±400
±166
±133
Input Specifications
Parameters
Nominal
Typical
Maximum
Units
24
48
9-36
18-72
VDC
Voltage Range
Filter
π (Pi) Network
Start up time
Peak Input Voltage time
Absolute Max Rating
20
15
-0.7-40
Ms
Ms
VDC
24 Vin
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Conditions
Typical
Rated
1500
Units
VDC
MOhm
pF
3 sec
> 1000
Capacitance
60
Output Specifications
Parameters
Voltage Balance
Conditions
Balanced Load
Typical
±1
Maximum
Units
%
Voltage accuracy
±1
%
Short circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Continuous
Auto Recovery
±0.5
±0.5
±0.02
60
%
%
%/oC
mV p-p
At 20MHz Bandwidth
www.aimtec.com
F 051e R13.B
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM4TW-RVZ
4 Watt | DC-DC Converter
General Specifications
Parameters
Switching frequency
Conditions
100% load
Typical
100-400
Maximum
Units
KHz
oC
Operating temperature
Storage temperature
Max Case temperature
Cooling
Full Load (see derating chart)
-40 to +85
-40 to +125
oC
100
95
oC
Free air convection
Humidity
%
Case material
Weight
Nickel coated copper
15
g
Dimensions(L x W x H) Tolerance ±0.5 mm or ±0.02 inches
MTBF
1.25 x 0.8 x 0.4 inches
31.75 x 20.32 x 10.16 mm
>2,200,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
Safety Specifications
Parameters
Standards
Designed to meet IEC 60950-1
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Pin Out Specifications
Pin
1500 VDC
Single
-V Input
-V Input
No pin
Dual
-V Input
-V Input
Common
-V Output
+V Output
Common
+V Input
+V Input
2
3
9
11
14
16
22
23
N.C.
+V Output
-V Output
+V Input
+V Input
www.aimtec.com
F 051e R13.B
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM4TW-RVZ
4 Watt | DC-DC Converter
Dimensions
22.86
(0.90)
31.75
(1.25)
0.50
(0.02)
2
3
11
9
Bottom View
23 22
16 14
2.54
(0.10)
5.08
(0.20)
Built-in Stand-offs to
ease PCB cleaning
Printed Face
Derating
Free Air Convection
º C
85
100
80
60
40
20
0
Safe Operating Area
0
50
85
100
-40
25
75
º C
Ambient Temperature
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R13.B
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
相关型号:
©2020 ICPDF网 联系我们和版权申明