AME3-5SCJZ [AIMTEC]

Input: 85-264VAC, 47-63Hz, or 100-370 VDC;
AME3-5SCJZ
型号: AME3-5SCJZ
厂家: AIMTEC    AIMTEC
描述:

Input: 85-264VAC, 47-63Hz, or 100-370 VDC

文件: 总3页 (文件大小:159K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Click on Series name for product info on aimtec.com  
Series AME3-CJZ  
3 Watt | AC-DC / DC-DC Converter  
FEATURES:  
Picture coming soon  
I/O Isolation 3000VAC  
Class II Power supply  
Low no load consumption ≤ 0.3W  
Operating Temp: -25°C to +70°C  
Input: 85-264VAC, 47-63Hz, or 100-370 VDC  
Over current and Over voltage Protection  
Continuous Short Circuit Protection  
Models  
Single output  
Maximum  
capacitive  
Load  
(µF)  
Efficiency  
(%)  
Input  
Voltage  
(VDC)  
Temperature  
range  
Output  
Voltage  
(V)  
Output  
Current max  
(mA)  
Input Voltage  
Model  
(VAC/Hz)  
230  
(ºC)  
VAC  
AME3-3.3SCJZ  
AME3-5SCJZ  
AME3-9SCJZ  
AME3-12SCJZ  
AME3-15SCJZ  
AME3-24SCJZ  
85-264/47-63  
85-264/47-63  
85-264/47-63  
85-264/47-63  
85-264/47-63  
85-264/47-63  
100-370  
100-370  
100-370  
100-370  
100-370  
100-370  
-25 to +70  
-25 to +70  
-25 to +70  
-25 to +70  
-25 to +70  
-25 to +70  
3.3  
5
9
12  
15  
24  
700  
600  
330  
250  
200  
125  
6000  
6000  
1500  
1500  
1000  
330  
66  
74  
75  
77  
77  
78  
Input Specifications  
Parameters  
Conditions  
Typical  
Maximum  
Units  
mA  
mA  
A
A
mA  
A
115 VAC  
230 VAC  
115 VAC  
230 VAC  
65  
30  
10  
20  
0.1  
1
Current (full load)  
Inrush current <2ms (cold start)  
Leakage current  
External fuse  
230VAC/50Hz, rms  
Recommended slow blow type  
Output Specifications  
Parameters  
Conditions  
Typical  
Maximum  
Units  
3.3V output  
Others  
±3  
±2  
Voltage accuracy  
%
Line regulation  
Load regulation  
Minimum load  
Ripple & Noise  
Hold up time  
LL-HL, Full Load  
10% - 100% load, nominal input  
±0.5  
±1  
10  
50  
50  
%
%
%
20MHz bandwidth, 115/230VAC, Full Load  
230VAC  
100  
mV p-p  
ms  
Isolation Specifications  
Parameters  
Tested I/O voltage  
Conditions  
Typical  
Rated  
3000  
Units  
VAC  
MΩ  
60 sec  
Isolation Resistance  
>1000  
General Specifications  
Parameters  
Switching frequency  
Over Current protection  
Conditions  
Typical  
115  
110  
Maximum  
Units  
KHz  
% of Iout  
Auto recovery  
3.3/5V output  
9V output  
12/15V output  
24V output  
7.5  
12  
20  
30  
Over Voltage protection  
VDC  
Short circuit protection  
Operating temperature  
Storage temperature  
Temperature coefficient  
Maximum Case temperature  
Humidity  
Auto recovery, Continuous  
-25 to +70  
With derating above 55°C  
°C  
°C  
%/°C  
°C  
-25 to +105  
±0.02  
95  
95  
Non condensing  
% RH  
Case material  
Plastic resin (flammability to UL 94V-0)  
www.aimtec.com  
F 052e R8  
Tel: +1 514 620 2722  
1 of 3  
Toll free: + 1 888 9 AIMTEC  
(924 6832)  
North America only  
Series AME3-CJZ  
3 Watt | AC-DC / DC-DC Converter  
General Specifications (continued)  
Parameters  
Weight  
Conditions  
Typical  
Maximum  
Units  
25  
g
Cooling  
Free air convection  
Dimensions (L x W x H)  
MTBF  
1.46 x 0.96 x 0.71 (37.00 x 24.50 x 18.00mm)  
> 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load  
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load  
unless otherwise specified.  
Safety Specifications  
Parameters  
Approvals  
cULus, CE pending  
Information technology Equipment  
EMI - Conducted and radiated emission  
Electrostatic Discharge Immunity  
RF, Electromagnetic Field Immunity  
Electrical Fast Transient/Burst Immunity  
Surge Immunity(1KV)  
RF, Conducted Disturbance Immunity  
Power frequency Magnetic Field Immunity  
Voltage dips, Short Interruptions Immunity  
Meets IEC/EN/UL 60950-1  
EN55022, class A  
IEC 61000-4-2, Contact:±6KV/Air:±8KV, Criteria B  
IEC 61000-4-3, 10V/m, Criteria A  
IEC 61000-4-4, ±2KV, Criteria B, with application circuit  
IEC 61000-4-5, ±1KV/±2KV, Criteria B, with application circuit  
IEC 61000-4-6, 10Vrms, Criteria A  
Standards  
IEC 61000-4-8, 10A/m, Criteria A  
IEC 61000-4-11, 0-70%, Criteria B  
Pin Out Specifications  
Dimensions  
Pin  
Single  
30.48  
(1.20)  
37.00  
(1.46)  
1
3
13  
14  
16  
AC Input (L)  
AC Input (N)  
NC  
-V Output  
+V Output  
0.60  
(0.02)  
3
1
13  
Bottom View  
16 14  
5.08  
(0.20)  
Printed Face  
All dimensions are typical: millimeters (inches)  
Pin Diameter: 0.60 ± 0.10 (0.02 ± 0.004)  
Pin Pitch Tolerance: ± 0.35 (±0.014)  
Case Tolerance: ± 0.5 (±0.02)  
www.aimtec.com  
F 052e R8  
Tel: +1 514 620 2722  
2 of 3  
Toll free: + 1 888 9 AIMTEC  
(924 6832)  
North America only  
Series AME3-CJZ  
3 Watt | AC-DC / DC-DC Converter  
Derating  
Free Air Convection at 25°C  
Free Air Convection  
100  
100  
80  
75  
80  
Safe Operating Area  
70  
Safe Operating Area  
Input 100-240VAC or  
120-340VDC  
60  
40  
20  
60  
50  
40  
20  
0
0
85  
100  
240  
264  
70  
0
20  
40  
5560  
80  
- 25  
-
20  
100  
(100)  
(120)  
(340)  
(370)  
º C  
Ambient Temperature  
Input Voltage VAC (VDC)  
Application circuit  
Single Output  
FUSE  
1A/250V  
AC L  
4
3
+ Vout  
AC L  
TVS  
+
MOV  
S14K350  
AC  
DC  
C1  
1µF/50V  
C2  
AC N  
AC N  
- Vout  
*GND connection not allowed  
Class B compliance recommended circuit  
Single Output  
LCM  
10-30mH  
LDM  
4.7µH/2A  
FUSE  
1A/250V  
+Vout  
+Vout  
- Vout  
AC L  
AC N  
CY1  
1nF/  
400VAC  
TVS  
C2  
+
CX  
0.1µF/  
275VAC  
MOV  
S14K350  
AC  
DC  
C1  
1µF/50V  
CY2  
1nF/  
400VAC  
AC N  
AC L  
- Vout  
GND  
Model  
C2  
TVS  
3.3 & 5 Vout  
9Vout  
12 & 15 Vout  
24 Vout  
150 µF / 35V  
120 µF / 35V  
120 µF / 35V  
68 µF / 35V  
7V  
12V  
20V  
30V  
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled  
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the  
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,  
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components  
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This  
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate  
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.  
www.aimtec.com  
F 052e R8  
Tel: +1 514 620 2722  
3 of 3  
Toll free: + 1 888 9 AIMTEC  
(924 6832)  
North America only  

相关型号:

AME3-5SNJZ

3 Watt I AC-DC / DC-DC Converter
AIMTEC

AME3-9SBJZ

AC-DC / DC-DC Converter
AIMTEC

AME3-9SCJZ

Input: 85-264VAC, 47-63Hz, or 100-370 VDC
AIMTEC

AME3-AZ

Over load, Short Circuit Protection
AIMTEC

AME3-AZ_16

3Watt | AC-DC Converter
AIMTEC

AME3-BJZ

AC-DC / DC-DC Converter
AIMTEC

AME3-CJZ

Input: 85-264VAC, 47-63Hz, or 100-370 VDC
AIMTEC

AME3-NJZ

3 Watt I AC-DC / DC-DC Converter
AIMTEC

AME30

30 watt encapsulated ac-dc converter
AIMTEC

AME30-12D

30 watt encapsulated ac-dc converter
AIMTEC

AME30-12DMAZ

30 Watt | AC-DC Converter
AIMTEC

AME30-12S

30 watt encapsulated ac-dc converter
AIMTEC