AMEC15-3.3SMAZ [AIMTEC]
15 Watt | AC-DC Converter; 15瓦特| AC-DC转换器型号: | AMEC15-3.3SMAZ |
厂家: | AIMTEC |
描述: | 15 Watt | AC-DC Converter |
文件: | 总5页 (文件大小:580K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series AMEC15-MAZ
15 Watt | AC-DC Converter
FEATURES:
•
•
•
•
•
Connector on Input & Output
•
•
•
•
•
RoHS compliant
Soft start
Energy Star compliant
CE, cULus, CB approvals
4000VAC I/O Isolation
Operating temperature: -40 to +80°C
Over load, Over Voltage, Short Circuit Protection
Optional DIN Rail mounting bracket
Universal input: 90-264VAC, 47-440Hz
CB
Models
Single output
Output
Voltage
(V)
Output
Current
max (A)
Maximum
Capacitive Load
Input Voltage
Input voltage
Efficiency
Model
(VAC/Hz)
(VDC)
(%)
(µF)
AMEC15-3.3SMAZ
AMEC15-5SMAZ
AMEC15-12SMAZ
AMEC15-15SMAZ
AMEC15-24SMAZ
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
120-370
120-370
120-370
120-370
120-370
3.3
5
12
15
24
3
3
1.25
1
4700
2200
1000
680
74
78
81
81
83
0.63
470
Models
Dual output
Output
Voltage
(V)
Output
Current
max (A)
Maximum
Capacitive Load
(µF)
Input Voltage
Input voltage
Efficiency
Model
(VAC/Hz)
(VDC)
(%)
AMEC15-5DMAZ
AMEC15-12DMAZ
AMEC15-15DMAZ
90-264/47-440
90-264/47-440
90-264/47-440
120-370
120-370
120-370
±5
±12
±15
±1.5
±0.63
±0.5
±1000*
±470*
±330*
78
80
81
Input Specifications
Parameters
Conditions
115VAC
230VAC
115 VAC
230 VAC
115 VAC
264 VAC
slow blow type
No load
Typical
Maximum
Units
mA
mA
A
350
180
10
20
0.1
0.2
Current
Inrush current <2ms
Leakage current
A
mA
mA
A
W
VAC
External Fuse (recommend)
Input Dissipation
Under Voltage Protection
2
<0.5
88
Output Specifications
Parameters
Voltage accuracy
Conditions
Typical
±2
Maximum
Units
%
Line regulation
LL-HL
0-100%
±0.5
±0.5
±5
200
±2
%
%
%
µs
Load regulation (single output)
Cross regulation (dual output)
Transient Recovery Time
Transient Recovery Deviation
Ripple & Noise*
25% load - 1st out, 100% load – 2nd out
25% load step
20MHz bandwidth
min
% of Vout
mVp-p
ms
100
20
Hold-up time
*Ripple & Noise measured with 1μF M/C and 47μF E/C
www.aimtec.com
F 052e R8.N
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEC15-MAZ
15 Watt | AC-DC Converter
Isolation Specifications
Parameters
Tested I/O voltage
Conditions
Typical
Rated
4000
Units
VAC
MΩ
3sec
Isolation resistance
>1000
General Specifications
Parameters
Switching frequency
Start up time
Conditions
Typical
132
900
Maximum
Units
KHz
mS
Over load protection
Over voltage protection
Short Circuit protection
Short Circuit restart
Operating temperature
Storage temperature
Max Case temperature
Temperature coefficient
Cooling
Auto recovery, hiccup mode
>131
Zener diode clamp
Continuous
Auto recovery
%
With derating over 55 oC (10CFM)
-40 to +80
-50 to +100
oC
oC
100
oC
±0.02
Free air convection
% / oC
Humidity
Weight
95
% RH
g
100
Dimensions (L x W x H)
MTBF
3.62 x 2.56 x 0.94 inches
92.0 x 65.0 x 24.0 mm
> 400 000hrs (MIL-HDBK -217F, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Environment Approval
Parameters
Conditions
Wave form: Half sine wave
Acceleration amplitude: 5gn
Bump duration: 30 ms
Shock
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Displacement: 1mm
Acceleration: 3g
Vibrations
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
Safety & EMC Specifications
Parameters
Agency approvals
cULus, CE, CB
Medical Electrical Equipment
Information technology Equipment
Harmonic Current Emissions
EMI - Conducted and radiated emission
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
IEC\EN\UL 60601-1, CSA-C22.2 No. 601.1-M90
EN 60950-1:2006+A11:2009
IEC/EN 61000-3-2, (EN60555-2)
EN55011, class B
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
Standards
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
www.aimtec.com
F 052e R8.N
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEC15-MAZ
15 Watt | AC-DC Converter
Derating
A
A
B
Free Air
100
80
Convection
40 º C
B
60
10 CFM
55 º C
Safe Operating Area
40
20
0
0
20 40 60 8085 100
-
-
40 20
Ambient Temperature
º C
Pin Out Specifications
Pin
1
2
Single
AC Input (N)
AC Input (L)
-V Output
Dual
AC Input (N)
AC Input (L)
-V Output
Common
3
4
5
No Connection
+V Output
+V Output
www.aimtec.com
F 052e R8.N
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEC15-MAZ
15 Watt | AC-DC Converter
Dimensions
2.56
2.56
(65.00)
(65.00)
1
2
AC Input
Connector
DIN Rail
Bracket
Mounting
Holes
(M3)
3.62
(92.00)
0.81
(20.50)
0.88
(22.30)
3.62
(92.00)
1.28
(32.50)
2.05
(52.10)
1.45
(36.70)
5 4 3
Top View
Bottom View
DC Output
Connector
Dimensions: inch (mm)
Case Tolerance: ±0.05 (±1.30)
PCB Mounting
Screw
PCB Mounting
Screw
PCB
Side View
Mylar Film
Bracket
Mountin
g Screw
PCB
Mylar Film
2.6 mm Max
Customer Chassis
www.aimtec.com
F 052e R8.N
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEC15-MAZ
15 Watt | AC-DC Converter
Mating Connectors with Wire (included)
DC Output Mating
Connector
200 ?0.5
Top
View
3 ?0.5
Side
View
AC Input Mating
Connector
Alternative
Connector Side
200 ?0.5
View
Top
View
3 ?0.5
Side
View
Alternative
Connector Side
View
Optional DIN Rail Bracket
NOTE: 1.Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8.N
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
相关型号:
©2020 ICPDF网 联系我们和版权申明