AMEC30-5DMAZ [AIMTEC]

30 Watt | AC/DC Converter; 30瓦| AC / DC转换器
AMEC30-5DMAZ
型号: AMEC30-5DMAZ
厂家: AIMTEC    AIMTEC
描述:

30 Watt | AC/DC Converter
30瓦| AC / DC转换器

转换器
文件: 总5页 (文件大小:508K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Series AMEC30-MAZ  
30 Watt | AC/DC Converter  
FEATURES:  
4000VAC I/O isolation  
Medical Switching power modules for PCB mounting  
Operating temperature: -40 to +85°C  
Energy star compliant  
RoHS compliant  
Low Ripple and Noise  
CE, cULus approvals  
Universal Input: 90-260VAC, 47-440Hz, or 120-370VDC  
CB  
Models  
Single output  
Output Current  
Input Voltage  
(VAC/Hz)  
Input Voltage  
Output Voltage  
(V)  
Efficiency  
(%)  
Model  
max  
(A)  
6
6
2.5  
2
(VDC)  
AMEC30-3.3SMAZ  
AMEC30-5SMAZ  
AMEC30-12SMAZ  
AMEC30-15SMAZ  
AMEC30-24SMAZ  
90-264/47-440  
90-264/47-440  
90-264/47-440  
90-264/47-440  
90-264/47-440  
120-370  
120-370  
120-370  
120-370  
120-370  
3.3  
5
12  
15  
24  
80  
83  
85  
85  
84  
1.25  
Models  
Dual output  
Output Current  
Input Voltage  
Input Voltage  
(VDC)  
Output Voltage  
(V)  
Efficiency  
(%)  
Model  
max  
(A)  
(VAC/Hz)  
AMEC30-5DMAZ  
AMEC30-12DMAZ  
AMEC30-15DMAZ  
AMEC30-24DMAZ  
90-264/47-440  
90-264/47-440  
90-264/47-440  
90-260/47-440  
120-370  
120-370  
120-370  
120-370  
±5  
±12  
±15  
±24  
±3  
±1.25  
±1  
81  
84  
83  
82  
±0.625  
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at  
rated output load unless otherwise specified.  
Input Specifications  
Parameters  
Conditions  
115 VAC  
230 VAC  
115 VAC  
230 VAC  
Typical  
Maximum  
Units  
740  
410  
25  
Current  
mA  
Inrush current <2ms  
A
50  
Leakage current  
External fuse  
µA  
A
150  
Recommended slow blow type  
No load; 115VAC  
3.15  
<0.5  
<0.8  
117  
Input dissipation  
Start-up time  
W
No load; 264VAC  
ms  
Output Specifications  
Parameters  
Voltage accuracy  
Line regulation  
Conditions  
Typical  
±2  
±0.5  
Maximum  
Units  
%
%
(LL-HL)  
0-100% load single  
0-100% load dual  
±1  
±2  
±5  
Load regulation  
%
Cross regulation  
25% load - 1st out, 100% load – 2nd out  
Depending of the model  
25% load Step  
%
µF  
% of Vout  
mV p-p  
ms  
Maximum Capacitive load  
Transient response deviation  
Ripple & Noise*  
Hold-up time (min)  
Minimum Load Current  
470-23 000  
±2  
50  
29  
0
20MHz bandwidth  
115VAC  
% of Max  
*Ripple & Noise measured with 0.1μF M/C and 1μF E/C  
www.aimtec.com  
F 052e R7.A  
Tel: +1 514 620 2722  
1 of 5  
Toll free: + 1 888 9 AIMTEC  
(924 6832)  
North America only  
Series AMEC30-MAZ  
30 Watt | AC/DC Converter  
Isolation Specifications  
Parameters  
Tested I/O voltage  
Input FG  
Output FG  
Conditions  
3 sec  
Typical  
4000  
1500  
1500  
>1000  
Maximum  
Units  
VAC  
VAC  
VAC  
M  
3 sec  
3 sec  
Isolation Resistance  
General Specifications  
Parameters  
Switching frequency  
Over current protection  
Over voltage protection  
Short circuit protection  
Short Circuit restart  
Operating temperature  
Maximum case temperature  
Storage temperature  
Temperature coefficient  
Cooling  
Conditions  
Typical  
47  
110  
Maximum  
Units  
KHz  
%
Auto recovery  
140  
110  
Zener diode clamp  
Hiccup mode, indefinite  
Auto recovery  
%
With derating above 55ºC  
Non condensing  
-40 - +85  
oC  
oC  
100  
95  
-40 to +95  
0.02  
Free air convection  
oC  
% / oC  
Humidity  
Case material  
Weight  
% RH  
g
Metal  
270  
Dimensions (L X H X W)  
MTBF  
4.92 x 2.56 x 1.38  
125 x 65 x 35mm  
> 800 000 hrs (MIL-HDBK -217F, t=+25oC)  
Environment Approval  
Test  
Parameters  
Conditions  
Wave form  
Half sine wave  
Acceleration amplitude  
Bump duration  
Converter operation  
Number of bumps  
Test mode  
Displacement  
Acceleration  
Converter operation  
5gn  
30 ms  
Shock  
Before and after test, body mounted (on chassis)  
18 (3 in each direction for every axis)  
Sweep sine, 10-100Hz, speed 0.05Hz/s  
1 mm  
3g, 3 loops 30min one cycle, 3h total, every axis tested  
Before and after test, body mounted (on chassis)  
Vibration  
Safety Specifications  
Parameters  
Agency approvals  
cULus, CE, CB Scheme  
EMI - Conducted and radiated emission  
EN55011, class B  
Medical Electrical Equipment  
Harmonic Current Emissions  
EN 60601-1, CSA-C22.2 No. 601.1-M90  
IEC/EN 61000-3-2, (EN60555-2)  
IEC/EN 61000-3-3, (EN60555-3)  
IEC 61000-4-2  
IEC 61000-4-3  
IEC 61000-4-4  
Voltage fluctuations and flicker  
Electrostatic Discharge Immunity  
RF, Electromagnetic Field Immunity  
Electrical Fast Transient/Burst Immunity  
Surge Immunity  
Standards  
IEC 61000-4-5  
RF, Conducted Disturbance Immunity  
Power frequency Magnetic Field Immunity  
Voltage dips, Short Interruptions Immunity  
IEC 61000-4-6  
IEC 61000-4-8  
IEC 61000-4-11  
www.aimtec.com  
F 052e R7.A  
Tel: +1 514 620 2722  
2 of 5  
Toll free: + 1 888 9 AIMTEC  
(924 6832)  
North America only  
Series AMEC30-MAZ  
30 Watt | AC/DC Converter  
Pin Out Specifications  
Pin  
1
2
3
4
Single  
AC Input (L)  
AC Input (N)  
+V Output  
-V Output  
N.C.  
Dual  
AC Input (L)  
AC Input (N)  
+V Output  
Common  
5
Common  
6
N.C.  
-V Output  
Dimensions  
www.aimtec.com  
F 052e R7.A  
Tel: +1 514 620 2722  
3 of 5  
Toll free: + 1 888 9 AIMTEC  
(924 6832)  
North America only  
Series AMEC30-MAZ  
30 Watt | AC/DC Converter  
Derating  
www.aimtec.com  
F 052e R7.A  
Tel: +1 514 620 2722  
4 of 5  
Toll free: + 1 888 9 AIMTEC  
(924 6832)  
North America only  
Series AMEC30-MAZ  
30 Watt | AC/DC Converter  
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled  
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the  
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,  
nominal input voltage and at rated output load unless otherwise specified.5..Aimtec may not have conducted destructive testing or chemical analysis on all internal components  
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This  
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate  
specific safety and regulatory standards other the ones listed in this datasheet.  
www.aimtec.com  
F 052e R7.A  
Tel: +1 514 620 2722  
5 of 5  
Toll free: + 1 888 9 AIMTEC  
(924 6832)  
North America only  

相关型号:

AMEC30-5SMAZ

30 Watt | AC/DC Converter
AIMTEC

AMEC30-MAZ

30 Watt | AC/DC Converter
AIMTEC

AMEC30-MAZ-1_16

30 Watt | AC-DC / DC-DC Converter
AIMTEC

AMEC30-MAZ_1

30 Watt | AC/DC Converter
AIMTEC

AMEC30-MAZ_12

30 Watt | AC-DC / DC-DC Converter
AIMTEC

AMEC30-MAZ_13

30 Watt | AC-DC / DC-DC Converter
AIMTEC

AMEC30-MAZ_16

30 Watt | AC-DC / DC-DC Converter
AIMTEC

AMEC40-12DMAZ

40 Watt | AC-DC Converter
AIMTEC

AMEC40-12SMAZ

40 Watt | AC-DC Converter
AIMTEC

AMEC40-15DMAZ

40 Watt | AC-DC Converter
AIMTEC

AMEC40-15SMAZ

40 Watt | AC-DC Converter
AIMTEC

AMEC40-24DMAZ

40 Watt | AC-DC Converter
AIMTEC