AMEL20-3.3SCJZ [AIMTEC]

AC-DC / DC-DC Converter;
AMEL20-3.3SCJZ
型号: AMEL20-3.3SCJZ
厂家: AIMTEC    AIMTEC
描述:

AC-DC / DC-DC Converter

光电二极管
文件: 总5页 (文件大小:622K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Click on Series name for product info on aimtec.com  
Series AMEL20-CJZ  
20 Watt | AC-DC / DC-DC Converter  
Picture Coming Soon  
FEATURES:  
I/O Isolation 4000VAC  
Low no load consumption ≤0.3W  
Continuous Short Circuit Protection  
Up to 83% efficiency  
Operating Temp: -40°C to +70°C  
Over current, Over Voltage Protection  
Input: 85-264VAC, 47-440Hz, or 100-370VDC  
Low ripple and noise  
Models  
Single output  
Maximum  
capacitive  
load  
Max  
Input  
Voltage  
(VDC)  
Output  
Voltage  
(V)  
Output  
Current  
max (A)  
Input Voltage  
Efficiency  
Output  
wattage  
(W)  
Model  
(VAC/Hz)  
(%)  
(µF)  
AMEL20-3.3SCJZ  
AMEL20-5SCJZ  
AMEL20-9SCJZ  
AMEL20-12SCJZ  
AMEL20-15SCJZ  
AMEL20-24SCJZ  
85-264/47-440  
85-264/47-440  
85-264/47-440  
85-264/47-440  
85-264/47-440  
85-264/47-440  
100-370  
100-370  
100-370  
100-370  
100-370  
100-370  
11.88  
18  
20  
20  
20  
3.3  
5
9
12  
15  
24  
3.6  
3.6  
2.2  
1.6  
1.3  
0.8  
10,000  
6600  
4400  
3000  
2000  
800  
74  
78  
79  
82  
83  
83  
20  
*Output power must not exceed the listed values.  
Note: Add suffix “-ST” for optional screw terminal bottom plate or “-STD” for optional DIN Rail screw terminal bottom plate. (ex. AMEL20-3.3SCJZ-ST,  
AMEL20-3.3SCJZ-STD).  
All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless  
otherwise specified.  
Input Specifications  
Parameters  
Conditions  
115VAC  
230VAC  
115VAC  
230VAC  
Typical  
0.37  
0.24  
12  
36  
3.15  
Maximum  
Units  
A
A
A
A
A
Current  
Inrush current <2ms (cold start)  
External fuse  
slow blow type  
Output Specifications  
Parameters  
Conditions  
3.3V output  
Others  
Typical  
±3  
Maximum  
Units  
Voltage accuracy  
%
±2  
Line regulation  
Load regulation  
Ripple & Noise  
Full load  
±0.5  
±1  
50  
10  
55  
%
%
mV p-p  
ms  
0%-100% load  
20MHz bandwidth  
115VAC  
120  
Hold up time  
230VAC  
ms  
Isolation Specifications  
Parameters  
Tested I/O voltage  
Isolation resistance  
Conditions  
Typical  
Rated  
4000  
Units  
VAC  
MΩ  
60 sec  
>1000  
General Specifications  
Parameters  
Switching frequency  
Protection class  
Over current protection  
Over voltage protection  
Short circuit protection  
Short circuit restart  
Conditions  
100% load  
Typical  
100  
Class II  
110  
Maximum  
Units  
KHz  
Auto recovery  
% of Iout  
Zener Diode Clamp  
Continuous  
Auto recovery  
-40 to +70  
Operating temperature  
Maximum case temperature  
See derating table  
oC  
oC  
100  
www.aimtec.com  
F 052e R8.D  
Tel: +1 514 620 2722  
1 of 5  
Toll free: + 1 888 9 AIMTEC (924 6832)  
North America only  
Series AMEL20-CJZ  
20 Watt | AC-DC / DC-DC Converter  
General Specifications (continued)  
Parameters  
Conditions  
Typical  
-40 to +85  
Maximum  
Units  
Storage temperature  
oC  
Temperature coefficient  
Cooling  
±0.02  
Free air convection  
% / oC  
Humidity  
Non condensing  
95  
% RH  
Case material  
Heat resistant black Plastic (flammability to UL 94V-0)  
PCB mountable models  
With optional -ST mounting plate:  
With optional -STD mounting plate:  
PCB mountable models  
With optional -ST mounting plate:  
With optional -STD mounting plate:  
60  
80  
100  
Weight  
g
2.11 x 1.13 x 0.92 inches (53.80 x 28.80 x 23.50mm)  
2.99 x 1.24 x 1.27 inches (76.00 x 31.50 x 32.30 mm)  
2.99 x 1.24 x 1.45 inches (76.00 x 31.50 x 36.90 mm)  
Dimensions (L x W x H)  
MTBF  
> 300 000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load  
Safety Specifications  
Parameters  
Information technology Equipment  
EMI - Conducted and radiated emission  
Electrostatic Discharge Immunity  
RF, Electromagnetic Field Immunity  
Electrical Fast Transient/Burst Immunity  
Surge Immunity  
RF, Conducted Disturbance Immunity  
Power frequency Magnetic Field Immunity  
Voltage dips, Short Interruptions Immunity  
Meets IEC/EN/UL 62368-1  
EN55032, class B  
IEC 61000-4-2 Level 3  
IEC 61000-4-3 Level 3  
IEC 61000-4-4 Level 4  
IEC 61000-4-5 Level 3  
IEC 61000-4-6 Level 3  
IEC 61000-4-8 Level 3  
IEC 61000-4-11 Class 2  
Standards  
Pin Out Specifications  
Dimensions  
Pin  
1
2
3
Single  
AC Input (N)  
AC Input (L)  
+V Output  
-V Output  
53.80  
(2.12)  
Case Temperature  
Measurement point  
45.72  
(1.80)  
1
2
3
4
1
2
3
TOP VIEW  
+
10.16  
(0.40)  
4
28.80  
(1.13)  
20.32  
(0.80)  
TOP VIEW  
4
5
23.50  
(0.93)  
DIV: 5.08 (0.2)  
Ø 1.5 (Ø 0.06)  
Dimensions mm (inch)  
Ø 1.00  
(0.04)  
Case Tolerance ±0.50 (±0.02)  
Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004)  
Pin Pitch Tolerance ±0.35 (±0.014)  
www.aimtec.com  
F 052e R8.D  
Tel: +1 514 620 2722  
2 of 5  
Toll free: + 1 888 9 AIMTEC (924 6832)  
North America only  
Series AMEL20-CJZ  
20 Watt | AC-DC / DC-DC Converter  
With optional -ST bottom plate  
76.00  
(2.99)  
61.60  
(2.43)  
Pin Out Specifications  
LED light  
Pin  
1
Single  
AC Input (N)  
AC Input (L)  
+V Output  
-V Output  
2
3
4
3
4
1
Top view  
2
Ø3.30  
Ø0.13  
Side view  
Dimensions: mm (inch)  
Case Tolerance:± 0.50 (0.02)  
Wire gauge: 24-12AWG  
With optional -STD bottom plate  
76.00  
(2.99)  
61.60  
(2.43)  
Pin Out Specifications  
LED light  
Pin  
1
2
3
4
Single  
AC Input (N)  
AC Input (L)  
+V Output  
-V Output  
3
4
1
2
Top view  
Side view  
Dimensions: mm (inch)  
Case Tolerance:± 0.50 (0.02)  
Wire gauge: 24-12AWG  
www.aimtec.com  
F 052e R8.D  
Tel: +1 514 620 2722  
3 of 5  
Toll free: + 1 888 9 AIMTEC (924 6832)  
North America only  
Series AMEL20-CJZ  
20 Watt | AC-DC / DC-DC Converter  
Derating for AMEL20-3.3SCJZ and AMEL20-5SCJZ  
Free Air Convection  
Free Air Convection at 25°C  
100  
100  
80  
75  
80  
70  
Safe Operating Area  
Input Voltage Range  
60  
60  
100-370 VDC  
85-370 VAC  
40  
33  
40  
20  
20  
0
0
85  
(100)  
130  
(160)  
240  
(340)  
264  
(370)  
70  
80  
100  
- 40 -25  
0
20  
40  
60  
º C  
Ambient Temperature  
Input Voltage VAC (VDC)  
Derating for all other part numbers  
Free Air Convection at 25°C  
Free Air Convection  
100  
100  
80  
80  
70  
Safe Operating Area  
120-340 VDC  
75  
Safe Operating Area  
60  
60  
100-240 VAC  
40  
40  
33  
30  
20  
0
20  
0
85  
100  
240  
(340)  
264  
(370)  
70  
80  
100  
- 40 -25  
0
20  
40  
60  
(100) (120)  
Input Voltage VAC (VDC)  
º C  
Ambient Temperature  
Typical application circuit  
Single Output  
FUSE  
3.15A/250V  
AC L  
4
3
+ Vout  
AC L  
+
MOV  
S20K300  
AC  
DC  
C1  
1µF/50V  
C2  
TVS  
AC N  
AC N  
- Vout  
Model  
3.3 & 5 Vout  
9 Vout  
12 & 15 Vout  
24 Vout  
C2  
TVS  
7V  
12V  
20V  
30V  
220 µF / 16V  
120 µF / 25V  
120 µF / 25V  
68 µF / 35V  
www.aimtec.com  
F 052e R8.D  
Tel: +1 514 620 2722  
4 of 5  
Toll free: + 1 888 9 AIMTEC (924 6832)  
North America only  
Series AMEL20-CJZ  
20 Watt | AC-DC / DC-DC Converter  
To meet surge Immunity ±4KV/±6KV recommended circuit  
Single Output  
LCM  
2mH  
LDM  
4.7µH  
FUSE  
3.15A/250V  
+Vout  
+Vout  
AC L  
AC N  
C1in  
1nF/  
400VAC  
MOV  
S10K300  
TVS  
C2in  
1nF/  
400VAC  
CX  
0.22µF/  
275VAC  
R
+
C2  
1µF/50V  
MOV  
S20K300  
GDT  
AC  
DC  
C1  
1MΩ/2W  
MOV  
S10K300  
AC L  
AC N  
- Vout  
GND  
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled  
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the  
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,  
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components  
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This  
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate  
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.  
www.aimtec.com  
F 052e R8.D  
Tel: +1 514 620 2722  
5 of 5  
Toll free: + 1 888 9 AIMTEC (924 6832)  
North America only  

相关型号:

AMEL20-3.3SMAZ

20 Watt | AC-DC Converter
AIMTEC

AMEL20-3.3SMAZ-ST

AC/DC Converter; Product Weight (grams): 70; Input voltage min (V): 90; Input voltage max (V): 264; Input frequency (Hz): 47-440; Output voltage min: 3.3; Output voltage max: 3.3; Output voltage dual assymetric (y/n): Single; Output Power (W): 20; Max Output current (A): 4; Efficiency (%): 73; Max Capacitive load (µF): 5600; Package type: Encapsulated; Mounting: Screw terminal; W (in): 1.21; L (in): 2.22; H (in): 0.99; W (mm): 30.86; L (mm): 56.48; H (mm): 25.1; Min Operating temperature: -40; Max operating temperature (°C): 70; Isolation (VAC): 4000; EMC compliance 1: EN 55022 Class B; Case
AIMTEC

AMEL20-512DMAZ

20 Watt | AC-DC Converter
AIMTEC

AMEL20-512DMAZ-ST

AC/DC Converter; Product Weight (grams): 70; Input voltage min (V): 90; Input voltage max (V): 264; Input frequency (Hz): 47-440; Output voltage min: 5; Output voltage max: 5; Output voltage dual assymetric (y/n): Asymmetric Dual; Output Power (W): 20; Max Output current (A): 1.6/0.83; Efficiency (%): 77; Max Capacitive load (µF): 680; Package type: Encapsulated; Mounting: Screw terminal; W (in): 1.21; L (in): 2.22; H (in): 0.99; W (mm): 30.86; L (mm): 56.48; H (mm): 25.1; Min Operating temperature: -40; Max operating temperature (°C): 70; Isolation (VAC): 4000; EMC compliance 1: EN 55022 Cla
AIMTEC

AMEL20-515DMAZ

20 Watt | AC-DC Converter
AIMTEC

AMEL20-515DMAZ-ST

AC/DC Converter; Product Weight (grams): 70; Input voltage min (V): 90; Input voltage max (V): 264; Input frequency (Hz): 47-440; Output voltage min: 5; Output voltage max: 5; Output voltage dual assymetric (y/n): Asymmetric Dual; Output Power (W): 20; Max Output current (A): 1.6/0.66; Efficiency (%): 79; Max Capacitive load (µF): 680; Package type: Encapsulated; Mounting: Screw terminal; W (in): 1.21; L (in): 2.22; H (in): 0.99; W (mm): 30.86; L (mm): 56.48; H (mm): 25.1; Min Operating temperature: -40; Max operating temperature (°C): 70; Isolation (VAC): 4000; EMC compliance 1: EN 55022 Cla
AIMTEC

AMEL20-524DMAZ

20 Watt | AC-DC Converter
AIMTEC

AMEL20-5N12DMAZ

20 Watt | AC-DC Converter
AIMTEC

AMEL20-5N15DMAZ

20 Watt | AC-DC Converter
AIMTEC

AMEL20-5N5DMAZ

20 Watt | AC-DC Converter
AIMTEC

AMEL20-5SAZ

20 Watt | AC-DC Converter
AIMTEC

AMEL20-5SCJZ

AC-DC / DC-DC Converter
AIMTEC