AMEL20-3.3SCJZ [AIMTEC]
AC-DC / DC-DC Converter;型号: | AMEL20-3.3SCJZ |
厂家: | AIMTEC |
描述: | AC-DC / DC-DC Converter 光电二极管 |
文件: | 总5页 (文件大小:622K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Click on Series name for product info on aimtec.com
Series AMEL20-CJZ
20 Watt | AC-DC / DC-DC Converter
Picture Coming Soon
FEATURES:
•
I/O Isolation 4000VAC
•
•
•
•
Low no load consumption ≤0.3W
Continuous Short Circuit Protection
Up to 83% efficiency
• Operating Temp: -40°C to +70°C
• Over current, Over Voltage Protection
•
Input: 85-264VAC, 47-440Hz, or 100-370VDC
Low ripple and noise
Models
Single output
Maximum
capacitive
load
Max
Input
Voltage
(VDC)
Output
Voltage
(V)
Output
Current
max (A)
Input Voltage
Efficiency
Output
wattage
(W)
Model
(VAC/Hz)
(%)
(µF)
AMEL20-3.3SCJZ
AMEL20-5SCJZ
AMEL20-9SCJZ
AMEL20-12SCJZ
AMEL20-15SCJZ
AMEL20-24SCJZ
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
100-370
100-370
100-370
100-370
100-370
100-370
11.88
18
20
20
20
3.3
5
9
12
15
24
3.6
3.6
2.2
1.6
1.3
0.8
10,000
6600
4400
3000
2000
800
74
78
79
82
83
83
20
*Output power must not exceed the listed values.
Note: Add suffix “-ST” for optional screw terminal bottom plate or “-STD” for optional DIN Rail screw terminal bottom plate. (ex. AMEL20-3.3SCJZ-ST,
AMEL20-3.3SCJZ-STD).
All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless
otherwise specified.
Input Specifications
Parameters
Conditions
115VAC
230VAC
115VAC
230VAC
Typical
0.37
0.24
12
36
3.15
Maximum
Units
A
A
A
A
A
Current
Inrush current <2ms (cold start)
External fuse
slow blow type
Output Specifications
Parameters
Conditions
3.3V output
Others
Typical
±3
Maximum
Units
Voltage accuracy
%
±2
Line regulation
Load regulation
Ripple & Noise
Full load
±0.5
±1
50
10
55
%
%
mV p-p
ms
0%-100% load
20MHz bandwidth
115VAC
120
Hold up time
230VAC
ms
Isolation Specifications
Parameters
Tested I/O voltage
Isolation resistance
Conditions
Typical
Rated
4000
Units
VAC
MΩ
60 sec
>1000
General Specifications
Parameters
Switching frequency
Protection class
Over current protection
Over voltage protection
Short circuit protection
Short circuit restart
Conditions
100% load
Typical
100
Class II
≥110
Maximum
Units
KHz
Auto recovery
% of Iout
Zener Diode Clamp
Continuous
Auto recovery
-40 to +70
Operating temperature
Maximum case temperature
See derating table
oC
oC
100
www.aimtec.com
F 052e R8.D
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEL20-CJZ
20 Watt | AC-DC / DC-DC Converter
General Specifications (continued)
Parameters
Conditions
Typical
-40 to +85
Maximum
Units
Storage temperature
oC
Temperature coefficient
Cooling
±0.02
Free air convection
% / oC
Humidity
Non condensing
95
% RH
Case material
Heat resistant black Plastic (flammability to UL 94V-0)
PCB mountable models
With optional -ST mounting plate:
With optional -STD mounting plate:
PCB mountable models
With optional -ST mounting plate:
With optional -STD mounting plate:
60
80
100
Weight
g
2.11 x 1.13 x 0.92 inches (53.80 x 28.80 x 23.50mm)
2.99 x 1.24 x 1.27 inches (76.00 x 31.50 x 32.30 mm)
2.99 x 1.24 x 1.45 inches (76.00 x 31.50 x 36.90 mm)
Dimensions (L x W x H)
MTBF
> 300 000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
Safety Specifications
Parameters
Information technology Equipment
EMI - Conducted and radiated emission
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Meets IEC/EN/UL 62368-1
EN55032, class B
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 3
IEC 61000-4-4 Level 4
IEC 61000-4-5 Level 3
IEC 61000-4-6 Level 3
IEC 61000-4-8 Level 3
IEC 61000-4-11 Class 2
Standards
Pin Out Specifications
Dimensions
Pin
1
2
3
Single
AC Input (N)
AC Input (L)
+V Output
-V Output
53.80
(2.12)
Case Temperature
Measurement point
45.72
(1.80)
1
2
3
4
1
2
3
TOP VIEW
+
10.16
(0.40)
4
28.80
(1.13)
20.32
(0.80)
TOP VIEW
4
5
23.50
(0.93)
DIV: 5.08 (0.2)
Ø 1.5 (Ø 0.06)
Dimensions mm (inch)
Ø 1.00
(0.04)
Case Tolerance ±0.50 (±0.02)
Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004)
Pin Pitch Tolerance ±0.35 (±0.014)
www.aimtec.com
F 052e R8.D
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEL20-CJZ
20 Watt | AC-DC / DC-DC Converter
With optional -ST bottom plate
76.00
(2.99)
61.60
(2.43)
Pin Out Specifications
LED light
Pin
1
Single
AC Input (N)
AC Input (L)
+V Output
-V Output
2
3
4
3
4
1
Top view
2
Ø3.30
Ø0.13
Side view
Dimensions: mm (inch)
Case Tolerance:± 0.50 (0.02)
Wire gauge: 24-12AWG
With optional -STD bottom plate
76.00
(2.99)
61.60
(2.43)
Pin Out Specifications
LED light
Pin
1
2
3
4
Single
AC Input (N)
AC Input (L)
+V Output
-V Output
3
4
1
2
Top view
Side view
Dimensions: mm (inch)
Case Tolerance:± 0.50 (0.02)
Wire gauge: 24-12AWG
www.aimtec.com
F 052e R8.D
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEL20-CJZ
20 Watt | AC-DC / DC-DC Converter
Derating for AMEL20-3.3SCJZ and AMEL20-5SCJZ
Free Air Convection
Free Air Convection at 25°C
100
100
80
75
80
70
Safe Operating Area
Input Voltage Range
60
60
100-370 VDC
85-370 VAC
40
33
40
20
20
0
0
85
(100)
130
(160)
240
(340)
264
(370)
70
80
100
- 40 -25
0
20
40
60
º C
Ambient Temperature
Input Voltage VAC (VDC)
Derating for all other part numbers
Free Air Convection at 25°C
Free Air Convection
100
100
80
80
70
Safe Operating Area
120-340 VDC
75
Safe Operating Area
60
60
100-240 VAC
40
40
33
30
20
0
20
0
85
100
240
(340)
264
(370)
70
80
100
- 40 -25
0
20
40
60
(100) (120)
Input Voltage VAC (VDC)
º C
Ambient Temperature
Typical application circuit
Single Output
FUSE
3.15A/250V
AC L
4
3
+ Vout
AC L
+
MOV
S20K300
AC
DC
C1
1µF/50V
C2
TVS
AC N
AC N
- Vout
Model
3.3 & 5 Vout
9 Vout
12 & 15 Vout
24 Vout
C2
TVS
7V
12V
20V
30V
220 µF / 16V
120 µF / 25V
120 µF / 25V
68 µF / 35V
www.aimtec.com
F 052e R8.D
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEL20-CJZ
20 Watt | AC-DC / DC-DC Converter
To meet surge Immunity ±4KV/±6KV recommended circuit
Single Output
LCM
2mH
LDM
4.7µH
FUSE
3.15A/250V
+Vout
+Vout
AC L
AC N
C1in
1nF/
400VAC
MOV
S10K300
TVS
C2in
1nF/
400VAC
CX
0.22µF/
275VAC
R
+
C2
1µF/50V
MOV
S20K300
GDT
AC
DC
C1
1MΩ/2W
MOV
S10K300
AC L
AC N
- Vout
GND
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8.D
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
相关型号:
AMEL20-3.3SMAZ-ST
AC/DC Converter; Product Weight (grams): 70; Input voltage min (V): 90; Input voltage max (V): 264; Input frequency (Hz): 47-440; Output voltage min: 3.3; Output voltage max: 3.3; Output voltage dual assymetric (y/n): Single; Output Power (W): 20; Max Output current (A): 4; Efficiency (%): 73; Max Capacitive load (µF): 5600; Package type: Encapsulated; Mounting: Screw terminal; W (in): 1.21; L (in): 2.22; H (in): 0.99; W (mm): 30.86; L (mm): 56.48; H (mm): 25.1; Min Operating temperature: -40; Max operating temperature (°C): 70; Isolation (VAC): 4000; EMC compliance 1: EN 55022 Class B; Case
AIMTEC
AMEL20-512DMAZ-ST
AC/DC Converter; Product Weight (grams): 70; Input voltage min (V): 90; Input voltage max (V): 264; Input frequency (Hz): 47-440; Output voltage min: 5; Output voltage max: 5; Output voltage dual assymetric (y/n): Asymmetric Dual; Output Power (W): 20; Max Output current (A): 1.6/0.83; Efficiency (%): 77; Max Capacitive load (µF): 680; Package type: Encapsulated; Mounting: Screw terminal; W (in): 1.21; L (in): 2.22; H (in): 0.99; W (mm): 30.86; L (mm): 56.48; H (mm): 25.1; Min Operating temperature: -40; Max operating temperature (°C): 70; Isolation (VAC): 4000; EMC compliance 1: EN 55022 Cla
AIMTEC
AMEL20-515DMAZ-ST
AC/DC Converter; Product Weight (grams): 70; Input voltage min (V): 90; Input voltage max (V): 264; Input frequency (Hz): 47-440; Output voltage min: 5; Output voltage max: 5; Output voltage dual assymetric (y/n): Asymmetric Dual; Output Power (W): 20; Max Output current (A): 1.6/0.66; Efficiency (%): 79; Max Capacitive load (µF): 680; Package type: Encapsulated; Mounting: Screw terminal; W (in): 1.21; L (in): 2.22; H (in): 0.99; W (mm): 30.86; L (mm): 56.48; H (mm): 25.1; Min Operating temperature: -40; Max operating temperature (°C): 70; Isolation (VAC): 4000; EMC compliance 1: EN 55022 Cla
AIMTEC
©2020 ICPDF网 联系我们和版权申明