AMEL5-VZ [AIMTEC]
AC-DC Converter;Click on Series name for product info on aimtec.com
Series AMEL5-VZ
5 Watt | AC-DC Converter
FEATURES:
• I/O Isolation 4000VAC
• High efficiency up to 81%
• Regulated Output
• Ultra-small package
• Short Circuit Protection
• Operating Temp: -40 °C to +70 °C
• Input: 85-264VAC, 47-63Hz, or 100-370VDC
• Over current, Over Voltage Protection
Picture Coming soon
Models
Single output
Efficiency
(%)
Maximum
capacitive
Load
(µF)
Output
Voltage
(V)
Output
Current max
(A)
Input Voltage
Input Voltage
(VDC)
Model
(VAC/Hz)
230
VAC
AMEL5-3.3SVZ
AMEL5-5SVZ
AMEL5-9SVZ
AMEL5-12SVZ
AMEL5-15SVZ
AMEL5-24SVZ
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
100-370
100-370
100-370
100-370
100-370
100-370
3.3
5
9
12
15
24
1
1
0.56
0.42
0.33
0.24
5000
5000
1200
1200
1000
330
68
75
77
79
79
81
Add suffix “-W” for optional wire output terminal.
Input Specifications
Parameters
Conditions
115 VAC
230 VAC
115 VAC
Minimum
Typical
Maximum
130
Units
mA
mA
A
A
A
mA
V
V
Current (full load)
70
10
20
1
Inrush current <2ms (cold
start)
External fuse
230 VAC
Recommended slow blow type
230VAC/50Hz
VAC
Leakage Current
0.1
264
370
85
100
Input Voltage
VDC
Output Specifications
Parameters
Conditions
3.3V output
Typical
±3
Maximum
Units
Voltage accuracy
%
Others
±2
Line regulation
Load regulation
Ripple & Noise*
Full Load
±0.5
±1
50
5
50
%
%
mV p-p
0%-100% load
20MHz Bandwidth, others
115VAC
100
Hold-up time (minimum)
ms
230VAC
*Ripple and Noise are measured at 20MHz bandwidth by using the referenced Application circuit.
Isolation Specifications
Parameters
Conditions
Typical
4000
>1000
Rated
Units
VAC
MΩ
Tested I/O voltage
Isolation Resistance
60 sec
General Specifications
Parameters
Switching frequency
Protection class
Over Current protection
Over voltage protection
Short circuit protection
Operating temperature
Storage temperature
Conditions
Auto recovery
Typical
100
Class II
Maximum
Units
KHz
≥120
% of Iout
Zener diode clamp
Continuous, hiccup, Auto recovery
See derating curve
-40 to 70°C
-40 to +105
°C
°C
www.aimtec.com
F 052e R8.D
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEL5-VZ
5 Watt | AC-DC Converter
Temperature coefficient
Cooling
0.02
% /°C
Free air convection
Case material
Weight
Plastic (flammability to UL 94V-0)
25
g
Dimensions (L x W x H)
MTBF
1.46 x 0.96 x 0.71 (37.00 x 24.50 x 18.00mm)
> 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Safety Specifications
Parameters
Agency approvals Designed to meet UL62368
Designed to meet IEC/EN/UL 62368-1
EMI - Conducted and radiated emission
EN55032, class A
EN55032, class B with EMC recommended circuit
IEC 61000-4-2, Contact: ±6KV/Air: ±8KV, Criteria B
IEC 61000-4-3, 10V/m, Criteria A
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Standards
IEC 61000-4-4, ±2KV, Criteria B
IEC 61000-4-4, ±4KV, Criteria B with EMC recommended circuit
IEC 61000-4-5, ±1KV Criteria B
Surge Immunity
IEC 61000-4-5, ±2KV, Criteria B with EMC recommended circuit
IEC 61000-4-6, 10Vrms, Criteria A
RF, Conducted Disturbance Immunity
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11, 0-70%, Criteria B
Dimensions
30.48
(1.20)
37.00
(1.46)
0.60
(0.02)
3
1
13
Bottom View
16 14
5.08
(0.20)
Printed Face
All dimensions are typical: millimeters (inches)
Pin Diameter: 0.60 ± 0.10 (0.02 ± 0.004)
Pin Pitch Tolerance: ± 0.35 (±0.014)
Case Tolerance: ± 0.5 (±0.02)
Pin Out Specifications
Pin
Single
AC Input (L)
AC Input (N)
NC
-V Output
+V Output
1
3
13
14
16
www.aimtec.com
F 052e R8.D
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEL5-VZ
5 Watt | AC-DC Converter
Dimensions with -W options
37.00
(1.46)
30.48
(1.20)
1
3
13
14
Bottom View
16
37.00
(1.46)
Wire is UL 1015/CSATEM listed #22AWG
Wire Tolerance: ±0.30[±0.012]
Pin Out Specifications
Pin
Single
AC Input (L)
AC Input (N)
NC
1 brown
3 blue
13
14 black
16 red
-V Output
+V Output
www.aimtec.com
F 052e R8.D
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEL5-VZ
5 Watt | AC-DC Converter
Derating
Free Air Convection at 25°C
Free Air Convection
100
100
85
80
80
70
Safe Operating Area
Input 85-264VAC or
100-370VDC
Safe Operating Area
60
40
60
55
40
20
20
0
85
(100)
100
(120)
264
(370)
0
70
5560
º C
80
- 25
-10
-
40
-
20
0
20
40
Input Voltage VAC (VDC)
Ambient Temperature
Typical application circuit
Single Output
FUSE
1A/250V
+ Vout
DC
+ Vout
- Vout
AC L
AC L
Model
C2
TVS
7V
12V
TVS
3.3 & 5 Vout
9Vout
150 µF / 35V
120 µF / 35V
+
MOV
S14K350
AC
C1
1µF/50V
C2
AC N
12 & 15 Vout
24 Vout
120 µF / 35V
68 µF / 35V
20V
30V
AC N
- Vout
EMC recommended circuit
Single Output
LCM
10-30mH
LDM
330µH/2A
FUSE
2A/250V
R
33Ω/3W
+Vout
+Vout
AC L
AC N
CY1
1nF/
TVS
400VAC
C2
+
CX
0.1µF/
275VAC
MOV
S14K350
AC
DC
C1
1µF/50V
CY2
1nF/
400VAC
AC N
GND
AC L
- Vout
- Vout
Model
C2
TVS
3.3 & 5 Vout
9Vout
12 & 15 Vout
24 Vout
150 µF / 35V
120 µF / 35V
120 µF / 35V
68 µF / 35V
7V
12V
20V
30V
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8.D
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
相关型号:
AMEM5-24SY
AC/DC Converter; Product Weight (grams): 18.5; Input voltage min (V): 85; Input voltage max (V): 264; Input frequency (Hz): 47-63; Output voltage min: 24; Output voltage max: 24; Output voltage dual assymetric (y/n): Single; Output Power (W): 5; Max Output current (A): 0.2; Efficiency (%): 78; Max Capacitive load (µF): 300; Package type: 1x1; Mounting: PCB; W (in): 1; L (in): 1; H (in): 0.6; W (mm): 25.4; L (mm): 25.4; H (mm): 15.2; Min Operating temperature: -25; Max operating temperature (°C): 70; Isolation (VAC): 4000; EMC compliance 1: EN 55032 Class B; EMC compliance 2: CISPR32 FCC part
AIMTEC
AMEM5-48SY
AC/DC Converter; Product Weight (grams): 18.5; Input voltage min (V): 85; Input voltage max (V): 264; Input frequency (Hz): 47-63; Output voltage min: 48; Output voltage max: 48; Output voltage dual assymetric (y/n): Single; Output Power (W): 5; Max Output current (A): 0.1; Efficiency (%): 78; Max Capacitive load (µF): 100; Package type: 1x1; Mounting: PCB; W (in): 1; L (in): 1; H (in): 0.6; W (mm): 25.4; L (mm): 25.4; H (mm): 15.2; Min Operating temperature: -25; Max operating temperature (°C): 70; Isolation (VAC): 4000; EMC compliance 1: EN 55032 Class B; EMC compliance 2: CISPR32 FCC part
AIMTEC
AMEM5-5SY
AC/DC Converter; Product Weight (grams): 18.5; Input voltage min (V): 85; Input voltage max (V): 264; Input frequency (Hz): 47-63; Output voltage min: 5; Output voltage max: 5; Output voltage dual assymetric (y/n): Single; Output Power (W): 5; Max Output current (A): 1; Efficiency (%): 74; Max Capacitive load (µF): 7200; Package type: 1x1; Mounting: PCB; W (in): 1; L (in): 1; H (in): 0.6; W (mm): 25.4; L (mm): 25.4; H (mm): 15.2; Min Operating temperature: -25; Max operating temperature (°C): 70; Isolation (VAC): 4000; EMC compliance 1: EN 55032 Class B; EMC compliance 2: CISPR32 FCC part 15;
AIMTEC
©2020 ICPDF网 联系我们和版权申明