AMEOF3-JZ [AIMTEC]
Continuous short circuit protection;型号: | AMEOF3-JZ |
厂家: | AIMTEC |
描述: | Continuous short circuit protection |
文件: | 总4页 (文件大小:169K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series AMEOF3-JZ
3 Watt | AC-DC Converter
Picture Coming Soon
FEATURES:
• Input: 85-264VAC, 47-440Hz or 70-400VDC
• Operating temperature -40°C to +85°C
• Low power consumption ≤ 0.5W
•
•
•
•
I/O Isolation 3000VAC
Ultra slim open frame SIP
Over current protection
Class II power supply
• Continuous short circuit protection
Models
Single output
Full power
temperature
range
Maximum
Input
Voltage
(VDC)
Output
Voltage
(V)
Output
Current max
(mA)
Input Voltage
capacitive
load
(µF)
470
Efficiency
(%)
Model
(VAC/Hz)
(ºC)
AMEOF3-3.3SJZ
AMEOF3-5SJZ
AMEOF3-9SJZ
AMEOF3-12SJZ
AMEOF3-15SJZ
AMEOF3-24SJZ
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
70-400
70-400
70-400
70-400
70-400
70-400
-20 to +55
-20 to +55
-20 to +55
-20 to +55
-20 to +55
-20 to +55
3.3
5
9
12
15
24
500
500
333
250
200
125
63
68
75
77
78
80
470
150
100
100
100
AMEOF3-3.3SLJZ
AMEOF3-5SLJZ
AMEOF3-9SLJZ
AMEOF3-12SLJZ
AMEOF3-15SLJZ
AMEOF3-24SLJZ
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
70-400
70-400
70-400
70-400
70-400
70-400
-20 to +55
-20 to +55
-20 to +55
-20 to +55
-20 to +55
-20 to +55
3.3
5
9
12
15
24
500
500
333
250
200
125
470
470
150
100
100
100
63
68
75
77
78
80
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Conditions
115VAC
230VAC
115VAC
230VAC
Typical
Maximum
Units
mA
mA
A
A
A
120
60
Current
13
23
1
Inrush current <2ms
External fuse
Input dissipation
Input filter
Recommended slow blow type
No Load
0.5
W
Recommended external π (Pi) filter
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Full load, 3.3V output
Full load, others
Full load
10% - 100% load
20MHz Bandwidth
±8
±5
Voltage accuracy
%
Line regulation
Load regulation
Ripple & Noise
±1.5
±2.5
%
%
150
mV p-p
% of Max
Minimum load current
10
Isolation Specifications
Parameters
Tested I/O voltage
Conditions
Typical
Rated
3000
Units
VAC
MΩ
60 sec
Isolation Resistance
>1000
www.aimtec.com
F 052e R0
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEOF3-JZ
3 Watt | AC-DC Converter
General Specifications
Parameters
Switching frequency
Over current protection
Short circuit protection
Short circuit restart
Operating temperature
Storage temperature
Temperature coefficient
Conditions
Typical
60
≥110
Continuous
Auto-recovery
-40 to +85
-40 to +105
±0.15
Maximum
Units
KHz
% of I out
Auto-recovery
See derating curve
°C
°C
% / °C
Cooling
Free air convection
Humidity
Weight
85
% RH
g
7
Dimensions (L x W x H)
MTBF
1.38 x 0.71 x 0.43 inches
35 x 18 x 11 mm
>300,000 hours (MIL-HDBK -217F, Ground Benign, t=+25oC)
Safety Specifications
Parameters
IEC/EN/UL60950-1 pending approval
EN 55022, Class A & B, with external filter circuits, as referenced
IEC 61000-4-2, Contact ±4KV, Criteria B
IEC 61000-4-3, 10V/m, Criteria A, with Class B external filter, as referenced
IEC 61000-4-4, ±2KV/±4KV, Criteria B, with Class A/B external filter referenced
IEC 61000-4-5, ±1KV/±2KV, Criteria B, with Class A/B external filter referenced
IEC 61000-4-6, 10Vrms, Criteria A, with Class B external filter, as referenced
IEC 61000-4-8, 10A/m, Criteria A, with Class B external filter, as referenced
IEC 61000-4-11, 0-70%, Criteria B, with Class B external filter, as referenced
Standards
Pin Out Specifications*
Dimensions
35.00
(1.38)
Single
Pin
1
AC N
AC L
3
5
+V sc
7
-V sc
10
12
-V Output
+V Output
* Add capacitor between pin 5 & 7.
Application circuit below.
1
5
7
10
12
3
1.30
(0.05)
5.08
(0.20)
Note:
Unit: mm (inch)
27.94
(1.10)
Pin diameter tolerance: ±0.10 (±0.004)
Case tolerance: ±0.50 (±0.02)
www.aimtec.com
F 052e R0
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEOF3-JZ
3 Watt | AC-DC Converter
L models
35.00
(1.38)
Top view
Note:
Unit: mm (inch)
Pin diameter tolerance: ±0.10 (±0.004)
Case tolerance: ±0.50 (±0.02)
1
5
7
10
12
3
1.30
(0.05)
Right view
Front view
1.60
(0.06)
5.08
(0.20)
0.40
(0.02)
0.80
(0.03)
27.94
(1.10)
Derating*
Free Air Convection at 25°C
Free Air Convection
100
80
100
80
Safe Operating Area
100% load 110-240VAC
Or 100-340VDC
Safe Operating Area
60
40
60
40
20
0
20
0
55
85
85
110
240
264
80
100
- 40 - 20
0
20
40
60
(70) (100)
(340)
(400)
º C
Ambient Temperature
Input Voltage VAC (VDC)
*Power derating: -40 to -20 increase 1%/°C
55 to 85 decrease 0.67%/°C
www.aimtec.com
F 052e R0
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEOF3-JZ
3 Watt | AC-DC Converter
Recommended EMC class A external circuit:
Single Output
L2
2.2µH
FUSE
1A/250V
L1
4.7mH
NTC
+Vout
- Vout
12
10
AC L
3
5
+
TVS
C3
+
C2
+
C1
10µF/450V
MOV
S14K350
AC
DC
C4
0.1µF/50V
7
AC N
1
Pi filter
CY1
1nF/400VAC
Recommended EMC class B external circuit:
Single Output
L2
2.2µH
FUSE
1A/250V
LDM
0.33mH
LCM
3.5mH
NTC
+Vout
12
AC L
3
5
CY2
1nF/
400VAC
+
TVS
CX
0.1µF/
275VAC
C1
4.7µF/
450V
+
C2
C3
+
MOV
S14K350
AC
DC
C4
CY3
1nF/
400VAC
0.1µF/50V
7
AC N
GND
1
10
- Vout
Pi filter
CY1
1nF/400VAC
Model
3.3 Vout
5 Vout
9 Vout
12 & 15
Vout
C2
C3
TVS
120 µF / 25V
7V
330 µF /
25V
12V
20V
150 µF /
35V
100 µF /
35V
68 µF / 35V
Note: For Safety compliance we recommend minimum
PCB trace distance of 3mm, minimum distance between
PCB traces of 6mm, primary to secondary circuit traces
distance between minimum of 6.4mm.
24 Vout
30V
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R0
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
相关型号:
©2020 ICPDF网 联系我们和版权申明