AMER120-42250Z [AIMTEC]
up to 3000mA | AC-DC LED driver;型号: | AMER120-42250Z |
厂家: | AIMTEC |
描述: | up to 3000mA | AC-DC LED driver |
文件: | 总5页 (文件大小:436K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series AMER120-Z
up to 3000mA | AC-DC LED driver
FEATURES:
• Accurate Constant Current Output ±5%
•
•
•
•
IP65/IP67 design for indoor/outdoor
Long Life, High reliability
Over Temperature Protection
Open Circuit Protection
• High Efficiency: Up to 88%
• Active Power Factor Correction
• UVLO, Short Circuit Protection
Models
Single output
Max Output
Power (W)
105
Output Voltage
Range (V)
24-42
Output Current
(A)
2.5
Input Voltage
(VAC/Hz)
90-305/47-63
Efficiency
Model
(%)
88
87
AMER120-42250Z
AMER120-42300Z
126
24-42
3
90-305/47-63
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity <75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Input Current
Conditions
Typical
Maximum
1.6
40
65
0.75
1.5
Units
Arms
90 VAC, full load
115 VAC, cold start
305 VAC, cold start
Inrush current <2ms
A
Leakage current
Input dissipation
mA
W
No Load
Output Short
2.5
W
Power Factor
115 VAC, full load
277 VAC, full load
0.98
0.92
Input Fuse
3.15A / 300V
Start-up Time
115 VAC, full load
277 VAC, full load
1.5
1.0
Sec.
Sec.
Output Specifications
Parameters
Current accuracy
Line regulation
Conditions
Typical
Maximum
Units
%
%
%
±5
±3
±5
LL to HL
Full Output Voltage Range
Load regulation
Ripple & Noise
8
1
10
0.5
%Vo
A p-p
%
Output Current Ripple
Current Overshoot
Hold-up time (min.)
Minimum Load Voltage
Full load, 16.7-20ms duration
LL to HL, full load at cold start, % of rated output current
ms
See Models Table Above
Isolation Specifications
Parameters
Conditions
I/P – O/P
I/P – FG
O/P – FG
I/P – O/P, 500Vdc
Typical
Rated
3750
2000
500
Units
VAC
VAC
VAC
VAC
Tested I/O voltage
Isolation Resistance
Isolation Capacitance
>100MΩ
3800
pF
General Specifications
Parameters
Switching frequency
Conditions
Typical
Maximum
130
Units
KHz
www.aimtec.com
F 052.1e R2
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER120-Z
up to 3000mA | AC-DC LED driver
Over current protection
Short circuit protection
Short circuit restart
Continuous, Hiccup mode
Continuous, Hiccup mode
Auto Recovery
Open circuit protection
Continuous, Hiccup mode
Threshold – Shutdown Output
Hysteresis – Auto Recovery
Without Derating
+100
+85
-40 to +60
+90
-40 to +85
oC
oC
Over Temperature Protection
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Potting material
IP Rating
Weight
oC
oC
oC
0.03
90
% / oC
Free Air Convection
% RH
g
Metal (Aluminum)
Polysiloxane
IP67
850
Dimensions (L X W X H)
MTBF
6.93 x 2.70 x 1.65 inches 176.0 x 68.7 x 42.0 mm
>400,000 hrs (MIL-HDBK-217F at +25°C)
Safety Specifications
Parameters
Electromagnetic Interference
Harmonic Current Emissions
Voltage fluctuations and flicker
EN55015 / FCC Part 15, Class B
EN61000-3-2, Class B
EN61000-3-3
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient / Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
EN61000-4-2, 8kV Air, 4kV Contact, Level 3, Criteria A
EN61000-4-3, Test-RS Level 3, Criteria A
EN61000-4-4, Burst EFT Level 3, Criteria A
EN61000-4-5, Line to Neutral 4kV, Line/Neutral to FG 6kV
EN61000-4-6. Test-CS Level 3, Criteria A
EN61000-4-8, Test 3A/m, Criteria A
Standards
EN61000-4-11, Criteria B
Electromagnetic Immunity Requirements Applies EN61547
to Lighting Equipment
Pin Definition
Application circuit
Wire
Brown
Blue
Connection
AC_L
FG
AC L
AC N
FG
+V Output
-V OUtput
LED+
LED-
Yellow/Green
Red
AC
Black
Input wire gauge #18
Output wire gauge #14
AC_N
www.aimtec.com
F 052.1e R2
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER120-Z
up to 3000mA | AC-DC LED driver
Dimensions
Top View
164.0±0.5
6.45±0.02
320±20
12.60±0.79
4.0
5.0±1.0
0.20±0.04
0.16
7.4
0.29
68.7±1.0
2.70±0.04
320±20
12.60±0.79
35.0±2.0
1.38±0.08
4.0
0.16
30.0±2.0
1.18±0.08
10.0±1.0
0.39±0.04
30.3
1.19
4.0
0.16
12.7
0.50
7.4
0.29
150±0.5
5.90±0.02
12.7
0.50
176.0±1.0
6.93+0.04
Side View
Yellow/Green
42.0±1.0
1.65±0.04
Blue
150±0.5
5.90±0.02
Brown
176.0±1.0
6.93+0.04
Efficiency Vs. Input Voltage & Output Voltage (Constant current load)
AMER120-42250Z
95.00%
90.00%
85.00%
115VAC
230VAC
277VAC
80.00%
75.00%
70.00%
65.00%
24
27
30
33
36
39
42
Output Voltage(V)
www.aimtec.com
F 052.1e R2
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER120-Z
up to 3000mA | AC-DC LED driver
AMER120-42300Z
95.00%
90.00%
85.00%
115VAC
230VAC
277VAC
80.00%
75.00%
70.00%
65.00%
24
27
30
33
36
39
42
Output Voltage(V)
PF vs. Input Voltage & Output Voltage (constant current mode)
AMER120-42250Z
1.200
0.900
115VAC
0.600
0.300
0.000
230VAC
277VAC
24
27
30
33
36
39
42
Output Voltage(V)
www.aimtec.com
F 052.1e R2
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER120-Z
up to 3000mA | AC-DC LED driver
AMER120-42300Z
1.200
0.900
0.600
0.300
115VAC
230VAC
277VAC
0.000
24
27
30
33
36
39
42
Output Voltage(V)
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052.1e R2
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
相关型号:
©2020 ICPDF网 联系我们和版权申明