AMER60N-42150Z [AIMTEC]
up to 1600mA | AC-DC LED driver;![AMER60N-42150Z](http://pdffile.icpdf.com/pdf2/p00329/img/icpdf/AMER60N-4213_2026118_icpdf.jpg)
型号: | AMER60N-42150Z |
厂家: | ![]() |
描述: | up to 1600mA | AC-DC LED driver |
文件: | 总6页 (文件大小:841K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
Series AMER60N-Z
up to 1600mA | AC-DC LED driver
FEATURES:
• Universal Input: 90~305 VAC
• High Efficiency: Up to 88%
• Active Power Factor Correction
• Short Circuit / Open Circuit Protection
•
•
•
•
IP65/67 Design for outdoor application
Long Life, High reliability
Ultra-low ripple without flickering
5-year limited warranty
Models
Single output
Max Output
Power (W)
54.6
Output Voltage
Range (V)
24-42
Output Current
(mA)
1300
1400
1500
Input Voltage
(VAC/Hz)
90-305/47-63
90-305/47-63
90-305/47-63
90-305/47-63
Efficiency
Model
(%)
87
87
88
88
AMER60N-42130Z
AMER60N-42140Z
AMER60N-42150Z
AMER60N-42160Z
58.8
63.0
67.2
24-42
24-42
24-42
1600
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity <75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Input Current
Conditions
Typical
Maximum
1.0
Units
Arms
90 VAC, full load
115 VAC, cold start
230 VAC, cold start
40
60
0.75
1.5
4.5
Inrush current <2ms
Leakage current
Input dissipation
A
mA
W
W
No Load
Output Short
115 VAC, full load
230 VAC, full load
0.98
0.95
Power Factor
Input Fuse
3.15A / 300V
115 VAC, full load
230 VAC, full load
1.5
1.0
Sec.
Sec.
Start-up Time
Output Specifications
Parameters
Current accuracy
Line regulation
Conditions
Typical
Maximum
Units
%
%
±5
±3
±5
LL to HL
Full Output Voltage Range
Load regulation
%
Ripple & Noise
Output Current Ripple
200
120
mV p-p
mA
Full load
LL to HL, full load at cold start,
% of rated output current
Current Overshoot
15
0
%
Hold-up time (min)
ms
Minimum Load Voltage
See Models Table Above
Isolation Specifications
Parameters
Conditions
I/P – O/P
I/P – FG
O/P – FG
500VDC
Typical
Rated
3750
2000
500
Units
VAC
VAC
VAC
MΩ
Tested I/O voltage
Isolation Resistance
Isolation Capacitance
>100
5000
pF
www.aimtec.com
F 052.1e R4
Tel: +1 514 620 2722
1 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER60N-Z
up to 1600mA | AC-DC LED driver
General Specifications
Parameters
Switching frequency
Over voltage protection
Over current protection
Short circuit protection
Short circuit restart
Open circuit protection
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Conditions
Typical
150
Maximum
Units
KHz
VDC
50
Constant Current Mode
Hiccup
Auto Recovery
Hiccup
With Derating over oC
-40 to +60
oC
oC
90
-40 to +90
oC
0.03
90
% / oC
Free Air Convection
Humidity
Case material
Potting material
IP Rating
% RH
g
Metal (Aluminum)
polysiloxane
IP67
Weight
490
Dimensions (L X W+ X H)
MTBF
7.36 X 1.91 X 1.31 inches 187.00 X 48.60 X 33.30 mm
400,000 hrs (MIL-HDBK-217F at +25°C)
Safety Specifications
Parameters
Electromagnetic Interference
Harmonic Current Emissions
Voltage fluctuations and flicker
EN55015 / FCC Part 15, Class B
EN61000-3-2, Class B
EN61000-3-3
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient / Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
EN61000-4-2, 8kV Air, 4kV Contact, Level 3, Criteria A
EN61000-4-3, Test-RS Level 3, Criteria A
EN61000-4-4, Burst EFT Level 3, Criteria A
EN61000-4-5, Line to Neutral 4kV, Neutral to FG 6kV
EN61000-4-6. Test-CS Level 3, Criteria A
EN61000-4-8, Test 3A/m, Criteria A
Standards
EN61000-4-11, Criteria B
Electromagnetic Immunity Requirements Applies EN61547
to Lighting Equipment
Pin Definition
Block diagram
Wire
Brown
Blue
Connection
AC L
AC N
FG
+V Output
-V OUtput
AC_L
FG
LED+
LED-
Yellow/Green
Red
AC
Black
AC_N
www.aimtec.com
F 052.1e R4
Tel: +1 514 620 2722
2 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER60N-Z
up to 1600mA | AC-DC LED driver
Dimensions
Top View
Unit:mm
187.00±2.00
7.36±0.08
9.00
0.35
2
2
H05RN-F 1mm *2C
H05RN-F 0.75mm * 3C
FG (Gre en/Yellow)
162.00±2.00
6.38±0.08
(Red)
LED+
LED-
7.00±0.20
0.28±0.01
AC_L (Brown)
AC_N (Blue)
7.00±0.20
0.28±0.01
(Black)
48.60
1.91
15.30
0.60
20.00
0.79
20.00
0.79
5.00
0.20
270.00±10.00
10.63±0.39
270.00±10.00
10.63±0.39
5.00
0.20
Side View
33.30
1.31
Derating Graph
115/230/277VAC
Free Air Convection
100.00%
80.00%
60.00%
40.00%
20.00%
0.00%
Safe Operating Area
-40 -30 -20 -10
Ta
0
10
20
30
40
50
60
70
̶
Ambient temperature (℃)
www.aimtec.com
F 052.1e R4
Tel: +1 514 620 2722
3 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER60N-Z
up to 1600mA | AC-DC LED driver
Efficiency Vs. Input Voltage & Output Voltage
AMER60N-42130Z
95.00%
90.00%
85.00%
80.00%
75.00%
70.00%
65.00%
115VAC
230VAC
277VAC
24
27
30
33
36
39
42
Output Voltage(V)
AMER60N-42140Z
95.00%
90.00%
85.00%
80.00%
75.00%
70.00%
65.00%
115VAC
230VAC
277VAC
24
27
30
33
36
39
42
Output Voltage(V)
AMER60N-42150Z
95.00%
90.00%
85.00%
80.00%
75.00%
70.00%
115VAC
230VAC
277VAC
65.00%
24
27
30
33
36
39
42
Output Voltage(V)
www.aimtec.com
F 052.1e R4
Tel: +1 514 620 2722
4 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER60N-Z
up to 1600mA | AC-DC LED driver
AMER60N-42160Z
95.00%
90.00%
85.00%
80.00%
75.00%
70.00%
115VAC
230VAC
277VAC
65.00%
24
27
30
33
36
39
42
Output Voltage(V)
PF vs. Input Voltage & Output Voltage
MER60N-42130Z
1.200
0.900
0.600
0.300
0.000
115VAC
230VAC
277VAC
24
27
30
33
36
39
42
Output Voltage(V)
AMER60N-42140Z
1.200
0.900
0.600
0.300
115VAC
230VAC
277VAC
0.000
24
27
30
33
36
39
42
Output Voltage(V)
www.aimtec.com
F 052.1e R4
Tel: +1 514 620 2722
5 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER60N-Z
up to 1600mA | AC-DC LED driver
AMER60N-42150Z
1.200
0.900
0.600
0.300
115VAC
230VAC
277VAC
0.000
24
27
30
33
36
39
42
Output Voltage(V)
AMER60N-42160Z
1.200
0.900
0.600
0.300
115VAC
230VAC
277VAC
0.000
24
27
30
33
36
39
42
Output Voltage(V)
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052.1e R4
Tel: +1 514 620 2722
6 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
相关型号:
©2020 ICPDF网 联系我们和版权申明