440F-C251D [ALLEN-BRADLEY]
Safety Edges; 安全边![440F-C251D](http://pdffile.icpdf.com/pdf1/p00138/img/icpdf/440F-C251D_765095_icpdf.jpg)
型号: | 440F-C251D |
厂家: | ![]() |
描述: | Safety Edges |
文件: | 总3页 (文件大小:73K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Presence Sensing Safety Devices
Safety Edges
Safedge™ Controllers
Specifications
Standards
EN1760-2, EN954-1, ISO 13849-1,
AS4024.5, EN954-1, ANSI B11.19
Safety Category
Approvals
Cat. 3 per EN954-1
CE marked for all applicable directives,
cULus, TuV
Power Supply 251
252
24V AC/DC or 110/230V AC 50/60Hz
24V AC/DC 50/60Hz
Power Consumption 251
252
<6VA
<4VA
Fuses, Internal 251D, 251P
251P
252D
500mA Power Supply, Replaceable
2 x 2A Safety Output, Replaceable
500mA, Resettable
Fuses, External
4A on AC, 2A on DC
Description
Safety Input Profile
6KΩ, 12V DC open circuit, 4V DC run
The Safedge controllers are designed to operate with the Safedge
profiles. The controller continuously monitors the profile for
actuation and generates an output signal when the profile is
depressed.
condition
1 N.O.
Monitoring
Maximum Input Impedance
Profile
Monitoring Circuit
9KΩ
1KΩ
The Safedge controller provides a low voltage to the profile. When
the profile is pressed, the controller detects a change in resistance
and turns off its output relays. When pressure is released from the
profile, the output relays of the controller return to an on state. The
controller has redundant voltage free positively-guided output relays
which can be used to interface with a machine control system.
Outputs 251 Safety
252 Safety
251, 252 Auxiliary
2 N.O.
1 N.O.
1 N.C.
Output Rating
2A/250V AC, 2A/125V AC
1A/30V DC
Min. Switching Current/Volt. 10mA/10V
Max. Response Time
Indication LEDs
13ms
The ‘251’ controller comes capable of operating at 24V AC/DC, or
120/230V AC from separate terminals. An internal switch changes
the operating voltage from 120V AC to 230V AC. The ‘252’
controller operates at 24V AC/DC.
Green = Run
Yellow = Open Circuit
Red = Stop
Impulse Withstand Voltage
Installation Group
Pollution Degree
2500V
C in accordance with VDE0110
An auxiliary output relay is available to provide a signal about the
controller’s status. Three LEDs indicate whether the controller is in
RUN, STOP or OPEN condition. The controller operates in manual
or automatic reset mode.
3
Operating Temperature
Humidity
-10°C to 55°C (-14°F to 131°F)
90% RH
Enclosure Protection
251D, 252D
251P
IP40 (NEMA 1)
IP65 (NEMA 13)
Features
•
•
•
•
•
•
1 N.O. or 2 N.O. Safety Outputs
1 N.C. Auxiliary Output
24V AC/DC or 120/240V AC
Output Monitoring
LED Indicators for RUN, STOP and OPEN
Automatic/Manual Reset
Terminal Protection
IP20 DIN 0470
Max Conductor Size
251D, 252D
2
1 x 4mm (10AWG) stranded
2
1 x 4mm (10 AWG) solid
2
251P
1 x 1.1mm (18AWG) stranded
2
1 x 1.5mm (16AWG) solid
Case Material
Polycarbonate
Weight 252D
251D
251P
181g (0.4lbs)
450g (1.0lbs)
650g (1.4lbs)
Vibration
Shock
0.15mm 10-55Hz
10g, 11ms half sine
2-103
Presence Sensing Safety Devices
Safety Edges
Safedge™ Controllers
Product Selection
Housing Type
Description
Catalogue Num ber
440F-C251D
35mm DIN Rail Mountable
440F-C252D
Surface Mountable
440F-C251P
Approximate Dimensions—mm (inches)
Dimensions are not intended to be used for installation purposes.
440F-C251D
440F-C251P
440F-C252D
22.5
(0.88)
130 (5.12)
115 (4.53)
45.5 (1.79)
120 (4.72)
75 (2.95)
118 (4.64)
Pg
16/21
Pg
16/21
35mm DIN Rail
Mounting
4 x M4 Mounting
Holes
Block Diagram
L
N
X1 X2
13 23 31
+Ve
Z2
F1
24VDC
K2
K3
K2
K3 K1
VR
12V
K1
~
K1
K2
Q1
K1
K1
K2
Logic
Y
K3
K2
Q2
G
R
Z1
E
-Ve
14 24 32
2-104
Presence Sensing Safety Devices
Safety Edges
Safedge™ Controllers
Typical Wiring Diagrams
L1
24V DC
Reset
L1 L2 L3
L1 L2 L3
23 31
13
L
Z1 Z2 X1
+Ve
23 31
13
+Ve Z1 Z2 X1
L
K1
K2
440F-C251D
440F-C251P
440F-C251D
440F-C251P
K1
K2
Ve
-
42
24
N
X2 14
K1
42
24
Ve
N
-
X2 14
K1
M
M
K2
K2
24V Ground
N
Series Terminated, Safedge Input, Manual Reset,
Dual Channel Output, Monitored Output
Series Terminated, Cascaded, Safedge Input, Automatic
Reset, Dual Channel Output, No Output Monitored
+24V DC
+24V DC
Reset
L1 L2 L3
L1 L2 L3
21
21
22
13
13
+
Z1 Z2
X1
+
Z1 Z2
X1
K1
K1
K2
440F-C252D
440F-C252D
M
22
-
X2 14
K1
-
X2 14
K1
M
K2
24V Ground
24V Ground
Parallel Terminated, Safedge Input, Manual Reset,
Dual Channel Output, Monitored Output
Series Terminated, Safedge Input, Automatic Reset,
Single Channel Output, No Output Monitored
Accessories
Description
Page
14-6
14-2
Catalogue Num ber
440R-A31562
Fuse, 500mA
Fuse, 2A
440A-A09197
2-105
相关型号:
©2020 ICPDF网 联系我们和版权申明