440F-C251D [ALLEN-BRADLEY]

Safety Edges; 安全边
440F-C251D
型号: 440F-C251D
厂家: Allen-Bradley    Allen-Bradley
描述:

Safety Edges
安全边

文件: 总3页 (文件大小:73K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Presence Sensing Safety Devices  
Safety Edges  
Safedge™ Controllers  
Specifications  
Standards  
EN1760-2, EN954-1, ISO 13849-1,  
AS4024.5, EN954-1, ANSI B11.19  
Safety Category  
Approvals  
Cat. 3 per EN954-1  
CE marked for all applicable directives,  
cULus, TuV  
Power Supply 251  
252  
24V AC/DC or 110/230V AC 50/60Hz  
24V AC/DC 50/60Hz  
Power Consumption 251  
252  
<6VA  
<4VA  
Fuses, Internal 251D, 251P  
251P  
252D  
500mA Power Supply, Replaceable  
2 x 2A Safety Output, Replaceable  
500mA, Resettable  
Fuses, External  
4A on AC, 2A on DC  
Description  
Safety Input Profile  
6K, 12V DC open circuit, 4V DC run  
The Safedge controllers are designed to operate with the Safedge  
profiles. The controller continuously monitors the profile for  
actuation and generates an output signal when the profile is  
depressed.  
condition  
1 N.O.  
Monitoring  
Maximum Input Impedance  
Profile  
Monitoring Circuit  
9KΩ  
1KΩ  
The Safedge controller provides a low voltage to the profile. When  
the profile is pressed, the controller detects a change in resistance  
and turns off its output relays. When pressure is released from the  
profile, the output relays of the controller return to an on state. The  
controller has redundant voltage free positively-guided output relays  
which can be used to interface with a machine control system.  
Outputs 251 Safety  
252 Safety  
251, 252 Auxiliary  
2 N.O.  
1 N.O.  
1 N.C.  
Output Rating  
2A/250V AC, 2A/125V AC  
1A/30V DC  
Min. Switching Current/Volt. 10mA/10V  
Max. Response Time  
Indication LEDs  
13ms  
The ‘251’ controller comes capable of operating at 24V AC/DC, or  
120/230V AC from separate terminals. An internal switch changes  
the operating voltage from 120V AC to 230V AC. The ‘252’  
controller operates at 24V AC/DC.  
Green = Run  
Yellow = Open Circuit  
Red = Stop  
Impulse Withstand Voltage  
Installation Group  
Pollution Degree  
2500V  
C in accordance with VDE0110  
An auxiliary output relay is available to provide a signal about the  
controller’s status. Three LEDs indicate whether the controller is in  
RUN, STOP or OPEN condition. The controller operates in manual  
or automatic reset mode.  
3
Operating Temperature  
Humidity  
-10°C to 55°C (-14°F to 131°F)  
90% RH  
Enclosure Protection  
251D, 252D  
251P  
IP40 (NEMA 1)  
IP65 (NEMA 13)  
Features  
1 N.O. or 2 N.O. Safety Outputs  
1 N.C. Auxiliary Output  
24V AC/DC or 120/240V AC  
Output Monitoring  
LED Indicators for RUN, STOP and OPEN  
Automatic/Manual Reset  
Terminal Protection  
IP20 DIN 0470  
Max Conductor Size  
251D, 252D  
2
1 x 4mm (10AWG) stranded  
2
1 x 4mm (10 AWG) solid  
2
251P  
1 x 1.1mm (18AWG) stranded  
2
1 x 1.5mm (16AWG) solid  
Case Material  
Polycarbonate  
Weight 252D  
251D  
251P  
181g (0.4lbs)  
450g (1.0lbs)  
650g (1.4lbs)  
Vibration  
Shock  
0.15mm 10-55Hz  
10g, 11ms half sine  
2-103  
Presence Sensing Safety Devices  
Safety Edges  
Safedge™ Controllers  
Product Selection  
Housing Type  
Description  
Catalogue Num ber  
440F-C251D  
35mm DIN Rail Mountable  
440F-C252D  
Surface Mountable  
440F-C251P  
Approximate Dimensions—mm (inches)  
Dimensions are not intended to be used for installation purposes.  
440F-C251D  
440F-C251P  
440F-C252D  
22.5  
(0.88)  
130 (5.12)  
115 (4.53)  
45.5 (1.79)  
120 (4.72)  
75 (2.95)  
118 (4.64)  
Pg  
16/21  
Pg  
16/21  
35mm DIN Rail  
Mounting  
4 x M4 Mounting  
Holes  
Block Diagram  
L
N
X1 X2  
13 23 31  
+Ve  
Z2  
F1  
24VDC  
K2  
K3  
K2  
K3 K1  
VR  
12V  
K1  
~
K1  
K2  
Q1  
K1  
K1  
K2  
Logic  
Y
K3  
K2  
Q2  
G
R
Z1  
E
-Ve  
14 24 32  
2-104  
Presence Sensing Safety Devices  
Safety Edges  
Safedge™ Controllers  
Typical Wiring Diagrams  
L1  
24V DC  
Reset  
L1 L2 L3  
L1 L2 L3  
23 31  
13  
L
Z1 Z2 X1  
+Ve  
23 31  
13  
+Ve Z1 Z2 X1  
L
K1  
K2  
440F-C251D  
440F-C251P  
440F-C251D  
440F-C251P  
K1  
K2  
Ve  
-
42  
24  
N
X2 14  
K1  
42  
24  
Ve  
N
-
X2 14  
K1  
M
M
K2  
K2  
24V Ground  
N
Series Terminated, Safedge Input, Manual Reset,  
Dual Channel Output, Monitored Output  
Series Terminated, Cascaded, Safedge Input, Automatic  
Reset, Dual Channel Output, No Output Monitored  
+24V DC  
+24V DC  
Reset  
L1 L2 L3  
L1 L2 L3  
21  
21  
22  
13  
13  
+
Z1 Z2  
X1  
+
Z1 Z2  
X1  
K1  
K1  
K2  
440F-C252D  
440F-C252D  
M
22  
-
X2 14  
K1  
-
X2 14  
K1  
M
K2  
24V Ground  
24V Ground  
Parallel Terminated, Safedge Input, Manual Reset,  
Dual Channel Output, Monitored Output  
Series Terminated, Safedge Input, Automatic Reset,  
Single Channel Output, No Output Monitored  
Accessories  
Description  
Page  
14-6  
14-2  
Catalogue Num ber  
440R-A31562  
Fuse, 500mA  
Fuse, 2A  
440A-A09197  
2-105  

相关型号:

440F-C251P

Safety Edges
ALLEN-BRADLEY

440F-C252D

Safety Edges
ALLEN-BRADLEY

440F-E0110N05

Safety Edges
ALLEN-BRADLEY

440F-E0110N10

Safety Edges
ALLEN-BRADLEY

440F-E0110N20

Safety Edges
ALLEN-BRADLEY

440F-E0110R05

Safety Edges
ALLEN-BRADLEY

440F-E0110R10

Safety Edges
ALLEN-BRADLEY

440F-E0110R20

Safety Edges
ALLEN-BRADLEY

440F-E0110S05

Safety Edges
ALLEN-BRADLEY

440F-E0110S10

Safety Edges
ALLEN-BRADLEY

440F-E0110S20

Safety Edges
ALLEN-BRADLEY

440F-E0310S05

Safety Edges
ALLEN-BRADLEY