700S-CF530XC [ALLEN-BRADLEY]
Safety Control Relays; 安全控制继电器型号: | 700S-CF530XC |
厂家: | Allen-Bradley |
描述: | Safety Control Relays |
文件: | 总12页 (文件大小:193K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Contactors & Control Relays
Safety Control Relays
700S-CF
Specifications
Conform ity to Standards
IEC 60947-5-1
IEC 60947-5-1 Annex L — Special
Requirements for Mechanically Linked
Contact Elements
EN50011, EN50005, EN50022
UL 508
VDE 0660
Description
CSA 22.2 No. 14
Bulletin 700S-CF Safety Control Relays provide mechanically linked,
positively guided contacts, which are required in feedback circuits
for modern safety applications. The positively guided N.C. auxiliary
contacts will not change state if a N.O. contact welds. Consult your
local sales office or price list for pricing information.
Approvals
SUVA Third-Party Certified
CE Certified
Features
CSA Certified
•
Positively guided/mechanically linked auxiliary contacts
UL Listed (File No. E14840, Guide No. NKCR)
C-Tick not required
•
Front-mounted auxiliary contact:
– Permanently fixed
– Protective cover to prevent manual operation
– Red contact housing for easy identification
– Incorporates IEC 60947-5-1 “Mechanically Linked” symbol
AC and DC operating coils
Your order m ust include:
•
•
•
Catalogue number of the relays required, complete with coil
•
•
suffix.
SUVA third-party certification
Catalogue number of adder decks, timers and accessories
required.
If required, the part number of replacement coils.
9-17
Contactors & Control Relays
Safety Control Relays
700S-CF
Product Selection
Type CF Control Relays — 8-Pole AC Coil Voltage
AC-12
AC-15
Connection Diagram s
Contacts
I
[A]
I [A]
e
th
Main
Contacts
Auxiliary
Contacts
Catalogue
Num ber !
24/
40°C 60°C 48V 120V 240V 400V 500V 600V 690V
NO
NC
53
61
71
81
82
13
14
21
22
33
43
44
A1
A2
K1
K1
K1
700S-CF440
700S-CF530
700S-CF620
C
C
C
4
4
34
54
62
72
Main
Contacts
20
10
20
10
10
10
6
3
2.5
1.6
1
1
1
1
53
61
71
83
13
14
21
22
33
34
43
44
A1
A2
5
6
3
2
54
53
62
61
72
73
84
83
13
14
21
22
33
34
43
44
Adder
Deck
Contacts
A1
A2
6
6
6
5
54
62
74
84
! All Catalogue Numbers are factory-stocked.
AC Coil Voltage Code
The Catalogue Number is incomplete. Select a coil voltage code from the table below to complete the Catalogue Number. Example: 120V 60 Hz:
Catalogue Number 700S-CF440 C becomes Catalogue Number 700S-CF440DC.
100-
110
200-
220
208- 220-
Voltage
50 Hz
12
R
24
K
32
V
–
36
W
V
42
X
–
48
Y
100
KP
–
110
D
120
P
127
S
200
KG
–
208
–
240
230
–
KP
–
L
–
F
60 Hz
Q
–
J
X
–
D
–
KG
KL
H
L
–
50/60 Hz
KJ
–
–
–
KY
KP
KD
–
–
KG
–
–
KL
230-
240
380-
400
400-
415
Voltage
50 Hz
230
–
240
277
–
347
380
400
–
440
480
–
500
550
600
–
VA
–
T
A
–
I
–
E
–
N
–
G
B
N
M
–
C
–
60 Hz
–
T
–
–
B
C
50/60 Hz
KF
–
KA
–
–
–
KN
–
KB
–
–
–
–
9-18
Contactors & Control Relays
Safety Control Relays
700S-CF
Product Selection
Type CF Control Relays — 8-Pole DC Coil Voltage
AC-12
AC-15
Connection Diagram s
Contacts
I
[A]
I [A]
e
th
Main
Contacts
Auxiliary
Contacts
Catalogue
Num ber !
24/
40°C 60°C 48V 120V 240V 400V 500V 600V 690V
NO
NC
53
61
71
81
82
13
21
33
43
44
A1
A2
K1
K1
K1
700S-CF440
700S-CF530
700S-CF620
C
C
C
4
4
14
22
34
54
62
72
Main
Contacts
20
10
20
10
10
10
6
3
2.5
1.6
1
1
1
1
53
61
71
83
13
14
21
22
33
34
43
44
A1
A2
5
6
3
2
54
53
62
61
72
73
84
83
13
14
21
22
33
34
43
44
Adder
Deck
Contacts
A1
A2
6
6
6
5
54
62
74
84
! All Catalogue Numbers are factory-stocked.
DC Coil Voltage Code
The Catalogue Number is incomplete. Select a coil voltage code from the table below to complete the Catalogue Number. Example: 24V DC:
Catalogue Number 700S-CF440 C becomes Catalogue Number 700S-CF440ZJC .
Voltage
9
12
24
ZJ
36
48
60
64
72
80
110
ZD
115
ZP
125
ZS
220
ZA
230
ZF
250
ZT
Standard
ZR
ZQ
ZW
ZY
ZZ
ZB
ZG
ZE
With diode
suppressor
—
—
DJ
—
—
—
—
—
—
—
—
—
—
—
—
9-19
Contactors & Control Relays
Safety Control Relays
100S-C and 700S-CF
General
Mechanically Linked Contacts➋
Yes!
State of N.C. Contacts if N.O. contact welds
Aux.
Contact
(Front-
Location of
welded
N.O.
Catalogue
Num ber
700S-CF
Main
Front aux.
m ounted)
contacts
Contact Ratings — NEMA
A600, P600 A600, Q600
10 mA
Main
Open
Open
Open
17V
24V
48V
Minimum Contact Rating
Front aux. Open
Left side
aux.
10A
10A
6A
6A
Open !
Open
Open
Contact Ratings — IEC
120V
240V
AC-15 (solenoids,
contactors) at rated
voltage
10A
10A
6A
5A
Right side
aux.
Open !
! Side-mounted auxiliary contacts provide “mirror contact” performance.
➋ Defined in IEC 60947-5-1 annex L. Positive guidance is a relationship between
contacts of opposite types (i.e., N.O. and N.C.)
400V
480V/500V
600V
6A
2.5A
1A
3A
1.6A
1A
General
690V
1A
1A
Aux.
I
Catalogue
Num ber
700S-CF
Contact
(Front-
m ntd.)
th
20A
10A
40ºC
230V
400V
690V
AC-12 (Non-inductive, or
slightly inductive loads,
resistance furnaces)
8 kW
14 kW
24 kW
Mechanical Life
Electrical Life
[Mil]
[Mil]
15
15
AC-15
(240V, 3A)
1.5
1.5
60º C
AC Op.
Mechanism
I
20A
8 kW
6A
Weight
[g]
390
–
th
230V
400V
690V
Te r m i nal C ro s s-
Sections
14 kW
24 kW
Te r m i nal Ty pe
Switching DC Loads
Te r m i nal S i ze
per IEC 60947-1
24V
48V
2 x A4
2 x A4
12A
9A
12A
9A
DC-12
Flex.
with
Wire
End
L
110V
/
< 1ms, Resistive Loads
3.5A
3.5A
R
1 Conductor [mm2]
2 Conductor [mm2]
1…4
1…4
0.5…2.5
0.75…2.5
220V
440V
24V
0.55A
0.2A
9A
0.55A
0.2A
9A
Ferrule
Solid
1 Conductor [mm2]
2 Conductor [mm2]
1.5…6
1.5…6
0.5…2.5
0.75…2.5
DC-14
L
48V
/
< 15ms, Inductive
5A
2A
5A
2A
R
Max. Wire Size
per UL/CSA
[AWG]
[lb-in]
[Nm]
16…10
8.9…22
1…2.5
18…14
8.9…13.3
1…1.5
110V
220V
Loads
with economy resistor in
series
Tightening
Torque
0.4A
0.4A
440V
24V
0.16A
5A
0.16A
5A
Tightening
Torque
48V
3A
3A
DC-13
Switching electromagnets
110V
220V
440V
1.2A
0.6A
0.3A
1.2A
0.6A
0.15A
9-20
Contactors & Control Relays
Safety Control Relays
100S-C and 700S-CF
General (continued)
General (continued)
Aux.Contact
Catalogue Num ber 700S-CF
(Side-m ounted)
Rated Insulation Voltage U
i
Contact Ratings — IEC
AC-15 (solenoids, contactors) at rated
voltage
120V
240V
6
5
IEC
690V
600V
8 kV
UL; CSA
Rated Impulse Strength U
imp
IEC 60947
400V
500V
3
High Test Voltage
1.6
1 minute (per IEC 947-4)
2500V
AC-12 (Non-inductive, or
slightly inductive loads,
resistance furnaces), IEC60947
I
10A
th
40ºC
60ºC
Rated Voltage U
e
I
6A
3A
th
AC
DC
115, 230, 400, 500, 690V
24, 48, 110, 220, 440V
DC-13 (Solenoids and
contactors), IEC60947
24V
48V
1.5A
Short-Circuit Protection IEC 158-
1 Fuse, gG
10A
110V
220V
440V
[AWG]
[lb-in]
[Nm]
0.6A
Rated Frequency
50/60 Hz, DC
0.3A
Ambient Temperature
Storage
0.2A
–55…+80 °C (–67…176 °F)
–25…+60 °C (–13…140 °F)
Max. Wire Size per UL/CSA
Tightening Torque
18…14
8.9…13.3
1…1.5
Operation at nominal current
Conditioned 15% current
reduction after AC-1 at > 60°C
Tightening Torque
–25…+70 °C (–13…158 °F)
Control Circuit
humid-alternating climate,
cyclic, per IEC 68-2-30 and
DIN 50 016, 56 cycles
Corrosion Resistance
Altitude
Catalogue
Num ber
700S-CF
2000m above mean sea level,
per IEC 60947-4
Operating Voltage
Type of Protection
[x U ]
AC 50/60 Hz
Pick-up
Dropout
Pick-up
Dropout
0.85…1.1
0.3…0.6
0.8…1.1
0.1…0.6
s
IP 2X (IEC 529 and DIN 40050)
in connected state
[x U ]
s
safe from touch by fingers and back
of hand per VDE 0106, Part 100
Finger Protection
[x U ]
DC!
s
[x U ]
s
Coil
Consumption
AC 50/60 Hz
Inrush
[VA/W]
[VA/W]
[W]
70/50
8/2.6
6.5
Seal
DC
Inrush/Seal
Operating Times
AC 50/60 Hz
Pick-up Time
[ms]
15…30
10…60
40…70
7…15
Dropout Time [ms]
Pick-up Time [ms]
Dropout Time [ms]
DC
! For 9V DC, code ZR, use operating voltage 0.65…1.3 x Us.
For 24V DC, code ZJ or DJ, use operating voltage 0.7…1.25 x Us.
9-21
Contactors & Control Relays
Safety Control Relays
100S-C and 700S-CF
Auxiliary Contacts
For Use W ith
Catalogue Num ber
Catalogue
Num ber
Description
NO
NC
Connection Diagram s
-3
- 4
Auxiliary Contact Blocks for Side
Mounting without Sequence
Terminal Designations !
• 1- and 2-pole
100S-C all
700S-CF all
100-SA10
100-SA20
100-SB10
1
0
-4
- 3
-SA10
• Two-way numbering for right or left
mounting on the contactor
• Quick and easy mounting without
tools
• Electronic-compatible contacts down
to 17V, 10mA
-3 -3
- 4 - 4
-4 -4
- 3 - 3
100S-C AC only
700S-CF AC only
2
0
-SA20
13
4 4
Auxiliary Contact Blocks for Side
Mounting with Sequence Terminal
Designations !
100S-C09…C23
700S-CF all➋
1
0
14
4 3
• 1- and 2-pole
• Two-way numbering for right or left
mounting on the contactor
• Quick and easy mounting without
tools
-SB10
13 23
4 4 3 4
• Electronic compatible contacts down
to 17V, 10mA
• L = Late break/Early make
14 24
4 3 3 3
100S-C09…C23 AC only
700S-CF AC only➋
2
0
100-SB20
-SB20
! AC Coils: Max. 2 N.O. auxiliary contacts may be mounted on the side. DC coils: Max. 1 N.O. auxiliary contact may be mounted on the side. No additional N.C. auxiliary
contacts may be added to safety contactors and control relays listed in this publication. For additional contact configurations, consult your local Rockwell Automation/Allen-
Bradley distributor.
➋ Double Numbering — Left-side mounting only is recommended for Catalogue Number 700S-CF… due to double numbering.
Marking Systems
Uniform labelling materials for contactors, motor starting equipment, timing relays and circuit breakers
Catalogue
Description
Package Q ty.
Num ber
Label Sheet
100-FMS
10
• Sheet with 105 self-adhesive paper labels, 6 x 17 mm
Marking Tag Sheet
• Sheet with 160 perforated paper labels, 6 x 17 mm
• To be used with a transparent cover
100-FMP
10
Transparent Cover
• To be used with marking tag sheets
100-FMC
100-FMA1
100-FMA2
100
100
100
System V4/V5
Marking Tag Adaptors
• 100 each
• To be used with marking tag:
System Bul. 1492W
9-22
Contactors & Control Relays
Safety Control Relays
100S-C and 700S-CF
Control Modules
For Use W ith
Connection
Diagram s
Catalogue
Num ber
Catalogue
Num ber
Description
DC Interface (electronic)
• Interface between the DC control signal (PLC) and the contactor
AC operating mechanism
• Control voltage 18…30V DC (24V DC nominal)
• For coil voltage of 110… 240V AC
• Suitable for all 100S-C contactor sizes, 9…85 A
• Requires no additional surge suppression for the coils
• Power consumption
100S-C with AC coils
700S-CF with AC
coils
100-JE
K1M
– 0.1 W at 18V DC
(K1M)
– 0.25 W at 24V DC
– 0.5 W at 30V DC
100-FSC48
100-FSC280
100-FSC480
RC Module
AC Operating
Mechanism
24…48V, 50/60 Hz
110…280V, 50/60 Hz
380…480V, 50/60 Hz
100S-C with AC coils
700S-CF with AC
coils
Surge Suppressors
For limitation of coil
switching transients.
• Plug-in, coil mounted
• Suitable for all 100S-C
contactor sizes, 9…85
A
Varistor
Module
AC/DC
Operating
Mechanism
12…55V AC/12…77V DC
56…136V AC /78…180V DC
137…277V AC /181…350V
DC
100-FSV55
100-FSV136
100-FSV277
100-FSV575
100S-C all
700S-CF all
278…575V AC
• RC, Varistor and
Diode Versions
Diode Module
DC Operating
Mechanism
100S-C with DC coils
700S-CF with
DC coils
100-FSD250
12…250V DC
9-23
Contactors & Control Relays
Safety Control Relays
100-D
Auxiliary Contacts
For Use with
Catalogue
Num ber
Connection
Diagram s
Catalogue
Num ber
Description
NO
NC
100-D
Left or right
outside mounting
100-DS2-11
100-DS2-20
1
1
• Side-mounted
• With IEC sequence terminal designations
53 63
8 4 7 4
100-D
Left or right
2
1
0
1
54 64
8 3 7 3
outside mounting
• Electronically compatible auxiliary contacts
• Ideal for use when switching low-power control
circuits
100-D
Left or right
outside mounting
100-DS2-B11
• Contact ratings:
AC-1
AC-15, DC-13
250V, 0.1 A
3…125V, 1…100V,
Labeling Material
• Uniform labeling materials for contactors, motor protection devices, timing relays, and circuit breakers.
Marking Systems (for 100-D95...D860 contactors)
Catalogue
Num ber
Description
Package Q ty.
Label Sheet
100-FMS
10
• 10 sheets with 105 self-adhesive paper labels each, 6 x 17mm
Marking Tag Sheet
• 10 sheets with 160 perforated paper labels each, 6 x 17mm
• To be used with a transparent cover
100-FMP
100-FMC
10
Transparent Cover
• 100 each
100
• To be used with marking tag sheets
Marking Tag Adaptors
• 100 each
100-FMA1
100-FMA2
System V4/V5
System Bul. 1492W
100
100
• To be used with marking tag:
9-24
Contactors & Control Relays
Safety Control Relays
100S-C and 700S-CF
Auxiliary Contacts
Internal Auxiliar y Contacts
Catalogue Num bers
Side-Mounted Auxiliar y Contacts
Catalogue Num bers
100S-C09...100S-C23
100-SA, 100-SB, 100-MC
Current Switching
AC-12 I
at 40°C
at 60°C
[A]
[A]
25
20
10
6
th
AC-15 at Rated Operating Voltage
DC-13 at Rated Operating Voltage
Continuous Current Rating per UL/CSA
[V] 24 48 120 240 400 415 500 690 24 48 120 240 400 415 500 690
[A] 10 10 10 10 2.5 1 2.5 1.6
[V] 24 48 110 220 400
6
5
6
6
6
5
3
1
24 48 110 220 400
0.7 0.25 0.12
[A]
5
2
0.7 0.25 0.12
5
2
[A]
[A]
AC
DC
10A, 600V (NEMA A600)
5A, 600V (NEMA P600)
10A, 600V (NEMA A600)
2.5A, 600V (NEMA Q600)
Short-Circuit Protection
gG Fuse
[A]
Type 2 Coordination
10
8
10
6
Rated Im pulse Voltage U
[kV]
imp
Insulation Voltage (between control and load circuit) per
DIN, VDE 0106, Part 101 (NAMUR recommendation)
[V]
250
500
Contact reliability per DIN 19240 without contamination, normal
industrial atmosphere
17V, 10mA
17V, 10mA
100-SA, 100-SB: Mirror output
performance per IEC60947-4 Annex F
100-MC: Mutually unrestricted
Mechanically Linked Contacts per IEC
60947-5-1 Annex L (SUVA Third-party
certified)
Mutually unrestricted between
all N.O. and N.C. contacts
between all N.O. and N.C. contacts
Terminals
Terminal Type
2 x A4
2 x A4
Wire Size per IEC 60947-1
2
1 Conductor
2 Conductor
1 Conductor
2 Conductor
[mm ]
1…4
1…4
0.5…2.5
0.75…2.5
0.5…2.5
Flexible w/Wire-End Ferrule
2
[mm ]
2
[mm ]
1.5…6
1.5…6
Solid/Stranded Conductor
2
0.75…2.5
[mm ]
Nm
[AWG]
[lb-in]
Recommended Tightening Torque (min...max)
Wire Size per UL/CSA
Recommended Tightening Torque (min...max)
1...2.5
16…10
8.9…22
1…1.5
18…14
8.9…13.3
9-25
Contactors & Control Relays
Safety Control Relays
100-DS2
Auxiliary Contacts
Side-Mounted Auxiliary Contacts
Catalogue Num bers
100-DS2
Conventional
Electronically Com patible
Current Switching
AC-12 I
at 40°C
at 60°C
[A]
[A]
16
12
0.1 at 250V
th
AC-15 at Rated Operating Voltage
DC-13 at Rated Operating Voltage
Continuous Current Rating per UL/CSA
[V] 230 240 400 415 500 690
[A]
[V]
[A]
5.5
24 48 110 220 440
0.7 0.25 0.12
5
3
2.5 1.6
1
1… 100mA
at 3… 125V
5
2
[A]
[A]
AC
DC
10A, 600V (NEMA A600)
2.5A, 600V (NEMA Q600)
Short-Circuit Protection
gG Fuse
[A]
Type 2 Coordination
10
8
—
Rated Im pulse Voltage U
[kV]
imp
Insulation Voltage (between control and load circuit) per
DIN, VDE 0106, Part 101 (NAMUR recommendation)
[V]
Contact reliability per DIN 19240 without contamination, normal
industrial atmosphere
17V, 5mA
17V, 1mA
Mechanically Linked Contacts per IEC
60947-5-1 Annex L (SUVA Third-party
certified)
Mirror contact performance per IEC
60947-4 Annex F
Mirror contact performance per IEC
60947-4 Annex F
Te r m i nal s
Te r m i nal Ty pe
2 x A4
2 x A4
Wire Size per IEC 60947-1
2
1 Conductor
2 Conductor
1 Conductor
2 Conductor
[mm ]
1…2.5
1…2.5
1…4
1…2.5
1…2.5
1…4
Flexible w/Wire-End Ferrule
2
[mm ]
2
[mm ]
Solid/Stranded Conductor
2
1…4
1…4
[mm ]
Nm
[AWG]
[lb-in]
Recommended Tightening Torque (min...max)
Wire Size per UL/CSA
Recommended Tightening Torque (min...max)
1.4…2.3
16…12
12…20
1.4…2.3
16…12
12…20
9-26
Contactors & Control Relays
Safety Control Relays
100S-C and 700S-CF
Dimensions—mm (inches)
Dimensions are not intended for manufacturing purposes.
Mounting Position
c2
AC Contactors and Control Relays
DC Contactors and Control Relays
➋
c1
c
AC Contactors and Control Relays
a
b
c
c1
c2
d
d1
d2
Catalogue Num ber
45
(1-25/32)
81
(3-3/16)
119.5
(4-3/4)
114.5
(4-43/64)
6
(1/4)
2 - 4.5
(2 - 3/16)
60
(2-23/64)
35
(1-25/64)
100S-C09…100S-C23, 700S-CF
45
(1-25/32)
81
(3-3/16)
136.5
(5-37/64)
131.6
(5-11/32)
6.5
(17/64)
2 - 4.5
(2 - 3/16)
60
(2-23/64)
35
(1-25/64)
100S-C30, 100S-C37
100S-C43
54
(2-1/8)
81
(3-3/16)
139.5
(5-11/16)
134.6
(5-29/64)
6.5
(17/64)
2 - 4.5
(2 - 3/16)
60
(2-23/64)
45
(1-25/32)
72
(2-53/64)
122
(4-51/64)
156
(6-11/32)
150.5
(6-1/8)
8.5
(21/64)
4 - 5.4
(4 - 7/32)
100
(3-15/16)
55
(2-11/64)
100S-C60…100S-C85
DC Contactors and Control Relays
a
b
c
c1
c2
d
d1
d2
Catalogue Num ber
100S-C09Z...100S-C16Z, 700S-
CF
45
(1-25/32)
81
(3-3/16)
145.5
(5-49/64)
140.5
(5-37/64)
6
(1/4)
2 - 4.5
(2 -3/16)
60
(2-23/64)
35
(1-25/64)
45
(1-25/32)
81
(3-3/16)
162.5
(6-7/16)
158
(6-1/4)
6
(1/4)
2 - 4.5
(2 -3/16)
60
(2-23/64)
35
(1-25/64)
100S-C23Z
100S-C30...100S-C37
100S-C43Z
45
(1-25/32)
81
(3-3/16)
180.5
(7-5/32)
175.5
(6-61/64)
6.5
(17/64)
2 - 4.5
(2 -3/16)
60
(2-23/64)
35
(1-25/64)
54
(2-1/8)
81
(3-3/16)
183.5
(7-17/64)
179
(7-3/32)
6.5
(17/64)
2 - 4.5
(2 -3/16)
60
(2-23/64)
45
(1-25/32)
72
(2-53/64)
122
(4-51/64)
156
(6-11/32)
150.5
(6-1/8)
8.5
(21/64)
4 - 5.4
(4 -7/32)
100
(3-15/16)
55
(2-11/64)
100S-C60D...100S-C85D
Accessories
Contactors with
m m
a + 9
b + 24
a + 9
b + 9
b + 3
(inches)
(a + 23/64)
(b + 15/16)
(a + 23/64)
(b + 23/64)
(b + 1/8)
Auxiliary contact block for side mounting 1- or 2-pole
Electronic Timing Module on coil terminal side
Mechanical Interlock on side of contactor
Interface Module on coil terminal side
Surge Suppressor on coil terminal side
Labelling with label sheet
+ 0
+ 0
+ 5.5
+ 5.5
(+ 0)
(+ 0)
(+ 7/32)
(+ 7/32)
marking tag sheet with clear cover
marking tag adapter for System V4/V5
marking tag adapter for System Bul. 1492W
9-27
Contactors & Control Relays
Safety Control Relays
100S-D Contactors and Accessories
Dimensions—mm (inches)
Dimensions are not intended for manufacturing purposes.
Mounting Position
e2
c1
e1
øe
➋
ød
d2
a
c
Catalogue Num ber
a
b
c
c1
ød
5.2
5.2
6.5
10
d1
d2
øe
M6
e1
16
20
25
40
e2
38.5
39
e3
e4
8
100S-D95, 100S-D110
120
120
155
255
170
170
205
310
156
156
180
265
110.5
110.5
110.5
110.5
145
145
180
230
100
100
130
225
147
160
193
291
100S-D95-EI…100S-D180-EI, 100S-D140, 100S-D180
100S-D210-EI…100S-D420-EI
M8
10
M10
M12
48
12.5
22
100S-D630-EI…100S-D860-EI
70
Contactor with
[m m ]
Auxiliary contact block
Mechanical interlock
100-DS2…
100-DM…
a + 13.5 each
a + a
100-DTB110
100-DTB180
100-DTB420
b + 7 each
b + 7 each
b + 8.5 each
Frame terminal block
Label holder
c…+ 5
➋ Convention DC coil contactors will have an additional auxiliary contact block mounted which will add 13.5mm (0.53in) to the “a” dimension on the right hand side.
9-28
相关型号:
©2020 ICPDF网 联系我们和版权申明