700S-CF530XC [ALLEN-BRADLEY]

Safety Control Relays; 安全控制继电器
700S-CF530XC
型号: 700S-CF530XC
厂家: Allen-Bradley    Allen-Bradley
描述:

Safety Control Relays
安全控制继电器

继电器
文件: 总12页 (文件大小:193K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Contactors & Control Relays  
Safety Control Relays  
700S-CF  
Specifications  
Conform ity to Standards  
IEC 60947-5-1  
IEC 60947-5-1 Annex L — Special  
Requirements for Mechanically Linked  
Contact Elements  
EN50011, EN50005, EN50022  
UL 508  
VDE 0660  
Description  
CSA 22.2 No. 14  
Bulletin 700S-CF Safety Control Relays provide mechanically linked,  
positively guided contacts, which are required in feedback circuits  
for modern safety applications. The positively guided N.C. auxiliary  
contacts will not change state if a N.O. contact welds. Consult your  
local sales office or price list for pricing information.  
Approvals  
SUVA Third-Party Certified  
CE Certified  
Features  
CSA Certified  
Positively guided/mechanically linked auxiliary contacts  
UL Listed (File No. E14840, Guide No. NKCR)  
C-Tick not required  
Front-mounted auxiliary contact:  
– Permanently fixed  
– Protective cover to prevent manual operation  
– Red contact housing for easy identification  
– Incorporates IEC 60947-5-1 “Mechanically Linked” symbol  
AC and DC operating coils  
Your order m ust include:  
Catalogue number of the relays required, complete with coil  
suffix.  
SUVA third-party certification  
Catalogue number of adder decks, timers and accessories  
required.  
If required, the part number of replacement coils.  
9-17  
Contactors & Control Relays  
Safety Control Relays  
700S-CF  
Product Selection  
Type CF Control Relays — 8-Pole AC Coil Voltage  
AC-12  
AC-15  
Connection Diagram s  
Contacts  
I
[A]  
I [A]  
e
th  
Main  
Contacts  
Auxiliary  
Contacts  
Catalogue  
Num ber !  
24/  
40°C 60°C 48V 120V 240V 400V 500V 600V 690V  
NO  
NC  
53  
61  
71  
81  
82  
13  
14  
21  
22  
33  
43  
44  
A1  
A2  
K1  
K1  
K1  
700S-CF440  
700S-CF530  
700S-CF620  
C
C
C
4
4
34  
54  
62  
72  
Main  
Contacts  
20  
10  
20  
10  
10  
10  
6
3
2.5  
1.6  
1
1
1
1
53  
61  
71  
83  
13  
14  
21  
22  
33  
34  
43  
44  
A1  
A2  
5
6
3
2
54  
53  
62  
61  
72  
73  
84  
83  
13  
14  
21  
22  
33  
34  
43  
44  
Adder  
Deck  
Contacts  
A1  
A2  
6
6
6
5
54  
62  
74  
84  
! All Catalogue Numbers are factory-stocked.  
AC Coil Voltage Code  
The Catalogue Number is incomplete. Select a coil voltage code from the table below to complete the Catalogue Number. Example: 120V 60 Hz:  
Catalogue Number 700S-CF440 C becomes Catalogue Number 700S-CF440DC.  
100-  
110  
200-  
220  
208- 220-  
Voltage  
50 Hz  
12  
R
24  
K
32  
V
36  
W
V
42  
X
48  
Y
100  
KP  
110  
D
120  
P
127  
S
200  
KG  
208  
240  
230  
KP  
L
F
60 Hz  
Q
J
X
D
KG  
KL  
H
L
50/60 Hz  
KJ  
KY  
KP  
KD  
KG  
KL  
230-  
240  
380-  
400  
400-  
415  
Voltage  
50 Hz  
230  
240  
277  
347  
380  
400  
440  
480  
500  
550  
600  
VA  
T
A
I
E
N
G
B
N
M
C
60 Hz  
T
B
C
50/60 Hz  
KF  
KA  
KN  
KB  
9-18  
Contactors & Control Relays  
Safety Control Relays  
700S-CF  
Product Selection  
Type CF Control Relays — 8-Pole DC Coil Voltage  
AC-12  
AC-15  
Connection Diagram s  
Contacts  
I
[A]  
I [A]  
e
th  
Main  
Contacts  
Auxiliary  
Contacts  
Catalogue  
Num ber !  
24/  
40°C 60°C 48V 120V 240V 400V 500V 600V 690V  
NO  
NC  
53  
61  
71  
81  
82  
13  
21  
33  
43  
44  
A1  
A2  
K1  
K1  
K1  
700S-CF440  
700S-CF530  
700S-CF620  
C
C
C
4
4
14  
22  
34  
54  
62  
72  
Main  
Contacts  
20  
10  
20  
10  
10  
10  
6
3
2.5  
1.6  
1
1
1
1
53  
61  
71  
83  
13  
14  
21  
22  
33  
34  
43  
44  
A1  
A2  
5
6
3
2
54  
53  
62  
61  
72  
73  
84  
83  
13  
14  
21  
22  
33  
34  
43  
44  
Adder  
Deck  
Contacts  
A1  
A2  
6
6
6
5
54  
62  
74  
84  
! All Catalogue Numbers are factory-stocked.  
DC Coil Voltage Code  
The Catalogue Number is incomplete. Select a coil voltage code from the table below to complete the Catalogue Number. Example: 24V DC:  
Catalogue Number 700S-CF440 C becomes Catalogue Number 700S-CF440ZJC .  
Voltage  
9
12  
24  
ZJ  
36  
48  
60  
64  
72  
80  
110  
ZD  
115  
ZP  
125  
ZS  
220  
ZA  
230  
ZF  
250  
ZT  
Standard  
ZR  
ZQ  
ZW  
ZY  
ZZ  
ZB  
ZG  
ZE  
With diode  
suppressor  
DJ  
9-19  
Contactors & Control Relays  
Safety Control Relays  
100S-C and 700S-CF  
General  
Mechanically Linked Contacts  
Yes!  
State of N.C. Contacts if N.O. contact welds  
Aux.  
Contact  
(Front-  
Location of  
welded  
N.O.  
Catalogue  
Num ber  
700S-CF  
Main  
Front aux.  
m ounted)  
contacts  
Contact Ratings — NEMA  
A600, P600 A600, Q600  
10 mA  
Main  
Open  
Open  
Open  
17V  
24V  
48V  
Minimum Contact Rating  
Front aux. Open  
Left side  
aux.  
10A  
10A  
6A  
6A  
Open !  
Open  
Open  
Contact Ratings — IEC  
120V  
240V  
AC-15 (solenoids,  
contactors) at rated  
voltage  
10A  
10A  
6A  
5A  
Right side  
aux.  
Open !  
! Side-mounted auxiliary contacts provide “mirror contact” performance.  
Defined in IEC 60947-5-1 annex L. Positive guidance is a relationship between  
contacts of opposite types (i.e., N.O. and N.C.)  
400V  
480V/500V  
600V  
6A  
2.5A  
1A  
3A  
1.6A  
1A  
General  
690V  
1A  
1A  
Aux.  
I
Catalogue  
Num ber  
700S-CF  
Contact  
(Front-  
m ntd.)  
th  
20A  
10A  
40ºC  
230V  
400V  
690V  
AC-12 (Non-inductive, or  
slightly inductive loads,  
resistance furnaces)  
8 kW  
14 kW  
24 kW  
Mechanical Life  
Electrical Life  
[Mil]  
[Mil]  
15  
15  
AC-15  
(240V, 3A)  
1.5  
1.5  
60º C  
AC Op.  
Mechanism  
I
20A  
8 kW  
6A  
Weight  
[g]  
390  
th  
230V  
400V  
690V  
Te r m i nal C ro s s-  
Sections  
14 kW  
24 kW  
Te r m i nal Ty pe  
Switching DC Loads  
Te r m i nal S i ze  
per IEC 60947-1  
24V  
48V  
2 x A4  
2 x A4  
12A  
9A  
12A  
9A  
DC-12  
Flex.  
with  
Wire  
End  
L
110V  
/
< 1ms, Resistive Loads  
3.5A  
3.5A  
R
1 Conductor [mm2]  
2 Conductor [mm2]  
1…4  
1…4  
0.5…2.5  
0.75…2.5  
220V  
440V  
24V  
0.55A  
0.2A  
9A  
0.55A  
0.2A  
9A  
Ferrule  
Solid  
1 Conductor [mm2]  
2 Conductor [mm2]  
1.5…6  
1.5…6  
0.5…2.5  
0.75…2.5  
DC-14  
L
48V  
/
< 15ms, Inductive  
5A  
2A  
5A  
2A  
R
Max. Wire Size  
per UL/CSA  
[AWG]  
[lb-in]  
[Nm]  
16…10  
8.9…22  
1…2.5  
18…14  
8.9…13.3  
1…1.5  
110V  
220V  
Loads  
with economy resistor in  
series  
Tightening  
Torque  
0.4A  
0.4A  
440V  
24V  
0.16A  
5A  
0.16A  
5A  
Tightening  
Torque  
48V  
3A  
3A  
DC-13  
Switching electromagnets  
110V  
220V  
440V  
1.2A  
0.6A  
0.3A  
1.2A  
0.6A  
0.15A  
9-20  
Contactors & Control Relays  
Safety Control Relays  
100S-C and 700S-CF  
General (continued)  
General (continued)  
Aux.Contact  
Catalogue Num ber 700S-CF  
(Side-m ounted)  
Rated Insulation Voltage U  
i
Contact Ratings — IEC  
AC-15 (solenoids, contactors) at rated  
voltage  
120V  
240V  
6
5
IEC  
690V  
600V  
8 kV  
UL; CSA  
Rated Impulse Strength U  
imp  
IEC 60947  
400V  
500V  
3
High Test Voltage  
1.6  
1 minute (per IEC 947-4)  
2500V  
AC-12 (Non-inductive, or  
slightly inductive loads,  
resistance furnaces), IEC60947  
I
10A  
th  
40ºC  
60ºC  
Rated Voltage U  
e
I
6A  
3A  
th  
AC  
DC  
115, 230, 400, 500, 690V  
24, 48, 110, 220, 440V  
DC-13 (Solenoids and  
contactors), IEC60947  
24V  
48V  
1.5A  
Short-Circuit Protection IEC 158-  
1 Fuse, gG  
10A  
110V  
220V  
440V  
[AWG]  
[lb-in]  
[Nm]  
0.6A  
Rated Frequency  
50/60 Hz, DC  
0.3A  
Ambient Temperature  
Storage  
0.2A  
–55…+80 °C (–67…176 °F)  
–25…+60 °C (–13…140 °F)  
Max. Wire Size per UL/CSA  
Tightening Torque  
18…14  
8.9…13.3  
1…1.5  
Operation at nominal current  
Conditioned 15% current  
reduction after AC-1 at > 60°C  
Tightening Torque  
–25…+70 °C (–13…158 °F)  
Control Circuit  
humid-alternating climate,  
cyclic, per IEC 68-2-30 and  
DIN 50 016, 56 cycles  
Corrosion Resistance  
Altitude  
Catalogue  
Num ber  
700S-CF  
2000m above mean sea level,  
per IEC 60947-4  
Operating Voltage  
Type of Protection  
[x U ]  
AC 50/60 Hz  
Pick-up  
Dropout  
Pick-up  
Dropout  
0.85…1.1  
0.3…0.6  
0.8…1.1  
0.1…0.6  
s
IP 2X (IEC 529 and DIN 40050)  
in connected state  
[x U ]  
s
safe from touch by fingers and back  
of hand per VDE 0106, Part 100  
Finger Protection  
[x U ]  
DC!  
s
[x U ]  
s
Coil  
Consumption  
AC 50/60 Hz  
Inrush  
[VA/W]  
[VA/W]  
[W]  
70/50  
8/2.6  
6.5  
Seal  
DC  
Inrush/Seal  
Operating Times  
AC 50/60 Hz  
Pick-up Time  
[ms]  
15…30  
10…60  
40…70  
7…15  
Dropout Time [ms]  
Pick-up Time [ms]  
Dropout Time [ms]  
DC  
! For 9V DC, code ZR, use operating voltage 0.65…1.3 x Us.  
For 24V DC, code ZJ or DJ, use operating voltage 0.7…1.25 x Us.  
9-21  
Contactors & Control Relays  
Safety Control Relays  
100S-C and 700S-CF  
Auxiliary Contacts  
For Use W ith  
Catalogue Num ber  
Catalogue  
Num ber  
Description  
NO  
NC  
Connection Diagram s  
-3  
- 4  
Auxiliary Contact Blocks for Side  
Mounting without Sequence  
Terminal Designations !  
• 1- and 2-pole  
100S-C all  
700S-CF all  
100-SA10  
100-SA20  
100-SB10  
1
0
-4  
- 3  
-SA10  
Two-way numbering for right or left  
mounting on the contactor  
Quick and easy mounting without  
tools  
Electronic-compatible contacts down  
to 17V, 10mA  
-3 -3  
- 4 - 4  
-4 -4  
- 3 - 3  
100S-C AC only  
700S-CF AC only  
2
0
-SA20  
13  
4 4  
Auxiliary Contact Blocks for Side  
Mounting with Sequence Terminal  
Designations !  
100S-C09…C23  
700S-CF all➋  
1
0
14  
4 3  
• 1- and 2-pole  
Two-way numbering for right or left  
mounting on the contactor  
Quick and easy mounting without  
tools  
-SB10  
13 23  
4 4 3 4  
Electronic compatible contacts down  
to 17V, 10mA  
• L = Late break/Early make  
14 24  
4 3 3 3  
100S-C09…C23 AC only  
700S-CF AC only➋  
2
0
100-SB20  
-SB20  
! AC Coils: Max. 2 N.O. auxiliary contacts may be mounted on the side. DC coils: Max. 1 N.O. auxiliary contact may be mounted on the side. No additional N.C. auxiliary  
contacts may be added to safety contactors and control relays listed in this publication. For additional contact configurations, consult your local Rockwell Automation/Allen-  
Bradley distributor.  
Double Numbering — Left-side mounting only is recommended for Catalogue Number 700S-CF… due to double numbering.  
Marking Systems  
Uniform labelling materials for contactors, motor starting equipment, timing relays and circuit breakers  
Catalogue  
Description  
Package Q ty.  
Num ber  
Label Sheet  
100-FMS  
10  
• Sheet with 105 self-adhesive paper labels, 6 x 17 mm  
Marking Tag Sheet  
• Sheet with 160 perforated paper labels, 6 x 17 mm  
To be used with a transparent cover  
100-FMP  
10  
Transparent Cover  
To be used with marking tag sheets  
100-FMC  
100-FMA1  
100-FMA2  
100  
100  
100  
System V4/V5  
Marking Tag Adaptors  
• 100 each  
To be used with marking tag:  
System Bul. 1492W  
9-22  
Contactors & Control Relays  
Safety Control Relays  
100S-C and 700S-CF  
Control Modules  
For Use W ith  
Connection  
Diagram s  
Catalogue  
Num ber  
Catalogue  
Num ber  
Description  
DC Interface (electronic)  
• Interface between the DC control signal (PLC) and the contactor  
AC operating mechanism  
• Control voltage 18…30V DC (24V DC nominal)  
• For coil voltage of 110… 240V AC  
• Suitable for all 100S-C contactor sizes, 9…85 A  
• Requires no additional surge suppression for the coils  
• Power consumption  
100S-C with AC coils  
700S-CF with AC  
coils  
100-JE  
K1M  
– 0.1 W at 18V DC  
(K1M)  
– 0.25 W at 24V DC  
– 0.5 W at 30V DC  
100-FSC48  
100-FSC280  
100-FSC480  
RC Module  
AC Operating  
Mechanism  
24…48V, 50/60 Hz  
110…280V, 50/60 Hz  
380…480V, 50/60 Hz  
100S-C with AC coils  
700S-CF with AC  
coils  
Surge Suppressors  
For limitation of coil  
switching transients.  
• Plug-in, coil mounted  
• Suitable for all 100S-C  
contactor sizes, 9…85  
A
Varistor  
Module  
AC/DC  
Operating  
Mechanism  
12…55V AC/12…77V DC  
56…136V AC /78…180V DC  
137…277V AC /181…350V  
DC  
100-FSV55  
100-FSV136  
100-FSV277  
100-FSV575  
100S-C all  
700S-CF all  
278…575V AC  
• RC, Varistor and  
Diode Versions  
Diode Module  
DC Operating  
Mechanism  
100S-C with DC coils  
700S-CF with  
DC coils  
100-FSD250  
12…250V DC  
9-23  
Contactors & Control Relays  
Safety Control Relays  
100-D  
Auxiliary Contacts  
For Use with  
Catalogue  
Num ber  
Connection  
Diagram s  
Catalogue  
Num ber  
Description  
NO  
NC  
100-D  
Left or right  
outside mounting  
100-DS2-11  
100-DS2-20  
1
1
• Side-mounted  
With IEC sequence terminal designations  
53 63  
8 4 7 4  
100-D  
Left or right  
2
1
0
1
54 64  
8 3 7 3  
outside mounting  
Electronically compatible auxiliary contacts  
• Ideal for use when switching low-power control  
circuits  
100-D  
Left or right  
outside mounting  
100-DS2-B11  
• Contact ratings:  
AC-1  
AC-15, DC-13  
250V, 0.1 A  
3…125V, 1…100V,  
Labeling Material  
• Uniform labeling materials for contactors, motor protection devices, timing relays, and circuit breakers.  
Marking Systems (for 100-D95...D860 contactors)  
Catalogue  
Num ber  
Description  
Package Q ty.  
Label Sheet  
100-FMS  
10  
• 10 sheets with 105 self-adhesive paper labels each, 6 x 17mm  
Marking Tag Sheet  
• 10 sheets with 160 perforated paper labels each, 6 x 17mm  
To be used with a transparent cover  
100-FMP  
100-FMC  
10  
Transparent Cover  
• 100 each  
100  
To be used with marking tag sheets  
Marking Tag Adaptors  
• 100 each  
100-FMA1  
100-FMA2  
System V4/V5  
System Bul. 1492W  
100  
100  
To be used with marking tag:  
9-24  
Contactors & Control Relays  
Safety Control Relays  
100S-C and 700S-CF  
Auxiliary Contacts  
Internal Auxiliar y Contacts  
Catalogue Num bers  
Side-Mounted Auxiliar y Contacts  
Catalogue Num bers  
100S-C09...100S-C23  
100-SA, 100-SB, 100-MC  
Current Switching  
AC-12 I  
at 40°C  
at 60°C  
[A]  
[A]  
25  
20  
10  
6
th  
AC-15 at Rated Operating Voltage  
DC-13 at Rated Operating Voltage  
Continuous Current Rating per UL/CSA  
[V] 24 48 120 240 400 415 500 690 24 48 120 240 400 415 500 690  
[A] 10 10 10 10 2.5 1 2.5 1.6  
[V] 24 48 110 220 400  
6
5
6
6
6
5
3
1
24 48 110 220 400  
0.7 0.25 0.12  
[A]  
5
2
0.7 0.25 0.12  
5
2
[A]  
[A]  
AC  
DC  
10A, 600V (NEMA A600)  
5A, 600V (NEMA P600)  
10A, 600V (NEMA A600)  
2.5A, 600V (NEMA Q600)  
Short-Circuit Protection  
gG Fuse  
[A]  
Type 2 Coordination  
10  
8
10  
6
Rated Im pulse Voltage U  
[kV]  
imp  
Insulation Voltage (between control and load circuit) per  
DIN, VDE 0106, Part 101 (NAMUR recommendation)  
[V]  
250  
500  
Contact reliability per DIN 19240 without contamination, normal  
industrial atmosphere  
17V, 10mA  
17V, 10mA  
100-SA, 100-SB: Mirror output  
performance per IEC60947-4 Annex F  
100-MC: Mutually unrestricted  
Mechanically Linked Contacts per IEC  
60947-5-1 Annex L (SUVA Third-party  
certified)  
Mutually unrestricted between  
all N.O. and N.C. contacts  
between all N.O. and N.C. contacts  
Terminals  
Terminal Type  
2 x A4  
2 x A4  
Wire Size per IEC 60947-1  
2
1 Conductor  
2 Conductor  
1 Conductor  
2 Conductor  
[mm ]  
14  
14  
0.52.5  
0.752.5  
0.52.5  
Flexible w/Wire-End Ferrule  
2
[mm ]  
2
[mm ]  
1.56  
1.56  
Solid/Stranded Conductor  
2
0.752.5  
[mm ]  
Nm  
[AWG]  
[lb-in]  
Recommended Tightening Torque (min...max)  
Wire Size per UL/CSA  
Recommended Tightening Torque (min...max)  
1...2.5  
1610  
8.922  
11.5  
1814  
8.913.3  
9-25  
Contactors & Control Relays  
Safety Control Relays  
100-DS2  
Auxiliary Contacts  
Side-Mounted Auxiliary Contacts  
Catalogue Num bers  
100-DS2  
Conventional  
Electronically Com patible  
Current Switching  
AC-12 I  
at 40°C  
at 60°C  
[A]  
[A]  
16  
12  
0.1 at 250V  
th  
AC-15 at Rated Operating Voltage  
DC-13 at Rated Operating Voltage  
Continuous Current Rating per UL/CSA  
[V] 230 240 400 415 500 690  
[A]  
[V]  
[A]  
5.5  
24 48 110 220 440  
0.7 0.25 0.12  
5
3
2.5 1.6  
1
1… 100mA  
at 3… 125V  
5
2
[A]  
[A]  
AC  
DC  
10A, 600V (NEMA A600)  
2.5A, 600V (NEMA Q600)  
Short-Circuit Protection  
gG Fuse  
[A]  
Type 2 Coordination  
10  
8
Rated Im pulse Voltage U  
[kV]  
imp  
Insulation Voltage (between control and load circuit) per  
DIN, VDE 0106, Part 101 (NAMUR recommendation)  
[V]  
Contact reliability per DIN 19240 without contamination, normal  
industrial atmosphere  
17V, 5mA  
17V, 1mA  
Mechanically Linked Contacts per IEC  
60947-5-1 Annex L (SUVA Third-party  
certified)  
Mirror contact performance per IEC  
60947-4 Annex F  
Mirror contact performance per IEC  
60947-4 Annex F  
Te r m i nal s  
Te r m i nal Ty pe  
2 x A4  
2 x A4  
Wire Size per IEC 60947-1  
2
1 Conductor  
2 Conductor  
1 Conductor  
2 Conductor  
[mm ]  
12.5  
12.5  
14  
12.5  
12.5  
14  
Flexible w/Wire-End Ferrule  
2
[mm ]  
2
[mm ]  
Solid/Stranded Conductor  
2
14  
14  
[mm ]  
Nm  
[AWG]  
[lb-in]  
Recommended Tightening Torque (min...max)  
Wire Size per UL/CSA  
Recommended Tightening Torque (min...max)  
1.42.3  
1612  
1220  
1.42.3  
1612  
1220  
9-26  
Contactors & Control Relays  
Safety Control Relays  
100S-C and 700S-CF  
Dimensions—mm (inches)  
Dimensions are not intended for manufacturing purposes.  
Mounting Position  
c2  
AC Contactors and Control Relays  
DC Contactors and Control Relays  
c1  
c
AC Contactors and Control Relays  
a
b
c
c1  
c2  
d
d1  
d2  
Catalogue Num ber  
45  
(1-25/32)  
81  
(3-3/16)  
119.5  
(4-3/4)  
114.5  
(4-43/64)  
6
(1/4)  
2 - 4.5  
(2 - 3/16)  
60  
(2-23/64)  
35  
(1-25/64)  
100S-C09…100S-C23, 700S-CF  
45  
(1-25/32)  
81  
(3-3/16)  
136.5  
(5-37/64)  
131.6  
(5-11/32)  
6.5  
(17/64)  
2 - 4.5  
(2 - 3/16)  
60  
(2-23/64)  
35  
(1-25/64)  
100S-C30, 100S-C37  
100S-C43  
54  
(2-1/8)  
81  
(3-3/16)  
139.5  
(5-11/16)  
134.6  
(5-29/64)  
6.5  
(17/64)  
2 - 4.5  
(2 - 3/16)  
60  
(2-23/64)  
45  
(1-25/32)  
72  
(2-53/64)  
122  
(4-51/64)  
156  
(6-11/32)  
150.5  
(6-1/8)  
8.5  
(21/64)  
4 - 5.4  
(4 - 7/32)  
100  
(3-15/16)  
55  
(2-11/64)  
100S-C60100S-C85  
DC Contactors and Control Relays  
a
b
c
c1  
c2  
d
d1  
d2  
Catalogue Num ber  
100S-C09Z...100S-C16Z, 700S-  
CF  
45  
(1-25/32)  
81  
(3-3/16)  
145.5  
(5-49/64)  
140.5  
(5-37/64)  
6
(1/4)  
2 - 4.5  
(2 -3/16)  
60  
(2-23/64)  
35  
(1-25/64)  
45  
(1-25/32)  
81  
(3-3/16)  
162.5  
(6-7/16)  
158  
(6-1/4)  
6
(1/4)  
2 - 4.5  
(2 -3/16)  
60  
(2-23/64)  
35  
(1-25/64)  
100S-C23Z  
100S-C30...100S-C37  
100S-C43Z  
45  
(1-25/32)  
81  
(3-3/16)  
180.5  
(7-5/32)  
175.5  
(6-61/64)  
6.5  
(17/64)  
2 - 4.5  
(2 -3/16)  
60  
(2-23/64)  
35  
(1-25/64)  
54  
(2-1/8)  
81  
(3-3/16)  
183.5  
(7-17/64)  
179  
(7-3/32)  
6.5  
(17/64)  
2 - 4.5  
(2 -3/16)  
60  
(2-23/64)  
45  
(1-25/32)  
72  
(2-53/64)  
122  
(4-51/64)  
156  
(6-11/32)  
150.5  
(6-1/8)  
8.5  
(21/64)  
4 - 5.4  
(4 -7/32)  
100  
(3-15/16)  
55  
(2-11/64)  
100S-C60D...100S-C85D  
Accessories  
Contactors with  
m m  
a + 9  
b + 24  
a + 9  
b + 9  
b + 3  
(inches)  
(a + 23/64)  
(b + 15/16)  
(a + 23/64)  
(b + 23/64)  
(b + 1/8)  
Auxiliary contact block for side mounting 1- or 2-pole  
Electronic Timing Module on coil terminal side  
Mechanical Interlock on side of contactor  
Interface Module on coil terminal side  
Surge Suppressor on coil terminal side  
Labelling with label sheet  
+ 0  
+ 0  
+ 5.5  
+ 5.5  
(+ 0)  
(+ 0)  
(+ 7/32)  
(+ 7/32)  
marking tag sheet with clear cover  
marking tag adapter for System V4/V5  
marking tag adapter for System Bul. 1492W  
9-27  
Contactors & Control Relays  
Safety Control Relays  
100S-D Contactors and Accessories  
Dimensions—mm (inches)  
Dimensions are not intended for manufacturing purposes.  
Mounting Position  
e2  
c1  
e1  
øe  
ød  
d2  
a
c
Catalogue Num ber  
a
b
c
c1  
ød  
5.2  
5.2  
6.5  
10  
d1  
d2  
øe  
M6  
e1  
16  
20  
25  
40  
e2  
38.5  
39  
e3  
e4  
8
100S-D95, 100S-D110  
120  
120  
155  
255  
170  
170  
205  
310  
156  
156  
180  
265  
110.5  
110.5  
110.5  
110.5  
145  
145  
180  
230  
100  
100  
130  
225  
147  
160  
193  
291  
100S-D95-EI100S-D180-EI, 100S-D140, 100S-D180  
100S-D210-EI100S-D420-EI  
M8  
10  
M10  
M12  
48  
12.5  
22  
100S-D630-EI100S-D860-EI  
70  
Contactor with  
[m m ]  
Auxiliary contact block  
Mechanical interlock  
100-DS2…  
100-DM…  
a + 13.5 each  
a + a  
100-DTB110  
100-DTB180  
100-DTB420  
b + 7 each  
b + 7 each  
b + 8.5 each  
Frame terminal block  
Label holder  
c…+ 5  
Convention DC coil contactors will have an additional auxiliary contact block mounted which will add 13.5mm (0.53in) to the “a” dimension on the right hand side.  
9-28  

相关型号:

700S-CF530ZXC

Industrial Relays
ALLEN-BRADLEY

700S-CF620XC

Industrial Relays
ALLEN-BRADLEY

700S-CF620ZXC

Industrial Relays
ALLEN-BRADLEY

700S-DCP1020Z24

Safety Control Relays
ALLEN-BRADLEY

700S-DCP220Z24

Safety Control Relays
ALLEN-BRADLEY

700S-DCP310Z24

Safety Control Relays
ALLEN-BRADLEY

700S-DCP350Z24

Safety Control Relays
ALLEN-BRADLEY

700S-DCP440Z24

Safety Control Relays
ALLEN-BRADLEY

700S-DCP530Z24

Safety Control Relays
ALLEN-BRADLEY

700S-DCP620Z24

Safety Control Relays
ALLEN-BRADLEY

700S-DCP710Z24

Safety Control Relays
ALLEN-BRADLEY

700S-P

Safety Control Relays
ALLEN-BRADLEY