1C15UR [ALTECH]

Thermal Magnetic Circuit Breaker,;
1C15UR
型号: 1C15UR
厂家: ALTECH CORPORATION    ALTECH CORPORATION
描述:

Thermal Magnetic Circuit Breaker,

文件: 总8页 (文件大小:2181K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
UR Series  
UL1077 Recognized  
Supplementary Protector  
DIN Rail Mounted  
17.5mm width per pole  
Thermal Magnetic  
Current Limiting  
0.5-60A / 480Y/277V AC,  
50/60Hz  
10kA Short Circuit  
Withstand Capacity  
Applications (on the load side  
of Branch Circuit Protection)  
include: Sensitive Electronics,  
Power Supplies, Appliance  
circuits, etc.  
PENDING  
E137915  
UR - Series  
Voltage Rating  
0.5-60A / 480Y/277V AC  
0.5 - 10A (RC): 10 kA with no back-up fuse  
8 - 63A (RC): 10 kA with UL-listed Class J back-up fuse;  
5 kA with no back-up fuse  
Short Circuit Withstand Rating  
30ºC (86ºF)  
Calibration Temperature  
Ambient Temperature  
Storage Temperature  
Terminal Torque (min/max)  
Electrical Life  
-25ºC to +55ºC (-13ºF to 131ºF )  
-40ºC to +70ºC (-40ºF to 158ºF )  
2 Nm (17.7 lb.in.) / 2.5Nm (22.2 lb.in)  
6000 switching cycles ON/ OFF  
10000 switching cycles ON/ OFF  
Mechanical Life  
> 15g according to DIN EN 60069-2-59 during a load with 1.05 x I  
Vibration Resistance  
Resistance to mechanical shocks  
N
25g @ 11ms  
Short Circuit Withstand Ratings for R-Series Supplementary Protector  
Backup Protection  
Trip  
Amp  
UL-Listed  
Class J Fuse  
up to 10kA  
No Backup Fuse  
Curve  
Range  
Required  
up to:  
All  
0.5 - 10A  
12 - 60A  
70A  
10kA  
All  
4xRC*  
5kA  
*up to nearest rated current  
For the latest on Altech Circuit Breakers specifications please visit www.altechcorp.com/breaker.  
36  
9
Marking Details  
Rated Current  
Approval  
Trip Characteristic  
Voltage Rating  
No. of Poles  
Circuit Diagram  
Individual Part Number is shown  
Short Circut Withstand Rating  
Product Series  
44 mm  
37.5 mm  
25.5 mm  
Dimensions in mm  
6
7
8
4
17.5 mm  
35 mm  
52.5 mm  
14.5 mm  
30.5 mm  
44 mm  
68.4 mm  
1 Pole  
2 Pole  
3 Pole  
Application Overview  
Trip-Characteristics*  
Applications  
Characteristic Trip Boundaries  
Lighting  
Business  
Equipment  
Wiring  
Protection  
Control  
Control  
Transformers  
Power  
Supplies  
General  
Electronics  
Reactive  
Load  
Thermal Trip  
Magnetic Trip  
Appliances  
Must not Must Trip Must not Must Trip  
Circuits  
Trip>100ms  
<1hr  
Trip>100ms at 100ms  
B-Characteristics  
1.45xRC 3xRC  
C-Characteristics  
1.45xRC 5xRC  
D-Characteristics  
1.45xRC 10xRC  
1.13xRC  
1.13xRC  
1.13xRC  
5xRC  
10xRC  
20xRC  
*The value of each characteristic is shown vertically beneath its corresponding heading.  
Warning!  
This information should only be used as a selection guide.The use of a Miniature Circuit Breaker/Supplementary Protector  
in an application with a certainTrip-Characteristic always requires prototype testing! It is the responsibility of the circuit  
design engineer to select the appropriate Miniature Circuit Breaker/Supplementary Protector for his specific application.  
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com  
37  
URꢀ- Series  
Application Examples:  
B-Trip  
Business equipment, wiring protection, lighting, appliances, control  
circuits, some motors and some electronic applications. Relatively long  
thermal trip delay but low magnetic trip point.  
Characteristic  
C
US  
UL Recognized  
E137915  
One Pole  
Three Pole  
Rated  
Current  
0.5A  
1.0A  
2.0A  
3.0A  
4.0A  
5.0A  
6.0A  
8.0A  
10A  
Type/  
Rated  
Rated  
Current  
0.5A  
1.0A  
2.0A  
3.0A  
4.0A  
5.0A  
6.0A  
8.0A  
10A  
12A  
13A  
15A  
16A  
20A  
25A  
30A  
32A  
Type/  
Rated  
Cat. No.  
1B05UR  
1B1UR  
Voltage  
Cat. No.  
3B05UR  
3B1UR  
Voltage  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
1B2UR  
3B2UR  
1B3UR  
3B3UR  
1B4UR  
3B4UR  
1B5UR  
3B5UR  
1B6UR  
3B6UR  
Standard Pack: 12  
Standard Pack: 4  
1B8UR  
3B8UR  
Weight:  
Weight:  
1B10UR  
1B12UR  
1B13UR  
1B15UR  
1B16UR  
1B20UR  
1B25UR  
1B30UR  
1B32UR  
1B40UR  
1B50UR  
1B60UR  
1B63UR  
3B10UR  
3B12UR  
3B13UR  
3B15UR  
3B16UR  
3B20UR  
3B25UR  
3B30UR  
3B32UR  
3B40UR  
3B50UR  
3B60UR  
3B63UR  
0.3A - 32A  
0.3A - 32A  
12A  
13A  
15A  
16A  
20A  
25A  
30A  
32A  
40A  
50A  
60A  
63A*  
1.75kg (3.86 lb.)  
40A - 63A  
2.07kg (4.56 lb.)  
1.75kg (3.86 lb.)  
40A - 63A  
2.07kg (4.56 lb.)  
40A  
50A  
60A  
63A*  
Two Pole  
Add-on Neutral Pole  
Rated  
Current  
0.5A  
1.0A  
2.0A  
3.0A  
4.0A  
5.0A  
6.0A  
8.0A  
10A  
Type/  
Rated  
Rated  
Current  
0.3-63A  
Type/  
Cat. No.  
N63UM  
Rated  
Voltage  
Cat. No.  
2B05UR  
2B1UR  
Voltage  
480/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
Standard Pack: 6  
2B2UR  
2B3UR  
Weight:  
2B4UR  
0.775kg (1.71)  
2B5UR  
2B6UR  
Standard Pack: 6  
2B8UR  
Weight:  
2B10UR  
2B12UR  
2B13UR  
2B15UR  
2B16UR  
2B20UR  
2B25UR  
2B30UR  
2B32UR  
2B40UR  
2B50UR  
2B60UR  
2B63UR  
0.3A - 32A  
12A  
13A  
15A  
16A  
20A  
25A  
30A  
32A  
40A  
50A  
60A  
63A*  
Ring  
tongue  
Standard Dual  
1.75kg (3.86 lb.)  
40A - 63A  
2.07kg (4.56 lb.)  
Connection Terminal  
• Box clamp terminals  
Top: 18-3 AWG;  
Bottom: 18-2 AWG  
(Line/Load reversible)  
Box  
clamp  
• Ring tongue terminals  
11.3 mm  
(0.44 in.)  
18.3 mm  
(0.72 in.)  
M5 screw  
* May differ by manufacturer. Top terminal ring tongue max. thickness 1.6mm.  
*63A is not UL Recognized.  
For the latest on Altech Circuit Breakers specifications please visit www.altechcorp.com/breaker.  
38  
URꢀ- Series  
Application Examples:  
C-Trip  
Low inrush motors, lighting, wiring protection, appliances,  
business equipment, and control circuit applications. Relatively  
long thermal trip delay and medium magnetic trip point.  
Characteristic  
C
US  
UL Recognized  
E137915  
One Pole  
Three Pole  
Rated  
Current  
0.5A  
1.0A  
2.0A  
3.0A  
4.0A  
5.0A  
6.0A  
8.0A  
10A  
Type/  
Rated  
Rated  
Type/  
Rated  
Cat. No.  
1C05UR  
1C1UR  
Voltage  
Current Cat. No.  
Voltage  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
0.5A  
1.0A  
2.0A  
3.0A  
4.0A  
5.0A  
6.0A  
8.0A  
10A  
12A  
13A  
15A  
16A  
20A  
25A  
30A  
32A  
40A  
50A  
60A  
63A*  
3C05UR 480Y/277V AC  
3C1UR  
3C2UR  
3C3UR  
3C4UR  
3C5UR  
3C6UR  
3C8UR  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
1C2UR  
1C3UR  
1C4UR  
1C5UR  
1C6UR  
Standard Pack: 12  
Standard Pack: 4  
1C8UR  
Weight:  
Weight:  
1C10UR  
1C12UR  
1C13UR  
1C15UR  
1C16UR  
1C20UR  
1C25UR  
1C30UR  
1C32UR  
1C40UR  
1C50UR  
1C60UR  
1C63UR  
3C10UR 480Y/277V AC  
3C12UR 480Y/277V AC  
3C13UR 480Y/277V AC  
3C15UR 480Y/277V AC  
3C16UR 480Y/277V AC  
3C20UR 480Y/277V AC  
3C25UR 480Y/277V AC  
3C30UR 480Y/277V AC  
3C32UR 480Y/277V AC  
3C40UR 480Y/277V AC  
3C50UR 480Y/277V AC  
3C60UR 480Y/277V AC  
3C63UR 480Y/277V AC  
0.3A - 32A  
0.3A - 32A  
12A  
13A  
15A  
16A  
20A  
25A  
30A  
32A  
40A  
50A  
60A  
63A*  
1.75kg (3.86 lb.)  
40A - 63A  
2.07kg (4.56 lb.)  
1.75kg (3.86 lb.)  
40A - 63A  
2.07kg (4.56 lb.)  
Two Pole  
Add-on Neutral Pole  
Rated  
Current  
0.5A  
1.0A  
2.0A  
3.0A  
4.0A  
5.0A  
6.0A  
8.0A  
10A  
Type/  
Rated  
Rated  
Current  
0.3-63A  
Type/  
Rated  
Cat. No.  
2C05UR  
2C1UR  
Voltage  
Cat. No.  
Voltage  
N63UM 480/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
Standard Pack: 6  
2C2UR  
2C3UR  
Weight:  
2C4UR  
0.775kg (1.71)  
2C5UR  
2C6UR  
Standard Pack: 6  
2C8UR  
Weight:  
2C10UR  
2C12UR  
2C13UR  
2C15UR  
2C16UR  
2C20UR  
2C25UR  
2C30UR  
2C32UR  
2C40UR  
2C50UR  
2C60UR  
2C63UR  
0.3A - 32A  
12A  
13A  
15A  
16A  
20A  
25A  
30A  
32A  
40A  
50A  
60A  
63A*  
Ring  
tongue  
Standard Dual  
1.75kg (3.86 lb.)  
40A - 63A  
2.07kg (4.56 lb.)  
Connection Terminal  
• Box clamp terminals  
Top: 18-3 AWG;  
Bottom: 18-2 AWG  
(Line/Load reversible)  
Box  
clamp  
• Ring tongue terminals  
11.3 mm  
(0.44 in.)  
18.3 mm  
(0.72 in.)  
M5 screw  
* May differ by manufacturer. Top terminal ring tongue max. thickness 1.6mm.  
*63A is not UL Recognized.  
Altech Corp.® ꢀ 35 Royal Road ꢀ Flemington, NJ 08822-6000 ꢀ Phone (908)806-940  
0 ꢀ FAX (908)806-9490  
39  
URꢀ- Series  
Application Examples:  
D-Trip  
Control transformers, power supplies, reactive loads. Relatively long  
thermal trip delay and very high magnetic trip point.  
Characteristic  
C
US  
UL Recognized  
E137915  
One Pole  
Three Pole  
Rated  
Current  
0.5A  
1.0A  
2.0A  
3.0A  
4.0A  
5.0A  
6.0A  
8.0A  
10A  
Type/  
Rated  
Rated  
Current  
0.5A  
1.0A  
2.0A  
3.0A  
4.0A  
5.0A  
6.0A  
8.0A  
10A  
Type/  
Rated  
Cat. No.  
1D05UR  
1D1UR  
Voltage  
Cat. No.  
3D05UR  
3D1UR  
Voltage  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
1D2UR  
3D2UR  
1D3UR  
3D3UR  
1D4UR  
3D4UR  
1D5UR  
3D5UR  
1D6UR  
3D6UR  
Standard Pack: 12  
Standard Pack: 4  
1D8UR  
3D8UR  
Weight:  
Weight:  
1D10UR  
1D12UR  
1D13UR  
1D15UR  
1D16UR  
1D20UR  
1D25UR  
1D30UR  
1D32UR  
1D40UR  
1D50UR  
1D60UR  
1D63UR  
3D10UR  
3D12UR  
3D13UR  
3D15UR  
3D16UR  
3D20UR  
3D25UR  
3D30UR  
3D32UR  
3D40UR  
3D50UR  
3D60UR  
3D63UR  
0.3A - 32A  
0.3A - 32A  
12A  
13A  
15A  
16A  
20A  
25A  
30A  
32A  
40A  
50A  
60A  
63A*  
12A  
13A  
15A  
16A  
1.75kg (3.86 lb.)  
40A - 63A  
2.07kg (4.56 lb.)  
1.75kg (3.86 lb.)  
40A - 63A  
2.07kg (4.56 lb.)  
20A  
25A  
30A  
32A  
40A  
50A  
60A  
63A*  
Two Pole  
Add-on Neutral Pole  
Rated  
Current  
0.5A  
1.0A  
2.0A  
3.0A  
4.0A  
5.0A  
6.0A  
8.0A  
10A  
Type/  
Rated  
Rated  
Current  
0.3-63A  
Type/  
Cat. No.  
N63UM  
Rated  
Voltage  
Cat. No.  
2D05UR  
2D1UR  
Voltage  
480/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
480Y/277V AC  
Standard Pack: 6  
2D2UR  
2D3UR  
Weight:  
2D4UR  
0.775kg (1.71)  
2D5UR  
2D6UR  
Standard Pack: 6  
2D8UR  
Weight:  
2D10UR  
2D12UR  
2D13UR  
2D15UR  
2D16UR  
2D20UR  
2D25UR  
2D30UR  
2D32UR  
2D40UR  
2D50UR  
2D60UR  
2D63UR  
0.3A - 32A  
12A  
13A  
15A  
16A  
20A  
25A  
30A  
32A  
40A  
50A  
60A  
63A*  
Ring  
tongue  
Standard Dual  
1.75kg (3.86 lb.)  
40A - 63A  
2.07kg (4.56 lb.)  
Connection Terminal  
• Box clamp terminals  
Top: 18-3 AWG;  
Bottom: 18-2 AWG  
(Line/Load reversible)  
Box  
clamp  
• Ring tongue terminals  
11.3 mm  
(0.44 in.)  
18.3 mm  
(0.72 in.)  
M5 screw  
* May differ by manufacturer. Top terminal ring tongue max. thickness 1.6mm.  
*63A is not UL Recognized.  
For the latest on Altech Circuit Breakers specifications please visit www.altechcorp.com/breaker.  
40  
For mounting instructions  
please refer to page 43.  
UR Series Accessories  
C
US  
UL Listed  
E137938  
Auxiliary Contact, Alarm Switch  
Type/ Cat No.  
Description  
Contacts Type Std Pk  
H10UM  
H11UM  
H12UM  
H21UM  
HLS11M*  
1 Auxiliary Contact  
2 Auxiliary Contacts  
3 Auxiliary Contacts  
3 Auxiliary Contacts  
1 Auxiliary/  
1NO  
1NO + 1NC  
1NO + 2NC  
6
6
6
6
6
6 mm  
2NO + 1NC  
1CO + 1CO (Signal)  
63.8 mm  
8.8 mm  
1 Signal Contacts  
Dimensions HxxUM.  
Rated Operating  
Currents  
10A@240V AC  
3A@110V DC  
68.4 mm  
9 mm  
1A@220V DC  
1mA @ 24V DC  
max. 0.8Nm (7 lb.in)  
43.8 mm  
Minimum Contact Load  
Torque  
Wire Range:  
Single Wire  
Stranded Wire  
Stranded Wire  
with Ferrule  
1.0mm² - 2.5mm² (18-14 AWG)  
1.0mm² - 1.5mm² (18-16 AWG)  
1.0mm² - 1.5mm² (18-16 AWG)  
Shunt Trip  
Max. Operating  
Type/ Cat No. Rated Voltage UN  
Current @ UN  
Std Pk  
63.8 mm  
12.4 mm  
6 mm  
FA12UM  
FA24UM  
FA48UM  
12V AC/DC  
24V AC/DC  
48 - 72V AC/DC  
1.3A  
0.6A  
0.2A  
5
5
5
Dimensions HLS11M.  
21.8 mm  
0.25A @ 110V  
0.5A @ 240V  
0.58A @ 277V  
AWG 23  
FA110UM  
5
110 - 240 V AC/DC,  
277V AC  
Undervoltage Trip*  
Type/ Cat No.  
Line Voltage VE  
120V AC, 60Hz  
Std Pk  
UA120UM  
5
Reset-Hold Voltage = 0.85 x VE  
Drop-Out Voltage = 0.35 ~ 0.7 x VE  
VE = Rated Voltage  
43.6 mm  
6 mm  
17.5 mm  
68.4 mm  
Neutral Pole  
Dimensions UA120UM.  
Type/ Cat No. Rated Current IN Rated Voltage UN Std Pk  
44 mm  
37.5 mm  
N63UM  
0.3 - 63A  
480Y/277V AC  
6
25.5 mm  
6 mm  
7 mm  
Touch Protection Caps  
to cover the terminal screw holes on  
the switching devices, neutral Poles  
and shunt trips for increased touch  
protection.  
Cooling Spacer  
Type/ Cat No.  
Std Pk  
Type/ Cat No.  
Std Pk  
BS.UL  
100  
15.960  
1
Mounting Screw 34mm  
8 mm  
14.5 mm  
4 mm  
to connect the auxiliary contact and shunt  
trip or neutral Pole to the circuit breaker.  
17.5 mm  
Lock-out Adapter**  
Type/ Cat No. Std Pk  
30.5 mm  
44 mm  
68.4 mm  
Type/ Cat No.  
Std Pk  
E983419  
10  
EASS  
10  
Dimensions N63UM, FAxxUM.  
* UL Pending  
** UR series can also be locked in the on and off position by simply using a  
common lead or meter seal, which gets fed through the hole in the handle  
and a corresponding hole in the housing.  
Altech Corp.® ꢀ 35 Royal Road ꢀ Flemington, NJ 08822-6000 ꢀ Phone (908)806-940  
0 ꢀ FAX (908)806-9490  
41  
UR Series Trip Curves  
B Trip Curve  
C Trip Curve  
D Trip Curve  
1.13-1.45xIN  
1.13-1.45xIN  
1.13-1.45xIN  
60  
40  
60  
40  
60  
40  
10  
10  
4
10  
Thermal Overload  
“Must Trip” < 1 hr = 145% RC  
“Must Not Trip” > 1 hr = 113% RC  
Thermal Overload  
“Must Trip” < 1 hr = 145% RC  
“Must Not Trip” > 1 hr = 113% RC  
Thermal Overload  
“Must Trip” < 1 hr = 145% RC  
“Must Not Trip” > 1 hr = 113% RC  
4
4
1
1
1
10  
4
10  
4
10  
4
1
1
1
0.4  
0.4  
0.4  
10-1  
10-1  
10-1  
4x10-2  
4x10-2  
4x10-2  
10-2  
10-2  
10-2  
4x10-3  
4x10-3  
4x10-3  
10-3  
10-3  
10-3  
1
2
3
4
5 6 8 10  
20  
40  
100  
1
2
3
4
5 6 8 10 1620  
40  
100  
1
2
3
4
5 6 8 10  
20  
40  
100  
Multiple of Rated Current  
Multiple of Rated Current  
Multiple of Rated Current  
0.5A Through 10A Rated Current  
0.3A Through 10A Rated Current  
0.5A Through 10A Rated Current  
1.13-1.45xIN  
1.13-1.45xIN  
1.13-1.45xIN  
60  
40  
60  
40  
60  
40  
10  
4
10  
4
10  
4
Thermal Overload  
“Must Trip” < 1 hr = 145% RC  
“Must Not Trip” > 1 hr = 113% RC  
Thermal Overload  
“Must Trip” < 1 hr = 145% RC  
“Must Not Trip” > 1 hr = 113% RC  
Thermal Overload  
“Must Trip” < 1 hr = 145% RC  
“Must Not Trip” > 1 hr = 113% RC  
1
1
1
10  
4
10  
4
10  
4
1
1
1
0.4  
0.4  
0.4  
10-1  
10-1  
10-1  
4x10-2  
4x10-2  
4x10-2  
10-2  
10-2  
10-2  
4x10-3  
4x10-3  
4x10-3  
10-3  
10-3  
10-3  
1
2
3
4
5 6 8 10 1620  
40  
100  
1
2
3
4
5 6 8 10  
20  
40  
100  
1
2
3
4
5 6 8 10  
20  
40  
100  
Multiple of Rated Current  
Multiple of Rated Current  
Multiple of Rated Current  
12A Through 63A Rated Current  
12A Through 63A Rated Current  
12A Through 63A Rated Current  
“B” Magnetic Trip Parameters  
“C” Magnetic Trip Parameters  
“D” Magnetic Trip Parameters  
Rated current 0.5A to 63A.  
Rated current 0.5A to 63A.  
Rated current 0.5A to 63A.  
1. Hold for a minimum of 100ms at  
surge of 10 times rated current.  
1. Hold for a minimum of 100ms at  
surge of 3 times rated current.  
2. Trip in under 100ms at 5 times rated  
current.  
1. Hold for a minimum of 100ms at  
surge of 5 times rated current.  
2. Trip in under 100ms at 10 times  
rated current.  
2. Trip in under 100ms at 16 times  
rated current.  
UR Series Internal Resistance  
Rated Current  
Trip Characteristic  
(A)  
B
C
D
(Ohm)  
(Ohm)  
(Ohm)  
0.5  
1.0  
2.0  
3.0  
4.0  
5.0  
6.0  
8.0  
10  
12/ 13  
15/ 16  
20  
25  
30/ 32  
40  
8.0400  
1.7000  
0.4190  
0.2020  
0.1090  
0.0654  
0.0528  
0.0278  
0.0216  
0.0113  
0.0085  
0.0067  
0.0050  
0.0032  
0.0025  
0.0019  
0.0018  
6.8540  
1.7000  
0.4190  
0.2020  
0.1090  
0.0654  
0.0528  
0.0278  
0.0216  
0.0084  
0.0085  
0.0067  
0.0050  
0.0032  
0.0025  
0.0019  
0.0018  
6.0009  
1.7560  
0.4190  
0.2020  
0.1090  
0.0654  
0.0491  
0.0240  
0.0187  
0.0085  
0.0076  
0.0064  
0.0041  
0.0027  
0.0022  
0.0018  
0.0017  
50  
60/ 63*  
For the latest on Altech Circuit Breakers specifications please visit www.altechcorp.com/breaker.  
42  
Temperature Correction Curve (UL, DL, V-EA, MA and UR series)  
160  
150  
Ambient Temperature Adjustment  
5% of RC for every 10°C (18°F).  
140  
Adjacent Mounting Temperature  
Adjustment 3% of RC for every  
additional pole above 3.  
Maximum 20% off RC for a total  
of 10 poles or more.*  
130  
120  
110  
100  
90  
Ambient Temperature and  
Adjacent Mounting/  
Loading Adjustment  
Ambient Temperature 25°C to  
55°C, Storage Temperature -  
40°C to 70°C  
80  
70  
60  
Cooling spacer (Part #15.960)  
between each group of 3 poles  
will eliminate these adjustments.  
50  
40  
-40  
-40  
-30  
-22  
-20  
-4  
-10  
14  
0
32  
10  
50  
20  
68  
30  
86  
40  
104  
50  
122  
60  
140  
70  
158  
80  
176  
90 (°C)  
194 (°F)  
Ambient Temperature  
Accessory Mounting Instructions (UL, V-EA and UR series)  
Neutral / Shunt Trip  
Neutral Switch/  
Shunt Trip  
Switching  
Device  
Neutral Switch/  
Shunt Trip  
Auxiliary  
Contact  
+ Auxiliary Contact  
5.  
6.  
7mm  
Mounting screw  
34mm  
4.  
3.  
1.  
6.  
24 mm  
2.  
Neut r al Pol es N63UM, N32UL, N63UL or Shunt Tr i ps FA. . UM, FA. . UL can be mount ed on t he r i ght or l ef t  
si de of  
t he ci r cui t pr ot ect i on devi ce.  
1. Turn handle to off position.  
2. Remove gray cover from the circuit protection device and accessory.  
3. Insert linkage component between circuit protection device and neutral pole (N63UM, N32UL, N63UL) or shunt trip (FA..UM, FA..UL).  
4. Insert connecting pin into handle.  
5. Assemble circuit protection device and neutral pole (N63UM, N32UL, N63UL) or shunt trip (FA..UM, FL..UL).  
6. The auxiliary contact (H..UM, H..UL) can also be mounted on the right side by using a different screw  
(E983419; see accessory pages 14, 32 or 41).  
Auxiliary Contact  
Switching  
Device  
Auxiliary  
Contact  
Auxi l i ar y cont act can be mount ed on t he  
r i ght si de of  
3.  
90°  
4.  
t he ci r cui t pr ot ect i on devi ce onl y.  
1. Turn handles to OFF position.  
2. Remove gray cover from switching device.  
3. Combine circuit protection device and auxiliary contact  
(H...UM, H...UL).  
1.  
4. Insert mounting screws and connect the two devices  
by turning the screws 90° clockwise.  
2.  
Altech Corp.® ꢀ 35 Royal Road ꢀ Flemington, NJ 08822-6000 ꢀ Phone (908)806-940  
0 ꢀ FAX (908)806-9490  
43  

相关型号:

1C16UL

Thermal Magnetic Circuit Breaker,
ALTECH

1C16UR

Thermal Magnetic Circuit Breaker,
ALTECH

1C1801H

RESISTOR, TEMPERATURE DEPENDENT, NTC, 1800 ohm, THROUGH HOLE MOUNT, RADIAL LEADED
VISHAY

1C2001

RESISTOR, TEMPERATURE DEPENDENT, NTC, 2000 ohm, THROUGH HOLE MOUNT, RADIAL LEADED
VISHAY

1C2001-1

RESISTOR, TEMPERATURE DEPENDENT, NTC, 2000 ohm, THROUGH HOLE MOUNT, RADIAL LEADED
VISHAY

1C2001-2

RESISTOR, TEMPERATURE DEPENDENT, NTC, 2000 ohm, THROUGH HOLE MOUNT, RADIAL LEADED
VISHAY

1C2001-3

RESISTOR, TEMPERATURE DEPENDENT, NTC, 2000 ohm, THROUGH HOLE MOUNT, RADIAL LEADED
VISHAY

1C2001-5

RESISTOR, TEMPERATURE DEPENDENT, NTC, 2000 ohm, THROUGH HOLE MOUNT, RADIAL LEADED
VISHAY

1C2001F

RESISTOR, TEMPERATURE DEPENDENT, NTC, 2000 ohm, THROUGH HOLE MOUNT, RADIAL LEADED
VISHAY

1C2001J

RESISTOR, TEMPERATURE DEPENDENT, NTC, 2000 ohm, THROUGH HOLE MOUNT, CHIP
VISHAY

1C2001K

RESISTOR, TEMPERATURE DEPENDENT, NTC, 2000 ohm, THROUGH HOLE MOUNT, RADIAL LEADED
VISHAY

1C20C0G100J050B

Ceramic Capacitors
VISHAY