1DU63 [ALTECH]

Thermal Magnetic Circuit Breaker,;
1DU63
型号: 1DU63
厂家: ALTECH CORPORATION    ALTECH CORPORATION
描述:

Thermal Magnetic Circuit Breaker,

文件: 总1页 (文件大小:204K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
V-EA-Series - UL508 Manual Motor Controller - 1 pole D-Trip  
V-EA-D Trip  
0.3A Through 10A Rated Current  
1.13-1.45xIN  
Rated  
Current  
0.3A  
0.5A  
0.75A  
0.8A  
1.0A  
1.6A  
2.0A  
2.5A  
3.0A  
3.5A  
4.0A  
5.0A  
6.0A  
8.0A  
10A  
Type/  
Cat. No.  
1DU03  
1DU05  
1DU075  
NA  
Approvals  
U
UL508 Listed  
60  
40  
L
E137938  
U
L
10  
U
L
Thermal Overload  
“Must Trip” < 1 hr = 145% RC  
“Must Not Trip” > 1 hr = 113% RC  
4
U
L
U
L
1
1DU1  
1DU1.6  
1DU2  
Standard Pack: 12  
U
L
Weight:  
10  
4
U
L
0.3A - 32A  
U
L
1DU2.5  
1DU3  
1.68kg (3.7 lb.)  
40A - 63A  
U
L
1
U
L
1DU3.5  
1DU4  
1DU5  
0.4  
1.92kg (4.23 lb.)  
U
L
10-1  
U
L
4x10-2  
One Pole  
U
L
1DU6  
1DU8  
10-2  
U
L
4x10-3  
U
L
1DU10  
NA  
NA  
12A  
10-3  
1
2
3
4
5 6 8 10 1620  
40  
100  
12.5A  
13A  
15A  
Multiple of Rated Current  
U
L
1DU13  
1DU15  
1DU16  
1DU20  
1DU25  
1DU30  
1DU32  
1DU40  
1DU50  
1DU60  
1DU63  
U
L
91.5 mm  
(3.60 in.)  
35 mm  
U
L
(1.38 in.)  
16A  
20A  
V-EA-D Trip  
13A Through 63A Rated Current  
1.13-1.45xIN  
U
L
U
L
25A  
30A  
60  
40  
U
L
U
L
32A  
40A  
10  
70 mm  
Thermal Overload  
“Must Trip” < 1 hr = 145% RC  
U
L
17.5 mm  
(0.69 in.)  
4
(2.76 in.)  
“Must Not Trip” > 1 hr = 113% RC  
1
U
L
50A  
60A  
U
L
63A  
10  
4
For ring tongue terminal version, replace “U”  
with “R” in part number. For example 1BR20  
instead of 1BU20.  
1
0.4  
Voltage Rating  
277VAC  
0.3-25A: 1 pole - 42VDC  
30-60A: 1 pole - 24VDC  
10-1  
4x10-2  
10-2  
4x10-3  
0.3-60A (RC): 10kA with UL-listed  
RK5 back-up fuse or MCCB  
Short Circuit Withstand Rating  
(UL/CSA - Ratings)  
10-3  
1
2
3
4
5 6 8 10 1620  
40  
100  
0.3-10A (RC): 10kA; 12-60A (RC): 5kA  
no branch circuit protection required  
Group Short Circuit Withstand Rating  
(UL/CSA - Ratings)  
Multiple of Rated Current  
0.3-63A (RC): 10kA  
Interrupting Capacity (VDE - Ratings)  
40°C (104°F)  
Calibration Temperature  
Terminal Size Acceptability  
Terminal Torque  
Top: 18-3 AWG; Bottom: 18-2 AWG  
20 lb.in.  
IP20  
Terminal Protection Degree  
short circuit Withstand ratings for v-ea manual motor controller  
Backup  
Protection  
UL-Listed  
RK5-Fuse  
up to 10kA  
UL-Listed  
MCCB  
up to 10kA  
No BCP  
Required  
up to:  
Trip  
Curve  
Amp Range  
0.3 - 10A  
all  
all  
all  
all  
4xRC*  
min 15A, max 70A  
4xRC*  
min 15A, max 70A  
10kA  
5kA  
5kA  
5kA  
12 - 30/32A  
40 - 50A  
4xRC*  
max 125A  
4xRC*  
max 125A  
4xRC*  
max 200A  
4xRC*  
max 200A  
60 / 63A  
4xRC*  
max 250A  
4xRC*  
max 250A  
*up to nearest rated current  

相关型号:

1DU63L

Thermal Magnetic Circuit Breaker,
ALTECH

1DU63R

Thermal Magnetic Circuit Breaker,
ALTECH

1DU8L

Thermal Magnetic Circuit Breaker,
ALTECH

1DU8R

Thermal Magnetic Circuit Breaker,
ALTECH

1DX

2.4GHz Wi-Fi Bluetooth 4.1 EDR Module
MURATA

1E-11PT-15.5

E Rated Potential Transformer Fuses
LITTELFUSE

1E-16PT-25.5

E Rated Potential Transformer Fuses
LITTELFUSE

1E-4PT-2.4

E Rated Potential Transformer Fuses
LITTELFUSE

1E-5PT-4.8

E Rated Potential Transformer Fuses
LITTELFUSE

1E-6PT-2.75

E Rated Potential Transformer Fuses
LITTELFUSE

1E-6PT-5.5

E Rated Potential Transformer Fuses
LITTELFUSE

1E-8PT-2.75

E Rated Potential Transformer Fuses
LITTELFUSE