TR-11CY6315A [ALTECH]

UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment; UL1077认可辅助保护器/断路器的设备
TR-11CY6315A
型号: TR-11CY6315A
厂家: ALTECH CORPORATION    ALTECH CORPORATION
描述:

UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment
UL1077认可辅助保护器/断路器的设备

断路器
文件: 总3页 (文件大小:479K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
TR11 Series  
E209569  
up to 12 Amps  
UL1077 Recognized  
Supplementary Protector/  
Circuit Breaker for Equipment  
Applications:  
Protection of single phase Motors, Transformers,  
UPS, Power strips, Solenoids etc., against  
damage due to overcurrent conditions.  
Current Rating  
Rated Voltage  
0.5 -16.0A  
240V AC, 50/60Hz, 32V DC / 24V DC (VDE)  
Operating  
(As per EN 60934)  
Initial insulation resistance  
Dielectric strength  
> 100 M ohms.  
1.5 KV for One minute.  
(As per EN 60934)  
Characteristic  
6 I ~ up to 9.0A  
n
(As per EN 60934)  
4 I - up to 12.0A  
n
Overload Switching Capacity  
Maximum Breaking Capacity  
60A Max. ~ from 10.0A to 12.0A  
60A Max. - from 10.0A to 12.0A  
8x I for <6.0A  
n
60A MAX. for > 6.0A  
1 - 2 Watts  
Maximum 60°C Ambient  
1000 Cycles  
1000 Amps PC 1  
(min)  
60  
30  
20  
10  
5
Power Loss  
Operating Temperature  
Operational Life at 2xIn  
Limited short circuit current  
1
0.25” Quick connect  
Terminals  
(S)  
50  
EN 60934, CSA 22.2 No. 235, UL-1077  
Applicable Standards  
Approvals  
20  
10  
5
up to 16.0 A  
upto 12.0A  
Accessories  
Dust Cover, DC-TR11 C (see page 14)  
2
1
Time Current Characteristics:  
The standard characteristic is valid for ambient temperatures of  
+23°C. If the device is to be used in an ambient temperature other  
than +23°C, allowances must be made when selecting the current  
rating according to the following guidelines:  
0.5  
0.2  
0.1  
1.05 1.32  
Ambient temp. °C  
-20  
-5  
0
+10 +20  
+30 +40 +50 +60  
1.05 1.12 1.2 1.3  
2
3
4 5  
8 10  
Correction Factor  
0.8 0.88 0.9 0.96  
1
Multiple of Rated Current  
Example :  
Normal Continuous Current  
Ambient Temperature  
:
:
:
:
:
1.8A  
40°C  
Rated current  
Correction Factor  
1.12  
< 6 A  
> 6 A  
23°C  
Recommended Current Rating  
Select the nearest  
1.8 x 1.12 = 2.016  
Ambient  
2.0A  
Temperature  
®
Altech Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com  
16  
TR-11 Characteristics  
& Mounting Options  
Application Examples:  
Protection of single phase Motors,  
Transformers, UPS, Power strips, Solenoids  
etc., against damage due to overcurrent  
E209569  
up to 12 Amps  
conditions.  
Rated  
Current  
0.5A  
0.9A  
1.0A  
1.2A  
1.5A  
1.8A  
2.0A  
2.2A  
2.5A  
2.7A  
3A  
Type/  
Rated  
Type/  
Cat. No.  
Current  
Cat. No.  
TR-11CX630.5A  
TR-11CX630.9A  
TR-11CX631A  
TR-11CX631.2A  
TR-11CX631.5A  
TR-11CX631.8A  
TR-11CX632A  
TR-11CX632.2A  
TR-11CX632.5A  
TR-11CX632.7A  
TR-11CX633A  
TR-11CX633.3A  
TR-11CX634A  
TR-11CX635A  
TR-11CX636A  
TR-11CY636.5A  
TR-11CY637A  
TR-11CY638A  
TR-11CY639A  
TR-11CY6310A  
TR-11CY6312A  
TR-11CY6315A  
TR-11CY6316A  
3.3A  
4A  
Central  
Wing  
5A  
6A  
Mounting  
Clips*  
6.5A  
7A  
Standard Pack: 10  
Standard Pack: 10  
Weight:  
Weight:  
8A  
0.27kg (0.6 lb.)  
0.27kg (0.6 lb.)  
9A  
10A  
12A  
15A  
16A  
Rated  
Type/  
Rated  
Type/  
Current  
Cat. No.  
Current  
Cat. No.  
Snap  
Integral  
Fitting*  
Mounting*  
Standard Pack: 10  
Standard Pack: 10  
Weight:  
Weight:  
0.27kg (0.6 lb.)  
0.27kg (0.6 lb.)  
* SPECIAL ORDER ONLY. Contact Altech for more details.  
PCB Mounting and additional Shunt Terminal available, please contact Altech.  
®
Altech Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com  
17  
TR-11  
Dimensions & Mounting Options  
Central Mounting  
DIA 4  
10  
9
MAXIMUM TORQUE 0.5 Nm  
M10 X 1  
A/F 13  
PANEL CUTOUT  
19  
15  
11  
9.4  
0.8  
10.2  
Alternate 1  
Alternate 2  
Wing Clips  
DIA 4  
DIA 12  
5
.
5
1
Ø
PANEL CUTOUT  
11  
19  
15  
12.7  
15.2  
13.9+0.1  
0.8  
Snap Fitting  
DIA 4  
13  
12  
PANEL CUTOUT  
X +0.1  
14  
21.7  
11  
0.8  
15  
Integral Mounting  
DIA 4  
10  
9
19  
15  
11  
0.8  
Dust Cover  
Cover is suitable for central mounting type  
circuit breaker to provide dust & splash  
protection (IP 54).  
Type/Cat. No.: DC TR11 C  
DIA 16  
M10 X 1  
Dimensions in mm (to convert to inches multiply by 0.03937)  
®
Altech Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com  
18  

相关型号:

TR-11CY6316A

UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment
ALTECH

TR-11CY636.5A

UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment
ALTECH

TR-11CY637A

UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment
ALTECH

TR-11CY638A

UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment
ALTECH

TR-11CY639A

UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment
ALTECH

TR-11SX630.5A

UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment
ALTECH

TR-11SX630.9A

UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment
ALTECH

TR-11SX631.2A

UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment
ALTECH

TR-11SX631.5A

UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment
ALTECH

TR-11SX631.8A

UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment
ALTECH

TR-11SX631A

UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment
ALTECH

TR-11SX632.2A

UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment
ALTECH