FLEX 8000
Programmable Logic
Device Family
®
January 2003, ver. 11.1
Data Sheet
1
■
■
Low-cost, high-density, register-rich CMOS programmable logic
device (PLD) family (see Table 1)
Features...
–
–
2,500 to 16,000 usable gates
282 to 1,500 registers
System-level features
–
In-circuit reconfigurability (ICR) via external configuration
devices or intelligent controller
–
Fully compliant with the peripheral component interconnect
Special Interest Group (PCI SIG) PCI Local Bus Specification,
Revision 2.2 for 5.0-V operation
–
–
–
Built-in Joint Test Action Group (JTAG) boundary-scan test (BST)
circuitry compliant with IEEE Std. 1149.1-1990 on selected devices
MultiVoltTM I/O interface enabling device core to run at 5.0 V,
while I/O pins are compatible with 5.0-V and 3.3-V logic levels
Low power consumption (typical specification is 0.5 mA or less in
standby mode)
3
■
Flexible interconnect
–
FastTrack® Interconnect continuous routing structure for fast,
predictable interconnect delays
–
Dedicated carry chain that implements arithmetic functions such
as fast adders, counters, and comparators (automatically used by
software tools and megafunctions)
–
–
Dedicated cascade chain that implements high-speed, high-fan-in
logic functions (automatically used by software tools and
megafunctions)
Tri-state emulation that implements internal tri-state nets
■
■
Powerful I/O pins
Programmable output slew-rate control reduces switching noise
Table 1. FLEX 8000 Device Features
Feature
EPF8282A
EPF8282AV
EPF8452A EPF8636A EPF8820A EPF81188A EPF81500A
Usable gates
2,500
282
26
4,000
452
42
6,000
636
63
8,000
820
84
12,000
1,188
126
16,000
1,500
162
Flipflops
Logic array blocks (LABs)
Logic elements (LEs)
Maximum user I/O pins
208
78
336
120
504
136
672
152
1,008
184
1,296
208
Altera Corporation
1
DS-F8000-11.1
FLEX 8000 Programmable Logic Device Family Data Sheet
JTAG BST circuitry
Yes
No
Yes
Yes
No
Yes
■
■
■
■
Peripheral register for fast setup and clock-to-output delay
Fabricated on an advanced SRAM process
Available in a variety of packages with 84 to 304 pins (see Table 2)
Software design support and automatic place-and-route provided by
the Altera® MAX+PLUS® II development system for Windows-based
PCs, as well as Sun SPARCstation, HP 9000 Series 700/800, and IBM
RISC System/6000 workstations
...and More
Features
■
Additional design entry and simulation support provided by EDIF
2 0 0 and 3 0 0 netlist files, library of parameterized modules (LPM),
Verilog HDL, VHDL, and other interfaces to popular EDA tools from
manufacturers such as Cadence, Exemplar Logic, Mentor Graphics,
OrCAD, Synopsys, Synplicity, and Veribest
Table 2. FLEX 8000 Package Options & I/O Pin Count
Note (1)
Device
84-
Pin
100- 144-
Pin Pin
160- 160- 192- 208- 225- 232- 240- 280- 304-
Pin Pin Pin Pin Pin Pin Pin Pin Pin
PLCC TQFP TQFP PQFP PGA PGA PQFP BGA PGA PQFP PGA RQFP
EPF8282A
EPF8282AV
EPF8452A
EPF8636A
EPF8820A
EPF81188A
EPF81500A
68
78
78
68
68
68
120
118
120
120
136
152
136
152
148
112
152
184
184
181
208
208
Note:
(1) FLEX 8000 device package types include plastic J-lead chip carrier (PLCC), thin quad flat pack (TQFP), plastic quad
flat pack (PQFP), power quad flat pack (RQFP), ball-grid array (BGA), and pin-grid array (PGA) packages.
Altera’s Flexible Logic Element MatriX (FLEX®) family combines the
benefits of both erasable programmable logic devices (EPLDs) and field-
programmable gate arrays (FPGAs). The FLEX 8000 device family is ideal
for a variety of applications because it combines the fine-grained
architecture and high register count characteristics of FPGAs with the
high speed and predictable interconnect delays of EPLDs. Logic is
implemented in LEs that include compact 4-input look-up tables (LUTs)
and programmable registers. High performance is provided by a fast,
continuous network of routing resources.
General
Description
2
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
FLEX 8000 devices provide a large number of storage elements for
applications such as digital signal processing (DSP), wide-data-path
manipulation, and data transformation. These devices are an excellent
choice for bus interfaces, TTL integration, coprocessor functions, and
high-speed controllers. The high-pin-count packages can integrate
multiple 32-bit buses into a single device. Table 3 shows FLEX 8000
performance and LE requirements for typical applications.
Table 3. FLEX 8000 Performance
Application
LEs Used
Speed Grade
A-3
Units
A-2
A-4
16
16
24
4
16-bit loadable counter
16-bit up/down counter
24-bit accumulator
125
125
87
95
95
83
83
MHz
MHz
MHz
ns
67
58
16-bit address decode
16-to-1 multiplexer
4.2
6.6
4.9
7.9
6.3
9.5
10
ns
3
All FLEX 8000 device packages provide four dedicated inputs for
synchronous control signals with large fan-outs. Each I/O pin has an
associated register on the periphery of the device. As outputs, these
registers provide fast clock-to-output times; as inputs, they offer quick
setup times.
The logic and interconnections in the FLEX 8000 architecture are
configured with CMOS SRAM elements. FLEX 8000 devices are
configured at system power-up with data stored in an industry-standard
parallel EPROM or an Altera serial configuration devices, or with data
provided by a system controller. Altera offers the EPC1, EPC1213,
EPC1064, and EPC1441 configuration devices, which configure
FLEX 8000 devices via a serial data stream. Configuration data can also be
stored in an industry-standard 32 K × 8 bit or larger configuration device,
or downloaded from system RAM. After a FLEX 8000 device has been
configured, it can be reconfigured in-circuit by resetting the device and
loading new data. Because reconfiguration requires less than 100 ms, real-
time changes can be made during system operation. For information on
how to configure FLEX 8000 devices, go to the following documents:
■
■
■
■
■
Configuration Devices for APEX & FLEX Devices Data Sheet
BitBlaster Serial Download Cable Data Sheet
ByteBlasterMV Parallel Port Download Cable Data Sheet
Application Note 33 (Configuring FLEX 8000 Devices)
Application Note 38 (Configuring Multiple FLEX 8000 Devices)
Altera Corporation
3
FLEX 8000 Programmable Logic Device Family Data Sheet
FLEX 8000 devices contain an optimized microprocessor interface that
permits the microprocessor to configure FLEX 8000 devices serially, in
parallel, synchronously, or asynchronously. The interface also enables the
microprocessor to treat a FLEX 8000 device as memory and configure the
device by writing to a virtual memory location, making it very easy for the
designer to create configuration software.
The FLEX 8000 family is supported by Altera’s MAX+PLUS II
development system, a single, integrated package that offers schematic,
text—including the Altera Hardware Description Language (AHDL),
VHDL, and Verilog HDL—and waveform design entry, compilation and
logic synthesis, simulation and timing analysis, and device programming.
The MAX+PLUS II software provides EDIF 2 0 0 and 3 0 0, library of
parameterized modules (LPM), VHDL, Verilog HDL, and other interfaces
for additional design entry and simulation support from other industry-
standard PC- and UNIX workstation-based EDA tools. The
MAX+PLUS II software runs on Windows-based PCs and Sun
SPARCstation, HP 9000 Series 700/800, and IBM RISC System/6000
workstations.
The MAX+PLUS II software interfaces easily with common gate array
EDA tools for synthesis and simulation. For example, the MAX+PLUS II
software can generate Verilog HDL files for simulation with tools such as
Cadence Verilog-XL. Additionally, the MAX+PLUS II software contains
EDA libraries that use device-specific features such as carry chains, which
are used for fast counter and arithmetic functions. For instance, the
Synopsys Design Compiler library supplied with the MAX+PLUS II
development system includes DesignWare functions that are optimized
for the FLEX 8000 architecture.
For more information on the MAX+PLUS II software, go to the
MAX+PLUS II Programmable Logic Development System & Software Data
Sheet.
f
The FLEX 8000 architecture incorporates a large matrix of compact
building blocks called logic elements (LEs). Each LE contains a 4-input
LUT that provides combinatorial logic capability and a programmable
register that offers sequential logic capability. The fine-grained structure
of the LE provides highly efficient logic implementation.
Functional
Description
Eight LEs are grouped together to form a logic array block (LAB). Each
FLEX 8000 LAB is an independent structure with common inputs,
interconnections, and control signals. The LAB architecture provides a
coarse-grained structure for high device performance and easy routing.
4
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Figure 1 shows a block diagram of the FLEX 8000 architecture. Each group
of eight LEs is combined into an LAB; LABs are arranged into rows and
columns. The I/O pins are supported by I/O elements (IOEs) located at
the ends of rows and columns. Each IOE contains a bidirectional I/O
buffer and a flipflop that can be used as either an input or output register.
Figure 1. FLEX 8000 Device Block Diagram
IOE
IOE
IOE
IOE
I/O Element
(IOE)
IOE
IOE
IOE
IOE
FastTrack
Interconnect
Logic Array
Block (LAB)
3
IOE
IOE
IOE
IOE
Logic
Element (LE)
IOE
IOE
IOE
IOE
Signal interconnections within FLEX 8000 devices and between device
pins are provided by the FastTrack Interconnect, a series of fast,
continuous channels that run the entire length and width of the device.
IOEs are located at the end of each row (horizontal) and column (vertical)
FastTrack Interconnect path.
Altera Corporation
5
FLEX 8000 Programmable Logic Device Family Data Sheet
Logic Array Block
A logic array block (LAB) consists of eight LEs, their associated carry and
cascade chains, LAB control signals, and the LAB local interconnect. The
LAB provides the coarse-grained structure of the FLEX 8000 architecture.
This structure enables FLEX 8000 devices to provide efficient routing,
high device utilization, and high performance. Figure 2 shows a block
diagram of the FLEX 8000 LAB.
Figure 2. FLEX 8000 Logic Array Block
Dedicated
Inputs
Row Interconnect
24
4
8
LAB Local
Interconnect
(32 channels)
4
See Figure 8
for details.
Carry-In and
Cascade-In
from LAB
on Left
8
16
LAB Control
Signals
4
2
Column-to-Row
Interconnect
LE1
4
4
4
4
4
4
4
4
Column
Interconnect
LE2
LE3
LE4
LE5
LE6
LE7
LE8
8
2
Carry-Out and
Cascade-Out
to LAB on Right
6
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Each LAB provides four control signals that can be used in all eight LEs.
Two of these signals can be used as clocks, and the other two for
clear/preset control. The LAB control signals can be driven directly from
a dedicated input pin, an I/O pin, or any internal signal via the LAB local
interconnect. The dedicated inputs are typically used for global clock,
clear, or preset signals because they provide synchronous control with
very low skew across the device. FLEX 8000 devices support up to four
individual global clock, clear, or preset control signals. If logic is required
on a control signal, it can be generated in one or more LEs in any LAB and
driven into the local interconnect of the target LAB.
Logic Element
The logic element (LE) is the smallest unit of logic in the FLEX 8000
architecture, with a compact size that provides efficient logic utilization.
Each LE contains a 4-input LUT, a programmable flipflop, a carry chain,
and cascade chain. Figure 3 shows a block diagram of an LE.
Figure 3. FLEX 8000 LE
3
Carry-In
Cascade-In
DFF
PRN
DATA1
DATA2
DATA3
DATA4
Look-Up
Table
(LUT)
LE-Out
Carry
Chain
Cascade
Chain
D
Q
CLRN
Clear/
Preset
Logic
LABCTRL1
LABCTRL2
Clock
Select
LABCTRL3
LABCTRL4
Carry-Out
Cascade-Out
The LUT is a function generator that can quickly compute any function of
four variables. The programmable flipflop in the LE can be configured for
D, T, JK, or SR operation. The clock, clear, and preset control signals on the
flipflop can be driven by dedicated input pins, general-purpose I/O pins,
or any internal logic. For purely combinatorial functions, the flipflop is
bypassed and the output of the LUT goes directly to the output of the LE.
Altera Corporation
7
FLEX 8000 Programmable Logic Device Family Data Sheet
The FLEX 8000 architecture provides two dedicated high-speed data
paths—carry chains and cascade chains—that connect adjacent LEs
without using local interconnect paths. The carry chain supports high-
speed counters and adders; the cascade chain implements wide-input
functions with minimum delay. Carry and cascade chains connect all LEs
in an LAB and all LABs in the same row. Heavy use of carry and cascade
chains can reduce routing flexibility. Therefore, the use of carry and
cascade chains should be limited to speed-critical portions of a design.
Carry Chain
The carry chain provides a very fast (less than 1 ns) carry-forward
function between LEs. The carry-in signal from a lower-order bit moves
forward into the higher-order bit via the carry chain, and feeds into both
the LUT and the next portion of the carry chain. This feature allows the
FLEX 8000 architecture to implement high-speed counters and adders of
arbitrary width. The MAX+PLUS II Compiler can create carry chains
automatically during design processing; designers can also insert carry
chain logic manually during design entry.
Figure 4 shows how an n-bit full adder can be implemented in n + 1 LEs
with the carry chain. One portion of the LUT generates the sum of two bits
using the input signals and the carry-in signal; the sum is routed to the
output of the LE. The register is typically bypassed for simple adders, but
can be used for an accumulator function. Another portion of the LUT and
the carry chain logic generate the carry-out signal, which is routed directly
to the carry-in signal of the next-higher-order bit. The final carry-out
signal is routed to another LE, where it can be used as a general-purpose
signal. In addition to mathematical functions, carry chain logic supports
very fast counters and comparators.
8
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Figure 4. FLEX 8000 Carry Chain Operation
Carry-In
LU
s1
Register
a1
b1
Carry
LE1
a2
b2
s2
LUT
Register
Carry Chain
LE2
3
LUT
sn
an
bn
Register
Carry Chain
LEn
LUT
Carry-Out
Register
Carry Chain
LEn + 1
Cascade Chain
With the cascade chain, the FLEX 8000 architecture can implement
functions that have a very wide fan-in. Adjacent LUTs can be used to
compute portions of the function in parallel; the cascade chain serially
connects the intermediate values. The cascade chain can use a logical AND
or logical OR(via De Morgan’s inversion) to connect the outputs of
adjacent LEs. Each additional LE provides four more inputs to the
effective width of a function, with a delay as low as 0.6 ns per LE.
Altera Corporation
9
FLEX 8000 Programmable Logic Device Family Data Sheet
The MAX+PLUS II Compiler can create cascade chains automatically
during design processing; designers can also insert cascade chain logic
manually during design entry. Cascade chains longer than eight LEs are
automatically implemented by linking LABs together. The last LE of an
LAB cascades to the first LE of the next LAB.
Figure 5 shows how the cascade function can connect adjacent LEs to
form functions with a wide fan-in. These examples show functions of 4n
variables implemented with n LEs. For a device with an A-2 speed grade,
the LE delay is 2.4 ns; the cascade chain delay is 0.6 ns. With the cascade
chain, 4.2 ns is needed to decode a 16-bit address.
Figure 5. FLEX 8000 Cascade Chain Operation
AND Cascade Chain
OR Cascade Chain
LE1
LE2
LE1
LE2
d[3..0]
d[3..0]
LUT
LUT
LUT
LUT
d[7..4]
d[7..4]
LEn
LEn
d[(4n-1)..4(n-1)]
d[(4n-1)..4(n-1)]
LUT
LUT
LE Operating Modes
The FLEX 8000 LE can operate in one of four modes, each of which uses
LE resources differently. See Figure 6. In each mode, seven of the ten
available inputs to the LE—the four data inputs from the LAB local
interconnect, the feedback from the programmable register, and the
carry-in and cascade-in from the previous LE—are directed to different
destinations to implement the desired logic function. The three remaining
inputs to the LE provide clock, clear, and preset control for the register.
The MAX+PLUS II software automatically chooses the appropriate mode
for each application. Design performance can also be enhanced by
designing for the operating mode that supports the desired application.
10
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Figure 6. FLEX 8000 LE Operating Modes
Normal Mode
Cascade-In
LE-Out
Carry-In
PRN
data1
data2
4-Input
D
Q
LUT
data3
CLRN
Cascade-Out
data4
Arithmetic Mode
Carry-In
Cascade-In
LE-Out
PRN
D
Q
data1
3-Input
LUT
data2
CLRN
Cascade-Out
3-Input
LUT
3
Carry-Out
Up/Down Counter Mode
Cascade-In
Carry-In
(ena)
(nclr)
data1
data2
PRN
3-Input
LUT
1
0
LE-Out
D
Q
(data)
data3
CLRN
3-Input
LUT
data4 (nload)
Carry-Out
Cascade-Out
Clearable Counter Mode
Carry-In
(ena)
(nclr)
data1
data2
PRN
3-Input
LUT
1
LE-Out
D
Q
0
data3 (data)
CLRN
3-Input
LUT
(nload)
data4
Carry-Out
Cascade-Out
Altera Corporation
11
FLEX 8000 Programmable Logic Device Family Data Sheet
Normal Mode
The normal mode is suitable for general logic applications and wide
decoding functions that can take advantage of a cascade chain. In normal
mode, four data inputs from the LAB local interconnect and the carry-in
signal are the inputs to a 4-input LUT. Using a configurable SRAM bit, the
MAX+PLUS II Compiler automatically selects the carry-in or the DATA3
signal as an input. The LUT output can be combined with the cascade-in
signal to form a cascade chain through the cascade-out signal. TheLE-Out
signal—the data output of the LE—is either the combinatorial output of
the LUT and cascade chain, or the data output (Q)of the programmable
register.
Arithmetic Mode
The arithmetic mode offers two 3-input LUTs that are ideal for
implementing adders, accumulators, and comparators. One LUT
provides a 3-bit function; the other generates a carry bit. As shown in
Figure 6, the first LUT uses the carry-in signal and two data inputs from
the LAB local interconnect to generate a combinatorial or registered
output. For example, in an adder, this output is the sum of three bits: a, b,
and the carry-in. The second LUT uses the same three signals to generate
a carry-out signal, thereby creating a carry chain. The arithmetic mode
also supports a cascade chain.
Up/Down Counter Mode
The up/down counter mode offers counter enable, synchronous
up/down control, and data loading options. These control signals are
generated by the data inputs from the LAB local interconnect, the carry-in
signal, and output feedback from the programmable register. Two 3-input
LUTs are used: one generates the counter data, and the other generates the
fast carry bit. A 2-to-1 multiplexer provides synchronous loading. Data
can also be loaded asynchronously with the clear and preset register
control signals, without using the LUT resources.
Clearable Counter Mode
The clearable counter mode is similar to the up/down counter mode, but
supports a synchronous clear instead of the up/down control; the clear
function is substituted for the cascade-in signal in the up/down counter
mode. Two 3-input LUTs are used: one generates the counter data, and
the other generates the fast carry bit. Synchronous loading is provided by
a 2-to-1 multiplexer, and the output of this multiplexer is ANDed with a
synchronous clear.
12
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Internal Tri-State Emulation
Internal tri-state emulation provides internal tri-stating without the
limitations of a physical tri-state bus. In a physical tri-state bus, the
tri-state buffers’ output enable signals select the signal that drives the bus.
However, if multiple output enable signals are active, contending signals
can be driven onto the bus. Conversely, if no output enable signals are
active, the bus will float. Internal tri-state emulation resolves contending
tri-state buffers to a low value and floating buses to a high value, thereby
eliminating these problems. The MAX+PLUS II software automatically
implements tri-state bus functionality with a multiplexer.
Clear & Preset Logic Control
Logic for the programmable register’s clear and preset functions is
controlled by the DATA3, LABCTRL1, and LABCTRL2inputs to the LE. The
clear and preset control structure of the LE is used to asynchronously load
signals into a register. The register can be set up so that LABCTRL1
implements an asynchronous load. The data to be loaded is driven to
DATA3; when LABCTRL1is asserted, DATA3is loaded into the register.
3
During compilation, the MAX+PLUS II Compiler automatically selects
the best control signal implementation. Because the clear and preset
functions are active-low, the Compiler automatically assigns a logic high
to an unused clear or preset.
The clear and preset logic is implemented in one of the following six
asynchronous modes, which are chosen during design entry. LPM
functions that use registers will automatically use the correct
asynchronous mode. See Figure 7.
■
■
■
■
■
■
Clear only
Preset only
Clear and preset
Load with clear
Load with preset
Load without clear or preset
Altera Corporation
13
FLEX 8000 Programmable Logic Device Family Data Sheet
Figure 7. FLEX 8000 LE Asynchronous Clear & Preset Modes
Asynchronous Clear
Asynchronous Clear & Preset
Asynchronous Preset
VCC
PRN
LABCTRL1 or
LABCTRL2
LABCTRL1
PRN
PRN
Q
D
Q
D
Q
D
CLRN
CLRN
CLRN
LABCTRL1 or
LABCTRL2
LABCTRL2
Asynchronous Load with Clear
NOT
NOT
LABCTRL1
(Asynchronous
Load)
PRN
DATA3
(Data)
Q
D
CLRN
LABCTRL2
(Clear)
Asynchronous Load with Preset
NOT
LABCTRL1
(Asynchronous
Load)
LABCTRL2
(Preset)
PRN
Q
D
DATA3
(Data)
CLRN
NOT
Asynchronous Load without Clear or Preset
NOT
LABCTRL1
(Asynchronous
Load)
PRN
DATA3
(Data)
Q
D
CLRN
NOT
14
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Asynchronous Clear
A register is cleared by one of the two LABCTRLsignals. When the CLRn
port receives a low signal, the register is set to zero.
Asynchronous Preset
An asynchronous preset is implemented as either an asynchronous load
or an asynchronous clear. If DATA3is tied to VCC, asserting LABCTRLl
asynchronously loads a 1into the register. Alternatively, the
MAX+PLUS II software can provide preset control by using the clear and
inverting the input and output of the register. Inversion control is
available for the inputs to both LEs and IOEs. Therefore, if a register is
preset by only one of the two LABCTRLsignals, the DATA3input is not
needed and can be used for one of the LE operating modes.
Asynchronous Clear & Preset
When implementing asynchronous clear and preset, LABCTRL1controls
the preset and LABCTRL2controls the clear. The DATA3input istied to VCC;
therefore, asserting LABCTRL1asynchronously loads a 1into the register,
effectively presetting the register. Asserting LABCTRL2clears the register.
3
Asynchronous Load with Clear
When implementing an asynchronous load with the clear, LABCTRL1
implements the asynchronous load of DATA3by controlling the register
preset and clear. LABCTRL2implements the clear by controlling the
register clear.
Asynchronous Load with Preset
When implementing an asynchronous load in conjunction with a preset,
the MAX+PLUS II software provides preset control by using the clear and
inverting the input and output of the register. Asserting LABCTRL2clears
the register, while asserting LABCTRL1loads the register. The
MAX+PLUS II software inverts the signal that drives the DATA3signal to
account for the inversion of the register’s output.
Asynchronous Load without Clear or Preset
When implementing an asynchronous load without the clear or preset,
LABCTRL1implements the asynchronous load of DATA3by controlling the
register preset and clear.
Altera Corporation
15
FLEX 8000 Programmable Logic Device Family Data Sheet
FastTrack Interconnect
In the FLEX 8000 architecture, connections between LEs and device I/O
pins are provided by the FastTrack Interconnect, a series of continuous
horizontal (row) and vertical (column) routing channels that traverse the
entire FLEX 8000 device. This device-wide routing structure provides
predictable performance even in complex designs. In contrast, the
segmented routing structure in FPGAs requires switch matrices to
connect a variable number of routing paths, which increases the delays
between logic resources and reduces performance.
The LABs within FLEX 8000 devices are arranged into a matrix of
columns and rows. Each row of LABs has a dedicated row interconnect
that routes signals both into and out of the LABs in the row. The row
interconnect can then drive I/O pins or feed other LABs in the device.
Figure 8 shows how an LE drives the row and column interconnect.
Figure 8. FLEX 8000 LAB Connections to Row & Column Interconnect
16 Column
Channels
Row Channels
(1)
Each LE drives one
row channel.
LE1
LE2
to Local
Feedback Feedback
to Local
Each LE drives up to
two column channels.
Note:
(1) See Table 4 for the number of row channels.
16
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Each LE in an LAB can drive up to two separate column interconnect
channels. Therefore, all 16 available column channels can be driven by the
LAB. The column channels run vertically across the entire device, and
share access to LABs in the same column but in different rows. The
MAX+PLUS II Compiler chooses which LEs must be connected to a
column channel. A row interconnect channel can be fed by the output of
the LE or by two column channels. These three signals feed a multiplexer
that connects to a specific row channel. Each LE is connected to one 3-to-1
multiplexer. In an LAB, the multiplexers provide all 16 column channels
with access to 8 row channels.
Each column of LABs has a dedicated column interconnect that routes
signals out of the LABs into the column. The column interconnect can then
drive I/O pins or feed into the row interconnect to route the signals to
other LABs in the device. A signal from the column interconnect, which
can be either the output of an LE or an input from an I/O pin, must
transfer to the row interconnect before it can enter an LAB. Table 4
summarizes the FastTrack Interconnect resources available in each
FLEX 8000 device.
3
Table 4. FLEX 8000 FastTrack Interconnect Resources
Device
Rows Channels per Row Columns Channels per Column
EPF8282A
2
168
13
16
EPF8282AV
EPF8452A
EPF8636A
EPF8820A
EPF81188A
EPF81500A
2
3
4
6
6
168
168
168
168
216
21
21
21
21
27
16
16
16
16
16
Figure 9 shows the interconnection of four adjacent LABs, with row,
column, and local interconnects, as well as the associated cascade and
carry chains.
Altera Corporation
17
FLEX 8000 Programmable Logic Device Family Data Sheet
Figure 9. FLEX 8000 Device Interconnect Resources
Each LAB is named according to its physical row (A, B, C, etc.) and column (1, 2, 3, etc.) position within the device.
See Figure 12
for details.
IOE
IOE
IOE
IOE
Column
Interconnect
See Figure 11
for details.
Row
Interconnect
1
IOE
IOE
IOE
1
8
8 IOE
LAB
A1
LAB
A2
1
IOE
IOE
IOE
1
8
8 IOE
LAB
B1
LAB
B2
LAB Local
Interconnect
Cascade &
Carry Chain
IOE
IOE
IOE
IOE
I/O Element
An IOE contains a bidirectional I/O buffer and a register that can be used
either as an input register for external data that requires a fast setup time,
or as an output register for data that requires fast clock-to-output
performance. IOEs can be used as input, output, or bidirectional pins. The
MAX+PLUS II Compiler uses the programmable inversion option to
automatically invert signals from the row and column interconnect where
appropriate. Figure 10 shows the IOE block diagram.
18
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Figure 10. FLEX 8000 IOE
Numbers in parentheses are for EPF81500A devices only.
I/O Controls
6
To Row or Column
Interconnect
Programmable
Inversion
(6)
VCC
From Row or Column
Interconnect
D
Q
Slew-Rate
Control
CLRN
VCC
3
Row-to-IOE Connections
Figure 11 illustrates the connection between row interconnect channels
and IOEs. An input signal from an IOE can drive two separate row
channels. When an IOE is used as an output, the signal is driven by an
n-to-1 multiplexer that selects the row channels. The size of the
multiplexer varies with the number of columns in a device. EPF81500A
devices use a 27-to-1 multiplexer; EPF81188A, EPF8820A, EPF8636A, and
EPF8452A devices use a 21-to-1 multiplexer; and EPF8282A and
EPF8282AV devices use a 13-to-1 multiplexer. Eight IOEs are connected to
each side of the row channels.
Altera Corporation
19
FLEX 8000 Programmable Logic Device Family Data Sheet
Figure 11. FLEX 8000 Row-to-IOE Connections
Numbers in parentheses are for EPF81500A devices. See Note (1).
2
2
2
2
IOE 1
IOE 2
IOE 3
IOE 4
IOE 5
IOE 6
IOE 7
IOE 8
n
Each IOE can drive
up to two row
channels.
n
n
n
n
n
n
n
2
2
2
2
Row Interconnect
168
(216)
168
(216)
2
2
2
2
Each IOE is
driven by an
n-to-1
multiplexer.
2
2
2
2
Note:
(1) n = 13 for EPF8282A and EPF8282AV devices.
n = 21 for EPF8452A, EPF8636A, EPF8820A, and EPF81188A devices.
n = 27 for EPF81500A devices.
Column-to-IOE Connections
Two IOEs are located at the top and bottom of the column channels (see
Figure 12). When an IOE is used as an input, it can drive up to two
separate column channels. The output signal to an IOE can choose from 8
of the 16 column channels through an 8-to-1 multiplexer.
20
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Figure 12. FLEX 8000 Column-to-IOE Connections
Each IOE is
driven by an
8-to-1
Each IOE can drive
up to two column
signals.
IOE
IOE
multiplexer.
8
8
16
Column Interconnect
In addition to general-purpose I/O pins, FLEX 8000 devices have four
dedicated input pins. These dedicated inputs provide low-skew, device-
wide signal distribution, and are typically used for global clock, clear, and
preset control signals. The signals from the dedicated inputs are available
as control signals for all LABs and I/O elements in the device. The
dedicated inputs can also be used as general-purpose data inputs because
they can feed the local interconnect of each LAB in the device.
3
Signals enter the FLEX 8000 device either from the I/O pins that provide
general-purpose input capability or from the four dedicated inputs. The
IOEs are located at the ends of the row and column interconnect channels.
I/O pins can be used as input, output, or bidirectional pins. Each I/O pin
has a register that can be used either as an input register for external data
that requires fast setup times, or as an output register for data that
requires fast clock-to-output performance. The MAX+PLUS II Compiler
uses the programmable inversion option to invert signals automatically
from the row and column interconnect when appropriate.
The clock, clear, and output enable controls for the IOEs are provided by
a network of I/O control signals. These signals can be supplied by either
the dedicated input pins or by internal logic. The IOE control-signal paths
are designed to minimize the skew across the device. All control-signal
sources are buffered onto high-speed drivers that drive the signals around
the periphery of the device. This “peripheral bus” can be configured to
provide up to four output enable signals (10 in EPF81500A devices), and
up to two clock or clear signals. Figure 13 on page 22 shows how two
output enable signals are shared with one clock and one clear signal.
Altera Corporation
21
FLEX 8000 Programmable Logic Device Family Data Sheet
The signals for the peripheral bus can be generated by any of the four
dedicated inputs or signals on the row interconnect channels, as shown in
Figure 13. The number of row channels in a row that can drive the
peripheral bus correlates to the number of columns in the FLEX 8000
device. EPF8282A and EPF8282AV devices use 13 channels; EPF8452A,
EPF8636A, EPF8820A, and EPF81188A devices use 21 channels; and
EPF81500A devices use 27 channels. The first LE in each LAB is the source
of the row channel signal. The six peripheral control signals (12 in
EPF81500A devices) can be accessed by each IOE.
Figure 13. FLEX 8000 Peripheral Bus
Numbers in parentheses are for EPF81500A devices.
Peripheral Control
Signals
Programmable
Inversion
4
Dedicated
Inputs
1
2
Row Channels
(1)
n
Note:
(1) n = 13 for EPF8282A and EPF8282AV devices.
n = 21 for EPF8452A, EPF8636A, EPF8820A, and EPF81188A devices.
n = 27 for EPF81500A devices.
22
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 5 lists the source of the peripheral control signal for each FLEX 8000
device by row.
Table 5. Row Sources of FLEX 8000 Peripheral Control Signals
Peripheral
Control Signal EPF8282AV
EPF8282A
EPF8452A
EPF8636A
EPF8820A
EPF81188A
EPF81500A
CLK0
CLK1/OE1
CLR0
CLR1/OE0
OE2
Row A
Row A
Row A
Row A
Row E
Row E
Row B
Row F
Row C
Row A
Row A
Row B
Row C
Row D
Row D
Row E
Row F
Row B
Row B
Row C
Row C
Row B
Row A
Row A
Row B
Row B
Row F
Row B
Row B
Row C
Row D
Row C
Row A
Row A
Row A
Row A
Row D
OE3
Row B
Row B
Row B
Row B
Row A
OE4
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
OE5
OE6
3
OE7
OE8
OE9
This section discusses slew-rate control and MultiVolt I/O interface
operation for FLEX 8000 devices.
Output
Configuration
Slew-Rate Control
The output buffer in each IOE has an adjustable output slew rate that can
be configured for low-noise or high-speed performance. A slow slew rate
reduces system noise by slowing signal transitions, adding a maximum
delay of 3.5 ns. The slow slew-rate setting affects only the falling edge of
a signal. The fast slew rate should be used for speed-critical outputs in
systems that are adequately protected against noise. Designers can specify
the slew rate on a pin-by-pin basis during design entry or assign a default
slew rate to all pins on a global basis.
For more information on high-speed system design, go to Application
Note 75 (High-Speed Board Designs).
f
Altera Corporation
23
FLEX 8000 Programmable Logic Device Family Data Sheet
MultiVolt I/O Interface
The FLEX 8000 device architecture supports the MultiVolt I/O interface
feature, which allows EPF81500A, EPF81188A, EPF8820A, and EPF8636A
devices to interface with systems with differing supply voltages. These
devices in all packages—except for EPF8636A devices in 84-pin PLCC
packages—can be set for 3.3-V or 5.0-V I/O pin operation. These devices
have one set of VCC pins for internal operation and input buffers
(VCCINT), and another set for I/O output drivers (VCCIO).
The VCCINTpins must always be connected to a 5.0-V power supply. With
a 5.0-V VCCINT level, input voltages are at TTL levels and are therefore
compatible with 3.3-V and 5.0-V inputs.
The VCCIOpins can be connected to either a 3.3-V or 5.0-V power supply,
depending on the output requirements. When the VCCIOpins are
connected to a 5.0-V power supply, the output levels are compatible with
5.0-V systems. When the VCCIOpins are connected to a 3.3-V power
supply, the output high is at 3.3 V and is therefore compatible with 3.3-V
or 5.0-V systems. Devices operating with VCCIO levels lower than 4.75 V
incur a nominally greater timing delay of tOD2 instead of tOD1. See Table 8
on page 26.
The EPF8282A, EPF8282AV, EPF8636A, EPF8820A, and EPF81500A
devices provide JTAG BST circuitry. FLEX 8000 devices with JTAG
circuitry support the JTAG instructions shown in Table 6.
IEEE Std.
1149.1 (JTAG)
Boundary-Scan
Support
Table 6. EPF8282A, EPF8282AV, EPF8636A, EPF8820A & EPF81500A JTAG Instructions
JTAG Instruction Description
SAMPLE/PRELOAD Allows a snapshot of the signals at the device pins to be captured and examined during
normal device operation, and permits an initial data pattern to be output at the device pins.
EXTEST
Allows the external circuitry and board-level interconnections to be tested by forcing a test
pattern at the output pins and capturing test results at the input pins.
BYPASS
Places the 1-bit bypass register between the TDIand TDOpins, which allows the BST
data to pass synchronously through the selected device to adjacent devices during
normal device operation.
24
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
The instruction register length for FLEX 8000 devices is three bits. Table 7
shows the boundary-scan register length for FLEX 8000 devices.
Table 7. FLEX 8000 Boundary-Scan Register Length
Device
Boundary-Scan Register Length
EPF8282A, EPF8282AV
EPF8636A
273
417
465
645
EPF8820A
EPF81500A
FLEX 8000 devices that support JTAG include weak pull-ups on the JTAG
pins. Figure 14 shows the timing requirements for the JTAG signals.
Figure 14. EPF8282A, EPF8282AV, EPF8636A, EPF8820A & EPF81500A
JTAG Waveforms
TMS
3
TDI
tJCP
tJCH
tJCL
tJPH
tJPSU
TCK
TDO
t
tJPXZ
tJPCO
JPZX
tJSSU
tJSH
Signal
to Be
Captured
tJSCO
tJSXZ
tJSZX
Signal
to Be
Driven
Table 8 shows the timing parameters and values for EPF8282A,
EPF8282AV, EPF8636A, EPF8820A, and EPF81500A devices.
Altera Corporation
25
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 8. JTAG Timing Parameters & Values
Symbol
Parameter
EPF8282A
EPF8282AV
EPF8636A
EPF8820A
EPF81500A
Unit
Min Max
tJCP
TCKclock period
TCKclock high time
TCKclock low time
100
50
50
20
45
25
25
25
20
45
35
35
35
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
tJCH
tJCL
tJPSU
tJPH
JTAG port setup time
JTAG port hold time
tJPCO
tJPZX
tJPXZ
tJSSU
tJSH
JTAG port clock to output
JTAG port high-impedance to valid output
JTAG port valid output to high-impedance
Capture register setup time
Capture register hold time
tJSCO
tJSZX
tJSXZ
Update register clock to output
Update register high-impedance to valid output
Update register valid output to high-impedance
For detailed information on JTAG operation in FLEX 8000 devices, refer to
Application Note 39 (IEEE 1149.1 (JTAG) Boundary-Scan Testing in Altera
Devices).
f
Each FLEX 8000 device is functionally tested and specified by Altera.
Complete testing of each configurable SRAM bit and all logic
functionality ensures 100% configuration yield. AC test measurements for
FLEX 8000 devices are made under conditions equivalent to those shown
in Figure 15. Designers can use multiple test patterns to configure devices
during all stages of the production flow.
Generic Testing
26
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Figure 15. FLEX 8000 AC Test Conditions
Power supply transients can affect AC
measurements. Simultaneous transitions
of multiple outputs should be avoided for
accurate measurement. Threshold tests
must not be performed under AC
VCC
464 Ω
(703 Ω)
conditions. Large-amplitude, fast-ground-
current transients normally occur as the
device outputs discharge the load
capacitances. When these transients flow
through the parasitic inductance between
the device ground pin and the test system
ground, significant reductions in
Device
Output
To Test
System
250 Ω
(8.06 KΩ)
C1 (includes
JIG capacitance)
observable noise immunity can result.
Numbers in parentheses are for 3.3-V
devices or outputs. Numbers without
parentheses are for 5.0-V devices or
outputs.
Device input
rise and fall
times < 3 ns
Tables 9 through 12 provide information on absolute maximum ratings,
recommended operating conditions, operating conditions, and
capacitance for 5.0-V FLEX 8000 devices.
Operating
Conditions
3
Table 9. FLEX 8000 5.0-V Device Absolute Maximum Ratings
Note (1)
Symbol
Parameter
Conditions
Min
Max
Unit
VCC
VI
Supply voltage
With respect to ground (2)
–2.0
–2.0
–25
–65
–65
7.0
7.0
V
DC input voltage
V
IOUT
TSTG
TAMB
TJ
DC output current, per pin
Storage temperature
Ambient temperature
Junction temperature
25
mA
° C
° C
° C
° C
No bias
150
135
150
135
Under bias
Ceramic packages, under bias
PQFP and RQFP, under bias
Altera Corporation
27
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 10. FLEX 8000 5.0-V Device Recommended Operating Conditions
Symbol
Parameter
Conditions
Min
Max
Unit
VCCINT Supply voltage for internal logic (3), (4)
4.75 (4.50)
5.25 (5.50)
V
and input buffers
VCCIO Supply voltage for output
buffers, 5.0-V operation
(3), (4)
(3), (4)
4.75 (4.50)
3.00 (3.00)
5.25 (5.50)
3.60 (3.60)
V
V
Supply voltage for output
buffers, 3.3-V operation
VI
Input voltage
–0.5
0
VCCINT + 0.5
V
V
VO
TA
Output voltage
VCCIO
70
Operating temperature
For commercial use
For industrial use
0
° C
° C
ns
ns
–40
85
tR
tF
Input rise time
Input fall time
40
40
Table 11. FLEX 8000 5.0-V Device DC Operating Conditions
Notes (5), (6)
Symbol
Parameter
Conditions
Min
Typ
Max
Unit
VIH
VIL
High-level input voltage
Low-level input voltage
2.0
–0.5
2.4
VCCINT + 0.5
0.8
V
V
V
VOH
5.0-V high-level TTL output
voltage
IOH = –4 mA DC (7)
VCCIO = 4.75 V
3.3-V high-level TTL output
voltage
I
OH = –4 mA DC (7)
2.4
V
V
V
V
V
VCCIO = 3.00 V
3.3-V high-level CMOS output IOH = –0.1 mA DC (7)
voltage
VCCIO – 0.2
VCCIO = 3.00 V
VOL
5.0-V low-level TTL output
voltage
IOL = 12 mA DC (7)
VCCIO = 4.75 V
0.45
0.45
0.2
3.3-V low-level TTL output
voltage
IOL = 12 mA DC (7)
VCCIO = 3.00 V
3.3-V low-level CMOS output IOL = 0.1 mA DC (7)
voltage
VCCIO = 3.00 V
II
Input leakage current
VI = VCC or ground
VO = VCC or ground
–10
–40
10
40
µA
µA
IOZ
Tri-state output off-state
current
ICC0
VCC supply current (standby) VI = ground, no load
0.5
10
mA
28
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 12. FLEX 8000 5.0-V Device Capacitance
Note (8)
Symbol
Parameter
Conditions
Min
Max
Unit
CIN
Input capacitance
VIN = 0 V, f = 1.0 MHz
VOUT = 0 V, f = 1.0 MHz
10
10
pF
pF
COUT
Output capacitance
Notes to tables:
(1) See the Operating Requirements for Altera Devices Data Sheet.
(2) Minimum DC input is –0.5 V. During transitions, the inputs may undershoot to –2.0 V or overshoot to 7.0 V for input
currents less than 100 mA and periods shorter than 20 ns.
(3) The maximum V
rise time is 100 ms.
CC
(4) Numbers in parentheses are for industrial-temperature-range devices.
(5) Typical values are for T = 25° C and V = 5.0 V.
A
CC
(6) These values are specified in Table 10 on page 28.
(7) The I parameter refers to high-level TTL or CMOS output current; the I parameter refers to low-level TTL or
OH
OL
CMOS output current.
(8) Capacitance is sample-tested only.
Tables 13 through 16 provide information on absolute maximum ratings,
recommended operating conditions, operating conditions, and
capacitance for 3.3-V FLEX 8000 devices.
3
Table 13. FLEX 8000 3.3-V Device Absolute Maximum Ratings
Note (1)
Symbol
Parameter
Conditions
Min
Max
Unit
VCC
VI
Supply voltage
With respect to ground (2)
–2.0
–2.0
–25
–65
–65
5.3
5.3
25
V
DC input voltage
V
IOUT
TSTG
TAMB
TJ
DC output current, per pin
Storage temperature
Ambient temperature
Junction temperature
mA
° C
° C
° C
No bias
150
135
135
Under bias
Plastic packages, under bias
Table 14. FLEX 8000 3.3-V Device Recommended Operating Conditions
Symbol
Parameter
Conditions
Min
Max
Unit
VCC
VI
Supply voltage
(3)
3.0
–0.3
0
3.6
VCC + 0.3
VCC
70
V
V
Input voltage
VO
TA
tR
Output voltage
Operating temperature
Input rise time
Input fall time
V
For commercial use
0
° C
ns
ns
40
tF
40
Altera Corporation
29
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 15. FLEX 8000 3.3-V Device DC Operating Conditions
Note (4)
Symbol
Parameter
Conditions
Min
Typ
Max
Unit
VIH
VIL
VOH
VOL
II
High-level input voltage
Low-level input voltage
High-level output voltage
Low-level output voltage
Input leakage current
2.0
–0.3
VCC + 0.3
0.8
V
V
IOH = –0.1 mA DC (5)
IOL = 4 mA DC (5)
VI = VCC or ground
VCC – 0.2
V
0.45
10
V
–10
–40
µA
µA
mA
IOZ
ICC0
Tri-state output off-state current VO = VCC or ground
VCC supply current (standby) VI = ground, no load (6)
40
0.3
10
Table 16. FLEX 8000 3.3-V Device Capacitance
Note (7)
Conditions
Symbol
Parameter
Min
Max
Unit
CIN
Input capacitance
Output capacitance
VIN = 0 V, f = 1.0 MHz
VOUT = 0 V, f = 1.0 MHz
10
10
pF
pF
COUT
Notes to tables:
(1) See the Operating Requirements for Altera Devices Data Sheet.
(2) Minimum DC input voltage is –0.3 V. During transitions, the inputs may undershoot to –2.0 V or overshoot to 5.3 V
for input currents less than 100 mA and periods shorter than 20 ns.
(3) The maximum V rise time is 100 ms. V must rise monotonically.
CC
CC
(4) These values are specified in Table 14 on page 29.
(5) The I parameter refers to high-level TTL output current; the I parameter refers to low-level TTL output current.
OH
OL
(6) Typical values are for T = 25° C and V = 3.3 V.
A
CC
(7) Capacitance is sample-tested only.
Figure 16 shows the typical output drive characteristics of 5.0-V
FLEX 8000 devices. The output driver is compliant with PCI Local Bus
Specification, Revision 2.2.
30
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Figure 16. Output Drive Characteristics of 5.0-V FLEX 8000 Devices (Except EPF8282A)
200
150
100
50
200
IOL
IOL
150
Typical I
Output
Current (mA)
O
Typical I
Output
O
Current (mA)
V
CCINT = 5.0 V
V
V
CCINT = 5.0 V
CCIO = 5.0 V
100
VCCIO = 3.3 V
Room Temperature
Room Temperature
IOH
IOH
50
1
2
3
4
1
2
3
4
5
Output Voltage (V)
Output Voltage (V)
Figure 17 shows the typical output drive characteristics of 5.0-V
EPF8282A devices. The output driver is compliant with PCI Local Bus
Specification, Revision 2.2.
3
Figure 17. Output Drive Characteristics of EPF8282A Devices with 5.0-V VCCIO
150
IOL
120
VCC = 5.0 V
Room Temperature
Typical I
Output
Current (mA)
O
90
60
30
IOH
1
2
3
4
5
Output Voltage (V)
Figure 18 shows the typical output drive characteristics of EPF8282AV
devices.
Altera Corporation
31
FLEX 8000 Programmable Logic Device Family Data Sheet
Figure 18. Output Drive Characteristics of EPF8282AV Devices
100
75
IOL
Typical I
Output
O
VCC = 3.3 V
50
Current (mA)
Room Temperature
IOH
25
1
2
3
4
Output Voltage (V)
The continuous, high-performance FastTrack Interconnect routing
structure ensures predictable performance and accurate simulation and
timing analysis. This predictable performance contrasts with that of
FPGAs, which use a segmented connection scheme and hence have
unpredictable performance. Timing simulation and delay prediction are
available with the MAX+PLUS II Simulator and Timing Analyzer, or with
industry-standard EDA tools. The Simulator offers both pre-synthesis
functional simulation to evaluate logic design accuracy and post-
synthesis timing simulation with 0.1-ns resolution. The Timing Analyzer
provides point-to-point timing delay information, setup and hold time
prediction, and device-wide performance analysis.
Timing Model
Tables 17 through 20 describe the FLEX 8000 timing parameters and their
symbols.
32
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 17. FLEX 8000 Internal Timing Parameters
Symbol
Note (1)
Parameter
tIOD
IOE register data delay
tIOC
IOE register control signal delay
Output enable delay
tIOE
tIOCO
tIOCOMB
tIOSU
tIOH
IOE register clock-to-output delay
IOE combinatorial delay
IOE register setup time before clock; IOE register recovery time after asynchronous clear
IOE register hold time after clock
tIOCLR
tIN
IOE register clear delay
Input pad and buffer delay
tOD1
tOD2
tOD3
tXZ
Output buffer and pad delay, slow slew rate = off, VCCIO = 5.0 V C1 = 35 pF (2)
Output buffer and pad delay, slow slew rate = off, VCCIO = 3.3 V C1 = 35 pF (2)
Output buffer and pad delay, slow slew rate = on, C1 = 35 pF (3)
Output buffer disable delay, C1 = 5 pF
tZX1
Output buffer enable delay, slow slew rate = off, VCCIO = 5.0 V, C1 = 35 pF (2)
Output buffer enable delay, slow slew rate = off, VCCIO = 3.3 V, C1 = 35 pF (2)
Output buffer enable delay, slow slew rate = on, C1 = 35 pF (3)
3
tZX2
tZX3
Table 18. FLEX 8000 LE Timing Parameters
Note (1)
Parameter
Symbol
tLUT
LUT delay for data-in
tCLUT
tRLUT
tGATE
tCASC
tCICO
tCGEN
tCGENR
tC
LUT delay for carry-in
LUT delay for LE register feedback
Cascade gate delay
Cascade chain routing delay
Carry-in to carry-out delay
Data-in to carry-out delay
LE register feedback to carry-out delay
LE register control signal delay
LE register clock high time
LE register clock low time
tCH
tCL
tCO
LE register clock-to-output delay
Combinatorial delay
tCOMB
tSU
LE register setup time before clock; LE register recovery time after asynchronous preset, clear, or
load
tH
LE register hold time after clock
LE register preset delay
LE register clear delay
tPRE
tCLR
Altera Corporation
33
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 19. FLEX 8000 Interconnect Timing Parameters
Note (1)
Parameter
Symbol
tLABCASC
tLABCARRY
tLOCAL
tROW
Cascade delay between LEs in different LABs
Carry delay between LEs in different LABs
LAB local interconnect delay
Row interconnect routing delay (4)
Column interconnect routing delay
Dedicated input to LE control delay
Dedicated input to LE data delay (4)
Dedicated input to IOE control delay
tCOL
tDIN_C
tDIN_D
tDIN_IO
Table 20. FLEX 8000 External Reference Timing Characteristics
Symbol Parameter
Note (5)
tDRR
tODH
Register-to-register delay via 4 LEs, 3 row interconnects, and 4 local interconnects (6)
Output data hold time after clock (7)
Notes to tables:
(1) Internal timing parameters cannot be measured explicitly. They are worst-case delays based on testable and
external parameters specified by Altera. Internal timing parameters should be used for estimating device
performance. Post-compilation timing simulation or timing analysis is required to determine actual worst-case
performance.
(2) These values are specified in Table 10 on page 28 or Table 14 on page 29.
(3) For the t
and t
parameters, V
= 3.3 V or 5.0 V.
OD3
ZX3
CCIO
(4) The t
and t
delays are worst-case values for typical applications. Post-compilation timing simulation or
ROW
DIN_D
timing analysis is required to determine actual worst-case performance.
(5) External reference timing characteristics are factory-tested, worst-case values specified by Altera. A representative
subset of signal paths is tested to approximate typical device applications.
(6) For more information on test conditions, see Application Note 76 (Understanding FLEX 8000 Timing).
(7) This parameter is a guideline that is sample-tested only and is based on extensive device characterization. This
parameter applies to global and non-global clocking, and for LE and I/O element registers.
The FLEX 8000 timing model shows the delays for various paths and
functions in the circuit. See Figure 19. This model contains three distinct
parts: the LE; the IOE; and the interconnect, including the row and column
FastTrack Interconnect, LAB local interconnect, and carry and cascade
interconnect paths. Each parameter shown in Figure 19 is expressed as a
worst-case value in Tables 22 through 49. Hand-calculations that use the
FLEX 8000 timing model and these timing parameters can be used to
estimate FLEX 8000 device performance. Timing simulation or timing
analysis after compilation is required to determine the final worst-case
performance. Table 21 summarizes the interconnect paths shown in
Figure 19.
For more information on timing parameters, go to Application Note 76
(Understanding FLEX 8000 Timing).
f
34
Altera Corporation
tROW
Carry-In from
Previous LE
Cascade-In from
Previous LE
LE
IOE
Register
Delays
Cascade
Gate Delay
I/O Register
Delays
Output
Delays
Output Data
Delay
LUT Delay
tLUT
I/O Pin
tOD1
tOD2
tOD3
tXZ
tGATE
tRLUT
tIOCO
tIOCOMB
tIOSU
tCO
tIOD
LE-Out
tCOMB
tSU
tCLUT
tIOH
tH
tZX1
tZX2
tZX3
I/O Register
Control
Carry Chain
Delay
tIOCLR
tPRE
tCLR
tLOCAL
tIOC
tCGEN
tCOL
tCGENR
tIOE
tCICO
Input
Delay
Register
Control
tIN
tC
Cascade
Routing Delay
tCASC
Data-In
Dedicated
Input Delays
tDIN_D
tDIN_C
tDIN_IO
tLABCASC
tLABCARRY
Cascade-Out Cascade-Out
to Next LE in to Next LE in
Carry-Out Carry-Out
to Next LE to Next LE
Next LAB
Same LAB
in Same
LAB
in Next
LAB
0
E X F 8 L 0 0
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 21. FLEX 8000 Timing Model Interconnect Paths
Source
Destination
Total Delay
tLOCAL
LE-Out
LE in same LAB
t
t
ROW + tLOCAL
LE-Out
LE in same row, different LAB
LE in different row
IOE on column
IOE on row
COL + tROW + tLOCAL
LE-Out
tCOL
LE-Out
tROW
LE-Out
tROW + tLOCAL
IOE on row
IOE on column
LE in same row
Any LE
t
COL + tROW + tLOCAL
Tables 22 through 49 show the FLEX 8000 internal and external timing
parameters.
Table 22. EPF8282A Internal I/O Element Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
0.7
1.7
1.7
1.0
0.3
Min
Max
Min
Max
0.9
1.9
1.9
1.0
0.1
tIOD
tIOC
tIOE
0.8
1.8
1.8
1.0
0.2
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
tIOCO
tIOCOMB
tIOSU
tIOH
1.4
0.0
1.6
0.0
1.8
0.0
tIOCLR
tIN
1.2
1.5
1.1
–
1.2
1.6
1.4
–
1.2
1.7
1.7
–
tOD1
tOD2
tOD3
tXZ
4.6
1.4
1.4
–
4.9
1.6
1.6
–
5.2
1.8
1.8
–
tZX1
tZX2
tZX3
4.9
5.1
5.3
36
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 23. EPF8282A Interconnect Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
0.3
0.3
0.5
4.2
2.5
5.0
7.2
5.0
Min
Max
Min
Max
0.4
0.4
0.8
4.2
2.5
5.5
7.2
5.5
tLABCASC
0.3
0.3
0.6
4.2
2.5
5.0
7.2
5.0
ns
ns
ns
ns
ns
ns
ns
ns
tLABCARRY
tLOCAL
tROW
tCOL
tDIN_C
tDIN_D
tDIN_IO
3
Altera Corporation
37
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 24. EPF8282A LE Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
Min
Max
Min
Max
tLUT
2.0
0.0
0.9
0.0
0.6
0.4
0.4
0.9
1.6
2.5
0.0
1.1
0.0
0.7
0.5
0.5
1.1
2.0
3.2
0.0
1.5
0.0
0.9
0.6
0.7
1.5
2.5
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
tCLUT
tRLUT
tGATE
tCASC
tCICO
tCGEN
tCGENR
tC
tCH
4.0
4.0
4.0
4.0
4.0
4.0
tCL
tCO
0.4
0.4
0.5
0.5
0.6
0.6
tCOMB
tSU
0.8
0.9
1.1
1.1
1.2
1.5
tH
tPRE
tCLR
0.6
0.6
0.7
0.7
0.8
0.8
Table 25. EPF8282A External Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
Min
Max
Min
Max
tDRR
tODH
15.8
19.8
24.8
ns
ns
1.0
1.0
1.0
38
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 26. EPF8282AV I/O Element Timing Parameters
Symbol Speed Grade
Unit
A-3
A-4
Min
Max
Min
Max
tIOD
0.9
1.9
1.9
1.0
0.1
2.2
2.0
2.0
2.0
0.0
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
tIOC
tIOE
tIOCO
tIOCOMB
tIOSU
tIOH
1.8
0.0
2.8
0.2
tIOCLR
tIN
1.2
1.7
1.7
–
2.3
3.4
4.1
–
tOD1
tOD2
tOD3
tXZ
3
5.2
1.8
1.8
–
7.1
4.3
4.3
–
tZX1
tZX2
tZX3
5.3
8.3
Table 27. EPF8282AV Interconnect Timing Parameters
Symbol
Speed Grade
Unit
A-3
A-4
Min
Max
Min
Max
tLABCASC
tLABCARRY
tLOCAL
tROW
0.4
0.4
0.8
4.2
2.5
5.5
7.2
5.5
1.3
0.8
ns
ns
ns
ns
ns
ns
ns
ns
1.5
6.3
tCOL
3.8
tDIN_C
8.0
tDIN_D
10.8
9.0
tDIN_IO
Altera Corporation
39
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 28. EPF8282AV Logic Element Timing Parameters
Symbol
Unit
Speed Grade
A-3
A-4
Min
Max
Min
Max
tLUT
3.2
0.0
1.5
0.0
0.9
0.6
0.7
1.5
2.5
7.3
1.4
5.1
0.0
2.8
1.5
2.2
3.7
4.7
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
tCLUT
tRLUT
tGATE
tCASC
tCICO
tCGEN
tCGENR
tC
tCH
4.0
4.0
6.0
6.0
tCL
tCO
0.6
0.6
0.9
0.9
tCOMB
tSU
1.2
1.5
2.4
4.6
tH
tPRE
tCLR
0.8
0.8
1.3
1.3
Table 29. EPF8282AV External Timing Parameters
Symbol Speed Grade
Unit
A-3
A-4
Min
Max
Min
Max
tDRR
tODH
24.8
50.1
ns
ns
1.0
1.0
40
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 30. EPF8452A I/O Element Timing Parameters
Symbol
Unit
Speed Grade
A-3
A-2
A-4
Min
Max
Min
Max
Min
Max
tIOD
tIOC
tIOE
0.7
1.7
1.7
1.0
0.3
0.8
1.8
1.8
1.0
0.2
0.9
1.9
1.9
1.0
0.1
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
tIOCO
tIOCOMB
tIOSU
tIOH
1.4
0.0
1.6
0.0
1.8
0.0
tIOCLR
tIN
1.2
1.5
1.1
–
1.2
1.6
1.4
–
1.2
1.7
1.7
–
tOD1
tOD2
tOD3
tXZ
3
4.6
1.4
1.4
–
4.9
1.6
1.6
–
5.2
1.8
1.8
–
tZX1
tZX2
tZX3
4.9
5.1
5.3
Table 31. EPF8452A Interconnect Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
Min
Max
Min
Max
tLABCASC
tLABCARRY
tLOCAL
tROW
0.3
0.3
0.5
5.0
3.0
5.0
7.0
5.0
0.4
0.4
0.5
5.0
3.0
5.0
7.0
5.0
0.4
0.4
0.7
5.0
3.0
5.5
7.5
5.5
ns
ns
ns
ns
ns
ns
ns
ns
tCOL
tDIN_C
tDIN_D
tDIN_IO
Altera Corporation
41
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 32. EPF8452A LE Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
Min
Max
Min
Max
tLUT
2.0
0.0
0.9
0.0
0.6
0.4
0.4
0.9
1.6
2.3
0.2
1.6
0.0
0.7
0.5
0.9
1.4
1.8
3.0
0.1
1.6
0.0
0.9
0.6
0.8
1.5
2.4
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
tCLUT
tRLUT
tGATE
tCASC
tCICO
tCGEN
tCGENR
tC
tCH
4.0
4.0
4.0
4.0
4.0
4.0
tCL
tCO
0.4
0.4
0.5
0.5
0.6
0.6
tCOMB
tSU
0.8
0.9
1.0
1.1
1.1
1.4
tH
tPRE
tCLR
0.6
0.6
0.7
0.7
0.8
0.8
Table 33. EPF8452A External Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
Min
Max
Min
Max
tDRR
tODH
16.0
20.0
25.0
ns
ns
1.0
1.0
1.0
42
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 34. EPF8636A I/O Element Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
Min
Max
Min
Max
tIOD
tIOC
tIOE
0.7
1.7
1.7
1.0
0.3
0.8
1.8
1.8
1.0
0.2
0.9
1.9
1.9
1.0
0.1
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
tIOCO
tIOCOMB
tIOSU
tIOH
1.4
0.0
1.6
0.0
1.8
0.0
tIOCLR
tIN
1.2
1.5
1.1
1.6
4.6
1.4
1.4
1.9
4.9
1.2
1.6
1.4
1.9
4.9
1.6
1.6
2.1
5.1
1.2
1.7
1.7
2.2
5.2
1.8
1.8
2.3
5.3
tOD1
tOD2
tOD3
tXZ
3
tZX1
tZX2
tZX3
Table 35. EPF8636A Interconnect Timing Parameters
Symbol
Unit
Speed Grade
A-3
A-2
A-4
Min
Max
Min
Max
Min
Max
tLABCASC
tLABCARRY
tLOCAL
tROW
0.3
0.3
0.5
5.0
3.0
5.0
7.0
5.0
0.4
0.4
0.5
5.0
3.0
5.0
7.0
5.0
0.4
0.4
0.7
5.0
3.0
5.5
7.5
5.5
ns
ns
ns
ns
ns
ns
ns
ns
tCOL
tDIN_C
tDIN_D
tDIN_IO
Altera Corporation
43
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 36. EPF8636A LE Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
Min
Max
Min
Max
tLUT
tCLUT
tRLUT
tGATE
tCASC
tCICO
tCGEN
tCGENR
tC
2.0
0.0
0.9
0.0
0.6
0.4
0.4
0.9
1.6
2.3
0.2
1.6
0.0
0.7
0.5
0.9
1.4
1.8
3.0
0.1
1.6
0.0
0.9
0.6
0.8
1.5
2.4
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
tCH
4.0
4.0
4.0
4.0
4.0
4.0
tCL
tCO
0.4
0.4
0.5
0.5
0.6
0.6
tCOMB
tSU
0.8
0.9
1.0
1.1
1.1
1.4
tH
tPRE
tCLR
0.6
0.6
0.7
0.7
0.8
0.8
Table 37. EPF8636A External Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
Min
Max
Min
Max
tDRR
tODH
16.0
20.0
25.0
ns
ns
1.0
1.0
1.0
44
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 38. EPF8820A I/O Element Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
Min
Max
Min
Max
tIOD
tIOC
tIOE
0.7
1.7
1.7
1.0
0.3
0.8
1.8
1.8
1.0
0.2
0.9
1.9
1.9
1.0
0.1
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
tIOCO
tIOCOMB
tIOSU
tIOH
1.4
0.0
1.6
0.0
1.8
0.0
tIOCLR
tIN
1.2
1.5
1.1
1.6
4.6
1.4
1.4
1.9
4.9
1.2
1.6
1.4
1.9
4.9
1.6
1.6
2.1
5.1
1.2
1.7
1.7
2.2
5.2
1.8
1.8
2.3
5.3
tOD1
tOD2
tOD3
tXZ
3
tZX1
tZX2
tZX3
Table 39. EPF8820A Interconnect Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
Min
Max
Min
Max
tLABCASC
0.3
0.3
0.5
5.0
3.0
5.0
7.0
5.0
0.3
0.3
0.6
5.0
3.0
5.0
7.0
5.0
0.4
0.4
0.8
5.0
3.0
5.5
7.5
5.5
ns
ns
ns
ns
ns
ns
ns
ns
tLABCARRY
tLOCAL
tROW
tCOL
tDIN_C
tDIN_D
tDIN_IO
Altera Corporation
45
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 40. EPF8820A LE Timing Parameters
Symbol
Unit
Speed Grade
A-3
A-2
A-4
Min
Max
Min
Max
Min
Max
tLUT
2.0
0.0
0.9
0.0
0.6
0.4
0.4
0.9
1.6
2.5
0.0
1.1
0.0
0.7
0.5
0.5
1.1
2.0
3.2
0.0
1.5
0.0
0.9
0.6
0.7
1.5
2.5
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
tCLUT
tRLUT
tGATE
tCASC
tCICO
tCGEN
tCGENR
tC
tCH
4.0
4.0
4.0
4.0
4.0
4.0
tCL
tCO
0.4
0.4
0.5
0.5
0.6
0.6
tCOMB
tSU
0.8
0.9
1.1
1.1
1.2
1.5
tH
tPRE
tCLR
0.6
0.6
0.7
0.7
0.8
0.8
Table 41. EPF8820A External Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
Min
Max
Min
Max
tDRR
tODH
16.0
20.0
25.0
ns
ns
1.0
1.0
1.0
46
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 42. EPF81188A I/O Element Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
Min
Max
Min
Max
tIOD
0.7
1.7
1.7
1.0
0.3
0.8
1.8
1.8
1.0
0.2
0.9
1.9
1.9
1.0
0.1
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
tIOC
tIOE
tIOCO
tIOCOMB
tIOSU
tIOH
1.4
0.0
1.6
0.0
1.8
0.0
tIOCLR
tIN
1.2
1.5
1.1
1.6
4.6
1.4
1.4
1.9
4.9
1.2
1.6
1.4
1.9
4.9
1.6
1.6
2.1
5.1
1.2
1.7
1.7
2.2
5.2
1.8
1.8
2.3
5.3
tOD1
tOD2
tOD3
tXZ
3
tZX1
tZX2
tZX3
Table 43. EPF81188A Interconnect Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
Min
Max
Min
Max
tLABCASC
tLABCARRY
tLOCAL
tROW
0.3
0.3
0.5
5.0
3.0
5.0
7.0
5.0
0.3
0.3
0.6
5.0
3.0
5.0
7.0
5.0
0.4
0.4
0.8
5.0
3.0
5.5
7.5
5.5
ns
ns
ns
ns
ns
ns
ns
ns
tCOL
tDIN_C
tDIN_D
tDIN_IO
Altera Corporation
47
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 44. EPF81188A LE Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
Min
Max
Min
Max
tLUT
tCLUT
tRLUT
tGATE
tCASC
tCICO
tCGEN
tCGENR
tC
2.0
0.0
0.9
0.0
0.6
0.4
0.4
0.9
1.6
2.5
0.0
1.1
0.0
0.7
0.5
0.5
1.1
2.0
3.2
0.0
1.5
0.0
0.9
0.6
0.7
1.5
2.5
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
tCH
4.0
4.0
4.0
4.0
4.0
4.0
tCL
tCO
0.4
0.4
0.5
0.5
0.6
0.6
tCOMB
tSU
0.8
0.9
1.1
1.1
1.2
1.5
tH
tPRE
tCLR
0.6
0.6
0.7
0.7
0.8
0.8
Table 45. EPF81188A External Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
Min
Max
Min
Max
tDRR
tODH
16.0
20.0
25.0
ns
ns
1.0
1.0
1.0
48
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 46. EPF81500A I/O Element Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
Min
Max
Min
Max
tIOD
tIOC
tIOE
0.7
1.7
1.7
1.0
0.3
0.8
1.8
1.8
1.0
0.2
0.9
1.9
1.9
1.0
0.1
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
tIOCO
tIOCOMB
tIOSU
tIOH
1.4
0.0
1.6
0.0
1.8
0.0
tIOCLR
tIN
1.2
1.5
1.1
1.6
4.6
1.4
1.4
1.9
4.9
1.2
1.6
1.4
1.9
4.9
1.6
1.6
2.1
5.1
1.2
1.7
1.7
2.2
5.2
1.8
1.8
2.3
5.3
tOD1
tOD2
tOD3
tXZ
3
tZX1
tZX2
tZX3
Table 47. EPF81500A Interconnect Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
Min
Max
Min
Max
tLABCASC
0.3
0.3
0.5
6.2
3.0
5.0
8.2
5.0
0.3
0.3
0.6
6.2
3.0
5.0
8.2
5.0
0.4
0.4
0.8
6.2
3.0
5.5
8.7
5.5
ns
ns
ns
ns
ns
ns
ns
ns
tLABCARRY
tLOCAL
tROW
tCOL
tDIN_C
tDIN_D
tDIN_IO
Altera Corporation
49
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 48. EPF81500A LE Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
Min
Max
Min
Max
tLUT
2.0
0.0
0.9
0.0
0.6
0.4
0.4
0.9
1.6
2.5
0.0
1.1
0.0
0.7
0.5
0.5
1.1
2.0
3.2
0.0
1.5
0.0
0.9
0.6
0.7
1.5
2.5
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
tCLUT
tRLUT
tGATE
tCASC
tCICO
tCGEN
tCGENR
tC
tCH
4.0
4.0
4.0
4.0
4.0
4.0
tCL
tCO
0.4
0.4
0.5
0.5
0.6
0.6
tCOMB
tSU
0.8
0.9
1.1
1.1
1.2
1.5
tH
tPRE
tCLR
0.6
0.6
0.7
0.7
0.8
0.8
Table 49. EPF81500A External Timing Parameters
Symbol
Speed Grade
A-3
Unit
A-2
A-4
Min
Max
Min
Max
Min
Max
tDRR
tODH
16.1
20.1
25.1
ns
ns
1.0
1.0
1.0
50
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
The supply power (P) for FLEX 8000 devices can be calculated with the
following equation:
Power
Consumption
P = PINT + PIO = [(ICCSTANDBY + ICCACTIVE × VCC] + PIO
)
Typical ICCSTANDBY values are shown as ICC0 in Table 11 on page 28 and
Table 15 on page 30. The PIO value, which depends on the device output
load characteristics and switching frequency, can be calculated using the
guidelines given in Application Note 74 (Evaluating Power for Altera
Devices). The ICCACTIVE value depends on the switching frequency and
the application logic. This value can be calculated based on the amount of
current that each LE typically consumes.
The following equation shows the general formula for calculating
ICCACTIVE
:
µA
MHz × LE
I
= K × fM × N × togLC × ---------------------------
AX
CCACTIVE
The parameters in this equation are shown below:
3
fMAX = Maximum operating frequency in MHz
N
= Total number of logic cells used in the device
togLC = Average percentage of logic cells toggling at each clock
= Constant, shown in Table 50
K
Table 50. Values for Constant K
Device
K
5.0-V FLEX 8000 devices
3.3-V FLEX 8000 devices
75
60
This calculation provides an ICC estimate based on typical conditions
with no output load. The actual ICC value should be verified during
operation because this measurement is sensitive to the actual pattern in
the device and the environmental operating conditions.
Figure 20 shows the relationship between ICC and operating frequency
for several LE utilization values.
Altera Corporation
51
FLEX 8000 Programmable Logic Device Family Data Sheet
Figure 20. FLEX 8000 ICCACTIVE vs. Operating Frequency
5.0-V FLEX 8000 Devices
1,000
1,500 LEs
800
600
400
200
1,000 LEs
500 LEs
I
Supply
CC
Current (mA)
0
30
60
Frequency (MHz)
3.3-V FLEX 8000 Devices
100
90
80
70
60
50
40
30
20
10
200 LEs
150 LEs
I
Supply
CC
Current (mA)
100 LEs
50 LEs
30
60
0
Frequency (MHz)
The FLEX 8000 architecture supports several configuration schemes to
load a design into the device(s) on the circuit board. This section
summarizes the device operating modes and available device
configuration schemes.
Configuration&
Operation
For more information, go to Application Note 33 (Configuring FLEX 8000
Devices) and Application Note 38 (Configuring Multiple FLEX 8000 Devices).
f
52
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Operating Modes
The FLEX 8000 architecture uses SRAM elements that require
configuration data to be loaded whenever the device powers up and
begins operation. The process of physically loading the SRAM
programming data into the device is called configuration. During
initialization, which occurs immediately after configuration, the device
resets registers, enables I/O pins, and begins to operate as a logic device.
The I/O pins are tri-stated during power-up, and before and during
configuration. The configuration and initialization processes together are
called command mode; normal device operation is called user mode.
SRAM elements allow FLEX 8000 devices to be reconfigured in-circuit
with new programming data that is loaded into the device. Real-time
reconfiguration is performed by forcing the device into command mode
with a device pin, loading different programming data, reinitializing the
device, and resuming user-mode operation. The entire reconfiguration
process requires less than 100 ms and can be used to dynamically
reconfigure an entire system. In-field upgrades can be performed by
distributing new configuration files.
3
Configuration Schemes
The configuration data for a FLEX 8000 device can be loaded with one of
six configuration schemes, chosen on the basis of the target application.
Both active and passive schemes are available. In the active configuration
schemes, the FLEX 8000 device functions as the controller, directing the
loading operation, controlling external configuration devices, and
completing the loading process. The clock source for all active
configuration schemes is an oscillator on the FLEX 8000 device that
operates between 2 MHz and 6 MHz. In the passive configuration
schemes, an external controller guides the FLEX 8000 device. Table 51
shows the data source for each of the six configuration schemes.
Table 51. Data Source for Configuration
Configuration Scheme
Acronym
Data Source
Active serial
AS
Altera configuration device
Parallel configuration device
Parallel configuration device
Serial data path
Active parallel up
APU
APD
PS
Active parallel down
Passive serial
Passive parallel synchronous
Passive parallel asynchronous
PPS
PPA
Intelligent host
Intelligent host
Altera Corporation
53
FLEX 8000 Programmable Logic Device Family Data Sheet
Tables 52 through 54 show the pin names and numbers for the dedicated
pins in each FLEX 8000 device package.
Device
Pin-Outs
Table 52. FLEX 8000 84-, 100-, 144- & 160-Pin Package Pin-Outs (Part 1 of 3)
Pin Name
84-Pin
PLCC
84-Pin
PLCC
100-Pin
TQFP
100-Pin
TQFP
144-Pin
TQFP
160-Pin
PGA
160-Pin
PQFP
EPF8282A EPF8452A EPF8282A EPF8452A EPF8820A EPF8452A EPF8820A
EPF8636A EPF8282AV (1)
nSP(2)
75
74
53
32
33
10
75
75
74
51
24
25
100
1
76
75
51
25
26
100
1
110
109
72
R1
P2
1
MSEL0(2)
MSEL1(2)
nSTATUS(2)
nCONFIG(2)
DCLK(2)
74
53
32
33
10
11
30
48
49
29
28
77
50
51
55
56
57
58
60
61
62
63
64
65
66
67
69
70
71
72
2
A1
44
82
81
125
124
87
89
110
118
121
100
107
40
39
38
37
36
32
30
28
26
22
20
18
16
11
10
8
37
C13
A15
P14
N13
F13
C6
B5
38
143
144
33
CONF_DONE(2) 11
nWS
30
48
49
29
28
77
50
51
36
56
57
58
60
61
62
63
64
65
66
67
69
70
71
76
22
42
45
21
19
77
47
49
28
55
57
58
59
60
61
62
64
65
66
67
68
69
71
76
23
45
46
22
21
78
47
48
54
55
57
58
60
61
62
64
65
66
67
68
70
71
72
73
nRS
31
RDCLK
nCS
12
4
D15
E15
P3
CS
3
RDYnBUSY
CLKUSR
ADD17
ADD16
ADD15
ADD14
ADD13
ADD12
ADD11
ADD10
ADD9
20
13
C5
B4
75
76
E2
77
D1
E1
78
79
F3
83
F2
85
F1
87
G2
G1
H1
H2
J1
89
ADD8
92
ADD7
94
ADD6
95
ADD5
97
J2
ADD4
102
103
104
105
K2
ADD3
K1
ADD2
K3
ADD1
M1
7
54
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 52. FLEX 8000 84-, 100-, 144- & 160-Pin Package Pin-Outs (Part 2 of 3)
Pin Name
84-Pin
PLCC
84-Pin
PLCC
100-Pin
TQFP
100-Pin
TQFP
144-Pin
TQFP
160-Pin
PGA
160-Pin
PQFP
EPF8282A EPF8452A EPF8282A EPF8452A EPF8820A EPF8452A EPF8820A
EPF8636A EPF8282AV (1)
ADD0
78
3
76
78
90
91
92
95
97
99
4
77
89
91
95
96
97
98
4
106
131
132
133
134
135
137
138
140
23
N3
P8
P10
R12
R13
P13
R14
N15
K13
P4
–
6
DATA7
2
140
139
138
136
135
133
132
129
97
DATA6
4
4
DATA5
6
6
DATA4
7
7
DATA3
8
8
DATA2
9
9
DATA1
13
14
79
55
27
72
20
52
13
DATA0
14
5
5
SDOUT(3)
TDI(4)
TDO(4)
TCK(4), (6)
TMS(4)
TRST(7)
78
79
54
18
72
11
50
79
–
45 (5)
27 (5)
44 (5)
43 (5)
52 (8)
96
17
3
–
18
–
102
27
–
88
–
–
86
–
29
–
71
–
45
Dedicated
12, 31, 54,
73
12, 31, 54, 3, 23, 53, 73 3, 24, 53,
73 74
17, 38, 59, 6, 20, 37, 56, 9, 32, 49,
80 70, 87 59, 82
9, 26, 82,
99
C3, D14,
N2, R15
14, 33, 94,
113
Inputs (10)
VCCINT
17, 38, 59,
80
8, 28, 70,
90, 111
B2, C4, D3, 3, 24, 46,
D8, D12,
G3, G12,
H4, H13,
J3, J12,
M4, M7,
M9, M13,
N12
92, 114,
160
VCCIO
–
–
–
–
16, 40, 60,
69, 91,
–
23, 47, 57,
69, 79,
112, 122,
141
104, 127,
137, 149,
159
Altera Corporation
55
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 52. FLEX 8000 84-, 100-, 144- & 160-Pin Package Pin-Outs (Part 3 of 3)
Pin Name
84-Pin
PLCC
84-Pin
PLCC
100-Pin
TQFP
100-Pin
TQFP
144-Pin
TQFP
160-Pin
PGA
160-Pin
PQFP
EPF8282A EPF8452A EPF8282A EPF8452A EPF8820A EPF8452A EPF8820A
EPF8636A EPF8282AV
(1)
GND
5, 26, 47, 68 5, 26, 47,
2, 13, 30, 44, 19, 44, 69, 7, 17, 27,
C12, D4,
D7, D9,
D13, G4,
G13, H3,
H12, J4,
J13, L1,
M3, M8,
M12, M15,
N4
12, 13, 34,
35, 51, 63,
75, 80, 83,
93, 103,
115, 126,
131, 143,
155
68
52, 63, 80,
94
94
39, 54,
80, 81,
100,101,
128, 142
No Connect
(N.C.)
–
–
–
2, 6, 13, 30,
37, 42, 43,
50, 52, 56,
63, 80, 87,
92, 93, 99
–
–
–
Total User I/O
64
64
74
64
108
116
116
Pins (9)
56
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 53. FLEX 8000 160-, 192- & 208-Pin Package Pin-Outs (Part 1 of 2)
Pin Name
160-Pin
PQFP
160-Pin
PQFP
192-Pin PGA
EPF8636A
208-Pin
PQFP
208-Pin
PQFP
208-Pin
PQFP
EPF8452A
EPF8636A
EPF8820A EPF8636A (1) EPF8820A (1) EPF81188A (1)
nSP(2)
120
1
3
R15
T15
T3
207
4
207
4
5
MSEL0(2)
MSEL1(2)
117
84
21
38
49
49
33
nSTATUS(2) 37
nCONFIG(2) 40
83
B3
108
103
158
153
108
103
158
153
124
107
154
138
81
C3
DCLK(2)
1
4
120
118
C15
B15
CONF_DONE
(2)
nWS
30
89
50
48
91
93
155
44
43
33
31
29
27
24
23
22
21
20
19
18
17
13
11
9
C5
114
66
114
116
137
145
148
127
134
43
118
121
137
142
144
128
134
46
nRS
71
B5
RDCLK
nCS
73
C11
B13
A16
A8
64
29
116
118
201
59
3
CS
27
RDYnBUSY
CLKUSR
ADD17
ADD16
ADD15
ADD14
ADD13
ADD12
ADD11
ADD10
ADD9
125
76
A10
R5
78
57
91
U3
43
42
45
92
T5
41
41
44
94
U4
39
40
39
95
R6
37
39
37
96
T6
31
35
36
97
R7
30
33
31
98
T7
29
31
30
99
T8
28
29
29
ADD8
101
102
103
104
105
106
109
110
123
144
150
152
U9
24
25
26
ADD7
U10
U11
U12
R12
U14
U15
R13
U16
H17
G17
F17
23
23
25
ADD6
22
21
24
ADD5
21
19
18
ADD4
14
14
17
ADD3
12
13
16
ADD2
10
11
10
ADD1
7
8
10
9
ADD0
157
137
132
129
203
178
172
169
9
8
DATA7
DATA6
DATA5
178
176
174
177
175
172
Altera Corporation
57
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 53. FLEX 8000 160-, 192- & 208-Pin Package Pin-Outs (Part 2 of 2)
Pin Name
160-Pin
PQFP
160-Pin
PQFP
192-Pin PGA
EPF8636A
208-Pin
PQFP
208-Pin
PQFP
208-Pin
PQFP
EPF8452A
EPF8636A
EPF8820A EPF8636A (1) EPF8820A (1) EPF81188A (1)
DATA4
154
127
E17
G15
F15
E16
C16
C7 (11)
R11
B9
165
162
160
149
147
198
72
172
171
167
165
162
124
20
170
168
166
163
161
119
–
DATA3
157
124
122
115
113
152
55
DATA2
159
DATA1
11
DATA0
12
SDOUT(3)
TDI(4)
TDO(4)
TCK(4), (6)
TMS(4)
TRST(7)
128
–
–
95
120
74
129
30
–
–
57
U8
–
–
59
U7
76
32
–
–
40
R3
54
54
–
Dedicated
5, 36, 85, 116
6, 35, 87, 116 A5, U5, U13, 7, 45, 112,
A13 150
17, 36, 121,
140
13, 41, 116,
146
Inputs (10)
VCCINT
21, 41, 53, 67,
4, 5, 26, 85,
C8, C9, C10, 5, 6, 33, 110, 5, 6, 27, 48,
4, 20, 35, 48,
50, 102, 114,
131, 147
(5.0 V)
80, 81, 100, 121, 106
133, 147, 160
R8, R9, R10, 137
R14
119, 141
VCCIO
(5.0 V or
3.3 V)
–
25, 41, 60, 70, D3, D4, D9,
32, 55, 78, 91, 26, 55, 69, 87, 3, 19, 34, 49,
80, 107, 121, D14, D15, G4, 102,138,159, 102,131,159, 69, 87, 106,
140, 149, 160 G14, L4, L14, 182, 193, 206 173, 191, 206 123, 140, 156,
P4, P9, P14
174, 192
GND
13, 14, 28, 46,
15, 16, 36, 37, C4, D7, D8,
19, 20, 46, 47, 15, 16, 37, 38, 11, 12, 27, 28,
60, 75, 93, 107, 45, 51, 75, 84, D10, D11, H4, 60, 67, 96,
60, 78, 96,
H14, K4, K14, 109,111,124, 109,110,120, 96, 105, 115,
117,126,131, P7, P8, P10, 125,151,164, 130,142,152, 122, 132, 139,
42, 43, 60, 78,
108, 126, 140,
155
86, 96, 97,
154
P11
171, 200
164, 182, 200 148, 155, 159,
165, 183, 201
No Connect 2, 3, 38, 39, 70, 2, 39, 82, 119 C6, C12, C13, 1, 2, 3, 16, 17, 1, 2, 3, 50, 51, 1, 2, 51, 52, 53,
(N.C.)
82, 83, 118, 119,
148
C14, E3, E15, 18, 25, 26, 27, 52, 53, 104,
F3, J3, J4, 34, 35, 36, 50, 105,106,107, 157, 158, 207,
J14, J15, N3, 51, 52, 53, 154,155,156, 208
N15, P3, P15, 104,105,106, 157, 208
54, 103, 104,
R4 (12)
107,121,122,
123,130,131,
132,139,140,
141,154,155,
156, 157, 208
Total User
116
114
132, 148 (13) 132
148
144
I/O Pins (9)
58
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 54. FLEX 8000 225-, 232-, 240-, 280- & 304-Pin Package Pin-Outs (Part 1 of 3)
Pin Name
225-Pin
BGA
232-Pin
PGA
240-Pin
PQFP
240-Pin
PQFP
280-Pin
PGA
304-Pin
RQFP
EPF8820A
EPF81188A
EPF81188A
EPF81500A
EPF81500A
EPF81500A
nSP(2)
A15
C14
237
237
W1
304
MSEL0(2)
MSEL1(2)
nSTATUS(2)
nCONFIG(2)
DCLK(2)
B14
R15
P2
G15
L15
L3
21
19
N1
26
40
38
H3
51
141
117
184
160
133
137
158
166
169
146
155
58
142
120
183
161
134
138
159
167
170
147
156
56
G19
B18
U18
M16
F18
G18
M17
N16
N18
J17
K19
E3
178
152
230
204
167
171
202
212
215
183
199
73
R1
R4
B2
C4
CONF_DONE(2) A1
G3
nWS
L4
P1
nRS
K5
N1
RDCLK
nCS
F1
G2
D1
E2
CS
C1
E3
3
RDYnBUSY
CLKUSR
ADD17
ADD16
ADD15
ADD14
ADD13
ADD12
ADD11
ADD10
ADD9
J3
K2
G2
H2
M14
L12
M15
L13
L14
K13
K15
J13
J15
G14
G13
G11
F14
E13
D15
D14
E12
C15
A7
R15
T17
P15
M14
M15
M16
K15
K17
J14
J15
H17
H15
F16
F15
F14
D15
B17
C15
A7
56
54
E2
71
54
52
F4
69
47
45
G1
60
45
43
H2
58
43
41
H1
56
36
34
J3
47
34
32
K3
45
32
30
K4
43
ADD8
29
27
L1
34
ADD7
27
25
L2
32
ADD6
25
23
M1
N2
30
ADD5
18
16
20
ADD4
16
14
N3
18
ADD3
14
12
N4
16
ADD2
7
5
U1
8
ADD1
5
3
U2
6
ADD0
3
1
V1
4
DATA7
DATA6
DATA5
205
203
200
199
197
196
W13
W14
W15
254
252
250
D7
D8
A6
B7
Altera Corporation
59
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 54. FLEX 8000 225-, 232-, 240-, 280- & 304-Pin Package Pin-Outs (Part 2 of 3)
Pin Name
225-Pin
BGA
232-Pin
PGA
240-Pin
PQFP
240-Pin
PQFP
280-Pin
PGA
304-Pin
RQFP
EPF8820A
EPF81188A
EPF81188A
EPF81500A
EPF81500A
EPF81500A
DATA4
A5
C7
198
194
W16
248
DATA3
DATA2
DATA1
DATA0
SDOUT(3)
TDI
B5
D7
B5
A3
A2
N2
–
196
194
191
189
135
–
193
W17
246
E6
190
V16
243
D5
189
U16
241
C4
187
V17
239
K1
136
F19
169
F15 (4)
J2 (4)
J14 (4)
J12 (4)
P14
63 (14)
117
B1 (14)
C17
80 (14)
149
TDO
–
–
TCK (6)
TMS
–
–
116 (14)
64 (14)
115 (14)
A19 (14)
C2 (14)
A18 (14)
148 (14)
81 (14)
145 (14)
–
–
TRST(7)
–
–
Dedicated Inputs F4, L1, K12, C1, C17, R1, 10, 51, 130,
8, 49, 131,
172
F1, F16, P3, 12, 64, 164,
P19 217
(10)
E15
R17
171
VCCINT
F5, F10, E1, E4, H4, L4,
L2, K4, M12, P12, L14,
20, 42, 64, 66, 18, 40, 60, 62, B17, D3, D15, 24, 54, 77,
114,128,150, 91, 114, 129, E8, E10, E12, 144, 79, 115,
(5.0 V)
P15, H13,
H14, B15,
C13
H14, E14,
R14, U1
172, 236
151,173,209, E14, R7, R9, 162,191,218,
236
R11, R13,
R14, T14
266, 301
VCCIO
H3, H2, P6,
N10, M13,
19, 41, 65, 81, 17, 39, 61, 78, D14, E7, E9, 22, 53, 78, 99,
(5.0 V or 3.3 V) R6, P10, N10, M5, K13, K5, 99, 116, 140, 94, 108, 130, E11, E13, R6, 119,137,163,
R14, N13,
H15, H12,
D12, A14,
B10, A10, B6,
C6, A2, C3,
M4, R2
H13, H5, F5, 162,186,202, 152,174,191, R8, R10, R12, 193,220,244,
E10, E8, N8, 220, 235
F13
205, 221, 235 T13, T15
262, 282, 300
60
Altera Corporation
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 54. FLEX 8000 225-, 232-, 240-, 280- & 304-Pin Package Pin-Outs (Part 3 of 3)
Pin Name
225-Pin
BGA
232-Pin
PGA
240-Pin
PQFP
240-Pin
PQFP
280-Pin
PGA
304-Pin
RQFP
EPF8820A
EPF81188A
EPF81188A
EPF81500A
EPF81500A
EPF81500A
GND
B1, D4, E14, A1, D6, E11, 8, 9, 30, 31,
F7, F8, F9, E7, E9, G4,
F12, G6, G7, G5, G13,
G8, G9, G10, G14, J5, J13, 139,151,161, 119,140,141, F15, G5, G15, 128, 150,
6, 7, 28, 29,
D4, D5, D16, 9, 11, 36, 38,
65, 67, 90,
108,115,129, 92, 101, 118, E15, E16, F5, 108, 116,
52, 53, 72, 90, 50, 51, 71, 85, E4, E5, E6,
H1, H4, H5,
H6, H7, H8,
K4, K14, L5, 173,185,187, 162,163,184, H5, H15, J5, 151,175,177,
L13, N4, N7, 193, 211, 229 185,186,198, J15, K5, K15, 206,208,231,
H9, H10, H11, N9, N11, N14
J6, J7, J8, J9,
208, 214, 228 L5, L15, M5, 232,237,253,
M15, N5,
265, 273, 291
J10, K6, K7,
N15, P4, P5,
P15, P16, R4,
R5, R15, R16,
T4, T5, T16,
U17
K8, K9, K11,
L15, N3, P1
No Connect
(N.C.)
–
–
61, 62, 119,
120,181,182,
239, 240
–
–
10, 21, 23, 25,
35, 37, 39, 40,
41, 42, 52, 55,
66, 68, 146,
147,161,173,
174,176,187,
188,189,190,
192,194,195,
205,207,219,
221,233,234,
235,236,302,
303
3
Total User I/O
148
180
180
177
204
204
Pins (9)
Altera Corporation
61
FLEX 8000 Programmable Logic Device Family Data Sheet
Notes to tables:
(1) Perform a complete thermal analysis before committing a design to this device package. See Application Note 74
(Evaluating Power for Altera Devices) for more information.
(2) This pin is a dedicated pin and is not available as a user I/O pin.
(3) SDOUTwill drive out during configuration. After configuration, it may be used as a user I/O pin. By default, the
MAX+PLUS II software will not use SDOUTas a user I/O pin; the user can override the MAX+PLUS II software and
use SDOUTas a user I/O pin.
(4) If the device is not configured to use the JTAG BST circuitry, this pin is available as a user I/O pin.
(5) JTAG pins are available for EPF8636A devices only. These pins are dedicated user I/O pins.
(6) If this pin is used as an input in user mode, ensure that it does not toggle before or during configuration.
(7) TRSTis a dedicated input pin for JTAG use. This pin must be grounded if JTAG BST is not used.
(8) Pin 52 is a V pin on EPF8452A devices only.
CC
(9) The user I/O pin count includes dedicated input pins and all I/O pins.
(10) Unused dedicated inputs should be tied to ground on the board.
(11) SDOUTdoes not exist in the EPF8636GC192 device.
(12) These pins are no connect (N.C.) pins for EPF8636A devices only. They are user I/O pins in EPF8820A devices.
(13) EPF8636A devices have 132 user I/O pins; EPF8820A devices have 148 user I/O pins.
(14) For EPF81500A devices, these pins are dedicated JTAG pins and are not available as user I/O pins. If JTAG BST is
not used, TDI, TCK, TMS, and TRSTshould be tied to GND.
The information contained in the FLEX 8000 Programmable Logic Device
Family Data Sheet version 11.1 supersedes information published in
previous versions. The FLEX 8000 Programmable Logic Device Family Data
Sheet version 11.1 contains the following change: minor textual updates.
Revision
History
62
Altera Corporation
相关型号:
©2020 ICPDF网 联系我们和版权申明