12717RFM1YR [AMPHENOL]
Board Connector, 17 Contact(s), 2 Row(s), Male, Straight, Solder Terminal, Plug,;型号: | 12717RFM1YR |
厂家: | Amphenol |
描述: | Board Connector, 17 Contact(s), 2 Row(s), Male, Straight, Solder Terminal, Plug, |
文件: | 总24页 (文件大小:1193K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
HE 8 / 127
Series
Connectors for PCB
Main features
The 127 series circuit board
connectors are in accordance with
several standards: NFC UTE 93424
(HE801, HE804 and HE807),
BS9525 (-N0001, -F0006 and -
F0007), MIL-C-55302 (140 to 155)
and CEI130-16.
The 127 series circuit board connectors are available in 3 different versions:
• HE 801 / 127: From 17 to 144 signal contacts, on 2 or 3 rows
Pin contacts with round sections
• HE 804 / 127: From 17 to 144 signal contacts, on 2 or 3 rows
Pin contacts with rectangular sections
• HE 807 / 127H: From 5 to 84 signal contacts and 3 to 10 size 16
cavities for power, coaxial contacts or optical termini
Pin contacts with round sections
The 127 series use a 1.27 mm
staggered pitch with 2.54 mm
between the rows.
Version
Insert height
(mm)
Pin signal contacts
Shape
Section (mm2)
Different versions are available, from
17 to 144 contacts, with different
terminations: straight, right angled,
crimp,solder, SMT and wire-wrap.
Mixed layout styles exist, providing
the addition of 3 to 10 cavities
HE 801
HE 804
HE 807
7.9
6.9
7.9
round, stamped
rectangular, cut-out
round, stamped
0.28
0.48
0.28
• Gold plating in accordance with NFC 93480: mini 0.8 µm Au
• Flexibility: 16 types of contacts, 25 types of fittings and 29 insert versions
• Crimp pin and socket contacts
accepting either power or coaxial
contacts as well as optical termini.
• Repairability: possibility to change the contacts one by one
• Density: up to 144 contacts within 150 mm long inserts
Low profile
rectangular
Technical characteristics
Temperature range
- 55°C / + 125°C (during 56 days)
Durability: - HE 801 & HE 804
- HE 807
500 cycles
250 cycles
PCB connectors
Insulation resistance
Salt spray
≥ 5000 MΩ
96 hours
2000/10 g
≤ 1µs
Vibrations
Electrical discontinuities
Shocks: - HE 801 & HE 804
- HE 807
100 g
50 g
Rating voltage at 50 Hz
Test voltage at sea level
Test current
250 Vrms
1000 Vrms
see curve
• Ground military and
Contact resistance
≤ 12 mΩ
≤ 5 pF
aircraft applications
Capacitance between contacts
• Telecom applications
• Avionics applications
Mating/unmating force per contacts:
- HE 801 0.14 N ≤ F ≤ 0.90 N
- HE 804 0.14 N ≤ F ≤ 1.60 N
0.14 N ≤ F ≤ 0.90 N (144 contacts)
- HE 807 0.14 N ≤ F ≤ 1.60 N
0.14 N ≤ F ≤ 0.90 N (84 + 10 contacts)
1 N ≤ F ≤ 15 N (coaxial contacts)
The 127 series connectors
are used among others
in the Mirage, Rafale and
Leclerc programs
Contact retention in the insert:
- HE 801
20 N for W contact
- HE 804 & HE 807 20 N for S, W and Z contacts
Torque values:
- nut for Ø 2.5 mm screw, brass 0.25 mN
- nut for Ø 1.6 mm screw, brass 0.15 mN
Arrangements
127 H – HE 807 Series
Dimensions
(mm)
127 – HE 801 / HE 804 Series
Contacts
Mating side view of plug
A
B
¤ ¤
¤
ꢀ
5
3
3
6
7
8
3
6
3
6
3
6
3
6
3
6
3
6
10
37.7 30.5
17
ꢁ
ꢁ
ꢀꢁ 17
5
0
52.9 45.7
29
0
58
50,8
33
41
ꢁ
ꢁ
ꢀꢁ 29
ꢀꢁ 17
ꢀꢁ 41
29
68.2 60.9
83.4 76.2
98.7 91.4
53
65
ꢁ
ꢁ
ꢀꢁ 53
ꢁ
41
60
48
ꢀ
113.9 106.7 72
129.1 121.9 84
ꢁ
ꢁ
ꢀꢁ 72
60
ꢀꢁ
84
144.4 137.1 96
ꢁ
ꢁ
72
56
2 rows:
e = 6.3 mm
3 rows:
83.4 76.2
80
80 cts: e = 8.94 mm max
144 cts: e = 8.55 mm max
144.4 137.1 144
¤
¤
ꢀ
ꢁ
signal contacts
special contacts
asymmetrical arrangements
crimp contacts possibility
2
C = 6.8 mm (HE 804) C = 7.8 mm (HE 801-807)
Contacts & fittings
Fittings
compatible with
Fittings
(HE
Fittings
compatible with
Type
Socket
contacts
socket contacts standard) pin contacts
Pin contacts Type
Installation
127 127 T 127 H 801 804 127 127 T 127 H
2 rows 3 rows
807
2 rows 3 rows
YC
YL*
T
A
A
A
101 101
103 103
J
A
D
D
D
D
S
YC
AS AS AS 124 124 JS
KE
AS
KE
KE 208 209 AE
KED 224 223 AED
KET 425 425 AET
KED
KET
KED
KET
PA
YL*
PA PA PA 102 102 PC
H
N
NF
NS
V
107
115 106
N
U
116 108 NF
126 126 NS
114 104
U
Y
V
For installation
instructions,
please refer
YD
Y
to pages 9 to 11
L
228
226
212 201
203 203
P
K
K
P
KD
KY
E
EF
ES
ET
T
S
SC
A
B
A
B
P
K
KD 221 221 AD AD
W3
W3
Z
KT 422 422 AT AT KD
E
117 110
R
R
KT
E
EF 119 112 RF RF
ES 125 125 RS RS EF
ET 327 327 RT RT ES
ZC
X
T
118 11
219 220
213
T
D
DC
ET
T
D
X1
S
IE 206
S
ꢀ Contact removal direction
* X and XL connectors + HE8C101, 102, 103 or 124 fixing accessories + longer screw (P/N 44322) for 3.2 mm PCB
Tooling
REMOVAL TOOLS
Pin
Removal
direction
Tool
1272
Socket
Removal
direction
Tool
Socket
Removal
Tool
contacts
contacts
contacts
direction
ZC-X-YC-YL
Y-W3-U
rear
YC-U-Z
rear
1271
W3
Y-YD
front
20973
20143
(HE801-804)
front
24098
YC-U-Z
(HE807)
rear
24099
HE807
particular contacts
rear
23550
CRIMPING TOOLS
Pin contacts
AWG
26 to 22
Tool
HE 8 20 051*
Socket
X1
AWG
26 to 22
Tool
809801
(M22520/2-01)
Turret
127.800 030
3
X
* No additional turret
Plugs – male fittings
COMPATIBLE FITTINGS
Fittings
HE
for contacts
socket pin
ꢁ
Recommended HE8C
P/N
Central fittings
Contacts
Description
127 HE8C 127 HE8C
S
T
YC
YL
T
P
804
801
807
A
A
A
101
101
101
102 PC
102 PC
102 PA
J
J
101
101
101
102
102
102
102
102
102
102
102
102
Codable. Unlockable
Daughter board
FREE PLUG
ꢁ
YC
YL
A
804 PA
801 PA
807 PA
Uncodable. Unlockable
Daughter or extensionboard
FREE PLUG
ꢁ
ꢁ
YC
YL
YC
YL
Codable. Unlockable. Surface
mount daughter board offset
from centerline, FREE PLUG
804
H
107
105
U
U
U
U
Codable. Unlockable. Surface
mount daughter board aligned
with centerline, FREE PLUG
804
801
804
801
N
N
V
V
106
115
104
114
N
N
V
V
106
115
104
114
104
114
104
114
Codable. Unlockable
Daughter board aligned
with centerline, FREE PLUG
U
U
804
801
807
804
801
807
804
E
E
E
T
T
T
D
110
117
117
111
118
118
103
R
R
E
T
T
T
S
110
117
117
111
118
118
103
113
129
129
113
129
129
102
W3 W3
Z,Y ZC
YD,X1 Y,X
W3 W3
Codable. Unlockable
For chassis or mother board
(board/board, board/chassis)
ꢁ
Uncodable
Unlockable
Z,Y
ZC
YD,X1 Y,X
T
Uncodable
Lockable on receptacle side
Daughter board
FREE PLUG
801
807
D
D
103
103
S
103
103
ꢁ
102
102
YC
YL
YC
YL
D
804 NF
801 NF
108 NF
116 NF
108
11
104
114
U
U
Lockable on receptacle side
Surface mount daughter
board aligned with centerline
804
801
807
EF
EF
EF
112 RF
119 RF
119 EF
112
119
119
113
129
129
W3 W3
Z,Y ZC
Uncodable
ꢁ
Lockable on receptacle side
For chassis or mother board
YD,X1 Y,X
T
804 AS
801 AS
807 AS
124 JS
124 JS
124 AS
124
124
124
102
102
102
Codable
Lockable on receptacle side
Daughter board
FREE PLUG
YC
YL
YC
YL
Codable.
804 NS
801 NS
126 NS
NS
126
104
114
U
U
Lockable on receptacle side.
Surface mount daughter
board aligned with centerline
804 ES
801 ES
807 ES
125 RS
125 RS
125 ES
125
125
125
113
129
129
W3 W3
Z,Y ZC
Codable
Lockable on receptacle side
For chassis or mother board
YD,X1 Y,X
804
ET
327 RT
327
313
W3 W3
Codable
Quarter turn lockable
Cable/card or cable/chassis
4
801
807
ET
ET
327 RT
327 ET
327
327
329
329
Z
ZC
X
X1
FOR A CONNECTOR’S MATING PAIR Receptacles – female fittings
Fittings
HE
for contacts
socket pin
127 HE8C 127 HE8C
ꢁ
Recommended HE8C
P/N
Central fittings
Contacts
Description
S
P
804
801
807
K
K
K
201
212
212
A
A
K
201
212
212
202
229
229
W3 W3
Codable. Unlockable
For chassis or mother board
FIXED RECEPTACLE
ꢁ
Z,Y
ZC
YD,X1 Y,X
W3 W3
804
801
P
P
203
203
B
B
203
203
202
229
Z,Y
YD
X1
ZC
Y
Codable. Unlockable
For chassis
FLOATING RECEPTACLE
ꢁ
807
P
226
P
226
209
229
209
X
T
804 KE
209 AE
YC
YL
T
YC
YL
U
Codable. Unlockable
Daughter board or board
to board mating
801 KE
807 KE
208 AE
208 KE
208
208
208
208
FREE RECEPTACLE
YC
YL
YC
YL
W3 W3
Codable. Unlockable
804
L
228
202
Z,Y
YD,X1 Y,X
ZC
ZC
for chassis or mother board
with insulating washer
Z
804
801
S
S
220
219
D
D
220
219
202
229
ꢁ
Uncodable.
Locking device-extractor
for cables
W3 W3
FREE RECEPTACLE
X1
Y
X
Y
804 SC
801 SC
207 DC
213 DC
207
202
for flex
W3 W3
213
213
221
229
229
202
Uncodable.
Locking device-extractor
for chassis
Z,Y
X1
ZC
FLOATING RECEPTACLE
807
S
213
S
Y,X
W3 W3
Codable. Locking by a
central captive screw +
screw-head retaining after
locking, ensuring resistance
to vibrations.
804 KD
221 AD
YD
X1
ZC
Y,X
W3 W3
X1 ZC
Z,Y Y,X
801 KD
807 KD
221 AD
221 KD
221
221
ꢁ
229
229
FIXED RECEPTACLE
YC
T
YC
YL
Codable. Locking by a central
captive screw + screw-head
retaining after locking, ensuring
resistance to vibrations.For
daughter board or board to board
mating. FREE RECEPTACLE
804 KED 223 AED 223
209
YL
T
YC
YL
801 KED 224 AED 224
807 KED 224 KED 224
208
208
YC
YL
W3,Z W3,X
804 KT
422 AT
422
402
X1
ZC
Y
Codable.
YD
Quarter turn locking
For chassis or mother board
FIXED RECEPTACLE
W3 W3
X1 ZC
Z,Y Z,Y
T
801 KT
807 KT
422 AT
422 KT
422
422
429
429
5
Codable. Quarter turn locking.
For daughter board or
board to board mating
FREE RECEPTACLE
804 KET 425 AET 425
801 KET 425 AET 425
807 KET 425 KET 425
425
425
425
YC
YL
YC
YL
Power, coaxial and optical contacts for HE 807 / 127 H connectors
POWER CONTACTS
Socket
P/N
P/N
Pin
Current rating 10 A
- straight
F121
- for hard soldering on wire
M121
- suitable for wire diameter up to 2 mm
- straight
- for hard soldering on mother board
- suitable for thickness board
3.2 mm max.
F141
F132
M141
M132
- right angled
- for hard soldering on daughter board
- suitable for thickness board
from 1.6 to 2.4 mm
Current rating 20 A
- straight
- right angled
- for hard soldering
- for hard
soldering on
- suitable for wire
daughter board
diameter up to 2 mm
F124
M134
on wire
- straight
- straight
- for mother board
- for bus bar
or bus bar
F164
FH1
M164
MH1
- straight
- for hard soldering on wire
- suitable for wire diameter up
to 1.83 mm
- straight
- for hard soldering on mother board
- suitable for thickness board
3.2 mm max.
FH2
FH3
MH2
MH3
- right angled
- for hard soldering on daughter board
- suitable for thickness board
from 1.6 to 2.4 mm
6
Power, coaxial and optical contacts for HE 807 / 127 H connectors
COAXIAL CONTACTS
Socket
P/N
P/N
Pin
- straight
F011
M011
- for hard soldering on flexible cable
- straight
- for hard soldering on flexible cable
- suitable for wire outer diameter
up to 2 mm
F021
M021
(KX 21 A / RG 178 B/U)
- straight
- for hard soldering on semi-rigid cable
- suitable for wire outer diameter
up to 2.16 mm
F061
F041
M061
M041
(KS 1 / RG 405 U)
- straight
- for hard soldering on mother board
- right angled
- for hard soldering on flexible cable
- suitable for wire outer diameter
up to 2 mm
F012
F032
M012
M032
(KX 21 A / RG 178 B/U)
- right angled
- for hard soldering on daughter board
- suitable for thickness board
from 1.6 to 2.4 mm
- righ angled
- for hard soldering on semi-rigid cable
- suitable for wire outer diameter
up to 2.16 mm
F052
M052
(KS 1 / RG 405 U)
Technical characteristics
Impedance ................................50 Ω
Voltage rating............................180 V
Current rating............................500 mA
Contact retention.......................≥ 50 N
Frequency range........................................................0 to 1 GHz
Contact resistance.....................................................≤ 12 mΩ
VSWR at 1 GHz .........................................................1.3 max.
Insertion and extraction force per contact..................1 N ≤ F ≤ 15 N
7
Power, coaxial and optical contacts for HE 807 / 127 H connectors
OPTICAL TERMINI
Straight pin
Straight
socket
Insert
Insert
Angled pin
Dimensions in mm
Technical characteristics
Fiber type........50/125, 62.5/125 and 100/140 µm
Cable type.......Ø 1.5 mm airborne tight jacket cable
equipped with 100/140/500 µm fiber
Material ..........- metallic body
Insertion loss............................0.5 dB (with 100/140 µm fibers)
Durability..................................250 cycles
Temperature range ....................- 55°C / + 125 °C
Cable retention by crimping .....> 10 daN
- ceramic ferrule
- ceramic alignment sleeve
How to order
Series (2 rows)
127 MD 16
C
15 CO
A1
Contact type
MD: Straight pin
MC: Angled pin
FD: Straight socket
Contact size
Ceramic ferrule
Cable type
A1: 50/62.5/125/500 µm
C1: 100/140 µm
Cable code
15: cable Ø 1.5 mm
For other cables, please consult us
Obligatory suffix
For installation instructions, please consult us.
8
Panel and printed circuit board drilling for
HE 801 – HE 804 / 127 connectors
Panel drilling
Receptacles
Plugs
Fittings Contacts Fittings Contacts
Pin
Pin
A-AD-AT
R-RF-RS-T
E-EF-ES-T
W3-ZC-X
W3-ZC-X
Fig. 1
Fig. 2
Socket
Socket
K-KD-KT-L
W3-Z
W3-Z
Pin
B
P
W3-ZC-X
Socket
W3-Z
Printed circuit board drilling
Daughterboard drilling for:
Receptacles Plugs
Fittings Contacts Fittings Contacts
KET
AET
A-D-AS-PA
Fig. 3
Fig. 4
Fig. 5
YC
YC
U
J-S-JS-PC
H-N-NF
NS-V
KE-KED
AE-AED
YC
Note:
The boards are illustrated from the connector side
The figures show the drilling of PC boards with connectors equipped with central guides (72, 84 and 96 contacts).
For smaller connectors (17, 29, 33, 41, 53 and 65 contacts), take no notice of the central drilling.
All contacts outputs are equidistant.
For daughterboards, the first contact’s marking is indicated as reference only.
Motherboard drilling for:
Receptacles
Plugs
Fittings Contacts Fittings Contacts
Y
Y
Fig. 6 A-AD-AT
Fig. 7 K-L-KD-KT
R-RF-RS-T
E-EF-ES-T
(pin)
(pin)
YD
YD
(socket)
(socket)
Dimensions (mm) – Refer to fig. 1 to 7
9
Number
17
29
33
41
53
65
72
84
96
of contacts
Dimension
30.48
25.90
45.72
41.10
50.80
46.20
60.96
56.40
76.20
71.60
91.44
86.90
106.68
102.10
121.92
117.30
137.16
132.60
B
Dimension
D
Panel and printed circuit board drilling for
HE 807 / 127 H connectors
Panel drilling
A
B
Receptacles
Pin contacts
Plugs
Pin contacts
signal special signal special
Fittings
Socket contacts Fittings
Socket contacts
signal special signal special
K
Please refer
to pages
6 to 8
Please refer
to pages
6 to 8
Please refer
to pages
6 to 8
Please refer
to pages
6 to 8
E
Please refer
to pages
6 to 8
Please refer
to pages
6 to 8
W3
W3
W3
W3
Fig. A
Fig. B
KD
KT
EF
ES
ZC-X
ZC-X1
ZC-X
ZC-X1
W3
W3
P
ZC-X
ZC-X1
Printed circuit board drilling
Daughterboard drilling for:
Receptacles Plugs
Note: (refering to the following page)
The boards are illustrated from the
connector side
Fittings
Contacts
signal coaxial
Fittings
Contacts
signal coaxial
The figures show the drilling of PC boards
with connectors equipped with central guides
(72, 84 and 96 contacts).
Fig. 1
A-D
KET
KE
YC F032/M032
YC F032/M032
AS-PA
on page 11
Fig. 2
For smaller connectors (17, 29, 33, 41, 53
and 65 contacts), take no notice of the
central drilling. All contacts outputs
are equidistant.
YC F032/M032
YC F032/M032
on page 11
Fig. 3
IE
on page 11
The illustrated drilling corresponds to
connectors fitted with 3 coaxial or power
contacts at one extremity and signal contacts
at the other one.
Fittings
Contacts
Fittings
Contacts
signal power
signal power
Fig. 5
FH3/MH3
A-D
FH3/MH3
KE
IE
YC
YC
on page 11
F132/M132 AS-PA
F132/M132
For daughterboards, the first contact’s
marking is indicated as reference only.
Fig. 6
FH3/MH3
YC
YC
on page 11
F132/M132
Fig. 7
FH3/MH3
IE
F132/M132
on page 11
Motherboard drilling for:
Receptacles Plugs
Fittings Contacts Contacts
signal coaxial signal coaxial
Fittings
K
A-D
Fig. 4
on page 11
KD
KT
Y
F041/M041 AS-PA YC F041/M041
Fittings
Contacts
signal power
Fittings
Contacts
signal power
K
FH2/MH2
A-D
FH2/MH2
Fig. 8
KD
KT
Y
F141/M141 AS-PA YC F141/M141
on page 11
Dimensions (mm) – Refer to fig. A and B and to fig. 1 to 8 on page 11
Number
5 + 3
17 + 3
5 + 6
0 + 7
0 + 8
29 + 3
17 + 6
41 + 3
29 + 6
53 + 3
41 + 6
60 + 3
48 + 6
72 + 3
60 + 6
84 + 3
72 + 6
56 + 10
of contacts
10
Dimension
B
17
29
41
53
65
72
84
96
Dimension
25.90
41.10
56.40
71.60
86.90
102.10
117.30
132.60
D
Printed circuit board drilling for HE 807 / 127 H connectors
Coaxial contacts
Power contacts
Daughter board
Daughter board
ꢀ
ꢁ
Daughter board
Daughter board
ꢂ
ꢃ
Daughter board
Daughter board
ꢄ
ꢅ
Mother board
Mother board
ꢆ
ꢇ
PCB drilling for 0 + 7 and 0 + 8 insert arrangements
F032/M032 contacts
F041/M041 contacts
FH2/MH2 contacts
FH3/MH3 contacts
F132/M132 contacts
F141/M141 contacts
11
For the 0 + 8 insert arrangement, the PCB drilling is the same one as the drilling for the 3 first contacts
of the 0 + 7 insert arrangement.
Hoods with locking rods for HE 804 plugs
Hoods are available for series HE 804 plugs. They are suitable for use with strand and ribbon cables, as well as flex circuits.
They suit to plugs supplied without fittings. The fittings, derived from the standard ones, are delivered with the hoods and
enable the polarisation.
These hoods are used with HE 804 plugs: - without fittings
- fitted with 29, 41 or 65 pin or socket contacts
- equipped with U, Z, ZC or X contacts
A hood is composed of the following parts (see fig. 1):
- 2 thermoplastic flanges (a)
- 2 locking rods (b)
- 1 inner cable clamp (c) for strand or flat cable depending
of the type of hood
- 2 fittings (d) to ensure the guiding and the polarisation
- the assembly screws
The working temperature is - 40°C to + 125°C.
(b) locked
(d) unlocked
Note:
For use with a strand cable,
break off the divisible part (see fig. 2, area x )
Dimensions (mm) – see fig. 2
Number
of
A
B
C
D
E
contacts
0.3
29
41
65
65.30
80.50
111.00
59.32
74.56
105.04
18.00
22.00
48.00
47.72
60.96
91.44
45.80
61.00
91.50
How to order
Series
127
29
TF
1
Number of contacts
29, 41, 65
Type of hood
TF: hood for female plug
TM: hood for male plug
12
Type of cable clamp
1: for flat cable or flex circuit
2: for strand cable
Plugs equipped with hoods mate with receptacles equipped with screwlock sockets (refer to page 13).
Locking systems for HE 804 plugs
These locking systems are used with HE 804 plugs: - without fittings
- fitted with 17, 29, 33, 41, 53 or 65 pin or socket contacts
- equipped with U, Z, ZC or X contacts
A set of locking systems is composed of the following parts (see fig. 1):
- 2 thermoplastic extremity blocks (a) equipped with
2 captive locking rods (b)
- 2 fittings (d) to ensure the guiding and the polarisation
The working temperature is - 40°C to + 125°C.
(b) locked
(d) unlocked
Note:
For use with ribbon cable or flex circuit, 2 epoxy glass strain relief stripes
can be supplied.
They are fastened to point (c) with PARKER CMB n°2 screws (4.8 mm long).
Dimensions (mm) – See fig. 2
Number
17
29
33
41
53
65
of contacts
Dimension
44.08
30.48
59.32
45.72
64.40
50.80
74.56
60.96
89.80
76.20
105.04
91.44
A*
* A: dimension between
the locking rods
Dimension
B*
B: dimension between the fittings
How to order
1 set of locking systems for male plug:
12 522
1 set of locking systems for female plug: 21 351
Plugs equipped with locking systems mate with receptacles equipped with screwlock sockets.
Screwlock sockets for HE 804 receptacles
These screwlock sockets allow the mating of HE 804 receptacles with plugs
equipped with hoods (refer to page 12) or locking systems (see above).
They are available in 2 versions:
- for perpendicular mounting to a chassis or a motherboard
- with brackets, for receptacles fitted with right angled contacts,
mounted on the edge of a daughter board
These screwlock sockets are used with HE 804 receptacles:
- without fittings
- fitted with 17, 29, 33, 41, 53 or 65 pin or socket contacts
- equipped with Z, ZC, YD, Y, W3 or X contacts for sockets
without brackets and YC contacts for sockets with brackets
A set of screwlock sockets is composed of the following parts (see fig. 1):
- 2 thermoplastic blocks (a) to be mounted at the extremities of the
receptacle. The inner metal tapped parts allow the locking of the plug
equipped with a hood or a locking system
13
- 2 fittings (b) with or without brackets (c) to mount the receptacle on the
panel. They mate with the fitting of the plug
The working temperature is - 40°C to + 125°C.
How to order
1 set of screwlock sockets without brackets for male or female receptacle:
21 347
21 349
1 set of screwlock sockets with brackets for male or female receptacle:
Dimensions
Fig. 1: sockets without brackets
Fig. 2: sockets with brackets (c) hole Ø 1.6 with 90° milling
Panel drilling
Fig. 3: for receptacles and screwlock sockets without brackets
max. panel thickness: 3.2 mm
Printed circuit board drilling
Motherboards with receptacles and screwlock
sockets without brackets
Fig. 4: for male receptacles with Y contacts max.
panel thickness: 3.2 mm
Fig. 5: for female receptacles with YD contacts max.
panel thickness: 2.4 mm
Daughterboards with receptacles and screwlock
sockets with brackets
Fig. 6: for male or female receptacles with YC contacts
Note:
The board is illustrated from the connector side
Dimensions (mm)
Number
17
29
33
41
53
65
of contacts
14
Dimension
44.08
30.48
25.90
59.32
45.72
41.10
64.40
50.80
46.20
74.56
60.96
56.40
89.80
76.20
71.60
105.04
91.44
86.90
A*
Dimension
B*
* A: dimension between
the locking rods
Dimension
C*
B: dimension between the fittings
HE 801 – HE 804 3-row female plugs
Series (3 rows) 127 T 144 A
F
1 YC N
–
–
Number of contacts (refer to p. 2)
80, 144
Fittings (refer to p. 4 - 5)
A, D, AS, PA, KE, KED: for plugs with 80 contacts
A, AS, D, PA, E: for plugs with 144 contacts
XL: without fitting (please order fittings separately -
refer to p. 19)
Contacts
F: socket contacts
Fittings material
Blank: nickel plated brass
1: stainless steel
Professional and military class
(1µm gold over nickel on contact area)
1: tinned plating on YC and Z terminations
Contact type
YC, Z, T
Model
N: HE 801
Blank: HE 804
Cavitities marking
Blank: normal (plug marking)
B: reversed marking (receptacle marking)
Underlined elements: recommended versions
HE 801 – HE 804 3-row male receptacles
Series (3 rows) 127 T 144 A
M
1 W3 R
–
–
Number of contacts (refer to p. 2)
80, 144
Fittings (refer to p. 4 - 5)
A, B, D, AD, AT
X: without fitting (please order fittings separately -
refer to p.19)
Contacts
M: pin contacts
Fittings material
Blank: nickel plated brass
1: stainless steel
Professional and military class
(1 µm gold over nickel on contact area)
1: tinned plating on Y, YC and ZC terminations
gold plating on W3 and X terminations
6: tinned plating on W3 terminations
Contact type
Y, W3, ZC
Model
R: HE 801
15
Blank: HE 804
Cavities marking
Blank: normal (receptacle marking)
B: reversed marking (plug marking)
Underlined elements: recommended versions
HE 801 – HE 804
2-row female plugs
127 17 A
Series (2 rows)
F
1 YC N
–
–
Number of contacts (refer to p. 2)
17,29,33,41,53,65,72,84,96
Fittings (refer to p. 4 - 5)
A, PA, AS, D, N, H (for HE 804 only), E, NF, NS,
EF, ES, ET, V
XL: without fitting (please order fittings separately -
refer to p. 19)
Contacts
F: socket contacts
Fittings material
Blank: nickel plated brass
1: stainless steel
Professional and military class
(1 µm gold over nickel on contact area)
1: tinned plating on YC, Y, Z, T, U and YL terminations
gold plating on W3 and X1 terminations
6: tinned plating on W3 terminations
Contact type
YC, U, T: for free plugs
W3, Z, YD, Y, X1: for fixed plugs
Model
N: HE 801
Blank: HE 804
Cavities marking
Blank: normal (plug marking)
B: reversed marking (receptacle marking)
Underlined elements: recommended versions
HE 801 – HE 804 2-row male receptacles
Series (2 rows)
Number of contacts (refer to p. 2)
127 96 A M –
1 ZC R
–
17,29,33,41,53,65,72,84,96
Fittings (refer to p. 4 - 5)
A, B, AE, D, DC, AD AED, AT, AET
X: without fitting (please order fittings separately -
refer to page 19)
Contacts
M: pin contacts
Fittings material
Blank: nickel plated brass
1: stainless steel
Professional and military class
(1 µm gold over nickel on contact area)
1: tinned plating on Y, YC, ZC, and YL terminations
gold plating on W3 and X terminations
6: tinned plating on W3 terminations
Contact type
YC: for free receptacles
W3, ZC, Y, X: for fixed receptacles
Model
R: HE 801
16
Blank: HE 804
Cavities marking
Blank: normal (receptacle marking)
B: reversed marking (plug marking)
Underlined elements: recommended versions
HE 801 – HE 804 2-row male plugs
Series (2 rows)
Number of contacts (refer to p. 2)
127 96 J
M
1 YC R
–
–
17,29,33,41,53,65,72,84,96
Fittings (refer to p. 4 - 5)
J, PC, JS, S, N, R, NF, NS, RF, RS, RT, V
XL: without fitting (please order fittings separately
- refer to p. 19)
Contacts
M: pin contacts
Fittings material
Blank: nickel plated brass
1: stainless steel
Professional and military class
(1 µm gold over nickel on contact area)
1: tinned plating on YC, Y, ZC, U and YL terminations
gold plating on W3 and X terminations
6: tinned plating on W3 terminations
Contact type
YC, U: for free plugs
W3, ZC, Y, X: for fixed plugs
Model
R: HE 801
Blank: HE 804
Cavities marking
Blank: normal (plug marking)
B: reversed marking (receptacle marking)
Underlined elements: recommended versions
HE 801 – HE 804 2-row female receptacles
Series (2 rows)
Number of contacts (refer to p. 2)
127 29 K
F
–
1
Y
N
–
17,29,33,41,53,65,72,84,96
Fittings (refer to p. 4 - 5)
K, P, KE, S, SC, KD, KED, KT, KET
X: without fitting (please order fittings separately -
refer to p.19)
Contacts
F: socket contacts
Fittings material
Blank: nickel plated brass
1: stainless steel
Professional and military class
(1 µm gold over nickel on contact area)
1: tinned plating on YD, Y, Z, YC and YL terminations
gold plating on W3 and X1 terminations
6: tinned plating on W3 terminations
Contact type
YC: for free receptacles
W3, YD, Y, Z, X1: for fixed receptacles
Model
N: HE 801
17
Blank: HE 804
Cavities marking
Blank: normal (receptacle marking)
B: reversed marking (plug marking)
Underlined elements: recommended versions
HE 807 male or female plugs
127 H 29 A
Series
F –
1 YC N 3A –
Number of signal contacts
(refer to p. 2)
5,17,29,41,48,56,60,72:
symmetrical arrangements
5,17,29,41,53,60,72,84:
asymmetrical arrangements
Fittings (refer to p. 4 - 5)
A,AS,D,E,EF,ES,ET,PA,T
XL: without fitting (please order fittings
separately - refer to p.19)
Contacts
F: socket contacts
M: pin contacts
Fittings material
Blank: nickel plated brass
1: stainless steel
Professional and military class
(1 µm gold over nickel on contact area)
1: tinned plating on YC, Y, Z, ZC and YL terminations
gold plating on W3, X and X1 terminations
6: tinned plating on W3 terminations
Contact type
YC, W3, X, X1, Z, ZC,Y, T
HE 807 model
N: Socket contacts
R: Pin contacts
Number of cavities for power, coaxial or optical contacts
3A: 3 cavities
6A: 6 cavities
10A: 10 cavities (please order power, coaxial and optical contacts separately -
refer to pages 6 to 8)
Contact marking
Blank: normal (plug marking)
B: reversed marking (receptacle marking)
Note: The asymmetrical arrangements ever have reversed marking on male plugs
Underlined elements: recommended versions
18
HE 807 male or female receptacles
Series
Number of signal contacts
(refer to p. 2)
127 H 29 A
F –
1 YC N 3A –
5,17,29,41,48,56,60,72:
symmetrical arrangements
5,17,29,41,53,60,72,84:
asymmetrical arrangements
Fittings (refer to p. 4 - 5)
IE,K,KE,KED,KET,KD,KT,P,S
X: without fitting (please order fittings
separately - refer to p. 19)
Contacts
F: socket contacts
M: pin contacts
Fittings material
Blank: nickel plated brass
1: stainless steel
Professional and military class
(1 µm gold over nickel on contact area)
1: tinned plating on YC, Y, Z, ZC and YL terminations
gold plating on W3, X and X1 terminations
6: tinned plating on W3 terminations
Contact type
YC, W3, X, X1, Z, ZC, Y
HE 807 model
N: Socket contacts
R: Pin contacts
Number of cavities for power, coaxial or optical contacts
3A: 3 cavities
6A: 6 cavities
10A: 10 cavities (pleade order power, coaxial and optical contacts separately -
refer to pages 6 to 8)
Contact marking
Blank: normal (plug marking)
B: reversed marking (receptacle marking)
Note: The asymmetrical arrangements ever have reversed marking on female receptacles
Underlined elements: recommended versions
HE 807 plugs
without signal contacts
HE 807 receptacles
without signal contacts
Insert with 7 cavities for specific contacts
without fittings
Insert with 7 cavities for specific contacts
without fittings
127 H 0 XL 0 1 00 H 7A
127 H 0 X 0 1 00 H 7A
Insert with 8 cavities for specific contacts
without fittings (recommended for
fiber optical applications)
Insert with 8 cavities for specific contacts
without fittings (recommended for
fiber optical applications)
127 H 0 XL 0 1 00 H 8A
127 H 0 X 0 1 00 H 8A
Fittings (for connectors ordered without fitting: XL or X)
Fitting
Fitting type
HE 8 C
101
19
1XX: male for plug - nickel plated brass
2XX: female for receptacle – nickel plated brass
3XX: male for plug – stainless steel
4XX: female for receptacle – stainless steel
For XX, please refer to charts on pages 4 and 5 (HE8C P/N)
Cross references chart HE 801 / 127
Connectors with 2 fitting locations (17, 29, 41, 53 and 65 contacts)
Connectors with fittings
Connectors
2 separate
fittings
Connectors with fittings
Connectors
2 separate
fittings
+
+
without fitting
without fitting
and
or
stainless
HE 801
references
HE 804 Amphenol
suffix P/N
Amphenol and brass or stainless
P/N fittings steel fittings
HE 801
HE 804
Amphenol
P/N
Amphenol
P/N
brass
references suffix
fittings steel fittings
HE 801 FB 17 Y 1 A 101 3 127 17 A F 1 YC N 127 17 XL F 1 YC N and HE 8 C 101 or HE 8 C 301
HE 801 ES 17 Z
1 A 212 3 127 17 K F 1 Z
N
N
127 17 X F 1 Z N and HE 8C 212 or HE 8C 412
127 17 X F 1 X1 N and HE 8C 212 or HE 8C 412
HE 801 FP 17 Y 1 A 101 3 127 17 J M 1 YC R
127 17 XL M 1 YC R and HE 8 C 101 or HE 8 C 301
HE 801 ES 17 S1 1 A 212 2 127 17 K F 1 X1
HE 801 FB 17 U 1 A 115 3 127 17 N F 1 U
HE 801 FP 17 U O A 115 3 127 17 N M 1 U
N
R
127 17 XL F 1 U N and HE 8 C 115 or HE 8 C 315
127 17 XL M 1 U R and HE 8 C 115 or HE 8 C 315
HE 801 EN 17 Y O A 212 3 127 17 A M 1Y
R
127 17 X F 1 Y R and HE 8C 212 or HE 8C 412
HE 801 EN 17 W O A 212 2 127 17 A M 1 W3 R 127 17 X F 1 W3 R and HE 8C 212 or HE 8C 412
HE 801 EN 17 Z
1 A 212 3 127 17 A M 1 ZC
R
R
127 17 X F 1 ZC R and HE 8C 212 or HE 8C 412
127 17 X F 1 X R and HE 8C 212 or HE 8C 412
HE 801 ES 17 Y O A 212 3 127 17 KF 1 Y
HE 801 ES 17 W O A 212 2 127 17 KF 1 W3 N
N
127 17 X F 1 Y
N and HE 8 C 212 or HE 8 C 412
HE 801 EN 17 S2 1 A 212 2 127 17 A M 1 X
127 17 X F 1 W3 N and HE 8 C 212 or HE 8 C 412
and
or
stainless
Amphenol
P/N
Amphenol
P/N
brass
Amphenol
P/N
Amphenol and brass or stainless
References issued
from HE 804
References issued
from HE 804
fittings steel fittings
P/N
fittings steel fittings
HE 801 ES 17 S1 1 A 000 2 127 17 X
HE 801 FS 17 S1 1 A 117 2 127 17 E
F
F
1 X1 N
1 X1 N 127 17 XL F 1 X1 N and HE 8 C 117 or HE 8 C 317
HE 801 FP 17 Y 1 A 102 3
HE 801 FP 17 Y 1 A 103 3
HE 801 EP 17 Y 1 A 208 3
HE 801 EP 17 Y 1 A 000 3
127 17 PC M 1 YC R 127 17 XL M 1 YC R and HE 8C 102 or HE 8C 302
127 17 S M 1 YC R 127 17 XL M 1 YC R and HE 8C 103 or HE 8C 303
127 17 AE M 1 YC R 127 17 X M 1 YC R and HE 8C 208 or HE 8C 408
127 17 X M 1 YC R
HE 301 FS 17 S1 1 A 000 2 127 17 XL F 1 X1 N
HE 801 EN 17 S2 1 A 000 2 127 17 X
HE 801 FN 17 S2 1 A 117 2 127 17 R
M
M
1 X
1 X
R
R
R
R
127 17 XL M 1 X
127 17 X M 1 X
R
R
and HE 8 C 117 or HE 8 C 317
and HE 8 C 203 or HE 8 C 403
HE 801 ES 17 Y 0 A 000 3
HE 801 FS 17 Y 0 A 117 3
HE 801 FS 17 Y 0 A 119 3
HE 801 FS 17 Y 0 A 125 3
HE 801 FS 17 Y 0 A 000 3
127 17 X
127 17 E
127 17 EF F 1 Y
127 17 ES F 1 Y
127 17 XL F 1 Y
F
F
1 Y
1 Y
N
N
N
N
N
HE 801 FN 17 S2 1 A 000 2 127 17 XL M 1 X
127 17 XL F 1 Y N and HE 8C 117 or HE 8C 317
127 17 XL F 1 Y N and HE 8C 119 or HE 8C 319
127 17 XL F 1 Y N and HE 8C 125 or HE 8C 325
HE 801 EN 17 S2 1 A 203 2 127 17 B
M
1 X
HE 801 ES 17 W 0 A 000 2 127 17 X
HE 801 FS 17 W 0 A 117 2 127 17 E
F
F
1 W3 N
1 W3 N 127 17 XL F 1 W3 N and HE 8 C 117 or HE 8 C 317
HE 801 ES 17 Z 1 A 000 3
HE 801 FS 17 Z 1 A 117 3
HE 801 FS 17 Z 1 A 119 3
HE 801 FS 17 Z 1 A 125 3
HE 801 FS 17 Z 1 A 000 3
127 17 X
127 17 E
127 17 EF F 1 Z
127 17 ES F 1 Z
127 17 XL F 1 Z
F
F
1 Z
1 Z
N
N
N
N
N
HE 801 EN 17 W 0 A 000 2 127 17 X
HE 801 FN 17 W 0 A 117 2 127 17 R
HE 801 EN 17 W 1 A 203 2 127 17 B
M
M
M
1 W3 R
127 17 XL F 1 Z N and HE 8C 117 or HE 8C 317
127 17 XL F 1 Z N and HE 8C 119 or HE 8C 319
127 17 XL F 1 Z N and HE 8C 125 or HE 8C 325
1 W3 R 127 17 XL W 1 W3 R and HE 8 C 117 or HE 8 C 317
1 W3 R 127 17 X M 1 W3 R and HE 8 C 203 or HE 8 C 403
HE 801 EN 17 Y 0 A 000 3 127 17 X
HE 801 FN 17 Y 0 A 117 3 127 17 R
M
M
1 Y
1 Y
R
R
R
R
R
R
127 17 XL M 1 Y
127 17 XL M 1 Y
127 17 XL M 1 Y
127 17 X M 1 Y
R
R
R
R
and HE 8 C 117 or HE 8 C 317
and HE 8 C 119 or HE 8 C 319
and HE 8 C 125 or HE 8 C 325
and HE 8 C 203 or HE 8 C 403
HE 801 EN 17 Z 1 A 000 3
HE 801 FN 17 Z 1 A 117 3
HE 801 FN 17 Z 1 A 119 3
HE 801 FN 17 Z 1 A 125 3
HE 801 EN 17 Z 1 A 203 3
HE 801 EN 17 Z 1 A 219 3
HE 801 FN 17 Z 1 A 000 3
127 17 X M 1 ZC R
HE 801 FN 17 Y 0 A 119 3 127 17 RF M 1 Y
HE 801 FN 17 Y 0 A 125 3 127 17 RS M 1 Y
127 17 R M 1 ZC R 127 17 XL M 1 ZC R and HE 8C 117 or HE 8C 317
127 17 RF M 1 ZC R 127 17 XL M 1 ZC R and HE 8C 119 or HE 8C 319
127 17 RS M 1 ZC R 127 17 XL M 1 ZC R and HE 8C 125 or HE 8C 325
127 17 B M 1 ZC R 127 17 X M 1 ZC R and HE 8C 203 or HE 8C 403
127 17 D M 1 ZC R
HE 801 EN 17 Y 0 A 203 3 127 17 B
M 1 Y
HE 801 FN 17 Y 0 A 000 3 127 17 XL M 1 Y
HE 801 FB 17 Y 1 A 000 3 127 17 XL F 1 YC N
HE 801 FB 17 Y 1 A 102 3 127 17 PA F 1 YC N
127 17 XL M 1 ZC R
127 17 XL F 1 YC N and HE 8 C 102 or HE 8 C 302
1 YC N 127 17 XL F 1 YC N and HE 8 C 103 or HE 8 C 303
127 17 X F 1 YC N and HE 8 C 208 or HE 8 C 408
HE 801 FB 17 Y 1 A 103 3 127 17 D
F
HE 801 FB 17 U 1 A 000 3
HE 801 FP 17 U 0 A 000 3
127 17 XL F 1 U
127 17 XL M 1 U
N
R
HE 801 EB 17 Y 1 A 208 3 127 17 KE F 1 YC N
HE 801 EB 17 Y 1 A 000 3 127 17 X 1 YC N
F
HE 801 FP 17 Y 1 A 000 3 127 17 XL M 1 YC R
Connectors with 3 fitting locations (72, 84 and 96 contacts)
and
HE 801
references
HE 804
suffix
Amphenol
P/N
Amphenol
P/N
brass or stainless steel
HE 801
2 extremity + 1 central fittings references
HE 8 C… HE 8 C…
HE 804
suffix
Amphenol
P/N
Amphenol
P/N
brass or stainless steel
2 extremity + 1 central fittings
HE 8 C… HE 8 C…
and
(no fitting)
(no fitting)
(no fitting)
(no fitting)
HE 801 FB 72 Y 1 A 101 3 127 72 A F 1 YC
N
127 72 XL F 1 YC
127 72 XL M 1 YC
N
R
and … 101 +…102 or …301 +…302 HE 801 ES 72 Z 1 B 212 3 127 72 K
and … 101 +…102 or …301 +…302 HE 801 FS 72 S1 1 A 212 2 127 72 K
F
F
1 Z
N
127 72 X
F
F
1 Z
1 X1
N
N
and … 212 +…229 or …412 +…429
and … 212 +…229 or …412 +…429
HE 801 FP 72 Y 1 A 101 3 127 72 J M 1 YC R
1 X1 N 127 72 X
HE 801 FB 72 Y 1 A 115 3 127 72 N F 1 U
HE 801 FP 72 Y 1 A 115 3 127 72 N M 1 U
N
R
127 72 XL F 1 U
N
R
and … 115 +…114 or …315 +…314 HE 801 EN 72 Y O A 212 3 127 72 A M 1 Y
R
127 72 X
M
M
M
M
1 Y R and … 212 +…229 or …412 +…429
1 W3 R and … 212 +…229 or …412 +…429
127 72 XL M
1
U
and … 115 +…114 or …315 +…314 HE 801 EN 72 W O A 212 2 127 72 A M 1 W3R 127 72 X
HE 801 EN 72 Z 1 B 212 3 127 72 A M 1 ZC R 127 72 X
1 ZC
1 X
R
R
and … 212 +…229 or …412 +…429
and … 212 +…229 or …412 +…429
HE 801 ES 72 Y O A 212 3 127 72 KF 1 Y
HE 801 ES 72 W O B 212 2 127 72 KF 1 W3 N
N
127 72 X
127 72 X
F
F
1 Y
N
and … 212 +…229 or …412 +…429
HE 801 EN 72 S2 1 A 212 2 127 72 A M 1 X
R
127 72 X
1 W3 N and … 212 +…229 or …412 +…429
and
or
stainless steel
Amphenol
P/N
(no fitting)
Amphenol
P/N
(no fitting)
brass
2 extremity + 1 central fittings
HE 8 C… HE 8 C…
Amphenol
P/N
(no fitting)
Amphenol and brass or stainless steel
References issued
from HE 801
References issued
from HE 801
P/N
2 extremity + 1 central fittings
HE 8 C… HE 8 C…
(no fitting)
HE 801 ES 72 S1 1 A 000 2 127 72 X
HE 801 FS 72 S1 1 A 117 2 127 72 E
F
F
1 X1 N
1 X1 N
HE 801 FP 72 Y 1 A 103 3
and … 117 +…129 or …317 +…329 HE 801 EP 72 Y 1 A 208 3
HE 801 EP 72 Y 1 A 000 3
127 72 S
M
1 YC R 127 72 XL M 1 YC R and … 103 +…102 or …302 +…302
1 YC R and … 208 +…208 or …408 +…408
127 72 XL F 1 X1
N
127 72 AE M 1 YC R 127 72 X
M
HE 801 FS 72 S1 1 A 000 2 127 72 XL F 1 X1 N
127 72 X
M
1 YC R
HE 801 EN 72 S2 1 A 000 2 127 72 X
HE 801 FN 72 S2 1 A 117 2 127 72 R
HE 801 EN 72 S2 1 A 203 2 127 72 B
M
M
M
1 X
1 X
1 X
R
R
R
R
HE 801 ES 72 Y 0 A 000 3
and … 117 +…117 or …317 +…329 HE 801 FS 72 Y 0 A 117 3
and … 203 +…203 or …403 +…429 HE 801 FS 72 Y 0 A 119 3
HE 801 FS 72 Y 0 A 125 3
127 72 X
127 72 E
127 72 EF F 1 Y
127 72 ES F 1 Y
127 72 XL F 1 Y
F
F
1 Y
1 Y
N
N
N
N
N
127 72 XL M 1 X
R
R
127 72 XL F 1 Y
127 72 XL F 1 Y
127 72 XL F 1 Y
N
N
N
and … 117 +…129 or …317 +…329
and … 119 +…129 or …319 +…329
and … 125 +…129 or …325 +…329
127 72 X
M
1 X
HE 801 FN 72 S2 1 A 000 2 127 72 XL M 1 X
HE 801 FS 72 Y 0 A 000 3
HE 801 ES 72 W 0 B 000 2 127 72 X
HE 801 FS 72 W 0 B 117 2 127 72 E
F
F
1 W3 N
1 W3 N 127 72 XL F 1 W3 N and … 117 +…117 or …317 +…329 HE 801 ES 72 Z 1 B 000 3
HE 801 FS 72 Z 1 B 117 3
127 72 X
127 72 E
127 72 EF F 1 Z
127 72 ES F 1 Z
127 72 XL F 1 Z
F
F
1 Z
1 Z
N
N
N
N
N
127 72 XL F 1 Z
127 72 XL F 1 Z
127 72 XL F 1 Z
N
N
N
and … 117 +…129 or …317 +…329
and … 119 +…129 or …319 +…329
and … 125 +…129 or …325 +…329
HE 801 EN 72 W 0 B 000 2 127 72 X
HE 801 FN 72 W 0 B 117 2 127 72 R
HE 801 EN 72 W 0 B 203 2 127 72 B
M
M
M
1 W3 R
HE 801 FS 72 Z 1 B 119 3
HE 801 FS 72 Z 1 B 125 3
HE 801 FS 72 Z 1 B 000 3
1 W3 R 127 72 XL M 1 W3 R and … 117 +…117 or …317 +…329
1 W3 R 127 72 X
M 1 W3 R and … 203 +…203 or …403 +…429
HE 801 ES 72 W 0 A 000 2 127 72 X FA 1 W3 N
HE 801 FS 72 W 0 A 117 2 127 72 E FA 1 W3 N
HE 801 EN 72 Z 1 B 000 3
HE 801 FN 72 Z 1 B 117 3
HE 801 FN 72 Z 1 B 119 3
HE 801 FN 72 Z 1 B 125 3
HE 801 EN 72 Z 1 B 203 3
HE 801 EN 72 Z 1 B 219 3
HE 801 FN 72 Z 1 B 000 3
127 72 X
127 72 R
M
M
1 ZC R
1 ZC R 127 72 XL M 1 ZC
127 72 XL FA 1 W3 N and … 117 +…117 or …317 +…329
R
R
R
and … 117 +…129 or …317 +…329
and … 119 +…129 or …319 +…329
and … 125 +…129 or …325 +…329
HE 801 ES 72 W 0 A 212 2 127 72 K FA 1 W3 N 127 72 X FA 1 W3 N and … 212 +…212 or …412 +…429
127 72 RF M 1 ZC R 127 72 XL M 1 ZC
127 72 RS M 1 ZC R 127 72 XL M 1 ZC
HE 801 EN 72 W 0 A 000 2 127 72 X MA 1 W3 R
HE 801 FN 72 W 0 A 117 2 127 72 R MA 1 W3 R 127 72 XL MA 1 W3 R and … 117 +…117 or …317 +…329
HE 801 EN 72 W 0 A 212 2 127 72 A MA 1 W3 R 127 72 X MA 1 W3 R and … 212 +…212 or …412 +…429
127 72 B
127 72 D
127 72 XL M 1 ZC R
M
M
1 ZC R 127 72 X
1 ZC R
M 1 ZC R and … 203 +…229 or …403 +…429
HE 801 EN 72 Y 0 A 000 3 127 72 X
HE 801 FN 72 Y 0 A 117 3 127 72 R
M
M
1 Y
1 Y
R
R
R
R
R
R
HE 801 ES 72 Z 1 A 000 3
HE 801 ES 72 Z 1 A 212 3
HE 801 FS 72 Z 1 A 117 3
HE 801 FS 72 Z 1 A 000 3
127 72 X FA 1 Z
127 72 K FA 1 Z
127 72 E FA 1 Z
127 72 XL FA 1 Z
N
N
N
N
127 72 XL M 1 Y
127 72 XL M 1 Y
127 72 XL M 1 Y
R
R
R
R
and … 117 +…117 or …317 +…329
and … 119 +…119 or …319 +…329
and … 125 +…125 or …325 +…329
and … 203 +…203 or …403 +…429
127 72 X FA 1 Z
127 72 XL FA 1 Z
N
N
and … 212 +…229 or …412 +…429
and … 117 +…129 or …317 +…329
HE 801 FN 72 Y 0 A 119 3 127 72 RF M 1 Y
HE 801 FN 72 Y 0 A 125 3 127 72 RS M 1 Y
HE 801 EN 72 Y 0 A 203 3 127 72 B
HE 801 FN 72 Y 0 A 000 3 127 72 XL M 1 Y
M
1 Y
127 72 X M 1 Y
20
HE 801 EN 72 Z 1 A 000 3
HE 801 EN 72 Z 1 A 212 3
HE 801 FN 72 Z 1 A 000 3
127 72 X MA 1 ZC R
127 72 A MA 1 ZC R 127 72 X MA 1 ZC R and … 212 +…229 or …412 +…429
127 72 XL MA 1 ZC R
HE 801 FB 72 Y 1 A 000 3 127 72 XL F 1 YC N
HE 801 FB 72 Y 1 A 102 3 127 72 PA F 1 YC N
127 72 XL F 1 YC N and … 102 +…102 or …302 +…302
127 72 XL F 1 YC N and … 103 +…102 or …303 +…302
127 72 X F 1 YC N and … 208 +…208 or …408 +…408
HE 801 FB 72 Y 1 A 103 3 127 72 D
F 1 YC N
HE 801 FB 72 U 1 A 000 3
HE 801 FB 72 U 1 A 115 3
127 72 XL F 1 U
127 72 N 1 U
N
N
HE 801 EB 72 Y 1 A 208 3 127 72 KE F 1 YC N
HE 801 EB 72 Y 1 A 000 3 127 72 X 1 YC N
F
127 72 XL F 1 U N and … 115 +…114 or …315 +…314
127 72 XL M 1 U R and … 115 +…114 or …315 +…314
F
HE 801 FP 72 U 0 A 000 3
HE 801 FP 72 U 1 A 115 3
127 72 XL M 1 U
127 72 N 1 U
R
N
HE 801 FP 72 Y 1 A 000 3 127 72 XL M 1 YC R
HE 801 FP 72 Y 1 A 102 3 127 72 PC M 1 YC R
M
127 72 XL M 1 YC R and … 102 +…102 or …302 +…302
Cross references chart HE 804 / 127
Connectors with 2 fitting locations (17, 29, 41, 53 and 65 contacts)
Connectors with fittings
Connectors
2 separate
fittings
Connectors with fittings
Connectors
2 separate
+
fittings
+
without fitting
without fitting
HE 804
references
Amphenol
P/N
Amphenol and brass or stainless
P/N fittings steel fittings
HE 804
references
Amphenol
P/N
Amphenol and brass or stainless
P/N fittings steel fittings
HE 804 ES 17 S1 1 A 000 2
HE 804 FS 17 S1 1 A 110 2
HE 804 FS 17 S1 1 A 112 2
HE 804 FS 17 S1 1 A 125 2
HE 804 ES 17 S1 1 A 201 2
127 17 X F 1X1
127 17 E F 1X1
127 17 EF F 1X1
127 17 ES F 1X1
127 17 K F 1X1
HE 804 FP 17 Y 1 A 000 3
HE 804 FP 17 Y 1 A 101 3
HE 804 FP 17 Y 1 A 102 3
HE 804 FP 17 Y 1 A 103 3
HE 804 EP 17 Y 1 A 209 3
127 17 XL M 1YC
127 17 XL F 1X1 and HE 8 C 110 or HE 8 C 310
127 17 XL F 1X1 and HE 8 C 112 or HE 8 C 312
127 17 XL F 1X1 and HE 8 C 125 or HE 8 C 325
127 17 X F 1X1 and HE 8 C 201 or HE 8 C 401
127 17 J M 1YC 127 17 XL M 1 YC and HE 8 C 101 or HE 8 C 301
127 17 PC M 1YC 127 17 XL M 1 YC and HE 8 C 102 or HE 8 C 302
127 17 S M 1YC 127 17 XL M 1 YC and HE 8 C 103 or HE 8 C 303
127 17 AE M 1YC 127 17 X M 1 YC and HE 8 C 209 or HE 8 C 409
HE 804 EN 17 S2 1 A 000 2
HE 804 FN 17 S2 1 A 110 2
HE 804 FN 17 S2 1 A 112 2
HE 804 FN 17 S2 1 A 125 2
HE 804 EN 17 S2 1 A 201 2
HE 804 EN 17 S2 1 A 203 2
HE 804 EN 17 S2 1 A 220 2
127 17 X M 1X
127 17 R M 1X
127 17 RF M 1X
127 17 RS M 1X
127 17 A M 1X
127 17 B M 1X
127 17 D M 1X
HE 804 ES 17 Y 0 A 000 3
HE 804 FS 17 Y 0 A 110 3
HE 804 FS 17 Y 0 A 112 3
HE 804 FS 17 Y 0 A 125 3
HE 804 ES 17 Y 0 A 201 3
127 17 X
127 17 E
F
F
1YD
127 17 XL M 1X and HE 8 C 110 or HE 8 C 310
127 17 XL M 1X and HE 8 C 112 or HE 8 C 312
127 17 XL M 1X and HE 8 C 125 or HE 8 C 325
127 17 X M 1X and HE 8 C 201 or HE 8 C 401
127 17 X M 1X and HE 8 C 203 or HE 8 C 403
127 17 X M 1X and HE 8 C 220 or HE 8 C 420
1YD 127 17 XL F 1 YD and HE 8 C 110 or HE 8 C 310
127 17 EF F 1YD 127 17 XL F 1 YD and HE 8 C 112 or HE 8 C 312
127 17 ES F 1YD 127 17 XL F 1 YD and HE 8 C 125 or HE 8 C 325
127 17 K
F
1YD 127 17 X F 1 YD and HE 8 C 201 or HE 8 C 401
HE 804 ES 17 Z 1 A 000 3
HE 804 FS 17 Z 1 A 110 3
HE 804 FS 17 Z 1 A 112 3
HE 804 FS 17 Z 1 A 125 3
HE 804 ES 17 Z 1 A 201 3
127 17 X
127 17 E
F
F
1Z
1Z
127 17 XL F 1 Z and HE 8 C 110 or HE 8 C 310
127 17 XL F 1 Z and HE 8 C 112 or HE 8 C 312
127 17 XL F 1 Z and HE 8 C 125 or HE 8 C 325
127 17 X F 1 Z and HE 8 C 201 or HE 8 C 401
HE 804 ES 17 W 0 A 000 2
HE 804 FS 17 W 0 A 110 2
HE 804 FS 17 W 0 A 112 2
HE 804 FS 17 W 0 A 125 2
HE 804 ES 17 W 0 A 201 2
127 17 X F 1W3
127 17 E F 1W3
127 17 EF F 1W3
127 17 ES F 1W3
127 17 K F 1W3
127 17 EF F 1Z
127 17 ES F 1Z
127 17 XL F 1W3 and HE 8 C 110 or HE 8 C 310
127 17 XL F 1W3 and HE 8 C 112 or HE 8 C 312
127 17 XL F 1W3 and HE 8 C 125 or HE 8 C 325
127 17 X F 1W3 and HE 8 C 201 or HE 8 C 401
127 17 K
F 1Z
HE 804 EN 17 Z 1 A 000 3
HE 804 FN 17 Z 1 A 110 3
HE 804 FN 17 Z 1 A 112 3
HE 804 FN 17 Z 1 A 125 3
HE 804 EN 17 Z 1 A 201 3
HE 804 EN 17 Z 1 A 203 3
HE 804 EN 17 Z 1 A 220 3
127 17 X M 1ZC
127 17 R M 1ZC 127 17 XL M 1 ZC and HE 8 C 110 or HE 8 C 310
127 17 RF M 1ZC 127 17 XL M 1 ZC and HE 8 C 112 or HE 8 C 312
127 17 RS M 1ZC 127 17 XL M 1 ZC and HE 8 C 125 or HE 8 C 325
127 17 A M 1ZC 127 17 X M 1 ZC and HE 8 C 201 or HE 8 C 401
127 17 B M 1ZC 127 17 X M 1 ZC and HE 8 C 203 or HE 8 C 403
127 17 D M 1ZC 127 17 X M 1 ZC and HE 8 C 220 or HE 8 C 420
HE 804 EN 17 W 0 A 000 2
HE 804 FN 17 W 0 A 110 2
HE 804 FN 17 W 0 A 112 2
HE 804 FN 17 W 0 A 125 2
HE 804 EN 17 W 0 A 201 2
HE 804 EN 17 W 0 A 203 2
HE 804 EN 17 W 0 A 220 2
127 17 X M 1W3
127 17 R M 1W3
127 17 RF M 1W3
127 17 RS M 1W3
127 17 A M 1W3
127 17 B M 1W3
127 17 D M 1W3
127 17 XL M 1W3 and HE 8 C 110 or HE 8 C 310
127 17 XL M 1W3 and HE 8 C 112 or HE 8 C 312
127 17 XL M 1W3 and HE 8 C 125 or HE 8 C 325
127 17 X M 1W3 and HE 8 C 201 or HE 8 C 401
127 17 X M 1W3 and HE 8 C 203 or HE 8 C 403
127 17 X M 1W3 and HE 8 C 220 or HE 8 C 420
HE 804 FC 17 U 1 A 000 3
HE 804 FC 17 U 1 A 106 3
HE 804 FC 17 U 1 A 108 3
127 17 XL F 1U
127 17 N
F
1U
127 17 XL F 1 U and HE 8 C 106 or HE 8 C 306
127 17 XL F 1 U and HE 8 C 108 or HE 8 C 308
HE 804 EN 17 Y 0 A 000 3
HE 804 FN 17 Y 0 A 110 3
HE 804 FN 17 Y 0 A 112 3
HE 804 FN 17 Y 0 A 125 3
HE 804 EN 17 Y 0 A 201 3
HE 804 EN 17 Y 0 A 203 3
127 17 X M 1Y
127 17 R M 1Y
127 17 RF M 1Y
127 17 RS M 1Y
127 17 A M 1Y
127 17 B M 1Y
127 17 NF F 1U
127 17 XL M 1Y and HE 8 C 110 or HE 8 C 310
127 17 XL M 1Y and HE 8 C 112 or HE 8 C 312
127 17 XL M 1Y and HE 8 C 125 or HE 8 C 325
127 17 X M 1Y and HE 8 C 201 or HE 8 C 401
127 17 X M 1Y and HE 8 C 203 or HE 8 C 403
HE 804 FD 17 U 1 A 000 3
HE 804 FD 17 U 1 A 107 3
HE 804 FD 17 U 1 A 109 3
HE 804 FD 17 U 1 A 105 3
127 17 XL F 1U
127 17 H
127 17 HF F 1U
127 17 G 1U
F
1U
127 17 XL F 1 U and HE 8 C 107 or HE 8 C 307
127 17 XL F 1 U and HE 8 C 109 or HE 8 C 309
127 17 XL F 1 U and HE 8 C 105 or HE 8 C 305
F
HE 804 FP 17 U 0 A 000 3
HE 804 FP 17 U 0 A 106 3
HE 804 FP 17 U 0 A 108 3
HE 804 FP 17 U 0 A 104 3
127 17 XL M 1U
127 17 N M 1U
127 17 NF M 1U
127 17 V M 1U
HE 804 FB 17 Y 1 A 000 3
HE 804 FB 17 Y 1 A 101 3
HE 804 FB 17 Y 1 A 102 3
HE 804 FB 17 Y 1 A 103 3
HE 804 EB 17 Y 1 A 209 3
127 17 XL F 1YC
127 17 A F 1YC
127 17 PA F 1YC
127 17 D F 1YC
127 17 KE F 1YC
127 17 XL M 1 U and HE 8 C 106 or HE 8 C 306
127 17 XL M 1 U and HE 8 C 108 or HE 8 C 308
127 17 XL M 1 U and HE 8 C 104 or HE 8 C 304
127 17 XL F 1YC and HE 8 C 101 or HE 8 C 301
127 17 XL F 1YC and HE 8 C 102 or HE 8 C 302
127 17 XL F 1YC and HE 8 C 103 or HE 8 C 303
127 17 X F 1YC and HE 8 C 209 or HE 8 C 409
Connectors with 3 fitting locations (72, 84 and 96 contacts)
HE 804
references
Amphenol
P/N
Amphenol
P/N
brass
stainless steel
HE 804
Amphenol
P/N
Amphenol and brass stainless steel
or
or
2 extremity + 1 central fittings
HE 8 C… HE 8 C…
and
references
P/N
(no fitting)
2 extremity + 1 central fittings
(no fitting)
(no fitting)
(no fitting)
HE 8 C…
HE 8 C…
HE 804 ES 72 S1 1 A 000 2
HE 804 FS 72 S1 1 A 110 2
HE 804 FS 72 S1 1 A 112 2
HE 804 FS 72 S1 1 A 125 2
HE 804 ES 72 S1 1 A 201 2
127 72 X
127 72 E
F
F
1X1
1X1
HE 804 FS 72 Z 1 B 112 3
HE 804 FS 72 Z 1 B 125 3
HE 804 ES 72 Z 1 B 201 3
127 72 EF F 1Z
127 72 ES F 1Z
127 72 XL F 1 Z
127 72 XL F 1 Z
127 72 X F 1 Z
and … 112 +…113
and … 125 +…113
and … 201 +…202
or …312 +…313
or …325 +…313
or …401 +…402
127 72 XL F 1 X1 and … 110 +…113 or …310 +…313
127 72 XL F 1 X1 and … 112 +…113 or …312 +…313
127 72 XL F 1 X1 and … 125 +…113 or …325 +…313
127 72 X F 1 X1 and … 201 +…202 or …401 +…402
127 72 EF F 1X1
127 72 ES F 1X1
127 72 K F 1Z
HE 804 EN 72 Z 1 B 000 3
HE 804 FN 72 Z 1 B 110 3
HE 804 FN 72 Z 1 B 112 3
HE 804 FN 72 Z 1 B 125 3
HE 804 EN 72 Z 1 B 201 3
HE 804 EN 72 Z 1 B 203 3
HE 804 EN 72 Z 1 B 220 3
127 72 X M 1ZC
127 72 K
F 1X1
127 72 R M 1ZC 127 72 XL M 1 Z C and … 110 +…113 or …310 +…313
127 72 RF M 1ZC 127 72 XL M 1 Z C and … 112 +…113 or …312 +…313
127 72 RS M 1ZC 127 72 XL M 1 Z C and … 125 +…113 or …325 +…313
127 72 A M 1ZC 127 72 X M 1 Z C and … 201 +…202 or …401 +…402
127 72 B M 1ZC 127 72 X M 1 Z C and … 203 +…202 or …403 +…402
127 72 D M 1ZC 127 72 X M 1 Z C and … 220 +…202 or …420 +…402
HE 804 EN 72 S2 1 A 000 2
HE 804 FN 72 S2 1 A 110 2
HE 804 FN 72 S2 1 A 112 2
HE 804 FN 72 S2 1 A 125 2
HE 804 EN 72 S2 1 A 201 2
HE 804 EN 72 S2 1 A 203 2
HE 804 EN 72 S2 1 A 220 2
127 72 X M 1X
127 72 R M 1X
127 72 RF M 1X
127 72 RS M 1X
127 72 A M 1X
127 72 B M 1X
127 72 D M 1X
127 72 XL M 1 X and … 110 +…113 or …310 +…313
127 72 XL M 1 X and … 112 +…113 or …312 +…313
127 72 XL M 1 X and … 125 +…113 or …325 +…313
127 72 X M 1 X and … 201 +…202 or …401 +…402
127 72 X M 1 X and … 203 +…202 or …403 +…402
127 72 X M 1 X and … 220 +…202 or …420 +…402
HE 804 ES 72 W 0 A 000 2
HE 804 FS 72 W 0 A 112 2
HE 804 FS 72 W 0 A 125 2
HE 804 ES 72 W 0 A 201 2
127 72 X FA 1W3
127 72 EF FA 1W3 127 72 XL FA 1 W3 and … 113 +…113 or …312 +…313
127 72 S FA 1W3 127 72 XL FA 1 W3 and … 113 +…113 or …325 +…313
127 72 K FA 1W3 127 72 X FA 1 W3 and … 202 +…202 or …401 +…402
HE 804 ES 72 W 0 B 000 2
HE 804 FS 72 W 0 B 110 2
HE 804 FS 72 W 0 B 112 2
HE 804 FS 72 W 0 B 125 2
HE 804 ES 72 W 0 B 201 2
127 72 X
127 72 E
F
F
1W3
1W3
127 72 XL F 1 W3 and … 110 +…113 or …310 +…313
127 72 XL F 1 W3 and … 112 +…113 or …312 +…313
127 72 XL F 1 W3 and … 125 +…113 or …325 +…313
127 72 X F 1 W3 and … 201 +…202 or …401 +…402
127 72 EF F 1W3
127 72 ES F 1W3
HE 804 EN 72 W 0 A 000 2
HE 804 FN 72 W 0 A 110 2
HE 804 FN 72 W 0 A 111 2
HE 804 FN 72 W 0 A 112 2
HE 804 FN 72 W 0 A 125 2
HE 804 EN 72 W 0 A 201 2
HE 804 EN 72 W 0 A 220 2
127 72 X MA 1W3
127 72 R MA 1W3 127 72 XL MA 1 W3 and … 113 +…113 or …310 +…313
127 72 T MA 1W3 127 72 XL MA 1 W3 and … 113 +…113 or …311 +…313
127 72 RF MA 1W3 127 72 XL MA 1 W3 and … 113 +…113 or …312 +…313
127 72 RS MA 1W3 127 72 XL MA 1 W3 and … 113 +…113 or …325 +…313
127 72 A MA 1W3 127 72 X MA 1 W3 and … 202 +…202 or …401 +…402
127 72 D MA 1W3 127 72 X MA 1 W3 and … 202 +…202 or …420 +…402
127 72 K
F 1W3
HE 804 EN 72 W 0 B 000 2
HE 804 FN 72 W 0 B 110 2
HE 804 FN 72 W 0 B 112 2
HE 804 FN 72 W 0 B 125 2
HE 804 EN 72 W 0 B 201 2
HE 804 EN 72 W 0 B 203 2
HE 804 EN 72 W 0 B 220 2
127 72 X M 1W3
127 72 R M 1W3
127 72 RF M 1W3
127 72 RS M 1W3
127 72 A M 1W3
127 72 B M 1W3
127 72 D M 1W3
127 72 XL M 1 W3 and … 110 +…113 or …310 +…313
127 72 XL M 1 W3 and … 112 +…113 or …312 +…313
127 72 XL M 1 W3 and … 125 +…113 or …325 +…313
127 72 X M 1 W3 and … 201 +…202 or …401 +…402
127 72 X M 1 W3 and … 203 +…202 or …403 +…402
127 72 X M 1 W3 and … 220 +…202 or …420 +…402
HE 804 ES 72 Z 1 A 000 3
HE 804 FS 72 Z 1 A 110 3
HE 804 FS 72 Z 1 A 112 3
HE 804 FS 72 Z 1 A 125 3
HE 804 ES 72 Z 1 A 201 3
127 72 X FA 1Z
127 72 E FA 1Z
127 72 F FA 1Z
127 72 ES FA 1Z
127 72 K FA 1Z
127 72 XL FA 1 Z and … 110 +…113
127 72 XL FA 1 Z and … 112 +…113
127 72 XL FA 1 Z and … 125 +…113
127 72 X FA 1 Z and … 201 +…202
or …310 +…313
or …312 +…313
or …325 +…313
or …401 +…402
HE 804 EN 72 Y 0 A 000 3
HE 804 FN 72 Y 0 A 110 3
HE 804 FN 72 Y 0 A 112 3
HE 804 FN 72 Y 0 A 125 3
HE 804 EN 72 Y 0 A 201 3
HE 804 EN 72 Y 0 A 203 3
127 72 X M 1Y
127 72 R M 1Y
127 72 RF M 1Y
127 72 RS M 1Y
127 72 A M 1Y
127 72 B M 1Y
127 72 XL M 1 Y and … 110 +…113 or …310 +…313
127 72 XL M 1 Y and … 112 +…113 or …312 +…313
127 72 XL M 1 Y and … 125 +…113 or …325 +…313
127 72 X M 1 Y and … 201 +…202 or …401 +…402
127 72 X M 1 Y and … 203 +…202 or …403 +…402
HE 804 EN 72 Z 1 A 000 3
HE 804 FN 72 Z 1 A 110 3
HE 804 FN 72 Z 1 A 112 3
HE 804 FN 72 Z 1 A 125 3
HE 804 EN 72 Z 1 A 201 3
HE 804 EN 72 Z 1 A 203 3
HE 804 EN 72 Z 1 A 220 3
127 72 X MA 1ZC
127 72 R MA 1ZC 127 72 XL MA 1 ZC and … 110 +…113 or …310 +…313
127 72 RF MA 1ZC 127 72 XL MA 1 ZC and … 112 +…113 or …312 +…313
127 72 RS MA 1ZC 127 72 XL MA 1 ZC and … 125 +…113 or …325 +…313
127 72 A MA 1ZC 127 72 X MA 1 ZC and … 201 +…202 or …401 +…402
127 72 B MA 1ZC 127 72 X MA 1 ZC and … 203 +…202 or …403 +…402
127 72 D MA 1ZC 127 72 X MA 1 ZC and … 220 +…202 or …420 +…402
HE 804 FB 72 Y 1 A 000 3
HE 804 FB 72 Y 1 A 101 3
HE 804 FB 72 Y 1 A 102 3
HE 804 FB 72 Y 1 A 103 3
HE 804 EB 72 Y 1 A 209 3
127 72 XL F 1YC
127 72 A
F
1YC
127 72 XL F 1 YC and … 101 +…102 or …301 +…302
127 72 XL F 1 YC and … 102 +…102 or …302 +…302
127 72 XL F 1 YC and … 103 +…102 or …303 +…303
127 72 X F 1 YC and … 209 +…209 or …409 +…409
127 72 PA F 1YC
127 72 D
F 1YC
HE 804 FC 72 U 1 A 000 3
HE 804 FC 72 U 1 A 104 3
HE 804 FC 72 U 1 A 106 3
HE 804 FC 72 U 1 A 108 3
127 72 XL F 1U
127 72 KE F 1YC
127 72 V
127 72 N
F
F
1U
1U
127 72 XL F 1 U
127 72 XL F 1 U
127 72 XL F 1 U
and … 104 +…104
and … 106 +…104
and … 108 +…104
or …304 +…304
or …306 +…304
or …308 +…304
HE 804 FP 72 Y 1 A 000 3
HE 804 FP 72 Y 1 A 101 3
HE 804 FP 72 Y 1 A 102 3
HE 804 FP 72 Y 1 A 103 3
HE 804 EP 72 Y 1 A 209 3
127 72 XL M 1YC
127 72 J M 1YC
127 72 PC M 1YC
127 72 S M 1YC
127 72 AE M 1YC
127 72 XL M 1 YC and … 101 +…102 or …301 +…302
127 72 XL M 1 YC and … 102 +…102 or …302 +…302
127 72 XL M 1 YC and … 103 +…102 or …303 +…302
127 72 X M 1 YC and … 209 +…209 or …409 +…409
127 72 NF F 1U
21
HE 804 FD 72 U 1 A 000 3
HE 804 FD 72 U 1 A 107 3
HE 804 FD 72 U 1 A 109 3
HE 804 FD 72 U 1 A 105 3
127 72 XL F 1U
127 72 H
127 72 HF F 1U
127 72 G 1U
F
1U
127 72 XL F 1 U
127 72 XL F 1 U
127 72 XL F 1 U
and … 107 +…105
and … 109 +…105
and … 105 +…105
or …307 +…305
or …309 +…305
or …305 +…305
HE 804 ES 72 Y 0 A 000 3
HE 804 FS 72 Y 0 A 110 3
HE 804 FS 72 Y 0 A 112 3
HE 804 FS 72 Y 0 A 125 3
HE 804 ES 72 Y 0 A 201 3
127 72 X
127 72 E
127 72 F
127 72 ES F 1YD
127 72 K
F
F
F
1YD
1YD
1YD
F
127 72 XL F 1 YD and … 110 +…113 or …310 +…313
127 72 XL F 1 YD and … 112 +…113 or …312 +…313
127 72 XL F 1 YD and … 125 +…113 or …325 +…313
127 72 X F 1 YD and … 201 +…202 or …401 +…402
HE 804 FP 72 U 0 A 000 3
HE 804 FP 72 U 0 A 106 3
HE 804 FP 72 U 0 A 108 3
HE 804 FP 72 U 0 A 104 3
127 72 XL M 1U
127 72 N 1U
127 72 NF M 1U
127 72 V 1U
M
127 72 XL M 1 U and … 106 +…104
127 72 XL M 1 U and … 108 +…104
127 72 XL M 1 U and … 104 +…104
or …306 +…304
or …308 +…304
or …304 +…304
F
1YD
M
HE 804 ES 72 Z 1 B 000 3
HE 804 FS 72 Z 1 B 110 3
127 72 X
127 72 E
F
F
1Z
1Z
127 72 XL F 1 Z and … 110 +…113 or …310 +…313
Cross references chart HE 807 / 127 H
Connectors with 2 fitting locations
Connectors with fittings
Connectors
+
2 separate fittings
without fitting
HE 807
Amphenol
P/N
Amphenol P/N
and
2 brass fittings
or
2 stainless
references
without fitting
steel fittings
ASYMETRICAL ARRANGEMENTS
HE 807 FB 17 Y 1 A 3 000 3
HE 807 FB 17 Y 1 A 3 101 3
HE 807 FB 17 Y 1 A 3 102 3
HE 807 FB 17 Y 1 A 3 103 3
127 H 17 XL F 1 YC N 3A
127 H 17 A F 1 YC N 3A
127 H 17 PA F 1 YC N 3A
127 H 17 D F 1 YC N 3A
127 H 17 XL F 1 YC N 3A
127 H 17 XL F 1 YC N 3A
127 H 17 XL F 1 YC N 3A
127 H 17 XL F 1 YC N 3A
and
and
and
HE8C 101
HE8C 102
HE8C 103
or
or
or
HE8C 301
HE8C 302
HE8C 303
HE 807 FB 17 Y 1 A 3 206 3
HE 807 FB 17 Y 1 A 3 208 3
127 H 17 IE F 1 YC N 3AB
127 H 17 KE F 1 YC N 3AB
127 H 17 XL F 1 YC N 3A
127 H 17 XL F 1 YC N 3A
and
and
HE8C 206
HE8C 208
or
or
HE8C 406
HE8C 408
HE 807 EP 17 Y 1 A 3 000 3
HE 807 EP 17 Y 1 A 3 101 3
HE 807 EP 17 Y 1 A 3 102 3
HE 807 EP 17 Y 1 A 3 103 3
127 H 17 X M 1 YC R 3A
127 H 17 A M 1 YC R 3AB
127 H 17 PA M 1 YC R 3AB
127 H 17 D M 1 YC R 3AB
127 H 17 X M 1 YC R 3A
127 H 17 X M 1 YC R 3A
127 H 17 X M 1 YC R 3A
127 H 17 X M 1 YC R 3A
and
and
and
HE8C 101
HE8C 102
HE8C 103
or
or
or
HE8C 301
HE8C 302
HE8C 303
HE 807 EP 17 Y 1 A 3 206 3
HE 807 EP 17 Y 1 A 3 208 3
127 H 17 IE M 1 YC R 3A
127 H 17 KE M 1 YC R 3A
127 H 17 X M 1 YC R 3A
127 H 17 X M 1 YC R 3A
and
and
HE8C 206
HE8C 208
or
or
HE8C 406
HE8C 408
HE 807 FS 17 W 0 A 3 000 2
HE 807 FS 17 W 0 A 3 117 2
HE 807 FS 17 W 0 A 3 212 2
HE 807 FS 17 W 0 A 3 213 2
HE 807 FS 17 W 0 A 3 226 2
127 H 17 XL F 1 W3 N 3A
127 H 17 XL F 1 W3 N 3A
127 H 17 XL F 1 W3 N 3A
127 H 17 XL F 1 W3 N 3A
127 H 17 XL F 1 W3 N 3A
127 H 17 XL F 1 W3 N 3A
127 H 17 E
F
1 W3 N 3A
and
and
and
and
HE8C 117
HE8C 212
HE8C 213
HE8C 226
or
or
or
or
HE8C 317
HE8C 412
HE8C 413
HE8C 426
127 H 17 K F 1 W3 N 3AB
127 H 17 S F 1 W3 N 3AB
127 H 17 P F 1 W3 N 3AB
HE 807 EN 17 W 0 A 3 000 2
HE 807 EN 17 W 0 A 3 212 2
HE 807 EN 17 W 0 A 3 213 2
127 H 17 X M 1 W3 R 3A
127 H 17 K M 1 W3 R 3A
127 H 17 S M 1 W3 R 3A
127 H 17 X M 1 W3 R 3A
127 H 17 X M 1 W3 R 3A
127 H 17 X M 1 W3 R 3A
and
and
HE8C 212
HE8C 213
or
or
HE8C 412
HE8C 413
HE 807 EN 17 W 0 A 3 117 2
127 H 17 E M 1 W3 R 3AB
127 H 17 X M 1 W3 R 3A
and
HE8C 117
or
HE8C 317
HE 807 EN 17 Y 0 A 3 000 3
HE 807 EN 17 Y 0 A 3 212 3
HE 807 EN 17 Y 0 A 3 213 3
127 H 17 X M 1 Y R 3A
127 H 17 K M 1 Y R 3A
127 H 17 S M 1 Y R 3A
127 H 17 X M 1 Y R 3A
127 H 17 X M 1 Y R 3A
127 H 17 X M 1 Y R 3A
and
and
HE8C 212
HE8C 213
or
or
HE8C 412
HE8C 413
HE 807 EN 17 Y 0 A 3 117 3
HE 807 FS 17 Y 0 A 3 000 3
HE 807 FS 17 Y 0 A 3 117 3
127 H 17 E M 1 Y R 3AB
127 H 17 XL F 1 Y N 3A
127 H 17 X M 1 Y R 3A
127 H 17 XL F 1 Y N 3A
127 H 17 XL F 1 Y N 3A
and
HE8C 117
or
HE8C 317
127 H 17 E
F 1 Y N 3A
and
HE8C 117
or
HE8C 317
HE 807 FS 17 Y 0 A 3 212 3
HE 807 FS 17 Y 0 A 3 213 3
127 H 17 K F 1 Y N 3AB
127 H 17 S F 1 Y N 3AB
127 H 17 XL F 1 Y N 3A
127 H 17 XL F 1 Y N 3A
and
and
HE8C 212
HE8C 213
or
or
HE8C 412
HE8C 413
HE 807 EN 17 Z 1 A 3 000 3
HE 807 EN 17 Z 1 A 3 212 3
HE 807 EN 17 Z 1 A 3 213 3
127 H 17 X M 1 ZC R 3A
127 H 17 K M 1 ZC R 3A
127 H 17 S M 1 ZC R 3A
127 H 17 X M 1 ZC R 3A
127 H 17 X M 1 ZC R 3A
127 H 17 X M 1 ZC R 3A
and
and
HE8C 212
HE8C 213
or
or
HE8C 412
HE8C 413
HE 807 EN 17 Z 1 A 3 117 3
HE 807 FS 17 Z 1 A 3 000 3
HE 807 FS 17 Z 1 A 3 117 3
127 H 17 E M 1 ZC R 3AB
127 H 17 XL F 1 Z N 3A
127 H 17 X M 1 ZC R 3A
127 H 17 XL F 1 Z N 3A
127 H 17 XL F 1 Z N 3A
and
HE8C 117
or
HE8C 317
127 H 17 E
F 1 Z N 3A
and
HE8C 117
or
HE8C 417
HE 807 FS 17 Z 1 A 3 212 3
HE 807 FS 17 Z 1 A 3 213 3
127 H 17 K F 1 Z N 3AB
127 H 17 S F 1 Z N 3AB
127 H 17 XL F 1 Z N 3A
127 H 17 XL F 1 Z N 3A
and
and
HE8C 212
HE8C 213
or
or
HE8C 412
HE8C 413
SYMETRICAL ARRANGEMENTS
HE 807 FB 17 Y 1 A 6 000 3
HE 807 FB 17 Y 1 A 6 101 3
HE 807 FB 17 Y 1 A 6 102 3
HE 807 FB 17 Y 1 A 6 103 3
HE 807 EB 17 Y 1 A 6 206 3
HE 807 EB 17 Y 1 A 6 208 3
HE 807 EB 17 Y 1 A 6 000 3
127 H 17 XL F 1 YC N 6A
127 H 17 A F 1 YC N 6A
127 H 17 PA F 1 YC N 6A
127 H 17 D F 1 YC N 6A
127 H 17 IE F 1 YC N 6A
127 H 17 KE F 1 YC N 6A
127 H 17 X F 1 YC N 6A
127 H 17 XL F 1 YC N 6A
127 H 17 XL F 1 YC N 6A
127 H 17 XL F 1 YC N 6A
127 H 17 XL F 1 YC N 6A
127 H 17 X F 1 YC N 6A
127 H 17 X F 1 YC N 6A
127 H 17 X F 1 YC N 6A
and
and
and
and
and
HE8C 101
HE8C 102
HE8C 103
HE8C 206
HE8C 208
or
or
or
or
or
HE8C 301
HE8C 302
HE8C 303
HE8C 406
HE8C 408
HE 807 FP 17 Y 1 A 6 101 3
HE 807 FP 17 Y 1 A 6 000 3
HE 807 EP 17 Y 1 A 6 208 3
127 H 17 A M 1 YC R 6A
127 H 17 XL M 1 YC R 6A
127 H 17 KE M 1 YC R 6A
127 H 17 XL M 1 YC R 6A
127 H 17 XL M 1 YC R 6A
127 H 17 X M 1 YC R 6A
and
and
HE8C 101
HE8C 208
or
or
HE8C 301
HE8C 408
HE 807 ES 17 W 0 A 6 000 2
HE 807 FS 17 W 0 A 6 117 2
HE 807 FS 17 W 0 A 6 000 2
HE 807 ES 17 W 0 A 6 212 2
127 H 17 X F 1 W3 N 6A
127 H 17 E F 1 W3 N 6A
127 H 17 XL F 1 W3 N 6A
127 H 17 K F 1 W3 N 6A
127 H 17 X F 1 W3 N 6A
127 H 17 XL F 1 W3 N 6A
127 H 17 XL F 1 W3 N 6A
127 H 17 X F 1 W3 N 6A
and
and
HE8C 117
HE8C 212
or
or
HE8C 317
HE8C 412
HE 807 EN 17 W 0 A 6 000 2
HE 807 FN 17 W 0 A 6 117 2
HE 807 FN 17 W 0 A 6 000 2
HE 807 EN 17 W 0 A 6 212 2
127 H 17 X M 1 W3 R 6A
127 H 17 E M 1 W3 R 6A
127 H 17 XL M 1 W3 R 6A
127 H 17 K M 1 W3 R 6A
127 H 17 X M 1 W3 R 6A
127 H 17 XL M 1 W3 R 6A
127 H 17 XL M 1 W3 R 6A
127 H 17 X M 1 W3 R 6A
and
and
HE8C 117
HE8C 212
or
or
HE8C 317
HE8C 412
HE 807 ES 17 Y 0 A 6 000 3
HE 807 FS 17 Y 0 A 6 117 3
HE 807 FS 17 Y 0 A 6 000 3
HE 807 FS 17 Y 0 A 6 119 3
HE 807 ES 17 Y 0 A 6 212 3
127 H 17 X F 1 Y N 6A
127 H 17 X F 1 Y N 6A
127 H 17 XL F 1 Y N 6A
127 H 17 XL F 1 Y N 6A
127 H 17 XL F 1 Y N 6A
127 H 17 X F 1 Y N 6A
127 H 17 E
F
1 Y N 6A
and
HE8C 117
or
HE8C 317
127 H 17 XL F 1 Y N 6A
127 H 17 EF F 1 Y N 6A
127 H 17 K F 1 Y N 6A
and
and
HE8C 119
HE8C 212
or
or
HE8C 319
HE8C 412
HE 807 EN 17 Y 0 A 6 000 3
HE 807 FN 17 Y 0 A 6 117 3
HE 807 FN 17 Y 0 A 6 000 3
HE 807 EN 17 Y 0 A 6 212 3
127 H 17 X M 1 Y R 6A
127 H 17 E M 1 Y R 6A
127 H 17 XL M 1 Y R 6A
127 H 17 K M 1 Y R 6A
127 H 17 X M 1 Y R 6A
127 H 17 XL M 1 Y R 6A
127 H 17 XL M 1 Y R 6A
127 H 17 X M 1 Y R 6A
and
and
HE8C 117
HE8C 212
or
or
HE8C 317
HE8C 412
HE 807 ES 17 Z 1 A 6 000 3
HE 807 FS 17 Z 1 A 6 117 3
HE 807 FS 17 Z 1 A 6 000 3
HE 807 ES 17 Z 1 A 6 212 3
HE 807 ES 17 Z 1 A 6 213 3
127 H 17 X F 1 Z N 6A
127 H 17 X F 1 Z N 6A
127 H 17 XL F 1 Z N 6A
127 H 17 XL F 1 Z N 6A
127 H 17 X F 1 Z N 6A
127 H 17 X F 1 Z N 6A
127 H 17 E
F
1 Z N 6A
and
HE8C 117
or
HE8C 317
127 H 17 XL F 1 Z N 6A
127 H 17 K F 1 Z N 6A
127 H 17 S F 1 Z N 6A
and
and
HE8C 212
HE8C 213
or
or
HE8C 412
HE8C 413
HE 807 EN 17 Z 1 A 6 000 3
HE 807 FN 17 Z 1 A 6 117 3
HE 807 FN 17 Z 1 A 6 000 3
HE 807 EN 17 Z 1 A 6 212 3
HE 807 EN 17 Z 1 A 6 213 3
ES 17-29-41-53 ONLY ON S1
HE 807 ES 17 S1 1 A 6 000 2
HE 807 FS 17 S1 1 A 6 117 2
HE 807 FS 17 S1 1 A 6 000 2
HE 807 ES 17 S1 1 A 6 212 2
HE 807 ES 17 S1 1 A 6 213 2
ES 17-29-41-53 ONLY ON S2
HE 807 EN 17 S2 1 A 6 000 2
HE 807 FN 17 S2 1 A 6 117 2
HE 807 FN 17 S2 1 A 6 000 2
HE 807 EN 17 S2 1 A 6 212 2
HE 807 EN 17 S2 1 A 6 213 2
127 H 17 X M 1 ZC R 6A
127 H 17 E M 1 ZC R 6A
127 H 17 XL M 1 ZC R 6A
127 H 17 K M 1 ZC R 6A
127 H 17 S M 1 ZC R 6A
127 H 17 X M 1 ZC R 6A
127 H 17 XL M 1 ZC R 6A
127 H 17 XL M 1 ZC R 6A
127 H 17 X M 1 ZC R 6A
127 H 17 X M 1 ZC R 6A
and
HE8C 117
or
HE8C 317
and
and
HE8C 212
HE8C 213
or
or
HE8C 412
HE8C 413
127 H 17 X F 1 X1 N 6A
127 H 17 X F 1 X1 N 6A
127 H 17 XL F 1 X1 N 6A
127 H 17 XL F 1 X1 N 6A
127 H 17 X F 1 X1 N 6A
127 H 17 X F 1 X1 N 6A
127 H 17 E
F
1 X1 N 6A
and
HE8C 117
or
HE8C 317
22
127 H 17 XL F 1 X1 N 6A
127 H 17 K F 1 X1 N 6A
127 H 17 S F 1 X1 N 6A
and
and
HE8C 212
HE8C 213
or
or
HE8C 412
HE8C 413
127 H 17 X M 1 X R 6A
127 H 17 E M 1 X R 6A
127 H 17 XL M 1 X R 6A
127 H 17 K M 1 X R 6A
127 H 17 S M 1 X R 6A
127 H 17 X M 1 X R 6A
127 H 17 XL M 1 X R 6A
127 H 17 XL M 1 X R 6A
127 H 17 X M 1 X R 6A
127 H 17 X M 1 X R 6A
and
HE8C 117
or
HE8C 317
and
and
HE8C 212
HE8C 213
or
or
HE8C 412
HE8C 413
Cross references chart HE 807 / 127 H
Connectors with 3 fitting locations (72,84,96 and 144 contacts)
HE 807
Amphenol
P/N
Amphenol P/N
without fitting
and
Brass fittings
or
Stainless steel fittings
2 extremity + 1 central
references
2 extremity + 1 central
HE8C…
HE8C…
HE8C…
HE8C…
ASYMETRICAL ARRANGEMENTS
HE 807 FB 84 Y 1 A 3 000 3 127 H 84 XL F 1 YC N 3A
HE 807 FB 84 Y 1 A 3 101 3 127 H 84 A F 1 YC N 3A
HE 807 FB 84 Y 1 A 3 102 3 127 H 84 PA F 1 YC N 3A
HE 807 FB 84 Y 1 A 3 103 3 127 H 84 D F 1 YC N 3A
127 H 84 XL F 1 YC N 3A
127 H 84 XL F 1 YC N 3A
127 H 84 XL F 1 YC N 3A
127 H 84 XL F 1 YC N 3A
and
and
and
HE8C 101
HE8C 102
HE8C 103
and
and
and
HE8C 102
HE8C 102
HE8C 102
or
or
or
HE8C 301
HE8C 302
HE8C 303
and HE8C 302
and HE8C 302
and HE8C 302
HE 807 FB 84 Y 1 A 3 206 3 127 H 84 IE F 1 YC N 3AB 127 H 84 XL F 1 YC N 3AB
HE 807 FB 84 Y 1 A 3 208 3 127 H 84 KE F 1 YC N 3AB 127 H 84 XL F 1 YC N 3AB
and
and
HE8C 206
HE8C 208
and
and
HE8C 206
HE8C 208
or
or
HE8C 406
HE8C 408
and HE8C 406
and HE8C 408
HE 807 EP 84 Y 1 A 3 000 3 127 H 84 X M 1 YC R 3A
HE 807 EP 84 Y 1 A 3 101 3 127 H 84 A M 1 YC R 3AB
127 H 84 X M 1 YC R 3A
127 H 84 X M 1 YC R 3A
and
and
HE8C 101
HE8C 212
and
and
HE8C 102
HE8C 229
or
or
HE8C 301
HE8C 412
and HE8C 302
and HE8C 429
HE 807 FS 84 W 1 B 3 000 2 127 H 84 XL F 1 W3 N 3A
HE 807 FS 84 W 1 B 3 212 2 127 H 84 K F 1 W3 N 3AB 127 H 84 XL F 1 W3 N 3A
127 H 84 XL F 1 W3 N 3A
HE 807 EN 84 W 0 B 3 000 2 127 H 84 X M 1 W3 R 3A
HE 807 EN 84 W 0 B 3 212 2 127 H 84 K M 1 W3 R 3A
127 H 84 X M 1 W3 N 3A
127 H 84 X M 1 W3 R 3A
and
and
HE8C 212
HE8C 117
and
and
HE8C 229
HE8C 129
or
or
HE8C 412
HE8C 317
and HE8C 429
and HE8C 329
HE 807 EN 84 W 0 B 3 117 2 127 H 84 E M 1 W3 R 3AB
127 H 84 X M 1 W3 R 3A
HE 807 EN 84 Y 0 A 3 000 3 127 H 84 X M 1 Y R 3A
HE 807 EN 84 Y 0 A 3 212 3 127 H 84 K M 1 Y R 3A
127 H 84 X M 1 Y R 3A
127 H 84 X M 1 Y R 3A
and
and
HE8C 212
HE8C 117
and
and
HE8C 229
HE8C 129
or
or
HE8C 412
HE8C 317
and HE8C 429
and HE8C 329
HE 807 EN 84 Y 0 A 3 117 3 127 H 84 E M 1 Y R 3AB 127 H 84 X M 1 Y R 3A
HE 807 FS 84 Y 0 A 3 000 3 127 H 84 XL F 1 Y N 3A 127 H 84 XL F 1 Y N 3A
HE 807 FS 84 Y 0 A 3 212 3 127 H 84 K F 1 Y N 3AB 127 H 84 XL F 1 Y N 3A
and
HE8C 212
and
HE8C 229
or
HE8C 412
and HE8C 429
HE 807 EN 84 Z 1 B 3 000 3 127 H 84 X M 1 ZC R 3A
HE 807 EN 84 Z 1 B 3 212 3 127 H 84 K M 1 ZC R 3A
HE 807 EN 84 Z 1 B 3 119 3 127 H 84 EF M 1 ZC R 3AB
127 H 84 X M 1 ZC R 3A
127 H 84 X M 1 ZC R 3A
127 H 84 X M 1 ZC R 3A
and
and
HE8C 212
HE8C 119
and
and
HE8C 229
HE8C 129
or
or
HE8C 412
HE8C 319
and HE8C 429
and HE8C 329
HE 807 FS 84 Z 1 B 3 000 3 127 H 84 XL F 1 Z N 3A
127 H 84 XL F 1 Z N 3A
HE 807 FS 84 Z 1 B 3 212 3 127 H 84 K F 1 Z N 3AB 127 H 84 XL F 1 Z N 3A
and
HE8C 212
and
HE8C 229
or
HE8C 412
and HE8C 429
SYMETRICAL ARRANGEMENTS
HE 807 FB 56 Y 1 A 10 000 3 127 H 56 XL F 1 YC N 10A 127 H 56 XL F 1 YC N 10A
HE 807 FB 56 Y 1 A 10 101 3 127 H 56 A F 1 YC N 10A 127 H 56 XL F 1 YC N 10A
and
and
and
HE8C 101
HE8C 101
HE8C 212
and
and
and
HE8C 102
HE8C 102
HE8C 229
or
or
or
HE8C 301
HE8C 301
HE8C 412
and HE8C 302
and HE8C 302
and HE8C 429
HE 807 FP 56 Y 1 A 10 000 3 127 H 56 XL M 1 YC R 10A 127 H 56 XL M 1 YC R 10A
HE 807 FP 56 Y 1 A 10 101 3 127 H 56 X M 1 YC R 10A 127 H 56 XL M 1 YC R 10A
HE 807 ES 56 W 0 B 10 000 2 127 H 56 X F 1 W3 N 10A
HE 807 ES 56 W 0 B 10 212 2 127 H 56 K F 1 W3 N 10A
127 H 56 X F 1 W3 N 10A
127 H 56 X F 1 W3 N 10A
HE 807 EN 56 W 0 B 10 000 2 127 H 56 X M 1 W3 R 10A
HE 807 FN 56 W 0 B 10 000 2 127 H 56 XL M 1 W3 R 10A
127 H 56 X M 1 W3 R 10A
127 H 56 XL M 1 W3 R 10A
HE 807 ES 56 Y 0 A 10 000 3 127 H 56 X F 1 Y N 10A 127 H 56 X F 1 Y N 10A
HE 807 FS 56 Y 0 A 10 117 3 127 H 56 E F 1 Y N 10A
HE 807 ES 56 Y 0 A 10 212 3 127 H 56 K F 1 Y N 10A
127 H 56 XL F 1 Y N 10A
127 H 56 X F 1 Y N 10A
and
and
HE8C 117
HE8C 212
and
and
HE8C 129
HE8C 229
or
or
HE8C 317
HE8C 412
and HE8C 329
and HE8C 429
HE 807 EN 56 Y 0 A 10 000 3 127 H 56 X M 1 Y R 10A 127 H 56 X M 1 Y R 10A
HE 807 EN 56 Y 0 A 10 212 3 127 H 56 K M 1 Y R 10A 127 H 56 X M 1 Y R 10A
and
and
HE8C 212
HE8C 213
and
and
HE8C 229
HE8C 229
or
or
HE8C 412
HE8C 413
and HE8C 429
and HE8C 429
HE 807 ES 56 Z 1 B 10 000 3 127 H 56 X F 1 Z N 10A
HE 807 ES 56 Z 1 B 10 213 3 127 H 56 S F 1 Z N 10A
127 H 56 X F 1 Z N 10A
127 H 56 X F 1 Z N 10A
HE 807 EN 56 Z 1 B 10 000 3 127 H 56 X M 1 ZC R 10A 127 H 56 M 1 ZC R 10A
HE 807 FN 56 Z 1 B 10 000 3 127 H 56 XL M 1 ZC R 10A
127 H 56 XL M 1 ZC R 10A
72 + 6A ONLY ON S1
HE 807 ES 72 S11 A 6 000 2 127 H 72 X F 1 X1 N 6A
HE 807 FS 72 S11 A 6 000 2 127 H 72 XL F 1 X1 N 6A
72 + 6A ONLY ON S2
127 H 72 X F 1 X1 N 6A
127 H 72 XL F 1 X1 N 6A
HE 807 EN 72 S21 A 6 000 2 127 H 72 X M 1 X R 6A
HE 807 FN 72 S21 A 6 000 2 127 H 72 XL M 1 X R 6A
127 H 72 X M 1 X R 6A
127 H 72 XL M 1 X R 6A
23
Table of contents
..............................................................................................................
DESCRIPTION & CHARACTERISTICS
1
2
3
3
.....................................................................................................................................................
ARRANGEMENTS
CONTACTS & FITTINGS
........................................................................................................................................
TOOLING
FITTINGS
......................................................................................................................................................................
Plugs – Male fittings
Receptacles – Female fittings
4
5
.............................................................................................................................................
............................................................................................................................
CONTACTS FOR HE 807 / 127 H CONNECTORS
Power contacts
Coaxial contacts
Optical termini
6
7
8
......................................................................................................................................................
....................................................................................................................................................
.......................................................................................................................................................
PANEL & PCB DRILLING
For HE 801- HE 804 / 127 connectors
9
...........................................................................................................
For HE 807 / 127 H connectors
10
.....................................................................................................................
ACCESSORIES FOR HE 804 PLUGS
Hoods for HE 804 plugs
12
13
...................................................................................................................................
Locking systems for HE 804 plugs
.................................................................................................................
CONNECTORS ORDERING INFORMATION
HE 801 – HE 804 3-row female plugs
HE 801 – HE 804 3-row male receptacles
HE 801 – HE 804 2-row female plugs
HE 801 – HE 804 2-row male receptacles
15
15
16
16
17
17
18
19
19
.....................................................................................................
..............................................................................................
.....................................................................................................
..............................................................................................
HE 801 – HE 804 2-row male plugs
.........................................................................................................
HE 801 – HE 804 2-row female receptacles
..........................................................................................
HE 807 male or female plugs
.........................................................................................................................
HE 807 male or female receptacles
...............................................................................................................
Fittings
...................................................................................................................................................................
CROSS REFERENCES
HE 801 / 127
HE 804 / 127
HE 807 / 127 H
20
21
22
.......................................................................................................................................................
.......................................................................................................................................................
...................................................................................................................................................
Amphenol
Do not hesitate to contact us for further information
Amphenol Socapex
Mil/Aero & Industrial Business Unit
948, Promenade de l’Arve - BP 29
F - 74311 Thyez Cedex
Tel.: +33 (0) 4 50 89 28 00 - Fax: +33 (0) 4 50 96 19 41
http://www.amphenol.com
Sales office in Paris
Tel.: +33 (0) 1 49 05 30 00 - Fax: +33 (0) 1 49 05 30 43
相关型号:
12717RM-W3
Board Connector, 17 Contact(s), 2 Row(s), Male, Straight, Wire Wrap Terminal, Plug
AMPHENOL
12717RM-Y-R
Board Connector, 17 Contact(s), 2 Row(s), Male, Straight, Solder Terminal, Plug,
AMPHENOL
12717RM-ZC-R
Board Connector, 17 Contact(s), 2 Row(s), Male, Straight, Solder Terminal, Plug
AMPHENOL
12717RSM-W3
Board Connector, 17 Contact(s), 2 Row(s), Male, Straight, Wire Wrap Terminal, Plug
AMPHENOL
12717RSM-W3-R
Board Connector, 17 Contact(s), 2 Row(s), Male, Straight, Wire Wrap Terminal, Plug
AMPHENOL
12717RSM-Y
Board Connector, 17 Contact(s), 2 Row(s), Male, Straight, Solder Terminal, Plug,
AMPHENOL
12717RSM-Y-R
Board Connector, 17 Contact(s), 2 Row(s), Male, Straight, Solder Terminal, Plug,
AMPHENOL
12717RSM-ZC
Board Connector, 17 Contact(s), 2 Row(s), Male, Straight, Solder Terminal, Plug
AMPHENOL
12717RSM-ZC-R
Board Connector, 17 Contact(s), 2 Row(s), Male, Straight, Solder Terminal, Plug
AMPHENOL
©2020 ICPDF网 联系我们和版权申明