NPH-8 [AMPHENOL]
Solid state, high reliability;型号: | NPH-8 |
厂家: | Amphenol |
描述: | Solid state, high reliability |
文件: | 总4页 (文件大小:111K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
NPH Series
Solid State Low
Pressure Sensors
Applications
Features
•ꢀ Process control, P-to-I converters
•ꢀ Pneumatic control systems
•ꢀ HVAC controls
•ꢀ Solid state, high reliability
•ꢀ Standard TO-8 package suitable for PC board
mount
•ꢀ Low cost , small size
•ꢀ Biomedical: Infusion pumps,
sphygmomanometers, respirators
•ꢀ Available in gauge, absolute, and differential
pressure versions
•ꢀ Aerospace: Altimeters, barometers, cabin
pressure sensors
•ꢀ Media compatible with non-corrosive gases and
dry air
•ꢀ Computer peripherals
•ꢀ Thermal accuracy FSO 0.5% typical
•ꢀ Overpressure capability to five times maximum
rated pressure
•ꢀ Three standard ranges: 0 to 10 inH2O (0 to 25
mbar), 0 to 1 psi (0 to 0.06 bar), and 0 to 5 psi (0
to 0.34 bar)
•ꢀ Nonlinearity 0.05% FSO typical
•ꢀ Standard 3/16 in OD pressure port
•ꢀ Ceramic substrate with temperature
compensation resistors
Amphenol
Advanced Sensors
NPH Series Specifications
Parameter
General
Value
Units
Notes
Description
Pressure Range
0 to 10
inH2O (0 to 25 mbar) 0 to 2.5
kPa
An integrated circuit silicon sensor chip is housed
in a standard TO-8 electrical package that is printed
circuit board mountable.
0 to 1
0 to 5
psi
psi
(0 to 7 bar) 0 to 7 kPa
(0 to 0.34 bar) 0 to 30
kPa
The latest techniques in micromachining have been
used to ion-implant piezoresistive strain gauges into
a wheatstone bridge configuration that is integrally
formed on a micromachined silicon diaphragm.
As with all NovaSensor silicon sensors, the NPH
Series employs SenStable® processing technology,
providing excellent output stability. Constant
current excitation to the sensor produces a voltage
output that is linearly proportional to the input
pressure.
Maximum Pressure
5x
rated pressure (10)
Electrical @ 77°F (25°C) Unless Otherwise Stated
Input Excitation
Insulation Resistance
Input Impedance
Output Impedance
Bridge Impedance
Environmental
Temperature Range
Operating(9)
1.5
mA
MΩ
Ω
2 mA maximum
@ 50 VDC
±25%
100
3200
5000
5000
Ω
±20%
Ω
±20%
–40 to 257 °F
(-40°C to 125°C)
(0°C to 70°C)
Compensated
Vibration
32 to 158
10
°F
The user can provide standard signal conditioning
circuitry to amplify the 100 mV output signal. The
sensor is compatible with most non-corrosive gases
and dry air.
gRMS 20 to 2000Hz
Shock
100
g
11 milliseconds
Life (Dynamic Pressure
Cycle)
1 x 106
cycles
Mechanical (1)
Weight
A laser-trimmed, thick-film resistor network on a
hybrid ceramic substrate provides temperature
compensation.
<0.2
oz
(<5 g)
Media Compatibility
Wetted Materials
Top Port
Non-corrosive gases and clean, dry air
Nickel, gold plated Kovar, silicone gel, gold
wire, RTV, silicon and glass.
Gold plated Kovar, silicon, glass and RTV (9)
Bottom Port
Parameter
Min. Typical Max.
Min.
-4
Typical
7 & 30
kPa
Max. Units
Notes
2.5
kPa
Performance Parameters(7), Compensated(1)
Offset
-8
2
8
2
4
mV
Full Scale (FS) Output
2.5 kPa
7 kPa
25
50
90
mV
2
2
2
3
50
75
150
125
0.25
0.2
mV
30 kPa
Linearity
75
100
0.05
0.05
mV
–1.0
-0.2
0.1
1.0
0.2
–0.25
-0.2
%FSO
%FSO
Hysteresis &
Repeatability
0.05
NPH Series schematic diagram
Thermal
Accuracy of
Offset
-3
0.5
–1
3
-2
0.5
2
%FSO
4
Accuracy of FSO
–3
3
-1.5
–0.5
-0.5
0.2
1.5
0.5
%FSO
%FSO
4
5
Thermal
–0.75 0.5
0.75
Hysteresis
Short-Term
Stability of Offset
5
5
5
5
µV/V
µV/V
6, 11
6, 11
Short-Term
Stability of FSO
1. Performance with offset, thermal accuracy of offset, and thermal accuracy of FSO
compensation resistors.
2. FSO with 1.5mA input excitation.
3. Best fit straight line.
4. 32°F to 158°F (0°C to 70°C) with reference to 77°F (25°C)
5. 32°F to 158°F (0°C to 70°C), by design
6. Normalized offset/bridge voltage —100 hrs, typical value, not tested in production.
7. All values measured at 77°F (25°C) and at 1.5 mA, unless otherwise noted.
8. Reduced performance outside compensation range.
9. Backside differential tube is nickel or Kovar.
10. Top side pressure.
11. Typical specifications are for reference only; absolute values may vary.
NPH Series Specifications
NPH Series package diagram
Ordering Information
Theꢀcodeꢀnumberꢀtoꢀbeꢀorderedꢀmayꢀbeꢀspecifiedꢀasꢀfollows:
NPH
Code
Package Configuration
8
TO-8
Code
002.5
007
Pressure Range (kPa)
2.5 kPa; 10 inH2O
7 kPa; 1 psi
030
30 kPa; 4.35 psi
Code
Pressure
A
G
D
Absolute (30 kPa only)
Gauge
Differential
Code
H
Compensation
Hybrid substrate
NPH - _____ - _____ - _____ - _____ Typical model number
www.amphenol-sensors.com
©ꢀ2014ꢀAmphenolꢀCorporation.ꢀAllꢀRightsꢀReserved.ꢀSpecificationsꢀareꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.ꢀ
Other company names and product names used in this document are the registered trademarks or
trademarks of their respective owners.
Amphenol
Advanced Sensors
AAS-920-275B-08/2014
相关型号:
©2020 ICPDF网 联系我们和版权申明