SLRKEM537S [AMPHENOL]
Circular Connector;型号: | SLRKEM537S |
厂家: | Amphenol |
描述: | Circular Connector |
文件: | 总4页 (文件大小:206K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SLR
Reinforced version of the SLX
Strong points:
• High shock resistance (metallic shells).
• High vibration resistance (one thread lock, low slope).
• High salt spray and chemical agents resistance (specific corrosion resistant
shells plating).
SLR series connectors are derived
from the standard SLX and have the
particulary to be well adapted to
applications in harsh environments
(Shocks, Vibrations, Humidity) like
shelters, off shore or buiding sites
activities
• IP 67, when mated due to receptacle and panel gaskets as well as one piece
backshell with cable clamp and sealing gland backshell.
• Metallic protective caps for plug and receptacle with seal.
• Working temperature: -55°C/+125°C.
• 5 positionning keys for Plug / Receptacle.
Coding by user allows a diminution of
the number of references to manage.
• Coding by the user: 12 coding possibilities (from A to M) by insert rotation.
(without any specific tool).
• Crimp removable gold plated machined contacts
• Closed entry female contacts.
• 3 arrangements: 55 size 16 contacts, 37 size 12 contacts, 37 size 16 contacts.
For other arrangement, please consult us.
SLR : Harsh
environment just
make it stronger !
General characteristics:
CHARACTERISTIC
VALUE
NORME
Watertightness
Physical shock
IP67 connected
IK06 / 1.5 kg mass dropped from a 40 cm NFEN 50 102
height
NFEN 60 529
Fall test
Vibrations
Fall Height: 1 meter
10 to 60 Hz,
NFC 93 400 - Test 7b
• Shelters
amplitude 0.075 mm
60 to 100 Hz,
speed 25.4 mm/sec
100 to 600 Hz,
acceleration 5G
• Power
no cut ≥ 1µs
NFC 93 400 - Test 6b
NFC 93 400 - Test 17c
• Check-Control
• Building sites
• Off shore
Cable clamp tensile strength 40 kg in axis
Acceptable cables
diameter:
20 to 35 mm
Humidity
Working temperature
Durability
Proof voltage
Insert resistance
Contact resistance
21 days - 43°C to humidity 98%
-55°C/+125°C
≥ 100 mating cycles
≥ 3000 V
≥ 100 MΩ
≤ 2 mΩ
NFC 93 400 - Test 11c
NFC 93 400 - Test 11d
NFC 93 400 - Test 9a
NFC 93 400 - Test 4a
NFC 93400 - Test 3a
NFC 93400 - Test 2a-2b
Note: Reference document NFF 61-030
UL 1977 approved
Available arrangements:
Pin connector front face view, A coding.
2
6
1
4
1
1
3
3
5
7
8
9
4
4
9
9
5
15
11
13
22
10
38
16
44
10
14
23
10
23
12
17
32
22
37
15
16
17
18
22
28
25
29
16
19
20
35
23
31
26
24
25
27
30
28
29
29
33
32
33
50
31
45
34
37
34
51
55
37
35
537S
37 size 16 contacts
537D
37 size 12 contacts
555
55 size 16 contacts
Dimensions of the connectors:
• Receptacle:
38,7
Possibility to mount the
receptacle at the front
or the rear of the panel
by inverting the panel
gasket.
72,6 Twice
55,4 Twice
30,7
T16 or T12 Pin contact
12.4 to 13.5
ø 90
3
• Positionning of
socket contact
1
9
4
16
22
31
10
17
23
25
29
32
38
45
51
37
44
50
53
T12 contact: 12.6 to 13.6
T16 contact: 13.1 to 14.1
12,5
4 places ø 5,5
20,5
137
ø 5,2
APPROXIMATE
174 MAXI
52
T12 Socket contact: 20.5 to 21.5
T16 Socket contact: 20 to 21
ø 80
Ø 20 to 35 cables
• Plug:
3
1
9
4
16
44
10
38
22
31
17
23
29
25
37
32
50
45
55
51
• Positionning
of pin contact
ø 56
ø 48
T16 or T12 contact
20.7 to 21.8
273
APPROXIMATE
Dimensions of connectors with protective caps:
49
41
185 MAXI
Contacts:
2 contact types: size 16 and size 12
Contact size
16
12
Nominal current
13 A
25 A
Contact resistance
≤ 2 mΩ
≥ 40 N
800660
800664
≤ 2 mΩ
≥ 45 N
21713
21728
Contact retention in the insert
Part-number for one pin contact*
Part-number for one socket contact*
* Minimum order quantity: 100 contacts
Permissible wire:
Crimp Barrel
Pin
Contact
(mm)
3
Wire
Section
mm2
Diameter over
conductor (mm)
Maxi Diameter
Over Sleeving
Contact
Size
Inside Diameter
Depth
(mm)
7.5
Gauge
(AWG)
14→12
20→14
(mm)
2.5
1.95
mini
maxi
3.3
mini
1.7
1
maxi
2.45
1.9
(mm)
4.2
2.8
12
16
1.8
6.4
1.6
0.6*
1.91
2
* The use of a 800629 reducing sleeve is necessary for cable section less than 0.60 mm for size 16 contacts
Acceptable cable diameter:
20 to 35 mm.
Cabling tools:
- Crimping pliers 809857 (M22520/1-01)
- Controlling jauge 809907 (M22520/3-1)
- Locator 21770 (TH 397 Daniels)
Screwdriver type
(Set the selector in position 4)
Contacts
Insertion Tool
Removal Tool
Screwdriver type
141900 (metal)
141900 (metal)
48680 (plastic)
48680 (plastic)
Pliers type
809735
809735
809734
809734
Size 12: Pin
Size 12: Socket
Size 16: Pin
21746
21745
809731
809732
Size 16: Socket
Pliers type
Cabling process:
• Crimping process
Place the locator in the pliers.
Choose the selector number on the locator according to the contact size to crimp.
Strip the wire end (7.5mm for size 12 contact / 6mm for size 16 contact)
Insert the wire in the contact crimp barrel of and check through the inspection hole of the contact that wire
is wellplaced.
Place the contact with the wire into the pliers until the stop.
Completely close the tool and after, let it open itself.
Visually check if crimping is correct and by the inspection hole of the contact if the wire is well-placed in the
crimp barrel.
• Contact insertion
Always put insert into shell before beginning the contact insertion.
Insert the wired contact in the groove of the tool, taking care that the extremity of the tool touches the
shoulder of the contact.
Insert the contact in its cavity from wiring side and steadily push the tool along the axis of the cavity until
the contact locks home.
Carefully withdraw the tool , applying a forward pressure on the wire.
Pull on the wire to check that the contact is correctly locked.
• Contact removal
Insert the tool from the mating side and push it along the contact axis until contact unlocks.
Pull the contact out from the rear of the connector.
IMPORTANT: If you do not use some cavities, always insert a contact to ensure the contact retention and the
non-mating for the case when the coding is different between the plug and the receptacle.
For good contact retention, do not remove it more than three times.
How to order:
Connectors
SLR
F
F
DR
5
37D LC
Blank: Connector without protective cap
K: Connector and protective cap Kit
F: Plug
E: Receptacle
F: Socket contact insert
M: Pin contact insert
DR: Straight Backshell (Plug only)
Blank: Receptacle
Shell size:
5 for 50
Arrangement:
37S: 37 size 16 contacts
37D: 37 size 12 contacts
55: 55 size 16 contacts
LC: Connector sold without contact. Contacts to be ordered separately (see page 3)
Blank: Connector sold with contacts.
Note: Inserts are not assembled into shells so that the user chooses among the 12 coding possibilities.
Protective caps
5
SLR B
F
F: Plug protective cap
E: Receptacle protective cap
Shell size: 50
Amphenol
Do not hesitate to contact us for further information
Amphenol Socapex
Mil/Aero & Industrial Business Unit
948, Promenade de l’Arve - BP 29
F - 74311 Thyez Cedex
Tel.: +33 (0) 4 50 89 28 00 - Fax: +33 (0) 4 50 96 19 41
http://www.amphenol.com
Sales office
Tel.: +33 (0) 1 49 05 30 00 - Fax: +33 (0) 1 49 05 30 43
相关型号:
SLRM2102000DDACS
Array/Network Resistor, Isolated, Thin Film, 0.1W, 10200ohm, 0.5% +/-Tol, -10,10ppm/Cel, 1021,
VISHAY
SLRM2102001ACABG
Array/Network Resistor, Isolated, Thin Film, 0.1W, 102000ohm, 0.05% +/-Tol, -10,10ppm/Cel, 1021,
VISHAY
SLRM2104001BDBFG
Array/Network Resistor, Isolated, Thin Film, 0.1W, 104000ohm, 0.1% +/-Tol, -25,25ppm/Cel, 1021,
VISHAY
SLRM2106000CBDFG
Array/Network Resistor, Isolated, Thin Film, 0.1W, 10600ohm, 0.2% +/-Tol, -50,50ppm/Cel, 1021,
VISHAY
©2020 ICPDF网 联系我们和版权申明