X2572-18 [AMPHENOL]

RF Mesh Networking technology provides reliable real time process data. Uses global 2.4 GHz RF frequencies;
X2572-18
型号: X2572-18
厂家: Amphenol    Amphenol
描述:

RF Mesh Networking technology provides reliable real time process data. Uses global 2.4 GHz RF frequencies

文件: 总8页 (文件大小:444K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Kaye RF ValProbe®  
RF Thermal Validation  
System  
LINK  
POWER  
STATUS  
®
Kaye RFValProbe  
The Kaye RF ValProbe integrates breakthrough  
RF Mesh technology with well-established thermal  
validation in situ loggers.  
Features  
•ꢀ RFꢀMesh Networking technology provides reliable  
real time process data. Uses global 2.4 GHz RF  
frequencies  
The Kaye RF ValProbe system is intended for the  
validation and monitoring of environmental chambers  
and storage areas (i.e. stability chambers, freezers,  
refrigerators, warehouses, etc). The RF ValProbe  
system utilizes a 2.4 GHz RF Mesh network and  
multipleredundant data storage to provide ultra-  
reliable and robust communications and storage  
of critical validation data. Additional safeguards  
guarantee data integrity, storage and compliance with  
regulatory requirements.  
•ꢀ Providesꢀ100%ꢀdataꢀredundancyꢀinꢀbothꢀremoteꢀ  
logger and base station in addition highly reliable RF  
network.  
•ꢀ Greaterꢀthanꢀ1ꢀyearꢀbatteryꢀlifeꢀinꢀtypicalꢀuse,ꢀusingꢀ  
Standard AA Lithium batteries.  
•ꢀ Canꢀoperateꢀstand-aloneꢀorꢀwithꢀPCꢀconnectedꢀwithꢀ  
data stored in RF Base Station  
•ꢀ Intuitiveꢀstudyꢀset-upꢀandꢀextensiveꢀcalculationsꢀ  
simplify the validation and reporting process  
The RF ValProbe system is comprised of RF wireless  
loggers, a base station and software. The loggers  
provide high accuracy measurement of temperature,  
humidity, and any 4 to 20mA  
•ꢀ Best-in-classꢀdataꢀanalysisꢀtools,ꢀincludingꢀabilityꢀtoꢀ  
graph and report in cycles and groups  
or 0 to 10 V output.  
•ꢀ Reportꢀtoolꢀcanꢀprocessꢀandꢀcreateꢀmergedꢀreportsꢀ  
from RF ValProbe, ValProbe or Validator products  
RF ValProbe’s software enables support for  
2-Channel and 5-Channel RF Temperature loggers for  
Validation.  
•ꢀ Versionsꢀprovideꢀtemperatureꢀtoꢀ0.1°Cꢀaccuracy,ꢀ  
RHꢀtoꢀ2%ꢀRH,ꢀ4/20ꢀmA,0ꢀtoꢀ10ꢀVꢀandꢀdryꢀcontactꢀ  
switch inputs, 2-Channel and 5-Channel Temperature  
logger  
The software provides ease of use by incorporating  
features such as self-configuring of the mesh network  
and automatic data collection. Extensive graphing,  
reporting and calculation capabilities minimize data  
analysis and provide regulatory-compliant reports.  
•ꢀ Temperatureꢀandꢀpressureꢀaccuracyꢀmeetsꢀ  
requirements for ISO-17665, EN554 and EN285  
sterilization requirements.  
•ꢀ EasyꢀconnectionꢀtoꢀKayeꢀPressureꢀtransducerꢀwhichꢀ  
is designed for harsh environment applications such  
as steam sterilizers and SIP systems.  
It is used for simplified real time validation of Stability  
Chambers, Freezers, Warehouses and Steam in Place  
Application.  
•ꢀ Canꢀbeꢀdirectlyꢀconnectedꢀtoꢀ1.5ꢀinꢀtricloverꢀflangeꢀviaꢀ  
SmartGasket® or similar gasket design.  
Amphenol  
Advanced Sensors  
SmartMesh® Technology  
Mesh networking technology is proven in many harsh  
environment applications. Its implementation in  
the Kaye product line allows up to 100 nodes to be  
connected in a seamless, reliable and self forming  
mesh network. The mesh technology permits nodes  
to communicate with the base station and each  
other, correcting for weak RF links and automatically  
adjusting to dynamic RF environment, e.g. a forklift  
truck driving into a warehouse blocking a signal.  
Interference from WiFi and other existing industrial RF  
networks is removed due to the frequency hopping  
features. No special knowledge or expertise is required  
to install or operate the Kaye RF ValProbe.  
Secure Data  
There are multiple levels of transactional and data  
security built into the RF ValProbe system.  
1. Only Kaye RF ValProbe nodes are permitted to join  
a RF ValProbe network through the use of private  
keys and login registration information exchanged  
between the Base Station and RF ValProbe nodes at  
startup.  
2. All data transmitted on the network is protected  
using secure keys, preventing non-authorized base  
stations or nodes eavesdropping on the data or  
feeding nonauthorized data into the network.  
3. All data is timestamped, and identified by sending  
the logger’s serial number. All data and meta data  
associated with a qualification study is stored in a  
single secure, tamperproof file.  
RF Specifications & Certifications  
RF 2.4GHz SmartMesh® Technology Max number  
wirelessꢀnodes:ꢀ100ꢀRange:ꢀapproxꢀ300ꢀft/100mꢀfromꢀ  
one node to another Each node can act as a repeater  
RF Type Approval Certifications in: US, Canada, EU.  
Other countries in progress, please contact factory for  
up to date country list  
4. DoS (Denial of Service) attacks are prevented by  
Message Integrity Codes.  
Automatic Network Formation and  
Optimization  
Data Redundancy  
SmartMesh networks are self forming and self-  
optimizing Every node can discover neighbors,  
measure RF signal strength, acquire synchronization  
and frequency hopping information, and establish  
best paths and links with neighbors. This ability to  
dynamically reconfigure is dictated by RF connectivity  
and/orꢀnetworkꢀperformanceꢀrequirements.  
The RF SmartMesh Technology provides a very  
secure, reliable transmission; however there are  
circumstances where RF transmission is blocked, either  
by placement of a logger of some intermittent physical  
or radiofrequency blocking of the signal. The loggers  
store up to 10,000 samples per sensor permitting the  
operation as a data logger if RF communication is not  
possible, e.g. one logger placed in a warehouse exhaust  
HVAC duct. The logger will resume transmitting data  
once it is in RF communication with the base station or  
other logger.  
LINK  
POWER  
LINK  
POWER  
STATUS  
STATUS  
®
Kaye RF ValProbe  
®
Kaye RF ValProbe  
LINK  
POWER  
The base station provides data storage also, permitting  
the user to start a study then disconnect the PC.  
Data storage permits all data collected on all loggers  
to be stored in the base station until the PC is next  
connected.  
STATUS  
®
Kaye RF ValProbe  
LINK  
LINK  
POWER  
POWER  
STATUS  
STATS  
®
®
Kaye RF ValProbe  
Kaye RF  
ValProbe  
LINK  
POWER  
LINK  
POWER  
ST  
A
TUS  
STATUS  
®
®
Kaye RF ValProbe  
Kaye RF ValProbe  
LINK  
POWER  
blockage  
STATUS  
®
Kaye RF ValProbe  
*SmartMesh is a trademark of Dust Networks, Inc.  
2
Interference  
Real time graphing calculations  
The SmartMesh® technology combines frequency  
hopping with TDMA (Time Division Multiple Access). In  
addition the mesh protocol permits the system to learn  
about the RF environment and dynamically adjust the  
network parameters to best fit the current situation.  
Realꢀtimeꢀgraphingꢀprovidesꢀmin/max/avgꢀcalculationsꢀ  
for the RH and Temp parameters of all the loggers  
being plotted in the real time graph.  
Alarming  
The network provides an accurate time reference for  
the whole network, ensuring all loggers and the base  
station are time synchronized correctly. Each data  
sample is timestamped with this network time.  
User can set low and high alarms on the real time  
graph to see if any loggers have crossed the limits. The  
limits can also be labeled by the user.  
Auto Calibration/Verification  
RFꢀValProbeꢀSystemꢀenablesꢀautoꢀcalibration/  
verification for the users when using the RF loggers,  
Kaye IRTD, Kaye Temperature baths. This enables the  
user to select the set points and let the software run  
theꢀcalibration/verificationꢀincludingꢀloadingꢀofꢀoffsetsꢀ  
into the loggers automatically.  
Coexistence with Other RF Systems  
The software will control the Kaye drywells and read  
the reference temperature data from a connected  
Kaye IRTD permitting full automatic calibration with  
the Kaye calibration products. Providing that the  
users configure the communications port , access to  
automatic calibration will be permitted. Calibration is  
still permitted if either drywells or IRTD is not present,  
in which case either semi-automatic or manual mode  
calibration is used.  
The RF ValProbe complies with the IEEE 802.15.4, the  
preeminent RF sensor network standard. Features like  
frequency hopping, listen-before-you-talk and channel  
blacklisting prevents other RF networks being affected  
by the RF ValProbe.  
Software Features  
Independent Report Wizard  
Historical graphing  
Along with the RF ValProbe software, there is an  
additional software program called the “Kaye Report  
Wizard”. This report wizard permits the user to launch  
the “Create Reports” section independently of the  
Kaye product installed on the user’s PC. The “Create  
Reports” button of the standard software will continue  
to operate as in previous versions. The user can decide  
install the Report Wizard in a separate folder and use it  
to report on all 3 Kaye products: Validator, Valprobe or  
RF Valprobe.  
Once a study has been started, user can connect his  
PC anytime to the base station and retrieve all the data  
from the base station on the real time graph to view the  
data that has been logged by the loggers to that point.  
This will enable viewing historical data without having  
to stop the study at the base station.  
RF Map  
Users can graphically view the RF Signal strength of  
the loggers and their connections to other loggers and  
basestation for stronger RF networks. A background  
image can also be set for the RF map to position the  
loggersꢀonꢀaꢀrealꢀfloorꢀplan.ꢀTheꢀusersꢀcanꢀuseꢀthisꢀasꢀ  
back up documentation for looking at the position of  
the loggers at a later time.  
3
Reports  
The Kaye RF ValProbe Software includes an intuitive,  
yet powerful reporting utility for generating Set-Up,  
Calibration, Qualification, Graph and Calibration  
Verification reports to document validation study  
results. Reports are generated from secure data files  
that can only be read by the system software. Upon  
study completion, process cycles to be analyzed are  
defined using the intuitive system graphic feature.  
Qualification  
A powerful graphing utility within the system software  
greatly simplifies process analysis and reporting. Sliding  
verticalꢀaxesꢀenableꢀtheꢀoperatorꢀtoꢀflagꢀandꢀdefineꢀ  
process transition points, eliminating unnecessary  
reporting and streamlining the review process. The  
graphꢀutilityꢀfeaturesꢀincreasedꢀflexibilityꢀforꢀgraphꢀ  
customization, including specifying X and Y axis ranges,  
background colors, line styles and labeled limit lines.  
Reports present raw process data for individual  
sensors, statistical calculations selected during study  
setup, and accumulated lethality for individual sensors.  
Summary reports present study set-up details and  
poststudy user comments, along with group interval  
and lethality calculations, as well as data for each  
group and cycle. Use of the Summary and Group  
Summary Reports can greatly reduce the need to  
export data for manipulation in Excel®.  
Any action affecting user data can be permanently  
captured in a comprehensive audit trail, which  
can be automatically stored at a network location.  
System administrators can now have fully automated  
management of passwords, audit trails and data files  
across all validation groups.  
Graph report  
Security, Passwords and Audit Trails  
The Kaye RF ValProbe is specifically designed to enable  
compliance with FDA 21 CFR Part 11. All recorded data,  
including calibration offsets, set-up parameters, and  
administrative tasks are saved in secure, encrypted,  
tamper-proof electronic records in a format accessible  
only through the system software.  
All user inputs which could impact user data, for  
example starting a study or running a calibration, are  
protectedꢀviaꢀsecureꢀusername/passwordꢀlogins,ꢀandꢀ  
are all logged in the secure audit trail database.  
Summary Report  
Data files can be merged from multiple RF ValProbe  
and ValProbe studies. Users can add unlimited cycles,  
separating qualification data into specific process  
phases, and create up to 25 groups with their own  
calculations and graphs during reporting,  
Login Request  
4
The reporting software has been enhanced to enable  
easy review and printing of the audit trail based on  
dates,ꢀtimesꢀand/orꢀeventsꢀforꢀexample,ꢀtheꢀsystemꢀ  
administrator can select to review “all failed login  
attempts for the last 30 days.” There is now also  
notification to the user and logged entries in the audit  
trail if files are tampered with or deleted from within  
Windows Explorer™  
Steam in Place Application  
The Kaye RF ValProbe® system permits up to 100  
distributed nodes, measuring both temperature and  
pressure. The system allows large SIP systems to  
be validated or re-validated in single large sections  
without the need for repeated SIP studies.  
The temperature sensor is a precision small diameter  
bendable type RTD designed to permit easy access to  
pipes and vessels through gaskets. The temperature  
probe remains in place and can be fed along pipe work  
or placed into stainless vessels or filter bodies.  
Mean Kinetic Temperature  
The Reporting Software provides Mean Kinetic  
Temperature calculation to the user. Mean Kinetic  
Temperature (MKT) is single calculated temperature  
at which the total amount of degradation over  
a particular period is equal to the sum of the  
individual degradations that would occur at various  
temperatures.  
The high accuracy pressure transducer is designed for  
121C and 134C operation and is calibration compliant  
to ISO 17025 at these extended temperatures. It is  
powered externally, easy to connect and simple to  
configurate with the RF ValProbe® software.  
Saturated Steam Calculation  
Easy integration between temperature and pressure  
enables EN554 compliance and determination of  
Saturated Steam conditions  
Equilibration Calculation  
5
                            
•ꢀ LoggerꢀDimensions:ꢀ1  
(7.5 in x 5 in x 1.75)  
•ꢀ BaseꢀStationꢀDimensions:ꢀ64ꢀmmꢀxꢀ32ꢀmmꢀxꢀ15ꢀmmꢀ  
(2.5 in x 1.25 in x 5 in)  
                        
90ꢀmmꢀxꢀ127ꢀmmꢀxꢀ45ꢀmmꢀ  
TheꢀInstallationꢀQualification/OperationalꢀQualificationꢀ  
Protocol defines a set of procedures to ensure that  
the Kaye Validator system is properly installed and  
operated correctly, and is adequately documented  
and controlled according to cGMP requirements. The  
documents are provided in hard copy and on CD,  
allowing users to modify the documentation to suit  
specific organizational requirements.  
Specifications  
Environmental  
System Documentation  
Body:ꢀ-40°Cꢀtoꢀ60°C,ꢀ0ꢀtoꢀ95%RHꢀnonꢀcondensing  
•ꢀExternalꢀprobe:ꢀ-196°Cꢀtoꢀ200°C  
IQ/OQ Protocol  
Temperature  
Single Channel External Sensor  
•ꢀ ±0.1°C,ꢀrangeꢀ0°Cꢀtoꢀ+60°C  
•ꢀ ±0.2°C,ꢀrangeꢀ-22°Cꢀtoꢀ0°C  
•ꢀ ±0.5°C,ꢀrangeꢀ-80°Cꢀtoꢀ–22°C  
•ꢀ ±2.0°C,ꢀ@ꢀ-196°C  
Updates and addenda are available through the Kaye  
website.  
Services  
For 2 and 5 Channel Temperature Loggers:  
±0.1Cꢀrangeꢀ–80°Cꢀtoꢀ130°C  
We provide a complete aray of services for the RF  
ValProbe® product range:  
•ꢀ Onsiteꢀinstallation,commissioningꢀandꢀIQ/OQꢀforꢀ  
RH  
RF ValProbe® system.  
•ꢀ 2%ꢀfromꢀ10ꢀtoꢀ90%RH  
•ꢀ 5%ꢀfromꢀ0ꢀtoꢀ10%,ꢀ90ꢀtoꢀ100%RH  
•ꢀ 3%ꢀatꢀ40°C,ꢀ75%RH  
•ꢀ CertificateꢀstatesꢀICHꢀPoints  
•ꢀ Operatorꢀtrainingꢀandꢀtechnicalꢀsupport.ꢀ  
•ꢀ Maintenanceꢀagreements.ꢀ  
•ꢀ Factoryꢀcalibration.ꢀ  
•ꢀ Rentalꢀservices.ꢀ  
Auxiliary Inputs  
•ꢀ Contact:ꢀdry  
•ꢀ Voltageꢀandꢀcurrentꢀ0.5%ꢀFS  
Validation Reference  
The Kaye Validator system is supported with Design  
Qualification documentation. The Validation Reference  
Binder provides a comprehensive overview of our  
QualityꢀPolicy,ꢀdescriptionꢀofꢀISOꢀ9001ꢀimplementationꢀ  
and support procedures, and standards for the  
development, testing, and maintenance of hardware  
and software. Quality Control documents, Development  
procedures, Quality Assurance procedures, Release  
documents, and Quality Assurance test documentation  
are all included.  
Battery Life (Varies ±±10%  
1 min sample rate: 8000 hours  
6
Ordering Information  
RF Thermal Validation System  
RF Steam in Place Application  
dsX2558  
X2570-12  
X2570-18  
X2570-36  
X2570S-L  
X2571-12  
RF ValProbe Base Station includes USB Cable, PC  
Software and User Manual  
X2570-20B  
X2571-20B  
RF ValProbe® Logger with External 20” Bendable  
Temperature Probe and RH Sensor  
Logger with Single 12” External Temperature Probe,  
Internal RH Sensor, no auxiliary inputs  
RF ValProbe® with External 20” Bendable temperature Probe,  
RH Sensor, 0-10v Voltage input and Contact Closure which  
accomodates Kaye Pressure Transducer  
Logger with Single 18” External Temperature Probe,  
Internal RH Sensor, no auxiliary inputs  
X2572-20B  
RF ValProbe® with External 20” Bendable temperature Probe,  
RH Sensor, 4-20mA Current Input and contact closure  
Logger with Single 36” External Temperature Probe,  
Internal RH Sensor, no auxiliary inputs  
X2576  
X2576E  
K0448  
M1989  
Kaye Pressure Transducer 110V  
Kaye Pressure Transducer 220V  
Feedthru triclover clamp  
Specify 1 or 3 standard lenght; custom length  
available on request  
Logger with Single 12” External Temperature Probe,  
Internal RH Sensor with contact switch and  
0-10V Voltage auxiliary Input  
SmartGasket® Silicone gasket  
X2571-18  
X2571-36  
Logger with Single 18” External Temperature Probe,  
Internal RH Sensor with contact switch and  
0-10V Voltage auxiliary Input  
* Please contact factory if different probe lengths are required.  
Logger with Single 36” External Temperature Probe,  
Internal RH Sensor with contact switch and  
0-10V Voltage auxiliary Input  
X2571S-L  
X2572-12  
Specify 1 or 3 standard lenght; custom length  
available on request  
Logger with Single 12” External Temperature Probe,  
Internal RH Sensor with contact switch and  
4-20mA current loop auxiliary Input  
X2572-18  
X2572-36  
Logger with Single 18” External Temperature Probe,  
Internal RH Sensor with contact switch and  
4-20mA current loop auxiliary Input  
Logger with Single 36” External Temperature Probe,  
Internal RH Sensor with contact switch and  
4-20mA current loop auxiliary Input  
X2572S-L  
X2563  
Specify 1 or 3 standard lenght; custom length  
available on request  
Internal Temperature and RH Logger, Voltage  
and Contact Auxiliary  
X2564  
InternalꢀTemperatureꢀandꢀRHꢀLogger,ꢀ4/20mAꢀCurrent  
and Contact Auxiliary  
X6030  
RFꢀValProbeꢀIQ/OQꢀProtocol  
X6035  
RF ValProbe Validation Reference (DQ) Package  
X2573-3  
RF ValProbe Dual Channel Logger with external  
3” Temperature Probes  
X2573-6  
X2573S-L  
X2574-6  
X2574-15  
X2574S-L  
RF ValProbe Dual Channel Logger with external  
6” Temperature Probes  
RF ValProbe Dual Channel Logger with external L’  
Temperature Probes  
RF ValProbe Five Channel Logger with external  
6” Temperature Probes  
RF ValProbe Five Channel Logger with external  
15” Temperature Probes  
RF ValProbe Five Channel Logger with external L’  
Temperature Probes  
7
www.amphenol-sensors.com  
© 2014 Amphenol Corporate. All Rights Reserved. Specifications are subject to change without notice.  
Dust, Dust Networks and SmartMesh are registered trademarks of Linear Technology Corporation.  
Other company names and product names used in this document are the registered trademarks or  
trademarks of their respective owners.  
Amphenol  
Advanced Sensors  
AAS-921-42±E-12/21±4  

相关型号:

X2572-20B

RF Mesh Networking technology provides reliable real time process data. Uses global 2.4 GHz RF frequencies
AMPHENOL

X2572-36

RF Mesh Networking technology provides reliable real time process data. Uses global 2.4 GHz RF frequencies
AMPHENOL

X2572S-L

RF Mesh Networking technology provides reliable real time process data. Uses global 2.4 GHz RF frequencies
AMPHENOL

X2573-3

RF Mesh Networking technology provides reliable real time process data. Uses global 2.4 GHz RF frequencies
AMPHENOL

X2573-6

RF Mesh Networking technology provides reliable real time process data. Uses global 2.4 GHz RF frequencies
AMPHENOL

X2573S-L

RF Mesh Networking technology provides reliable real time process data. Uses global 2.4 GHz RF frequencies
AMPHENOL

X2574-15

RF Mesh Networking technology provides reliable real time process data. Uses global 2.4 GHz RF frequencies
AMPHENOL

X2574-6

RF Mesh Networking technology provides reliable real time process data. Uses global 2.4 GHz RF frequencies
AMPHENOL

X2574S-L

RF Mesh Networking technology provides reliable real time process data. Uses global 2.4 GHz RF frequencies
AMPHENOL

X2576

RF Mesh Networking technology provides reliable real time process data. Uses global 2.4 GHz RF frequencies
AMPHENOL

X2576E

RF Mesh Networking technology provides reliable real time process data. Uses global 2.4 GHz RF frequencies
AMPHENOL

X25C02

SPI Serial E2PROM
XICOR