YA40-N-90U [AMPHENOL]
Ring Terminal, 400mm2;型号: | YA40-N-90U |
厂家: | Amphenol |
描述: | Ring Terminal, 400mm2 端子和端子排 |
文件: | 总5页 (文件大小:91K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
BURNDY
Compression
BEVELED
ENTRY
ONE HOLE HYLUG™
DIE AND COLOR
CODE INFORMATION
CODE CONDUCTOR
LONG BARREL
NO INSPECTION
WINDOW
TYPES YA,YA-TC
CRIMPS
UNINSULATED COPPER
COMPRESSION TERMINAL
CABLE
ACCOMMODATION
ELECTRO-TIN
PLATED
C-16
UL Listed 90° C,
600 Volts to 35 KV ◆
B
90°
B
T
T
T
45°
L
L
L
Fig. 1
Fig. 3
Fig. 2
Conductor
***
◆ Installation Tooling
Stud
Hole Tongue
Figure
Dimensions
(T)
Mechanical
Hydraulic
Wire
Strip
Dieless
(# of crimps)
MD6, OUR840, BCT500HS,
MD7-34R Y500CTHS
Y35,Y39,Y750
Y46*, PAT750
Color Die
Catalog Number
YA8C-TC10
YA8C-TC10-45
YA8C-TC10-90
YA8C-TC14
YA8C-TC14-45
YA8C-TC14-90
YA8C-TC38
YA8C-TC38-45
YA8C-TC38-90
YA6C-TC10
YA6C-TC10-45
YA6C-TC10-90
YA6C-N
Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
AWG
MM2 Size
Width
(B)
(L)
Code Index Length
1.57ꢀ
1.46ꢀ
.68ꢀ
#8 AWG
#8 WELD
37/24
# 10 .38ꢀ
.81ꢀ
.08ꢀ
.08ꢀ
.06ꢀ
MRC840 (2)
Y8MBR-1 (1)
Y2MR (2)
1.69ꢀ
1.57ꢀ
.86ꢀ
W8CVT (2) X8CRT (2)
W8CRT (2) W8CVT (2)
X8CRT (2) W8CRT (2)
†
1/4ꢀ
3/8ꢀ
.41ꢀ
.58ꢀ
.81ꢀ
.81ꢀ
U8CRT (2)
Red 49
1ꢀ
10
Y1MR (2)
1.88ꢀ
1.71ꢀ
1.04ꢀ
1.89ꢀ
1.72ꢀ
.75ꢀ
#6 SOL
# 10 .41ꢀ
1.12ꢀ .09ꢀ
1.12ꢀ .12ꢀ
1.12ꢀ .09ꢀ
1.12ꢀ .07ꢀ
1.12ꢀ .12ꢀ
MRC840 (2)
MY29-3 (2) W5CVT (2) W5CVT (2)
MY29-11 (2) W5CRT (2) W5CRT (2)
2.64ꢀ
2.53ꢀ
1.52
U5CRT (2)
YA6C-N-45
YA6C-N-90
YA6C
#6 AWG
-
1/2ꢀ
1/4ꢀ
1/4ꢀ
1/2ꢀ
.83ꢀ
.41ꢀ
.44ꢀ
.83ꢀ
Blue
7
1-3/16ꢀ
Y2MR (2)
X5CRT (2) X5CRT (2)
U8CABT (2)
Y644M (1) X8CART (2) X8CART (2)
Y1MR (1)
1.81ꢀ
1.24ꢀ
.81ꢀ
YA6C-45
YA6C-90
YA5C
YA5C-45
1.98ꢀ
1.75ꢀ MRC840 (2)
Y1MR (1)
W5CVT (2) W5CVT (2)
W5CRT (2) W5CRT (2)
X5CRT (2) X5CRT (2)
YA5C-90
YA5C-N
.81ꢀ
2.67ꢀ MY29-11 (2)
MY29-3 (2)
#5 AWG
#4 AWG
-
U5CRT (2)
Blue
Gray
7
8
1-3/16ꢀ
1-3/16ꢀ
YA5C-N-45
YA5C-N-90
YA4C-TC10
YA4C-TC10-45
YA4C-TC10-90
YA4C
2.55ꢀ
1.52ꢀ
Y2MR (2)
Y644M (1)
1.94ꢀ MRC840 (2)
1.94ꢀ MY29-3 (2) W4CVT (2) W4CVT (2)
1.75ꢀ MY29-11 (2) W4CRT (2) W4CRT (2)
# 10 .49ꢀ
1.12ꢀ .09ꢀ
1.12ꢀ .09ꢀ
U4CRT (2)
U6CABT (2)
1.87ꢀ
1.52ꢀ
Y2MR (4)
Y644M (1)
X4CRT (2) X4CRT (2)
1/4ꢀ
.50ꢀ
YA4C-45
*
Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
†
The MM2 conductor size listed is for Class 2 and Class 5
conductor.
•
Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
◆ For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.
◆ See tooling section of this catalog for complete tool and die
listings. Use ONLY color coded die recommendations for "-
FX" connectors. For nest/indentor system contact factory.
BURNDY
Compression
ONE HOLE HYLUG™
B
CODE CONDUCTOR
LONG BARREL
(Continued)
B
90°
T
T
T
45°
L
L
L
Fig. 1
Fig. 2
Fig. 3
Conductor
◆ Installation Tooling
Stud
Figure
Dimensions
(T)
Mechanical
MD6, OUR840, BCT500HS,
MD7-34R Y500CTHS
Hydraulic
Wire
Strip
***
Hole Tongue
Dieless
(# of crimps)
Y35,Y39,Y750,
Y46*, PAT750
Color Die
Catalog Number
YA4C-90
Fig #
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
MM2 Size
Width
(B)
(L)
Code Index Length
C-17
1/4ꢀ
.56ꢀ
1.12’ .09ꢀ
.84ꢀ
MRC840 (2)
MY29-3 (2)
MY29-11 (2)
Y2MR (4)
YA4C-TC38
YA4C-TC38-45
YA4C-TC38-90
YA4C-N
2.25ꢀ
2.02ꢀ
1.08ꢀ
2.69ꢀ
2.56ꢀ
1.54ꢀ
2.23ꢀ
1.99ꢀ
.92ꢀ
3/8ꢀ
.58ꢀ
.83ꢀ
.55ꢀ
1.12ꢀ .08ꢀ
W4CVT (2) W4CVT (2)
W4CRT (2) W4CRT (2)
X4CRT (2) X4CRT (2)
U4CRT (2)
#4 AWG
-
Gray
8
1-3/16ꢀ
U6CABT (2)
Y644M (1)
Y1MR (4)
YA4C-N-45
YA4C-N-90
YA3C-TC14
YA3C-TC14-45
YA3C-TC14-90
YA3C
1/2ꢀ
1/4ꢀ
1.12ꢀ .12ꢀ
1.25ꢀ .09ꢀ
1.25ꢀ .09ꢀ
1.25ꢀ .08ꢀ
1.25ꢀ .12ꢀ
1.25ꢀ .11ꢀ
1.25ꢀ .11ꢀ
1.25ꢀ .11ꢀ
1.25ꢀ .12ꢀ
1.38ꢀ .10ꢀ
1.38ꢀ .10ꢀ
1.38ꢀ .12ꢀ
1.38ꢀ .12ꢀ
1.38ꢀ .12”
1.38ꢀ .12ꢀ
2.30ꢀ
2.05ꢀ MY29-3 (2)
.98ꢀ MY29-11 (2) W3CRT (2) W3CRT (2)
YA3C-45
YA3C-90
#3 AWG
5/16ꢀ .55ꢀ
25
U3CRT (2)
White
9
1-1/2ꢀ
YA3C-TC38
YA3C-TC38-45
YA3C-TC38-90
YA3CN
#2 SOLID
2.42ꢀ
2.16ꢀ
1.10ꢀ
2.86ꢀ
2.68ꢀ
1.56ꢀ
2.10ꢀ
1.90ꢀ
.82ꢀ
Y644M (1)
3/8ꢀ
1/2ꢀ
.61ꢀ
.81ꢀ
YA3CN-45
YA3CN-90
YA2C-TC10
YA2C-TC10-45
YA2C-TC10-90
YA2C-TC14
YA2C-TC14-45
YA2C-TC14-90
YA2C
# 10 .61ꢀ
2.23ꢀ
2.02ꢀ MRC840 (2)
Y1MR (4)
1/4ꢀ
.60ꢀ
W2CVT (2) W2CVT (2)
W2CRT (2) W2CRT (2)
X2CRT (2) X2CRT (2)
.95ꢀ
2.29ꢀ MY29-11 (2)
MY29-3 (2)
#2 AWG
35
U2CRT (2)
Brown 10 1-5/16ꢀ
YA2C-45
YA2C-90
YA2C-N
5/16ꢀ .61ꢀ
2.09ꢀ
1.01ꢀ
2.88ꢀ
2.70ꢀ
1.58ꢀ
2.27ꢀ
2.00ꢀ
.84ꢀ
Y2MR (4)
Y644M (1)
YA2C-N-45
YA2C-N-90
YA1C-TC10
YA1C-TC10-45
YA1C-TC10-90
YA1C
1/2ꢀ
.83ꢀ
# 10 .68ꢀ
Y1MR (4)
2.45ꢀ MRC840 (2) W1CVT (2) W1CVT (2)
2.19ꢀ MY29-3 (2) W1CRT-1 (2) W1CRT-1 (2)
1.03ꢀ MY29-11 (2) X1CRT-1 (2) X1CRT-1 (2)
U1CRT-1 (2)
U4CABT (2)
YA1C-45
YA1C-90
YA1C-N
#1 AWG
50 5/16ꢀ .68ꢀ
Green 11 1-7/16ꢀ
3.06ꢀ
2.82ꢀ
1.60ꢀ
2.30ꢀ
2.06ꢀ
.88ꢀ
Y644M (1)
YA1C-N-45
YA1C-N-90
YA25TC10
YA25TC10-45
YA25TC10-90
YA25
1/2ꢀ
.83ꢀ
# 10 .75ꢀ
5/16ꢀ .75ꢀ
MRC840 (4)
MY29-3 (2)
MY29-11 (2)
Y644M (1)
2.48ꢀ
2.25ꢀ
1.07ꢀ
2.61ꢀ
2.37ꢀ
1.19ꢀ
W25VT (4) W25VT (4)
W25RT (4) W25RT (4)
X25RT (4) X25RT (4)
U25RT (2)
YA25-45
YA25-90
1/0 AWG
-
Pink 12 1-7/16ꢀ
U2CABT (2)
YA25TC38
YA25TC38-45
YA25TC38-90
3/8ꢀ
.75ꢀ
*
Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.
◆ See tooling section of this catalog for complete tool and die
listings. Use ONLY color coded die recommendations for
"-FX" connectors. For nest/indentor system contact factory.
•
Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
◆ For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.
BURNDY
Compression
ONE HOLE HYLUG™
B
CODE CONDUCTOR
LONG BARREL
(Continued)
B
90°
T
T
T
45°
L
L
L
Fig. 1
Fig. 2
Fig. 3
Conductor
◆ Installation Tooling
Stud
Figure
Dimensions
(T)
Mechanical
MD6, OUR840, BCT500HS,
MD7-34R Y500CTHS
Hydraulic
Wire
Strip
***
Hole Tongue
Dieless
Y35,Y39,Y750,
Y46*, PAT750
Color Die
Catalog Number
Fig #
AWG
MM2 Size
Width
(B)
(L)
(# of crimps)
MRC840 (4)
MY29-3 (2)
MY29-11 (2)
Y644M (1)
Code Index Length
C-18
YA25N
1
3.05ꢀ
W25VT(4) W25VT (4)
W25RT (4) W25RT (4)
X25RT (4) X25RT (4)
1/0
U25RT (2)
YA25N-45
YA25N-90
2
3
-
70
-
1/2ꢀ
.81ꢀ
1.38ꢀ .11ꢀ
2.79ꢀ
1.62ꢀ
2.77ꢀ
Pink 12 1-7/16ꢀ
AWG
U2CABT (2)
YA26
1
2
3
1
2
3
YA26-45
YA26-90
YA26N
3/8ꢀ
1/2ꢀ
.83ꢀ
.83ꢀ
1.50ꢀ .12ꢀ
1.50ꢀ .12ꢀ
2.49ꢀ MRC840 (4)
1.22ꢀ MY29-3 (2)
3.21ꢀ MY29-11 (2)
W26VT (4) W26VT (4)
W26RT (4) W26RT (4)
X26RT (4) X26RT (4)
2/0
U26RT (2)
U27RT (2)
Black 13 1-9/16ꢀ
Orange 14 1-9/16ꢀ
Purple 15 1-1/16ꢀ
AWG
YA26N-45
YA26N-90
2.93ꢀ
1.65ꢀ
Y644M (1)
MRC840 (4)
MY29-3 (2)
MY29-11 (2)
Y644M (1)
YA27
1
2
3
3.06ꢀ
2.78ꢀ
1.49ꢀ
2.98ꢀ
W27VT (4) W27VT (4)
W27RT (4) W27RT (4)
X27RT (6) X27RT (6)
YA27-45
YA27-90
3/0 AWG
1/2ꢀ
.91ꢀ
1.50ꢀ .13ꢀ
YA28TC38
YA28TC38-45
YA28TC38-90
YA28
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
3/8ꢀ
1/2ꢀ
2.68ꢀ MRC840 (4)
1.29ꢀ MY29-3 (2)
3.23ꢀ MY29-11 (2)
W28VT (4) W28VT (4)
W28RT (4) W28RT (4)
X28RT (6) X28RT (6)
4/0 AWG
250 kcmil
-
-
1.02ꢀ 1.62ꢀ .14ꢀ
U28RT (2)
U29RT (2)
YA28-45
YA28-90
YA29
2.93ꢀ
1.54ꢀ
Y644M (1)
3.26ꢀ MY29-3 (2)
2.99ꢀ MY29-11 (2)
W29VT (4)
W29VT (4)
YA29-45
YA29-90
YA30
1/2ꢀ 1.11ꢀ 1.62ꢀ .16ꢀ
W29RT (4)
Yellow 16 1-1/16ꢀ
X29RT (8)
1.58ꢀ
3.69ꢀ
3.31ꢀ
1.61ꢀ
3.73ꢀ
3.36ꢀ
1.65ꢀ
4.09ꢀ
3.71ꢀ
1.88ꢀ
4.15ꢀ
3.77ꢀ
1.95ꢀ
Y644M (1)
X29RT (8)
W30VT (4)
U30RT (4)
17 or
YA30-45
YA30-90
YA31
300 kcmil 150 1/2ꢀ 1.20ꢀ 2.00ꢀ .16ꢀ
350 kcmil 185 1/2ꢀ 1.29ꢀ 2.00ꢀ .18ꢀ
1/2ꢀ 1.38ꢀ 2.12ꢀ .19ꢀ
Y644M (1) W30VT (4)
Y644M (1) W31VT (4)
White
Red
2-1/16ꢀ
2-1/16ꢀ
W30RT (4)
U28ART (4)
298
W31VT (4)
W31RT (4)
U31RT (4)
18 or
324
YA31-45
YA31-90
YA32N
U29ART (4)
YA32N-45
YA32N-90
YA32
W32VT (4)
W32RT (4)
U32RT (4)
19 or
470
400 kcmil
-
Y644M (1) W32VT (4)
Blue
2-3/16ꢀ
U30ART (4)
YA32-45
YA32-90
5/8ꢀ 1.38ꢀ 2.12ꢀ .19ꢀ
*
Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.
◆ See tooling section of this catalog for complete tool and die
listings. Use ONLY color coded die recommendations for
"-FX" connectors. For nest/indentor system contact factory.
•
Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
◆ For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.
BURNDY
Compression
ONE HOLE HYLUG™
B
CODE CONDUCTOR
LONG BARREL
(Continued)
B
90°
T
T
T
45°
L
L
L
Fig. 1
Fig. 2
Fig. 3
Conductor
◆ Installation Tooling
Stud
Figure
Dimensions
(T)
Mechanical
MD6, OUR840, BCT500HS,
MD7-34R
Hydraulic
Wire
Strip
***
Hole Tongue
Dieless
(# of crimps)
Y35,Y39,Y750,
Y46*, PAT750
Color Die
Catalog Number
YA33
Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
MM2 Size
Width
(B)
(L)
Y500CTHS
Code Index Length
C-19
4.24ꢀ
3.87ꢀ
2.00ꢀ
4.17ꢀ
3.81ꢀ
1.94ꢀ
4.32ꢀ
3.96ꢀ
1.97ꢀ
4.39ꢀ
4.02ꢀ
2.03ꢀ
4.79ꢀ
4.37ꢀ
2.08ꢀ
4.73ꢀ
4.30ꢀ
2.01ꢀ
4.83ꢀ
4.41ꢀ
2.05ꢀ
4.90ꢀ
4.47ꢀ
2.11ꢀ
5.05ꢀ
4.59ꢀ
2.14ꢀ
4.98ꢀ
4.53ꢀ
2.08ꢀ
5.07ꢀ
4.60ꢀ
2.15ꢀ
5.01ꢀ
4.53ꢀ
2.08ꢀ
5.11ꢀ
4.62ꢀ
2.11ꢀ
5.17ꢀ
4.68ꢀ
2.17ꢀ
5.25ꢀ
4.80ꢀ
2.21ꢀ
5.19ꢀ
4.74ꢀ
2.15ꢀ
-
YA33-45
YA33-90
YA33-N
5/8ꢀ 1.48ꢀ 2.13ꢀ .21ꢀ
1/2ꢀ 1.48ꢀ 2.13ꢀ .21ꢀ
1/2ꢀ 1.52ꢀ 2.25ꢀ .23ꢀ
5/8ꢀ 1.52ꢀ 2.25ꢀ .23ꢀ
5/8ꢀ 1.65ꢀ 2.63ꢀ .25ꢀ
1/2ꢀ 1.65ꢀ 2.63ꢀ .25ꢀ
1/2ꢀ 1.69ꢀ 2.69ꢀ .27ꢀ
5/8ꢀ 1.69ꢀ 2.69ꢀ .27ꢀ
5/8ꢀ 1.80ꢀ 2.81ꢀ .27ꢀ
1/2ꢀ 1.80ꢀ 2.81ꢀ .27ꢀ
5/8ꢀ 1.84ꢀ 2.81ꢀ .27ꢀ
1/2ꢀ 1.84ꢀ 2.81ꢀ .27ꢀ
1/2ꢀ 1.89ꢀ 2.88ꢀ .27ꢀ
5/8ꢀ 1.89ꢀ 2.88ꢀ .27ꢀ
5/8ꢀ 1.98ꢀ 2.94ꢀ .30ꢀ
1/2ꢀ 1.98ꢀ 2.94ꢀ .30ꢀ
W33VT (4)
W33RT (4)
326 or
450 kcmil
-
W33VT (4)
U33RT (4)
Gray
2-5/16ꢀ
2-5/16ꢀ
538
YA33-N-45
YA33-N-90
YA34N
YA34N-45
YA34N-90
YA34
W34VT (4)
W34RT (4)
U34RT (4)
20 or
299
500 kcmil 240
W34VT (4)
Brown
U31ART (4)
YA34-45
YA34-90
YA35
YA35-45
YA35-90
YA35-N
550 kcmil
-
-
-
-
-
-
-
-
-
U35RT (4)
Yellow 21 2-11/16ꢀ
YA35-N-45
YA35-N-90
YA36N
YA36N-45
YA36N-90
YA36
U36RT (4)
22 or
600 kcmil 300
Green
2-3/4ꢀ
U32ART (4)
472
YA36-45
YA36-90
YA37
Y644M (1)
YA37-45
YA37-90
YA37-N
650 kcmil
700 kcmil
750 kcmil
-
-
-
-
U37RT (4)
U38RT (4)
Orange 23 2-7/8ꢀ
Pink 400 2-7/8ꢀ
Black 24 2-15/16ꢀ
YA37-N-45
YA37-N-90
YA38
YA38-45
YA38-90
YA38-N
-
-
YA38-N-45
YA38-N-90
YA39N
YA39N-45
YA39N-90
YA39
U39RT (4)
P39RT (4)
**
-
-
YA39-45
YA39-90
YA40
YA40-45
YA40-90
YA40-N
P40RT (4)
**
800 kcmil 400
Orange 25
3ꢀ
YA40-N-45
YA40-N-90
*
Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
◆ See tooling section of this catalog for complete tool and
die listings. Use ONLY color coded die recommendations
for "-FX" connectors. For nest/indentor system contact
factory.
◆ For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.
•
Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
BURNDY
Compression
ONE HOLE HYLUG™
B
CODE CONDUCTOR
LONG BARREL
(Continued)
B
90°
T
T
T
45°
L
L
L
Fig. 1
Fig. 2
Fig. 3
Conductor
◆ Installation Tooling
Stud
Figure
Dimensions
(T)
Mechanical
MD6, OUR840, BCT500HS,
MD7-34R
Hydraulic
Wire
Strip
***
Hole Tongue
Dieless
(# of crimps)
Y35,Y39,Y750,
Y46*, PAT750
Color Die
Catalog Number
YA41
Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
MM2 Size
Width
(B)
(L)
Y500CTHS
Code Index Length
C-20
5.26ꢀ
4.82ꢀ
2.23ꢀ
5.20ꢀ
4.76ꢀ
2.17ꢀ
5.45ꢀ
5.01ꢀ
2.32ꢀ
5.38ꢀ
4.95ꢀ
2.26ꢀ
5.93ꢀ
5.52ꢀ
2.62ꢀ
5.68ꢀ
5.27ꢀ
2.37ꢀ
6.04ꢀ
5.64ꢀ
2.71ꢀ
5.79ꢀ
5.39ꢀ
2.46ꢀ
6.38ꢀ
5.94ꢀ
2.79ꢀ
6.13ꢀ
5.69ꢀ
2.54ꢀ
6.47ꢀ
6.09ꢀ
2.89ꢀ
6.22ꢀ
5.84ꢀ
2.64ꢀ
YA41-45
YA41-90
YA41-N
5/8ꢀ 2.01ꢀ 2.94ꢀ .31ꢀ
1/2ꢀ 2.01ꢀ 2.91ꢀ .31ꢀ
5/8ꢀ 2.17ꢀ 3.00ꢀ .33ꢀ
1/2ꢀ 2.19ꢀ 3.00ꢀ .33ꢀ
3/4ꢀ 2.46ꢀ 3.19ꢀ .38ꢀ
1/2ꢀ 2.46ꢀ 3.19ꢀ .38ꢀ
3/4ꢀ 2.69ꢀ 3.19ꢀ .40ꢀ
1/2ꢀ 2.69ꢀ 3.19ꢀ .40ꢀ
3/4ꢀ 2.90ꢀ 3.44ꢀ .42ꢀ
1/2ꢀ 2.90ꢀ 3.44ꢀ .42ꢀ
3/4ꢀ 3.10ꢀ 3.44ꢀ .46ꢀ
1/2ꢀ 3.10ꢀ 3.44ꢀ .46ꢀ
850 kcmil
-
-
-
-
Gold 26
3ꢀ
YA41-N-45
YA41-N-90
YA44
Y644M (1)
YA44-45
YA44-90
YA44-N
P44RT (4)
**
1000 kcmil 500
-
-
-
-
-
-
-
-
-
-
White 27 3-1/16ꢀ
Yellow 29 3-1/4ꢀ
Green 31 3-5/16ꢀ
Gray 33 3-1/2ꢀ
Brown 34 3-1/2ꢀ
YA44-N-45
YA44-N-90
YA45
YA45-45
YA45-90
YA45-N
P45RT (6)
**
1250 kcmil
1500 kcmil
1750 kcmil
2000 kcmil
-
-
-
-
YA45-N-45
YA45-N-90
YA46
YA46-45
YA46-90
YA46-N
P46RT (6)
**
YA46-N-45
YA46-N-90
YA47
YA47-45
YA47-90
YA47-N
-
-
YA47-N-45
YA47-N-90
YA48
YA48-45
YA48-90
YA48-N
YA48-N-45
YA48-N-90
*
Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
•
Available undrilled. Add suffix "U" to catalog number
(example: YA25U).
◆ For applications greater than 2000 Volts consult cable
manufacturer for voltage stress relief instructions.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM2 conductor sizes listed are the recommendations
for Class 2 conductor.
◆ See tooling section of this catalog for complete tool and die
listings. Use ONLY color coded die recommendations for
"-FX" connectors. For nest/indentor system contact factory.
相关型号:
©2020 ICPDF网 联系我们和版权申明