Data Sheet - Rev 2.1  
FEATURES  
Low cost integrated monolothic GaAs amplifier  
with step attenuator  
Attenuation Range: 0-56 dB, adjustable in  
4 dB increments via a 4 wire parallel control  
Meets DOCSIS distortion requirements at  
+60 dBmV output signal level  
Low distortion and low noise  
Frequency range: 5-100 MHz  
5 Volt operation  
0 to +85 °C temperature range  
APPLICATIONS  
MCNS/DOCSIS Compliant Cable Modems  
CATV Interactive Set-Top Box  
Telephony over Cable Systems  
OpenCable Set-Top Box  
S12 Package  
28 Pin SSOP with Heat Slug  
Residential Gateway  
PRODUCT DESCRIPTION  
The ARA1400 is a GaAs IC designed to provide the  
reverse path amplification and output level control  
functions in a CATV Set-Top Box or Cable Modem. It  
incorporates a digitally controlled precision step  
attenuator that is preceded by an ultra low noise  
amplifier stage, and followed by an ultra-linear  
output driver amplifier. The device is capable of  
meeting the MCNS/DOCSIS requirements for  
harmonic performance at a +60dBmV output level  
while requiring only a single polarity +5V supply.  
Both the input and the output are single-ended and  
matched to 75 Ohms, and a precision attenuator  
provides up to 56 dB of attenuation in 4 dB  
increments. The device is offered in a 28-pin SSOP  
package featuring a heat slug on the bottom of the  
package.  
4
Attenuation Control  
Upstream  
QPSK/16QAM  
Modulator  
ARA1400  
LPF  
Balun  
RAM  
ROM  
Clock  
Data  
Data  
Transmit Enable/Disable  
Microcontroller  
with Ethernet  
MAC  
5-42 MHz  
MAC  
Clock  
44 MHz  
SAW  
Filter  
Double-  
Conversion  
Tuner  
QAM Receiver  
with FEC  
54-860 MHz  
RJ45  
Connector  
10Base-T  
Transceiver  
Diplexer  
Figure 1: Cable Modem or Set Top Box Application Diagram  
03/2004  
ARA1400  
RFOUT1  
ATT IN  
ATT OUT  
RFIN2  
56 dB 4 dB step digital attenuator section  
RFIN  
RFOUT  
AMP  
AMP  
ISET1  
32 dB  
16 dB  
8 dB  
4 dB  
ISET2  
Tx  
Figure 2: Functional Block Diagram  
GND  
N/C  
ATTOUT  
1
28  
I
SET2  
2
3
27  
26  
25  
24  
23  
22  
21  
20  
19  
ATTIN  
RFIN2  
RFOUT1  
Tx  
4
VREF1  
ATTACG3  
5
ATT ACG1  
ATT ACG1  
ATT ACG1  
ATT ACG1  
RFIN  
ATTACG2  
ATTACG2  
ATTACG2  
ATTACG2  
RFOUT  
6
7
8
9
10  
I
SET1  
VREF2  
11  
12  
13  
14  
18  
17  
16  
15  
VATT  
VA2  
32 dB  
16 dB  
4 dB  
8 dB  
Figure 3: Pinout  
Data Sheet - Rev 2.1  
03/2004  
2
ARA1400  
Table 1: Pin Description  
PIN  
1
NAME  
GND  
N/C  
DESCRIPTION  
PIN  
15  
NAME  
DESCRIPTION  
Ground  
8 dB  
4 dB  
82 dB Attenution Control Bit  
4 dB Attenution Control Bit  
Amplifier A2 Supply  
(1)  
2
No Connection  
16  
3
ATTIN  
Attenuator Input (2)  
17  
V
A2  
Amplifier A1 Output and  
Supply  
Reference Voltage for  
Amplifier A2  
4
5
RFOUT1  
18  
19  
V
REF2  
Reference Voltage for  
Amplifier A1  
V
REF1  
RFOUT  
RF Output from Switch (2)  
(3)  
(3)  
(3)  
(3)  
(3)  
6
7
ATTACG1  
ATTACG1  
ATTACG1  
ATTACG1  
RFIN  
Attenuator AC Ground 1  
Attenuator AC Ground 1  
Attenuator AC Ground 1  
Attenuator AC Ground 1  
Amplifier A1 Input (4)  
20  
21  
22  
23  
24  
25  
26  
27  
28  
ATTACG2  
ATTACG2  
ATTACG2  
ATTACG2  
ATTACG3  
Tx  
Attenuator AC Ground 2  
(3)  
Attenuator AC Ground 2  
(3)  
8
Attenuator AC Ground 2  
(3)  
9
Attenuator AC Ground 2  
(3)  
10  
11  
12  
13  
Attenuator AC Ground 3  
ISET1  
Amplifier A1 Current Adjust  
Attenuator Supply  
Output Switch Control  
Amplifier A2 Input (4)  
V
ATT  
RFIN2  
32 dB  
16 dB  
32 dB Attenution Control Bit  
16 dB Attenution Control Bit  
ISET2  
Amplifier A2 Current Adjust  
Attenuator Output (2)  
14  
ATTOUT  
Notes:  
(1) All N/C pins should be grounded.  
(2) Pins should be AC-coupled. No external DC bias should be applied.  
(3) Pins should be AC-grounded. No external DC bias should be applied.  
(4) Pins should be AC-coupled from the RF path, and should be pulled to ground through a resistor.  
Data Sheet - Rev 2.1  
03/2004  
3
ARA1400  
ELECTRICAL CHARACTERISTICS  
Table 2: Absolute Minimum and Maximum Ratings  
PARAMETER  
MIN  
MAX  
UNIT  
Analog Supply: VSUP (pins 4, 12, 17)  
0
9
VDC  
V
SUP  
2
Amplifier Reference Voltages (pins 5, 18)  
-2.5  
VDC  
RF Power at Amplifier Inputs (pins 10, 26  
Attenuator Controls (pins 13, 14, 15, 16)  
Output Switch Control (pin 25)  
Storage Temperature  
)
-
0
+60  
6
dBmV  
V
0
6
V
-55  
-
+200  
260  
5
°C  
Soldering Temperature  
°C  
Soldering Time  
-
Sec  
Stresses in excess of the absolute ratings may cause permanent damage.  
Functional operation is not implied under these conditions. Exposure to absolute  
ratings for extended periods of time may adversely affect reliability.  
Notes:  
1. Pins 3, 19, and 28 should be AC-coupled. No external DC bias should be applied.  
2. Pins 11 and 27 should be grounded or pulled to ground through a resistor. No external  
DC bias should be applied.  
3. Pins 6, 7, 8, 9, 20, 21, 22, 23 and 24 should be AC-grounded. No external DC bias  
should be applied.  
4. Pins 10 and 26 should be AC-coupled from the RF path, and should be pulled to  
ground through a resistor.  
Table 3: Operating Ranges  
PARAMETER  
MIN  
TYP  
MAX  
UNIT  
Amplifier Supply: VDD (pins 4, 17)  
Attenuator Supply: VATTN (pin 12)  
Attenuator Controls (pins 13, 14, 15, 16)  
Amplifier Reference Voltages (pins 5, 18)  
Output Switch Control (pin 25)  
Case Temperature  
4.5  
5
5
7
7
VDC  
VDC  
V
V
DD-0.5  
0
-
-
5.5  
-
1.75  
-
VDC  
V
0
0
5.5  
85  
25  
°C  
The device may be operated safely over these conditions; however, parametric  
performance is guaranteed only over the conditions defined in the electrical specifications.  
Data Sheet - Rev 2.1  
03/2004  
4
ARA1400  
Table 4: DC Electrical Specifications  
(T  
A
= 25 °C; VDD,VATTN = +5.0 VDC)  
PARAMETER  
MIN  
TYP  
MAX  
UNIT  
COMMENTS  
Amplifier A1 Current (pin 4)  
Amplifier A2 Current (pin 17)  
Attenuator Current (pin 12)  
Total Power Consumption  
-
-
-
-
74  
108  
12  
95  
130  
20  
mA  
mA  
mA  
W
0.97  
1.23  
Table 5: AC Electrical Specifications  
= 25 °C; VDD, VATTN = +5.0 VDC; Tx = 0 V (switch closed), Tx = +5 V (switch open))  
(T  
A
PARAMETER  
MIN  
TYP  
MAX  
UNIT COMMENTS  
Gain (10 MHz)  
30  
-
32  
33  
-
dB  
dB  
0 dB attenuation setting  
Gain Flatness  
0.75  
5 to 100 MHz  
Gain Variation over Temperature  
-
-0.006  
-
dB/°C  
Attenuation Steps  
4 dB  
3.6  
7.7  
3.9  
8.0  
4.2  
8.3  
8 dB  
dB  
Monotonic  
16 dB  
15.3  
31.0  
15.7  
31.5  
16.1  
32.0  
32 dB  
Difference in output  
signal level between  
active and standby  
Switch Isolation at 45 MHz  
-
35  
30  
dB  
Harmonics (fo = 10MHz)  
2fo  
3fo  
-
-
-57  
-64  
-52  
-56  
fo power = +60 dBmV  
into 75 Ohms  
dBc  
3rd Order Output Intercept  
1 dB Gain Compression Point  
Noise Figure  
78  
-
-
-
-
dBmV  
dBmV  
dB  
70  
1.7  
-
2.5  
Output Noise Power  
Active / No Signal / Min. Atten. Set.  
Active / No Signal / Max. Atten. Set.  
-
-
-
-
-37.6  
-54.6  
dBmV Any 160 kHz bandwidth  
from 5 to 42 MHz  
Input Impedance  
-
75  
-
Ohms  
Note: As measured in ANADIGICS test fixture.  
Data Sheet - Rev 2.1  
03/2004  
5
ARA1400  
continued: AC Electrical Specifications  
(TA  
= 25 °C; VDD, VATTN = +5.0 VDC; Tx = 0 V (switch closed), Tx = +5 V (switch open))  
PARAMETER  
MIN  
TYP  
MAX  
UNIT COMMENTS  
Input Return Loss  
-
-20  
-15  
dB  
(75 Ohm characteristic impedance)  
-20  
-12  
-15  
-10  
Switch closed  
Ohms  
Output Impedance  
-
Switch open  
Output Return Loss  
-
-
-17  
-15  
-12  
-10  
Switch closed  
dB  
(75 Ohm characteristic impedance)  
Switch open  
Output Voltage Transient  
-
4
7
mVp-p  
switch closed / switch open  
Note: As measured in ANADIGICS test fixture.  
Table 6: Logic Interface Specifications  
(T  
A
= 25 °C; VDD, VATTN = +5.0 VDC)  
PARAMETER  
MIN  
TYP  
MAX  
UNIT COMMENTS  
Attenuator Control Logic  
V
V
IN,  
LOW  
0
-
-
0.5  
5.5  
Bypasses atten. stage  
V
IN  
,
HIGH  
2.7  
Enables atten. stage  
Attenuator Control Impedance  
-
5 K  
-
Ohms  
Output Switch Control Logic  
V
V
IN,  
LOW  
0
-
-
1
Switch closed  
Swicth open  
V
IN  
,
HIGH  
2.8  
5.5  
Output Switch Control Impedance  
-
10 K  
-
Ohms  
Table 7: Attenuator Logic  
ATTENUATION (dB)  
0
L
L
L
L
4
H
L
L
L
8
L
H
L
L
12 16 20 24 28 32 36 40 44 48 52 56 60  
4 dB Logic Input (pin 16)  
8 dB Logic Input (pin 15)  
16 dB Logic Input (pin 14)  
32 dB Logic Input (pin 13)  
H
H
L
L
L
H
L
L
H
H
L
H
H
H
L
L
L
H
L
L
H
L
H
H
L
L
L
H
L
L
H
H
H
H
H
H
H
H
L
H
L
L
L
H
H
H
H
L
H
H
H
H
Notes: “L” = logic low, “H” = logic high  
Data Sheet - Rev 2.1  
03/2004  
6
ARA1400  
4 d B  
8 d B  
1 6 d B  
3 2 d B  
Figure 4: Test Circuit  
Data Sheet - Rev 2.1  
03/2004  
7
ARA1400  
APPLICATION INFORMATION  
Amplifier Enable / Disable  
Thermal Layout Considerations  
The ARA1400 includes two amplification stages that  
each can be shut down through external control pins  
The device package for the ARA1400 features a heat  
slug on the bottom of the package body. Use of the  
heat slug is an integral part of the device design.  
Soldering it to the ground plane of the PC board will  
ensure the lowest possible thermal resistance for  
the device, and will result in the longest MTF (mean  
time to failure.)  
V
REF1 and VREF2 (pins 5 and 18, respectively). By  
applying a typical bias of 1.75 Volts to these pins,  
the amplifiers are enabled. In order to fully disable  
an amplifier, its control pin requires a negative bias  
of -1.5 to -2.0 Volts.  
Output Switch Control  
A PC board layout that optimizes the benefits of the  
heat slug is shown in Figure 5. The via holes located  
under the body of the device must be plated through  
to a ground plane layer of metal, in order to provide  
sufficient thermal conductivity. The recommended  
solder mask outline is shown in Figure 6.  
A switch located at the output of Amplifier A2 in the  
ARA1400 provides isolation without having to  
disable the amplifiers. The switch is controled by  
the Tx logic input (pin 25).  
Amplifier Bias Current  
The ISET pins (11 and 27) set the bias current for the  
amplification stages. Grounding these pins results  
in the maximum possible current. By placing a  
resistor from the pin to ground, the current can be  
reduced. The recommended bias conditions use  
the configuration shown in the test circuit schematic  
in Figure 4.  
ESD Sensitivity  
Electrostatic discharges can cause permanent  
damage to these devices. Electrostatic charges  
accumulate on test equipment and the human body,  
and can discharge without detection. Proper  
precautions and handling are strongly  
recommended. Refer to the ANADIGICS application  
note on ESD precautions.  
0.025 BSC  
0.089  
0.014 TYP  
BODY OUTLINE  
(NOMINAL)  
0.025 MIN.  
0.163  
0.099  
0.070  
0.197  
(12X)0.020 TO 0.060 DIA.P  
0.060 TYP.  
PLATED THRU HOLES.  
0.400  
DIMENSIONS IN INCHES  
Figure 5: PC Board Layout  
Data Sheet - Rev 2.1  
03/2004  
8
ARA1400  
0.016 TYP.  
0.091  
0.0535  
0.025 TYP.  
0.163  
0.242  
0.085  
0.098  
0.025 BSC  
0.145  
DIMENSIONS IN INCHES  
Figure 6: Solder Mask Outline  
Data Sheet - Rev 2.1  
03/2004  
9
ARA1400  
PACKAGE OUTLINE  
Figure 7: S12 Package Outline - 28 Pin SSOP with Heat Slug  
Data Sheet - Rev 2.1  
03/2004  
10  
ARA1400  
COMPONENT PACKAGING  
Volume quantities of the ARA1400 are supplied on  
tape and reel. Each reel holds 3,500 pieces. Smaller  
quantities are available in plastic tubes of 50 pieces.  
Figure 8: Reel Dimensions  
Figure 9: Tape Dimensions  
Data Sheet - Rev 2.1  
03/2004  
11  
ARA1400  
ORDERING INFORMATION  
TEMPERATURE  
PACKAGE  
ORDER NUMBER  
ARA1400S12CTR  
ARA1400S12C  
COMPONENT PACKAGING  
3,500 piece tape and reel  
RANGE  
DESCRIPTION  
28 Pin SSOP  
with Heat Slug  
0 to 85 °C  
28 Pin SSOP  
with Heat Slug  
0 to 85 °C  
Plastic tubes (50 pieces per tube)  
ANADIGICS, Inc.  
141 Mount Bethel Road  
Warren, New Jersey 07059, U.S.A.  
Tel: +1 (908) 668-5000  
Fax: +1 (908) 668-5132  
URL: http://www.anadigics.com  
E-mail: Mktg@anadigics.com  
IMPORTANT NOTICE  
ANADIGICS, Inc. reserves the right to make changes to its products or to discontinue any product at any time without  
notice. The product specifications contained in Advanced Product Information sheets and Preliminary Data Sheets are  
subject to change prior to a product’s formal introduction. Information in Data Sheets have been carefully checked and are  
assumed to be reliable; however, ANADIGICS assumes no responsibilities for inaccuracies. ANADIGICS strongly urges  
customers to verify that the information they are using is current before placing orders.  
WARNING  
ANADIGICS products are not intended for use in life support appliances, devices or systems. Use of an ANADIGICS  
product in any such application without written consent is prohibited.  
Data Sheet - Rev 2.1  
03/2004  
12  

相关型号:

ARA1400S12

CATV Reverse Amplifier with step Attenuator
ANADIGICS

ARA1400S12C

Reverse Amplifier with Step Attenuator
ANADIGICS

ARA1400S12CTR

Reverse Amplifier with Step Attenuator
ANADIGICS

ARA2000

Address-Programmable Reverse Amplifier with Step Attenuator
ANADIGICS

ARA2000S12P1

Address-Programmable Reverse Amplifier with Step Attenuator
ANADIGICS

ARA2000S23

CATV Reverse Amplifier with step Attenuator
ANADIGICS

ARA2000S23P0

Analog Miscellaneous
ETC

ARA2000S23TR

Analog Miscellaneous
ETC

ARA2000_11

Address-Programmable Reverse Amplifier with Step Attenuator
ANADIGICS

ARA2001

CATV Reverse Amplifier with step Attenuator
ANADIGICS

ARA2001S23

CATV Reverse Amplifier with step Attenuator
ANADIGICS

ARA2001S23P0

Analog Miscellaneous
ETC