REVISIONS
LTR
DESCRIPTION
DATE (YR-MO-DA)
APPROVED
A
B
C
D
Changes in accordance with NOR 5962-R004-95.
Rewrite paragraphs 4.2.a.2. and 4.3.3.b.2 to add TC.
Added device types 10 and 11 for cage 88379. -sld
Update drawing paragraphs -sld
94-10-13
04-03-25
08-03-12
11-11-16
Kendall A. Cottongim
Raymond Monnin
Robert M. Heber
Charles F. Saffle
THE ORIGINAL FIRST SHEET OF THIS DRAWING HAS BEEN REPLACED.
REV
SHEET
REV
D
D
D
D
D
D
D
21
D
SHEET
15
16
17
18
19
20
REV STATUS
OF SHEETS
REV
SHEET
D
2
D
3
D
4
D
5
D
6
D
7
D
8
D
9
D
D
D
D
D
1
10
11
12
13
14
PMIC N/A
PREPARED BY
Steve Duncan
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
http://www.landandmaritime.dla.mil
STANDARD
MICROCIRCUIT
DRAWING
CHECKED BY
Michael C. Jones
THIS DRAWING IS
AVAILABLE
FOR USE BY ALL
DEPARTMENTS
APPROVED BY
Greg Lude
MICROCIRCUIT, HYBRID, DIGITAL, LOW
POWER, SINGLE CHANNEL,
DRIVER-RECEIVER
AND AGENCIES OF THE
DEPARTMENT OF
DEFENSE
DRAWING APPROVAL DATE
92-07-16
AMSC N/A
REVISION LEVEL
SIZE
A
CAGE CODE
67268
D
5962-91749
SHEET
1 OF 21
DSCC FORM 2233
APR 97
5962-E352-11
1. SCOPE
1.1 Scope. This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A
choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When
available, a choice of radiation hardness assurance levels are reflected in the PIN.
1.2 PIN. The PIN shall be as shown in the following example:
5962
-
91749
01
H
X
X
RHA
Federal
stock class
designator
\
Device
type
Device
class
Case
outline
(see 1.2.4)
Lead
finish
(see 1.2.5)
designator
(see 1.2.1)
(see 1.2.2)
designator
(see 1.2.3)
/
\/
Drawing number
1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA
levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device.
1.2.2 Device type(s). The device type(s) identify the circuit function as follows:
Device type
Generic number
NHI-1514
NHI-1513
BUS63102II
BUS63104II
3231
Circuit function
01
02
03
04
05
Single channel, driver-receiver (MIL-STD-1553 A and B), low power, receiver
standby high
Single channel, driver-receiver (universal transciever), low power, receiver
standby high
Single channel, driver-receiver (universal transciever), low power, receiver
standby high
Single channel, driver-receiver (MIL-STD-1553 A and B), low power, receiver
standby high
Single channel, driver-receiver (MIL-STD-1553 A and B), low power, receiver
standby high
06 and 07
3232
Single channel, driver-receiver (universal transciever), low power, receiver
standby high
08 1/
09 1/
10
4407
Single channel, driver-receiver (MIL-STD-1553 A and B), low power, receiver
standby high
4404
Single channel, driver-receiver (universal transciever), low power, receiver
standby high
4407N
Single channel, driver-receiver (MIL-STD-1553 A and B), low power, receiver
standby high
11
4404N
Single channel, driver-receiver (universal transciever), low power, receiver
standby high
1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level.
All levels are defined by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K,
and E) or QML Listing (Class G and D). The product assurance levels are as follows:
Device class
K
Device performance documentation
Highest reliability class available. This level is intended for use in space
applications.
H
G
Standard military quality class level. This level is intended for use in applications
where non-space high reliability devices are required.
Reduced testing version of the standard military quality class. This level uses the
Class H screening and In-Process Inspections with a possible limited temperature
range, manufacturer specified incoming flow, and the manufacturer guarantees (but
may not test) periodic and conformance inspections (Group A, B, C, and D).
1/ Device types 08 and 09 are inactive for new design, use device types 10 and 11 for replacements.
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
2
DSCC FORM 2234
APR 97
E
D
Designates devices which are based upon one of the other classes (K, H, or G)
with exception(s) taken to the requirements of that class. These exception(s) must
be specified in the device acquisition document; therefore the acquisition document
should be reviewed to ensure that the exception(s) taken will not adversely affect
system performance.
Manufacturer specified quality class. Quality level is defined by the manufacturers
internal, QML certified flow. This product may have a limited temperature range.
1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows:
Outline letter
Descriptive designator
Terminals
Package style
T
U
X
Y
Z
See figure 1
See figure 1
See figure 1
See figure 1
See figure 1
24
24
24
24
24
Hybrid package
Flat package
Hybrid package
Flat package
Hybrid package
1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534.
1.3 Absolute maximum ratings. 2/
Supply voltage range:
VCC ..........................................................................................
VEE ..........................................................................................
VCCL..........................................................................................
Logic input voltage range ...........................................................
Receiver differential voltage ......................................................
Receiver common mode voltage range.......................................
Driver peak output current...........................................................
Lead temperature (soldering, 10 seconds)..................................
Storage temperature range .........................................................
Junction temperature (TJ) ...........................................................
Power dissipation (PD) total hybrid:
-0.3 V dc to +18 V dc
+0.3 V dc to -18 V dc
-0.3 V dc to +7 V dc
-0.3 V dc to +5.5 V dc
40 Vp-p
-10 V dc to +10 V dc
±300 mA
+300°C
-65°C to +150°C
+160°C
100 percent duty cycle (TC = +125°C):
Device types 01, 05, 06, and 08...........................................
Device types 02, 07, 09, 10 and 11......................................
Device types 03 and 04........................................................
Power dissipation (PD) hottest die:
3.0 W
3.24 W
3.28 W
100 percent duty cycle:
Device types 01, 04, 08, and 09...........................................
Device types 02 and 03........................................................
Device types 05, 06, and 07.................................................
Device types 10 and 11(single die) ......................................
Standby mode:
484 mW
545 mW
2.2 W
3.25 W
Device types 01, 02, 03, 04, 08, and 09...............................
Device types 05, 06, and 07.................................................
Device types 10 and 11(single die) ......................................
Derates to zero
750 mW
540 mW
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
3
DSCC FORM 2234
APR 97
1.3 Absolute maximum ratings - continued. 2/
Thermal resistance:
Junction-to-case (θJC) hottest die:
Device types 01 and 02 .......................................................
Device types 03, 04, 08, and 09 ..........................................
Device types 05, 06, and 07 ...............................................
Device types 10 and 11(single die) ......................................
Case to ambient:
38°C/W
58°C/W
6.5°C/W
5°C/W
Device types 01, 02, 03, 04, 08, 09, 10, and 11 ..................
Device types 05, 06, and 07.................................................
Thermal resistance, junction-to-case temperature rise for the
hottest die at 100 percent duty cycle:
21°C/W
20°C/W
Device type 01......................................................................
Device type 02......................................................................
Device type 03......................................................................
Device type 04......................................................................
Device types 05, 06, and 07.................................................
Device type 08......................................................................
Device type 09......................................................................
Device types 10 and 11(single die) ......................................
19°C/W
21°C/W
47.9°C/W
42.6°C/W
14.3°C/W
28°C/W
31.6°C/W
16.25°C/W
1.4 Recommended operating conditions.
Supply voltage range:
VCC...........................................................................................
+11.4 V dc to +15.75 V dc
VEE
:
Device types 01-05, 07-09, 10, and 11.................................
Device type 06......................................................................
VCCL..........................................................................................
Logic input voltage range ...........................................................
Receiver differential voltage ......................................................
Receiver common mode voltage range.......................................
Driver peak output current:
-11.4 V dc to -15.75 V dc
-11.75 V dc to -12.75 V dc
+4.5 V dc to +5.5 V dc
0 V dc to +5.0 V dc
40 Vp-p
-10 V dc to +10 V dc
Device types 01, 02, 08, and 09 .............................................
Device types 03 and 04 ..........................................................
Device types 05, 06, 07, 10, and 11 .......................................
Maximum serial data rate............................................................
Case operating temperature range (TC) ......................................
±180 mA
±200 mA
±100 mA
1.0 MHz
-55°C to +125°C
2. APPLICABLE DOCUMENTS
2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part
of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the
solicitation or contract.
DEPARTMENT OF DEFENSE SPECIFICATION
MIL-PRF-38534 - Hybrid Microcircuits, General Specification for.
2/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Extended operation at the
maximum levels may degrade performance and affect reliability.
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
4
DSCC FORM 2234
APR 97
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-883 - Test Method Standard Microcircuits.
MIL-STD-1835 - Interface Standard for Electronic Component Case Outlines.
DEPARTMENT OF DEFENSE HANDBOOKS
MIL-HDBK-103 - List of Standard Microcircuit Drawings.
MIL-HDBK-780 - Standard Microcircuit Drawings.
(Copies of these documents are available online at https://assist.daps.dla.mil/quicksearch/ or from the Standardization
Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text
of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
3. REQUIREMENTS
3.1 Item requirements. The individual item performance requirements for device classes D, E, G, H, and K shall be in
accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 shall include the performance of all tests herein or as
designated in the device manufacturer's Quality Management (QM) plan or as designated for the applicable device class. The
manufacturer may eliminate, modify or optimize the tests and inspections herein, however the performance requirements as
defined in MIL-PRF-38534 shall be met for the applicable device class. In addition, the modification in the QM plan shall not
affect the form, fit, or function of the device for the applicable device class.
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified
in MIL-PRF-38534 and herein.
3.2.1 Case outline(s). The case outline(s) shall be in accordance with 1.2.2 herein and figure 1.
3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2.
3.2.3 Test circuit. The test circuit shall be as specified on figure 3.
3.2.4 Timing waveforms. The timing waveforms shall be as specified on figure 4.
3.2.5 Coupling diagram. The coupling diagram shall be as specified on figure 5.
3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are
as specified in table I and shall apply over the full specified operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical
tests for each subgroup are defined in table I.
3.5 Marking of device(s). Marking of device(s) shall be in accordance with MIL-PRF-38534. The device shall be marked with
the PIN listed in 1.2 herein. In addition, the manufacturer's vendor similar PIN may also be marked.
3.6 Data. In addition to the general performance requirements of MIL-PRF-38534, the manufacturer of the device described
herein shall maintain the electrical test data (variables format) from the initial quality conformance inspection group A lot sample,
for each device type listed herein. Also, the data should include a summary of all parameters manually tested, and for those
which, if any, are guaranteed. This data shall be maintained under document revision level control by the manufacturer and be
made available to the preparing activity (DLA Land and Maritime - VA) upon request.
3.7 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to supply to this
drawing. The certificate of compliance (original copy) submitted to DLA Land and Maritime - VA shall affirm that the
manufacturer's product meets the performance requirements of MIL-PRF-38534 and herein.
3.8 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38534 shall be provided with each lot of
microcircuits delivered to this drawing.
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
5
DSCC FORM 2234
APR 97
4. VERIFICATION
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38534 or as
modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan shall not affect the form,
fit, or function as described herein.
4.2 Screening. Screening shall be in accordance with MIL-PRF-38534. The following additional criteria shall apply:
a. Burn-in test, method 1015 of MIL-STD-883.
(1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to either DLA Land and Maritime - VA or the acquiring activity upon request.
Also, the test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance
with the intent specified in method 1015 of MIL-STD-883.
(2) T as specified in accordance with table I of method 1015 of MIL-STD-883.
A
b. Interim and final electrical test parameters shall be as specified in table II herein, except interim electrical parameter
tests prior to burn-in are optional at the discretion of the manufacturer.
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
6
DSCC FORM 2234
APR 97
TABLE I. Electrical performance characteristics.
Test
Symbol
Conditions 1/
Group A
subgroups
Device
type
Limits
Unit
-55°C ≤ T ≤ +125°C
C
unless otherwise specified
Min
Max
RECEIVER
Output low voltage
VOL
IOL = 10 mA
IOL = 4 mA
1,2,3
01-07
08-11
0.5
0.5
V
V
Output high voltage
VOH
VI
IOH = -0.4 mA
1,2,3
4,5,6
All
All
2.5
Differential Input
voltage level
40
Vp-p
Differential Input
impedance
ZIN
1 MHz sinewave 2/
4,5,6
01,02,08,
09,10,11
10
4
kΩ
03,04,05,
06,07
Common mode input
voltage range
VICRM
1 MHz sinewave, see
figure 3.
4,5,6
All
All
10
Vp-p
Input capacitance
Threshold voltage
CIN
1 MHz sine wave 2/
3/ 4/ 5/
4
5
pF
VTH
4,5,6
01,02,08,
09,10,11
0.6
1.05
Vp-p
03,04
05,06,07
All
0.5
0.4
1.2
1.1
450
Receiver delay
tDR
Input zero crossing to DATA
or DATA, see figure 3 2/
4,5,6
1,2,3
ns
V
RECEIVER STROBE
Input low voltage
VSIL
All
All
0.7
Input high voltage
Input low current
VSIH
ISIL
1,2,3
1,2,3
2
V
VSIL = 0.4 V
01,02,
08,09,10,
11
-0.4
mA
03,04
-0.720
-4
05,06,07
See footnotes at end of table.
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
7
DSCC FORM 2234
APR 97
TABLE I. Electrical performance characteristics - Continued.
Test
Symbol
Conditions 1/
Group A
subgroups
Device
type
Limits
Unit
-55°C ≤ T ≤ +125°C
C
unless otherwise specified
Min
Max
80
RECEIVER STROBE - Continued.
Input high current ISIH
VSIH = 2.7 V
1,2,3
01,02,03,
04,08,09
µA
05,06,07
10,11
400
40
Strobe delay
tDS
Turn-on or turn-off,
see figure 4 2/
9,10,11
01,02,03,
04
200
ns
05-11
150
0.7
TRANSMITTER
Input low voltage
Input high voltage
Input low current
VIL
VIH
IIL
1,2,3
1,2,3
1,2,3
All
All
V
2.0
V
VIL = 0.4 V
01,02,10,
11
-0.4
mA
03,04,08,
09
-0.720
-1.1
05,06,07
Input high current
Differential output
IIH
VIH = 2.7 V
1,2,3
01,02,03,
04,08,09,
10,11
40
µA
05,06,07
All
100
9.0
VO
1,2,3
4,5,6
6.0
24
Vp-p
35Ω load 4/
36
10
140Ω load 2/ 6/
Inhibited, 35Ω load 4/
Differential output noise VON
All
All
mV rms
40
140Ω load 2/ 6/
Differential output
impedance
ZOUT
1 MHz sinewave,
(transmitter off) 2/
4,5,6
10
kΩ
See footnotes at end of table.
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
8
DSCC FORM 2234
APR 97
TABLE I. Electrical performance characteristics - Continued.
Test
Symbol
Conditions 1/
Group A
subgroups
Device
type
Limits
Min
Unit
-55°C ≤ T ≤ +125°C
C
unless otherwise specified
Max
5
TRANSMITTER - Continued.
Output capacitance
COUT
1 MHz sine wave 2/
4
All
All
pF
Differential output offset VOS
voltage
4,5,6
-90
+90
mV pk
dB
35Ω load
-360
+360
140Ω load 2/ 6/ 7/
Receiver filter response FILTER
f = 2 MHz 2/
4,5,6
All
-4.0
f = 4 MHz 2/
-13.0
Rise time
tr
9,10,11
9,10,11
9,10,11
01,04,08,10
100
220
300
300
ns
ns
ns
35Ω load, see figure 4
02,03,05,06,
07,09,11
Fall time
tf
01,04,08,10
100
220
300
300
35Ω load, see figure 4
02,03,05,06,
07,09,11
Transmitter delay
tdt
Transmitter-in to transmitter-
out, see figure 4 2/
All
550
TRANSMITTER INHIBIT
Input low voltage
VIIL
VIIH
IILL
1,2,3
1,2,3
1,2,3
All
All
0.7
V
Input high voltage
Input low current
2.0
V
VSIL = 0.4 V
01,02,08,09,
10,11
-0.4
mA
03,04
-0.720
-0.8
05,06,07
Input high current
IIIH
VSIH = 2.7 V
1,2,3
01,02,03,04,
08,09,10,11
40
50
µA
05,06,07
See footnotes at end of table.
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
9
DSCC FORM 2234
APR 97
TABLE I. Electrical performance characteristics - Continued.
Test
Symbol
Conditions 1/
Group A
subgroups
Device
type
Limits
Unit
-55°C ≤ T ≤ +125°C
C
unless otherwise specified
Min
Max
450
TRANSMITTER INHIBIT - Continued.
Transmitter inhibit
delay (high)
tDI-H
0-1 inhibited output,
see figure 4 2/
9,10,11
9,10,11
01,02,04-
07,08-11
ns
03
700
450
Transmitter inhibit
delay (low)
tDI-L
1-0 active output,
see figure 4 2/
01,02,04-
07,08-11
ns
03
700
50
POWER SUPPLY
+Supply (VCC
)
ICC-SB
(Standby mode)
1,2,3
01,02,08,
09
mA
03,04
05,06,07
10,11
30
65
10
40
65
35
20
-Supply (VEE
)
IEE-SB
(Standby mode)
(Standby mode)
1,2,3
1,2,3
01,02
mA
mA
03-09
10,11
+5 V supply (VCCL
)
ICC1-SB
01,02,05,
06,07
03,04,08,
09
45
10,11
30
+Supply (VCC
)
ICC-50
50 percent duty cycle
4,5,6
01,02,08,
09
100
mA
03,04
05,06,07
10,11
114
150
60
See footnotes at end of table.
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
10
DSCC FORM 2234
APR 97
TABLE I. Electrical performance characteristics - Continued.
Test
Symbol
Conditions 1/
Group A
subgroups
Device
type
Limits
Unit
-55°C ≤ T ≤ +125°C
C
unless otherwise specified
Min
Max
110
POWER SUPPLY - Continued.
-Supply (VEE
)
IEE-50
50 percent duty cycle
4,5,6
4,5,6
4,5,6
01,02,08,
09
mA
03,04
05,06,07
10,11
135
150
80
+Supply (VCC
)
ICC-100
100 percent duty cycle
01,02,08,
09
165
mA
03,04
05,06,07
10,11
180
250
120
165
-Supply (VEE
)
IEE-100
100 percent duty cycle
01,02,08,
09
mA
03,04
05,06,07
10,11
195
250
140
1/ Unless otherwise specified, supply voltage ranges are as follows:
(+14.9 V dc ≤ VCC ≤ +15.1 V dc), (-14.9 V dc ≤ VEE ≤ -15.1 V dc), (+4.9 V dc ≤ VCCL ≤ +5.1 V dc).
2/ Parameter shall be tested as part of initial characterization and after design and process changes. Parameter shall be
guaranteed to the limits specified in table I.
3/ Threshold determined by the first missing word of a 33 word transmission to a Harris HD-15530 CMOS Manchester
encoder-decoder.
4/ Measured at point A A' of figure 5.
5/ Assumed the internal threshold option is used.
6/ Measured at point B B' of figure 5.
7/ Offset is measured 2.5 µs after the mid-bit zero crossing of the last parity bit of a 600 µs transmission cycle of contiguous
words (no dead time in between words).
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
11
DSCC FORM 2234
APR 97
Case outline T.
(Device types 08 and 09)
Inches
.002
.003
.005
.009
.017
.025
mm
Inches
.080
.100
.167
.400
1.27
mm
2.03
2.54
4.24
10.16
32.3
0.05
0.08
0.13
0.23
0.43
0.64
FIGURE 1. Case outline(s).
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
12
DSCC FORM 2234
APR 97
Case outline U.
(Device types 05, 06, and 07)
Inches
.002
.003
.005
.009
.017
mm
Inches
.070
.100
.167
.400
1.27
mm
1.78
2.54
4.24
10.16
32.3
0.05
0.08
0.13
0.23
0.43
FIGURE 1. Case outline(s) - Continued.
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
13
DSCC FORM 2234
APR 97
Case outline X.
(Device types 01, 02, 03, 04, 08, 09, 10, and 11)
Inches
.002
.018
.100
.175
mm
Inches
.240
1.100
1.27
mm
6.10
27.94
32.3
0.05
0.46
2.54
4.44
NOTE: For device type 03 only, case outline X, the package height is .180 inches (4.51 mm) maximum.
FIGURE 1. Case outline(s) - Continued.
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
14
DSCC FORM 2234
APR 97
Case outline Y.
(Device types 01, 02, 03, 04, 08, 09, 10, and 11)
Inches
.002
.003
.005
.009
.015
.017
mm
Inches
.080
.100
.200
.400
1.27
mm
2.03
2.54
5.08
10.16
32.3
0.05
0.08
0.13
0.23
0.41
0.43
FIGURE 1. Case outline(s) - Continued.
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
15
DSCC FORM 2234
APR 97
Case outline Z.
(Device types 05, 06, and 07)
Inches
.002
.018
.100
.167
mm
Inches
.275
1.100
1.27
mm
6.98
27.94
32.3
0.05
0.46
2.54
4.24
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for general information only.
3. Unless otherwise specified, tolerance for three places shall be .005 (0.13 mm).
FIGURE 1. Case outline(s) - Continued.
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
16
DSCC FORM 2234
APR 97
Device type
All
Case outline
Case outlines T, U, X, Y, and Z.
Terminal number
Terminal symbol
TX DATA OUT
TX DATA OUT
GND C
Terminal number
Terminal symbol
VCC RX
1
2
13
14
15
16
NC
3
RX DATA IN
RX DATA IN
GND A
4
VCC TX
5
EXTERNAL DATA THRESHOLD
INTERNAL DATA THRESHOLD
RX DATA OUT
17
18
19
20
21
22
23
24
6
CASE GND
VEE RX
7
8
STROBE
VCCL
9
GND B
TX INHIBIT
TX DATA IN
TX DATA IN
VEE TX
10
11
12
RX DATA OUT
INTERNAL DATA THRESHOLD
EXTERNAL DATA THRESHOLD
FIGURE 2. Terminal connections.
NOTE: Observe no transmission of data at RX DATA and RX DATA.
FIGURE 3. Test circuit.
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
17
DSCC FORM 2234
APR 97
FIGURE 4. Timing waveforms.
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
18
DSCC FORM 2234
APR 97
FIGURE 5. Coupling diagram.
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
19
DSCC FORM 2234
APR 97
TABLE II. Electrical test requirements.
MIL-PRF-38534 test requirements
Subgroups
(in accordance with
MIL-PRF-38534, group A
test table)
Interim electrical parameters
Final electrical parameters
Group A test requirements
1
1*,2,3,4,5,6,9,10,11
1,2,3,4,5,6,9,10,11
1,2,3
Group C end-point electrical
parameters
End-point electrical parameters
for radiation hardness assurance
(RHA) devices
Not applicable
* PDA applies to subgroup 1.
4.3 Conformance and periodic inspections. Conformance inspection (CI) and periodic inspection (PI) shall be in accordance
with MIL-PRF-38534 and as specified herein.
4.3.1 Group A inspection (CI). Group A inspection shall be in accordance with MIL-PRF-38534 and as follows:
a. Tests shall be as specified in table II herein.
b. Subgroups 7 and 8 shall be omitted.
4.3.2 Group B inspection (PI). Group B inspection shall be in accordance with MIL-PRF-38534.
4.3.3 Group C inspection (PI). Group C inspection shall be in accordance with MIL-PRF-38534 and as follows:
a. End-point electrical parameters shall be as specified in table II herein.
b. Steady-state life test, method 1005 of MIL-STD-883.
(1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to either DLA Land and Maritime - VA or the acquiring activity upon request.
Also, the test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance
with the intent specified in method 1005 of MIL-STD-883.
(2) T as specified in accordance with table I of method 1015 of MIL-STD-883.
A
(3) Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
4.3.4 Group D inspection (PI). Group D inspection shall be in accordance with MIL-PRF-38534.
4.3.5 Radiation Hardness Assurance (RHA) inspection. RHA inspection is not currently applicable to this drawing.
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
20
DSCC FORM 2234
APR 97
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38534.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications
(original equipment), design applications, and logistics purposes.
6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-
prepared specification or drawing.
6.3 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated as specified in MIL-PRF-
38534.
6.4 Record of users. Military and industrial users shall inform DLA Land and Maritime when a system application requires
configuration control and the applicable SMD. DLA Land and Maritime will maintain a record of users and this list will be used
for coordination and distribution of changes to the drawings. Users of drawings covering microelectronic devices
(FSC 5962) should contact DLA Land and Maritime - VA, telephone (614) 692-0544.
6.5 Comments. Comments on this drawing should be directed to DLA Land and Maritime - VA, Columbus, Ohio 43218-3990,
or telephone (614) 692-1081.
6.6 Sources of supply. Sources of supply are listed in MIL-HDBK-103 and QML-38534. The vendors listed in MIL-HDBK-103
and QML-38534 have submitted a certificate of compliance (see 3.7 herein) to DLA Land and Maritime - VA and have agreed to
this drawing.
SIZE
STANDARD
5962-91749
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
D
21
DSCC FORM 2234
APR 97
STANDARD MICROCIRCUIT DRAWING BULLETIN
DATE: 11-11-16
Approved sources of supply for SMD 5962-91749 are listed below for immediate acquisition information only and
shall be added to MIL-HDBK-103 and QML-38534 during the next revisions. MIL-HDBK-103 and QML-38534 will be
revised to include the addition or deletion of sources. The vendors listed below have agreed to this drawing and a
certificate of compliance has been submitted to and accepted by DLA Land and Maritime - VA. This information
bulletin is superseded by the next dated revisions of MIL-HDBK-103 and QML-38534. DLA Land and Maritime
maintains an online database of all current sources of supply at http://www.landandmaritime.dla.mil/Programs/Smcr/
Standard
microcircuit drawing
PIN 1/
Vendor
CAGE
number
Vendor
similar
PIN 2/
5962-9174901HXA
5962-9174901HXC
3/
3/
NHI-1514
NHI-1514
5962-9174901HYA
5962-9174901HYC
3/
3/
NHI-1514FP
NHI-1514FP
5962-9174902HXA
5962-9174902HXC
3/
3/
NHI-1513
NHI-1513
5962-9174902HYA
5962-9174902HYC
3/
3/
NHI-1513FP
NHI-1513FP
5962-9174903HXA
5962-9174903HXA
5962-9174903HXC
5962-9174903HXC
3/
3/
3/
3/
BUS-63102II-150
BUS-63102II-140
BUS-63102II-130
BUS-63102II-110
5962-9174903HYA
5962-9174904HXA
5962-9174904HYA
3/
3/
3/
BUS-63102II
BUS-63104II
BUS-63104II
5962-9174905HUA
5962-9174905HZA
3/
3/
MR3231MF5
MR3231MP5
5962-9174906HUA
5962-9174906HZA
3/
3/
MR3232MF2
MR3232MP2
5962-9174907HUA
5962-9174907HZA
3/
3/
MR3232MF5
MR3232MP5
5962-9174908HTA
5962-9174908HTC
3/
3/
ARX4407LPFP
ARX4407LPFP
5962-9174908HTA
5962-9174908HTC
3/
3/
NHI-1514FP/883
NHI-1514FP/883
See footnotes at end of table.
1 of 3
STANDARD MICROCIRCUIT DRAWING BULLETIN - Continued.
DATE: 11-11-16
Standard
microcircuit drawing
PIN 1/
Vendor
CAGE
number
Vendor
similar
PIN 2/
5962-9174908HXA
5962-9174908HXC
3/
3/
NHI-1514/883
NHI-1514/883
5962-9174908HXA
5962-9174908HXC
88739
88739
ARX4407-001-2
ARX4407-001-1
5962-9174908HYA
5962-9174908HYC
3/
3/
NHI-1514FP/883
NHI-1514FP/883
5962-9174908HYA
5962-9174908HYC
88379
88379
ARX4407-201-2
ARX4407-201-1
5962-9174909HTA
5962-9174909HTC
3/
3/
NHI-1513FP/883
NHI-1513FP/883
5962-9174909HTA
5962-9174909HTC
3/
3/
ARX4404LPFP
ARX4404LPFP
5962-9174909HXA
5962-9174909HXC
3/
3/
NHI-1513/883
NHI-1513/883
5962-9174909HXA
5962-9174909HXC
88379
88379
ARX4404-001-2
ARX4404-001-1
5962-9174909HYA
5962-9174909HYC
3/
3/
NHI-1513FP/883
NHI-1513FP/883
5962-9174909HYA
5962-9174909HYC
88379
88379
ARX4404-201-2
ARX4404-201-1
5962-9174910HXA
5962-9174910HXC
88379
88379
ACT4407N-001-2
ACT4407N-001-1
5962-9174910HYA
5962-9174910HYC
88379
88379
ACT4407N-201-2
ACT4407N-201-1
5962-9174911HXA
5962-9174911HXC
88379
88379
ACT4404N-001-2
ACT4404N-001-1
5962-9174911HYA
5962-9174911HYC
88379
88379
ACT4404N-201-2
ACT4404N-201-1
1/ The lead finish shown for each PIN representing a hermetic package is the most readily available from the
manufacturer listed for that part. If the desired lead finish is not listed contact the Vendor to determine its
availability.
2/ Caution. Do not use this number for item acquisition. Items acquired to this number may not satisfy the
performance requirements of this drawing.
3/ Not available from an approved source.
2 of 3
STANDARD MICROCIRCUIT DRAWING BULLETIN - Continued.
DATE: 11-11-16
Vendor CAGE
number
Vendor name
and address
88379
Aeroflex Plainview Incorporated
(Aeroflex Microelectronics Solutions)
35 South Service Road
Plainview, NY 11803-4101
The information contained herein is disseminated for convenience only and the
Government assumes no liability whatsoever for any inaccuracies in the
information bulletin.
3 of 3
相关型号:
©2020 ICPDF网 联系我们和版权申明