BR240_16 [ARCH]
Input under Voltage Protection;型号: | BR240_16 |
厂家: | ARCH ELECTRONICS CORP. |
描述: | Input under Voltage Protection |
文件: | 总3页 (文件大小:274K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
VER : A_1
update : 2015.03.16
DC-DC Brick
BR240 SERIES
240 Watts
DESCRIPTION
KEY FEATURES
Input under Voltage Protection
Over Current Protection (Hiccup Mode)
Short Circuit Protection (Hiccup Mode)
Over Voltage Protection (Hiccup Mode)
Over Temperature Protection (Self-recovery)
Remote ON/OFF Control
The BR240 series DC-DC converter are high-efficiency and power density 1/8
brick isolation modules, rating output voltage 12V, output power 240W. This
series provide the standard 1/8 brick version and the PMBus compatible
version. The latter is compatible with the PMBus1.1 communication protocol,
backward compatible with the I²C/SMBus protocol, and providing Pre-bias,
output monitoring and current sharing functions. The BR240 series conform to
the RoHS6 requirement.
Activates Hardware and Software *
Digitally Adjusts the Voltage *
PMBus Revision 1.1 compliant *
Secondary ON/OFF Control *
Pre-Bias Function *
UL60950-1 and CSA C22.2 No. 60950-1-07
Meet UL94V-0 Flammability Requirements
Rohs6 Compliant
Size: 2.3 x 0.9 x 0.5 Inches
3-Years Product Warranty
*BR240-12S without this function
ELECTRICAL SPECIFICATIONS
Conditions: TA = 25°C (77°F), Airflow = 1 m/s (200 LFM), Vin = 48 V, unless otherwise notes.
Model No.
BR240-12S
BR240-12S-P
Max Output Wattage (W)
240W
Voltage (V.DC.)
48V (36~75V)
Input
Current (A) (max)
No-Load Loss (W) (typ.)
Voltage (V.DC.)
10A (Vin= 36 - 75 V; Iout = 20 A)
9.6W (Vin= 36 - 75 V; Iout = 0 A)
12V (Vin= 48 V; Iout = 10 A)
Voltage Range (V.DC.)
11.64~12.36V
(Vin= 40 - 75 V; Adjust the voltage by PMBus)
11.64~12.36V (Vin= 40 - 75 V)
10.8~12.36V
(Vin= 36 - 40 V; Adjust the voltage by PMBus)
10.8~12.36V (Vin= 36 - 40 V)
20A
Current (A) (max.)
Output
Line Regulation (LL-HL) (typ.)
Load Regulation (0-100%) (typ.)
Ripple & Noise (peak to peak) (typ.)
Efficiency
0.2% (Vin= 40 - 75 V; Iout = 20 A) / 10% (Vin= 36 - 40 V; Iout = 20 A
3% (Vin = 48 V; Iout = 0 – 20 A)
200 mV (Oscilloscope Bandwidth:20 MHz)
100% Load:95% (Iout = 20 A)
(Vin = 48 V; TA=25°C (77°F)) (typ.)
50% Load:94.5% (Iout = 10 A)
30% Load:92.0% (Iout = 6 A)
Over Power Protection
Hiccup mode
Over Current Protection
Over Voltage Protection
Short Circuit Protection (max.)
Over Temperature Protection
Hiccup mode
15V (14~16V) (Hiccup mode)
5 Arms (Hiccup mode)
Threshold:130°C (typ.) / Hysteresis:15°C (typ.)
Protection
Self-recovery (The values are obtained by measuring the temperature of the hottest power
component on the top surface of the converter.)
Isolation
Voltage (V.DC.)
Operating Temperature
Storage Temperature
Temperature Coefficient
Humidity
1500 VDC (Functional Isolation)
-40°C…+85°C
-55°C…+125°C
0.02 % Vout / °C (TA = -40°C to +85°C (-40°F to +185°F ))
95% RH
Environment
MTBF
1.5 Million Hours
(Telcordia SR332; 80% load; TA = 40°C (104°F)
Safety
EMC
Agency Approvals
CE, UL, TUV
UL60950-1 and CSA C22.2 No. 60950-1-07
EMI (Conducted & Radiated Emission)
Dimension (L x W x H)
Weight
2.3 x 0.9 x 0.5 Inches ( 58.4 x 22.8 x 12.7 mm ) Tolerance 0.5 mm
40 g
Physical
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-
VER : A_1
update : 2015.03.16
DC-DC Brick
BR240 SERIES
240 Watts
ELECTRICAL SPECIFICATIONS
Conditions: TA = 25°C (77°F), Airflow = 1 m/s (200 LFM), Vin = 48 V, unless otherwise notes.
Model No.
Other
BR240-12S
BR240-12S-P
Low level (V.DC.)
High level (V.DC.)
Low level (mA) (max.)
-0.7~1.2V (The primary low electric level is effective)
On/Off Voltage
2.8~8V
1mA
(The primary low electric level is effective)
On/Off Current
Primary On/Off Voltage
0.7~1.2V
(The low electric level is effective)
2.8~8V
─
Low level (V.DC.)
─
─
─
High level (V.DC.)
Low level (mA) (max.)
Low level (V.DC.)
(The low electric level is effective)
Primary On/Off Current
Secondary CTL Voltage
1mA
0~0.8V
(The High Electric Level is Effective)
3.3~3.6V
(The High Electric Level is Effective)
─
High level (V.DC.) (max.)
Logic Input and Output Pins in the Communications Port
Logic Input Low level (V.DC.) (max.)
Logic Input High Level (V.DC.) (max.)
Logic Output Low Level (V.DC.) (max.)
Logic Output High Level (V.DC.) (max.)
PMBus Setting-up Time (ns.) (min.)
─
─
─
─
─
─
1.1V
3.6V
0.25V
3.6V
100
PMBus Holding Time (ns.) (min.)
0
PMBus Detected Precision (Vin=36 - 75 V; Iout=0 - 20 A;TA = -40°C to +85°C (-40°F to +185°F ))
─
─
─
─
Input Voltage Detected Precision (V.DC.)
Output Voltage Detected Precision (V.DC.)
Output Current Detected Precision (A)
Temperature Detected Precision (°C)
1V
0.2V
1A
5°C
NOTE
1. During the test of input reflected ripple current, the input terminal must be connected to a 12 uH inductor and a 220 uF electrolytic capacitor.
2. Point B, which is for testing the output voltage ripple, is 25 mm (0.98 in.) away from the Vout(+) pin.
DERATING
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
VER : A_1
update : 2015.03.16
DC-DC Brick
BR240 SERIES
240 Watts
MECHANICAL DIMENSION
PIN#
Single
+DC IN
1
2
ON / OFF CTL
-DC IN
3
4
-DC OUT
+DC OUT
SGND
5
6
7
SA0
8
PMBus_ALT
SA1
9
10
11
12
13
PMBus_CTL
ISHARE
PMBus_SCL
PMBus_SDA
Note
1. All dimensions in mm [in.]
Tolerances: x.x ± 0.5 mm [x.xx ± 0.02 in.]
x.xx± 0.25 mm [x.xxx ± 0.010 in.]
2. Pin 1-3 are 1.00 ± 0.05 mm [0.040 ± 0.002 in.] diameter with 2.00 ± 0.10 mm
[0.080 ± 0.004 in.] diameter standoff shoulders.
Pin4 and pin5 are 1.50 ± 0.05 mm [0.060 ± 0.002 in.] diameter with 2.50 ± 0.10
mm [0.098 ± 0.004 in.] diameter standoff shoulders.
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-3-
相关型号:
BR246-1000A1-48V
Power/Signal Relay, DPDT, Momentary, 0.048A (Coil), 48VDC (Coil), 2304mW (Coil), 10A (Contact), 28VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
MICROSEMI
BR246-1000A1-48V-032L
Electromechanical Relay, DPDT, 59VDC (Coil), 10A (Contact), 28VDC (Contact), Random, AC/DC Output
MICROSEMI
BR246-1000A1-48V-032M
Electromechanical Relay, DPDT, 59VDC (Coil), 10A (Contact), 28VDC (Contact), Random, AC/DC Output
MICROSEMI
BR246-1000A2-48V
Power/Signal Relay, DPDT, Momentary, 0.048A (Coil), 48VDC (Coil), 2304mW (Coil), 10A (Contact), 28VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
MICROSEMI
BR246-1000A2-48V-035L
Electromechanical Relay, DPDT, 59VDC (Coil), 10A (Contact), 28VDC (Contact), Random, AC/DC Output
MICROSEMI
BR246-1000A2-48V-035M
Electromechanical Relay, DPDT, 59VDC (Coil), 10A (Contact), 28VDC (Contact), Random, AC/DC Output
MICROSEMI
BR246-1000A3-48V
Power/Signal Relay, 2 Form C, DPDT, Momentary, 0.048A (Coil), 48VDC (Coil), 2304mW (Coil), 10A (Contact), 28VDC (Contact), DC Input, Random, AC/DC Output, Through Hole-Straight Mount,
MICROSEMI
BR246-1000B1-48V
Power/Signal Relay, DPDT, Momentary, 0.048A (Coil), 48VDC (Coil), 2304mW (Coil), 10A (Contact), 28VDC (Contact), DC Input, AC/DC Output, Panel Mount,
MICROSEMI
BR246-1000B1-48V-031L
Electromechanical Relay, DPDT, 59VDC (Coil), 10A (Contact), 28VDC (Contact), Random, AC/DC Output
MICROSEMI
BR246-1000B1-48V-031M
Electromechanical Relay, DPDT, 59VDC (Coil), 10A (Contact), 28VDC (Contact), Random, AC/DC Output
MICROSEMI
©2020 ICPDF网 联系我们和版权申明