BR240_16 [ARCH]

Input under Voltage Protection;
BR240_16
型号: BR240_16
厂家: ARCH ELECTRONICS CORP.    ARCH ELECTRONICS CORP.
描述:

Input under Voltage Protection

文件: 总3页 (文件大小:274K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
VER : A_1  
update : 2015.03.16  
DC-DC Brick  
BR240 SERIES  
240 Watts  
DESCRIPTION  
KEY FEATURES  
Input under Voltage Protection  
Over Current Protection (Hiccup Mode)  
Short Circuit Protection (Hiccup Mode)  
Over Voltage Protection (Hiccup Mode)  
Over Temperature Protection (Self-recovery)  
Remote ON/OFF Control  
The BR240 series DC-DC converter are high-efficiency and power density 1/8  
brick isolation modules, rating output voltage 12V, output power 240W. This  
series provide the standard 1/8 brick version and the PMBus compatible  
version. The latter is compatible with the PMBus1.1 communication protocol,  
backward compatible with the I²C/SMBus protocol, and providing Pre-bias,  
output monitoring and current sharing functions. The BR240 series conform to  
the RoHS6 requirement.  
Activates Hardware and Software *  
Digitally Adjusts the Voltage *  
PMBus Revision 1.1 compliant *  
Secondary ON/OFF Control *  
Pre-Bias Function *  
UL60950-1 and CSA C22.2 No. 60950-1-07  
Meet UL94V-0 Flammability Requirements  
Rohs6 Compliant  
Size: 2.3 x 0.9 x 0.5 Inches  
3-Years Product Warranty  
*BR240-12S without this function  
ELECTRICAL SPECIFICATIONS  
Conditions: TA = 25°C (77°F), Airflow = 1 m/s (200 LFM), Vin = 48 V, unless otherwise notes.  
Model No.  
BR240-12S  
BR240-12S-P  
Max Output Wattage (W)  
240W  
Voltage (V.DC.)  
48V (36~75V)  
Input  
Current (A) (max)  
No-Load Loss (W) (typ.)  
Voltage (V.DC.)  
10A (Vin= 36 - 75 V; Iout = 20 A)  
9.6W (Vin= 36 - 75 V; Iout = 0 A)  
12V (Vin= 48 V; Iout = 10 A)  
Voltage Range (V.DC.)  
11.64~12.36V  
(Vin= 40 - 75 V; Adjust the voltage by PMBus)  
11.64~12.36V (Vin= 40 - 75 V)  
10.8~12.36V  
(Vin= 36 - 40 V; Adjust the voltage by PMBus)  
10.8~12.36V (Vin= 36 - 40 V)  
20A  
Current (A) (max.)  
Output  
Line Regulation (LL-HL) (typ.)  
Load Regulation (0-100%) (typ.)  
Ripple & Noise (peak to peak) (typ.)  
Efficiency  
0.2% (Vin= 40 - 75 V; Iout = 20 A) / 10% (Vin= 36 - 40 V; Iout = 20 A  
3% (Vin = 48 V; Iout = 0 – 20 A)  
200 mV (Oscilloscope Bandwidth:20 MHz)  
100% Load:95% (Iout = 20 A)  
(Vin = 48 V; TA=25°C (77°F)) (typ.)  
50% Load:94.5% (Iout = 10 A)  
30% Load:92.0% (Iout = 6 A)  
Over Power Protection  
Hiccup mode  
Over Current Protection  
Over Voltage Protection  
Short Circuit Protection (max.)  
Over Temperature Protection  
Hiccup mode  
15V (14~16V) (Hiccup mode)  
5 Arms (Hiccup mode)  
Threshold:130°C (typ.) / Hysteresis:15°C (typ.)  
Protection  
Self-recovery (The values are obtained by measuring the temperature of the hottest power  
component on the top surface of the converter.)  
Isolation  
Voltage (V.DC.)  
Operating Temperature  
Storage Temperature  
Temperature Coefficient  
Humidity  
1500 VDC (Functional Isolation)  
-40°C…+85°C  
-55°C…+125°C  
0.02 % Vout / °C (TA = -40°C to +85°C (-40°F to +185°F ))  
95% RH  
Environment  
MTBF  
1.5 Million Hours  
(Telcordia SR332; 80% load; TA = 40°C (104°F)  
Safety  
EMC  
Agency Approvals  
CE, UL, TUV  
UL60950-1 and CSA C22.2 No. 60950-1-07  
EMI (Conducted & Radiated Emission)  
Dimension (L x W x H)  
Weight  
2.3 x 0.9 x 0.5 Inches ( 58.4 x 22.8 x 12.7 mm ) Tolerance 0.5 mm  
40 g  
Physical  
http://www.archcorp.com.tw  
TEL: +886-2-26989508 FAX: +886-2-26981319  
-1-  
VER : A_1  
update : 2015.03.16  
DC-DC Brick  
BR240 SERIES  
240 Watts  
ELECTRICAL SPECIFICATIONS  
Conditions: TA = 25°C (77°F), Airflow = 1 m/s (200 LFM), Vin = 48 V, unless otherwise notes.  
Model No.  
Other  
BR240-12S  
BR240-12S-P  
Low level (V.DC.)  
High level (V.DC.)  
Low level (mA) (max.)  
-0.7~1.2V (The primary low electric level is effective)  
On/Off Voltage  
2.8~8V  
1mA  
(The primary low electric level is effective)  
On/Off Current  
Primary On/Off Voltage  
0.7~1.2V  
(The low electric level is effective)  
2.8~8V  
Low level (V.DC.)  
High level (V.DC.)  
Low level (mA) (max.)  
Low level (V.DC.)  
(The low electric level is effective)  
Primary On/Off Current  
Secondary CTL Voltage  
1mA  
0~0.8V  
(The High Electric Level is Effective)  
3.3~3.6V  
(The High Electric Level is Effective)  
High level (V.DC.) (max.)  
Logic Input and Output Pins in the Communications Port  
Logic Input Low level (V.DC.) (max.)  
Logic Input High Level (V.DC.) (max.)  
Logic Output Low Level (V.DC.) (max.)  
Logic Output High Level (V.DC.) (max.)  
PMBus Setting-up Time (ns.) (min.)  
1.1V  
3.6V  
0.25V  
3.6V  
100  
PMBus Holding Time (ns.) (min.)  
0
PMBus Detected Precision (Vin=36 - 75 V; Iout=0 - 20 A;TA = -40°C to +85°C (-40°F to +185°F ))  
Input Voltage Detected Precision (V.DC.)  
Output Voltage Detected Precision (V.DC.)  
Output Current Detected Precision (A)  
Temperature Detected Precision (°C)  
1V  
0.2V  
1A  
5°C  
NOTE  
1. During the test of input reflected ripple current, the input terminal must be connected to a 12 uH inductor and a 220 uF electrolytic capacitor.  
2. Point B, which is for testing the output voltage ripple, is 25 mm (0.98 in.) away from the Vout(+) pin.  
DERATING  
http://www.archcorp.com.tw  
TEL: +886-2-26989508 FAX: +886-2-26981319  
-2-  
VER : A_1  
update : 2015.03.16  
DC-DC Brick  
BR240 SERIES  
240 Watts  
MECHANICAL DIMENSION  
PIN#  
Single  
+DC IN  
1
2
ON / OFF CTL  
-DC IN  
3
4
-DC OUT  
+DC OUT  
SGND  
5
6
7
SA0  
8
PMBus_ALT  
SA1  
9
10  
11  
12  
13  
PMBus_CTL  
ISHARE  
PMBus_SCL  
PMBus_SDA  
Note  
1. All dimensions in mm [in.]  
Tolerances: x.x ± 0.5 mm [x.xx ± 0.02 in.]  
x.xx± 0.25 mm [x.xxx ± 0.010 in.]  
2. Pin 1-3 are 1.00 ± 0.05 mm [0.040 ± 0.002 in.] diameter with 2.00 ± 0.10 mm  
[0.080 ± 0.004 in.] diameter standoff shoulders.  
Pin4 and pin5 are 1.50 ± 0.05 mm [0.060 ± 0.002 in.] diameter with 2.50 ± 0.10  
mm [0.098 ± 0.004 in.] diameter standoff shoulders.  
http://www.archcorp.com.tw  
TEL: +886-2-26989508 FAX: +886-2-26981319  
-3-  

相关型号:

BR2450A

耐高温BR“A”系列扣式锂电池
PANASONIC

BR2450A/GA

Primary Battery, Lithium Poly-carbonmonofluoride, 2450, 3V, 0.55Ah,
PANASONIC

BR246-1000A1-48V

Power/Signal Relay, DPDT, Momentary, 0.048A (Coil), 48VDC (Coil), 2304mW (Coil), 10A (Contact), 28VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
MICROSEMI

BR246-1000A1-48V-032L

Electromechanical Relay, DPDT, 59VDC (Coil), 10A (Contact), 28VDC (Contact), Random, AC/DC Output
MICROSEMI

BR246-1000A1-48V-032M

Electromechanical Relay, DPDT, 59VDC (Coil), 10A (Contact), 28VDC (Contact), Random, AC/DC Output
MICROSEMI

BR246-1000A2-48V

Power/Signal Relay, DPDT, Momentary, 0.048A (Coil), 48VDC (Coil), 2304mW (Coil), 10A (Contact), 28VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
MICROSEMI

BR246-1000A2-48V-035L

Electromechanical Relay, DPDT, 59VDC (Coil), 10A (Contact), 28VDC (Contact), Random, AC/DC Output
MICROSEMI

BR246-1000A2-48V-035M

Electromechanical Relay, DPDT, 59VDC (Coil), 10A (Contact), 28VDC (Contact), Random, AC/DC Output
MICROSEMI

BR246-1000A3-48V

Power/Signal Relay, 2 Form C, DPDT, Momentary, 0.048A (Coil), 48VDC (Coil), 2304mW (Coil), 10A (Contact), 28VDC (Contact), DC Input, Random, AC/DC Output, Through Hole-Straight Mount,
MICROSEMI

BR246-1000B1-48V

Power/Signal Relay, DPDT, Momentary, 0.048A (Coil), 48VDC (Coil), 2304mW (Coil), 10A (Contact), 28VDC (Contact), DC Input, AC/DC Output, Panel Mount,
MICROSEMI

BR246-1000B1-48V-031L

Electromechanical Relay, DPDT, 59VDC (Coil), 10A (Contact), 28VDC (Contact), Random, AC/DC Output
MICROSEMI

BR246-1000B1-48V-031M

Electromechanical Relay, DPDT, 59VDC (Coil), 10A (Contact), 28VDC (Contact), Random, AC/DC Output
MICROSEMI