MQF500E-48S [ARCH]
AC-DC ITE & Medical Switching Power Supply;型号: | MQF500E-48S |
厂家: | ARCH ELECTRONICS CORP. |
描述: | AC-DC ITE & Medical Switching Power Supply |
文件: | 总5页 (文件大小:294K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
VER : A_7
update : 2018.06.06
AC-DC ITE & Medical Switching Power Supply
MQF500E SERIES
500 Watts
KEY FEATURES
Enclosed Medical Switching Power Supply
Remote ON/OFF Function
Standby 5V@1A
High Efficiency up to 92%
With P.F.C. Function >0.94
Ultra Compact Size: 5.5 x 3.25 x 2.48 Inches
3-Year Product Warranty
(except for 15S)
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
MQF500E-12S
500 W
MQF500E-15S
MQF500E-24S
MQF500E-48S
Max Output Wattage (W)
Voltage
90-264 VAC or 127-370 VDC
47-63 Hz
Frequency (Hz)
Current (Full load)
<6.3 A max. (115 VAC) / <3.15 A max. (230 VAC)
< 40 A max. (115 VAC) / < 80 A max. (230 VAC)
< 0.1 mA max. (Input-Output)
Input
Inrush Current (<2ms) (Clod Start)
Leakage Current
Power Factor (at 230 VAC)
Voltage (V.DC.)
PF>0.94 at Full Load
12V
15V
24V
20.8
48V
Voltage Accuracy
±2%
±4% Output Voltage
41.5
Voltage Adj. Range (V.DC)
Current (A) (max.)
33.3
10.41
Line Regulation (115-264 VAC)
Load Regulation (10-100%) (typ.)
Minimum Load
±0.5%
Output
±1%
3%
Maximum Capacitive Load
Ripple & Noise (typ.)
5,000µF
160mV
3,750µF
160mV
89%
2,500µF
240mV
91%
1,250µF
480mV
92%
Efficiency (at 230 VAC)
Hold-up Time (at 115 VAC)
Over Power Protection
Over Voltage Protection
Overt Temperature Protection
89%
8 ms min.
Auto recovery
Auto recovery
Auto recovery
Protection
Isolation
Protection level 1 (nominal):Continuous, Auto recovery
Short Circuit Protection
Protection level 2 (instantaneous high current):Latch
Input-Output (V.AC)
4000VAC or 5656VDC
Input-PE
(V.AC)
2000V
Output-PE .(V.AC)
Operating Temperature
Storage Temperature
1500V
-30°C…+70°C (with derating)
-35°C…+85°C
±0.03%/°C ( 0~50°C )
Temperature Coefficient
±0.06%/°C ( -30~0°C )
Environment
Altitude During Operation
Humidity
5000m
95% RH
Atmospheric Pressure
MTBF
56 kPa to 106 kPa
>160,000 h @ 25°C (MIL-HDBK-217F)
10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes.
Vibration
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-
VER : A_7
update : 2018.06.06
AC-DC ITE & Medical Switching Power Supply
MQF500E SERIES
500 Watts
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
MQF500E-12S
MQF500E-15S
MQF500E-24S
MQF500E-48S
Dimension (L x W x H)
Weight
5.5 x 3.25 x 2.48 Inches ( 139.7 x 82.55 x 62.9 mm ) Tolerance 0.5 mm
690 g
Others: UL / IEC / EN 60601 3.1rd Edition & UL / IEC / EN 60950 AM2
Physical
Safety
EMC
Approval
15S:
UL / IEC / EN 60601 3.1rd Edition (In Progress)
Conducted and Radiated EMI
EMS
EN55011 / conducted class B, Radiated Class A
EN60601-1-2 4th edition
NOTE
1. Ripple & Noise are measured at 20MHz of bandwidth with ceramic 0.1uF & chemi-con KY 47uF parallel capacitor.
A 30cm twisted pair of no.18 AWG copper wire is connected to a
47uF and 0.1uF capacitor of proper polarity and voltage rating.
The oscilloscope probe ground led should connect right to the
ground ring of the probe and be as short as possible.
The oscilloscope bandwidth should be at 20MHz and connected
to AC ground.
2. Hold-up Time measured at 90% Vout.
3. Main Vout >3% Load, 12V (Aux) / 0.3A., 12V (Aux) need 0.1A Minimum Load, Auxiliary voltage output ground 10.2~13.3V
4. Strongly recommend to conduct this test with DC Voltage. If customer wishes to test with AC Voltage,
please disconnect all Y-Capacitors within Arch power supply.
DERATING
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
VER : A_7
update : 2018.06.06
AC-DC ITE & Medical Switching Power Supply
MQF500E SERIES
500 Watts
MECHANICAL DIMENSION
( Top View )
A=For fixture to din rail clip only
B=For fixture to pcb/chassis only
A=M3x0.5P
B=M3x0.5P
ASSEMBLY INSTRUCTIONS
*U Case T=1.5mm
Customer is advised to screw into the threads no more than 2.5mm
Connector Pin (CN1) = Cherng Weei PHD2.0 - 2x4P
PIN#
A
Single
PE
Mating Housing
Terminal
PIN#
C1
C2
C3
C4
C5
C6
C7
C8
Single
-5VSB
+5VSB
GND
DC OK
-RC
Mating Housing
Terminal
AC Input Connector Pin : Alex 9397-3
1
2
3
AC IN (N)
NO PIN
Alex 9396-3
or equivalent
Alex 96T Series
or equivalent
Cherng Weei
PHD2.0 - 2x4P
or equivalent
Cherng Weei
PHD2.0 - 2x4P
or equivalent
AC IN (L)
DC Output Connector Pin
+RC
4
5
+DC OUT
-DC OUT
M5 Pan HD screw in 2 positions
Torque to 8 Ibs-in(90 cNm) max.
-S
+S
Connector Pin (FAN) = Cherng Weei CX-W250-02
PIN#
F1
Single
+12V
GND
Mating Housing
Cherng Weei
CS-H250-02
or equivalent
Terminal
Cherng Weei
CS-T2501
F2
or equivalent
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-3-
VER : A_7
update : 2018.06.06
AC-DC ITE & Medical Switching Power Supply
MQF500E SERIES
500 Watts
FUNCTION DESCRIPITON of CN1
Pin No.
C1
Function
-5VSB
Description
This pin connects to the negative terminal(-V). Return for DC-OK and -RC signal output.
Stand by voltage output ground 4.2~5.5V, referenced to pin C1(-5VSB).
The maximum load current is 1A with Fan, 0.4A without Fan..
C2
+5VSB
C3
C4
C5
GND
DC OK
-RC
This pin connects to the negative terminal(-V). Return for DC-OK and -RC signal output.
DC-OK Signal is a DC output, referenced to pin C3(DC-OK GND).
This pin connects to the negative terminal(-V). Return for DC-OK and -RC signal output.
Turns the output on and off by electrical or dry contact between pin C5 (-RC), Short: Power OFF, Open: Power ON.
The input voltage must be less than 1V in order to disable VOUT and greater than 3.3V (up to 5V) to enable it.
Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be
twisted in pair to minimize noise pick-up effect.
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be
twisted in pair to minimize noise pick-up effect.
C6
C7
C8
+RC
-S
+S
FUNCTION MANUAL & APPLICATION NOTE
1. DC-OK Signal
Between
DC-OK and GND
Output
Status
3.7~6V
0~1V
ON
OFF
2. Remote Control
It can be turned ON/OFF by using the "Remote Control" function.
Between
+RC and -RC
Output
Status
SW ON (Short)
SW OFF (Open)
OFF
ON
2. +S and -S Sense
Shorter wiring to each unit is recommended, as well as twisting +S and -S in pairs, as shown below
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-4-
VER : A_7
update : 2018.06.06
AC-DC ITE & Medical Switching Power Supply
MQF500E SERIES
500 Watts
BLOCK DIAGRAM
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-5-
相关型号:
©2020 ICPDF网 联系我们和版权申明