ADNB075-12-1PM-C [ARTESYN]
The ADNB 96W series features a universal 88-264Vac input;型号: | ADNB075-12-1PM-C |
厂家: | ARTESYN TECHNOLOGIES |
描述: | The ADNB 96W series features a universal 88-264Vac input |
文件: | 总21页 (文件大小:2995K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 1
ADNB 96W Series
Up to 96 Watts
Din Rail
Total Power: Up to 96 Watts
Input Voltage: 88 to 264 Vac
124 to 370 Vdc
# of Outputs: Single
Special Features
• Universal AC input 88-264Vac
• Installed on DIN rail TS35/7.5 or 15
• Brown-out Protection
• Protections:Short Circuit/Over
load/Over voltage
Product Descriptions
The ADNB 96W series features a universal 88-264Vac input – enabling it to be
used anywhere in the world – and is also capable of operating from a 124-
370Vdc Input. The ADNB 96W series offers a power rating up to 96W with
convectioncooling, and it provides precisely regulated output voltages of 12V,
15V, 24V and 48Vdc.
• All using 105degC long life
electrolytic capacitors
• High operation temperature up to
The ADNB 96W series power supply is comprehensively protected against over
voltage, over load and short-circuit conditions.
70OC
• Withstand 2G vibration test
• High efficiency, long life and high
reliability
• 3 Years Warranty
Safety*
UL /cUL 508
TUV EN60950-1
LPS Pass
UL1310 class 2 (except ADNB075-
12-1PM-C, ADNB064-15-1PM-C)
Note* - Cover AC input only
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 2
Model Numbers
Model
Output Voltage
Minimum Load
Maximum Load
Efficiency1
ADNB075-12-1PM-C
ADNB064-15-1PM-C
ADNB040-24-1PM-C
ADNB020-48-1PM-C
12Vdc
15Vdc
24Vdc
48Vdc
0A
0A
0A
0A
7.5A
6.4A
4.0A
2.0A
87%
87%
88%
87%
Note 1 - Typical value at nominal input voltage(230Vac) and maximum load.
Options
None
Artesyn Embedded Technologies
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 3
Electrical Specifications
Absolute Maximum Ratings
Stress in excess of those listed in the “Absolute Maximum Ratings” may cause permanent damage to the power supply.
These are stress ratings only and functional operation of the unit is not implied at these or any other conditions above
those given in the operational sections of this TRN. Exposure to any absolute maximum rated condition for extended
periods may adversely affect the power supply’s reliability.
Table 1. Absolute Maximum Ratings:
Parameter
Model
Symbol
Min
Typ
Max
Unit
Input Voltage
AC continuous operation
DC continuous operation
All models
All models
VIN,AC
VIN,DC
88
124
-
-
264
370
Vac
Vdc
ADNB075-12-1PM-C
ADNB064-15-1PM-C
ADNB040-24-1PM-C
ADNB020-48-1PM-C
-
-
-
-
-
-
-
-
90
96
96
96
W
W
W
W
Maximum Output Power
Convection continuous operation
PO,max
Isolation Voltage
Input to Output
Input to Safety Ground
Output to Earth Ground
All models
All models
All models
-
-
-
-
-
-
4242
2121
500
Vdc
Vdc
Vdc
Ambient Operating Temperature
All models
All models
TA
-20
-40
-
-
+701
+85
OC
OC
Storage Temperature
TSTG
Humidity (non-condensing)
Operating
Non-operating
All models
All models
20
10
-
-
90
95
%
%
MTBF
All models
-
366.4
-
Khours
Note 1 - Derate each output at 2.5% per degree C from 50 OC to 70 OC.
Artesyn Embedded Technologies
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 4
Input Specifications
Table 2. Input Specifications:
Parameter
Conditions
Symbol
VIN,AC
VIN,DC
fIN
Min
88
Typ
115/230
-
Max
264
370
63
Unit
Vac
Vdc
Hz
Operating Input Voltage, AC1
Operating Input Voltage, DC
Input AC Frequency
All
All
All
124
47
50/60
VIN,AC = 115Vac
VIN,AC = 230Vac
-
-
1.1
0.55
-
-
Input Current
IIN,max
A
No Load Input Power
(VO = ON, IO = 0A)
VIN,AC = 115/230Vac PIN,no-load
-
-
5
W
Harmonic Line Currents
All
THD
EN61000-3-2/EN61000-3-3
Startup Surge Current (Inrush)
@ 25°C
VIN,AC = 230Vac
IIN,surge
-
60
-
APK
ADNB075-12-1PM-C
-
-
-
-
87
87
88
87
-
-
-
-
Efficiency
(TA = 25oC, free air
convectioncooling)
ADNB064-15-1PM-C
ADNB040-24-1PM-C
ADNB020-48-1PM-C
VIN,AC = 230Vac
IO = IO,max
η
%
VIN,AC = 115Vac
PO = PO,max
tHold-Up
tHold-Up
tTurn-On
16
32
-
-
-
-
-
mSec
mSec
mSec
mSec
µA
Hold Up Time
Turn On Delay
VIN,AC = 230Vac
PO = PO,max
-
VIN,AC = 115Vac
PO = PO,max
800
800
1000
VIN,AC = 230Vac
PO = PO,max
tTurn-On
-
-
-
-
Leakage Current to safety ground
VIN = 240Vac
fIN = 50/60Hz
IIN,leakage
Artesyn Embedded Technologies
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 5
Output Specifications
Table 3. Output Specifications:
Parameter
Conditions
Symbol
Min
Typ
Max
Unit
Factory Set Point Accuracy
All
VO
-1.0
-
+1.0
%
ADNB075-12-1PM-C
-
-
-
-
12.0
15.0
24.0
48.0
-
-
-
-
ADNB064-15-1PM-C
ADNB040-24-1PM-C
ADNB020-48-1PM-C
VO
Output Voltage
All
All
Vdc
Vdc
ADNB075-12-1PM-C
ADNB064-15-1PM-C
ADNB040-24-1PM-C
ADNB020-48-1PM-C
10.8
13.5
21.6
43.2
-
-
-
-
13.2
16.5
26.4
52.8
Output Adjust
Range
VO
Measure with a 0.1µF
ceramic capacitor in
parallel with a 47µF
aluminum electrolytic
capacitor
ADNB075-12-1PM-C
ADNB064-15-1PM-C
ADNB040-24-1PM-C
ADNB020-48-1PM-C
-
-
-
-
-
-
-
-
180
180
180
250
Output Ripple, pk-
pk
VO
mVPK-PK
ADNB075-12-1PM-C
ADNB064-15-1PM-C
ADNB040-24-1PM-C
ADNB020-48-1PM-C
0
0
0
0
-
-
-
-
7.5
6.4
4.0
2.0
Convection Output
Current,
continuous
Convection cooling
IO,max
A
VIN,DC=VIN,min to VIN,
IO=IO,max
max
Line Regulation
Load Regulation
VO
VO
VO
IO
-1.0
-2.0
115
102
-
-
-
-
+1.0
+2.0
150
-
%
%
IO=IO,min to IO,max
Latch off
(AC recycle to reset)
VO Over Voltage Protection
VO Over Current Protection1
%
All
%IO,max
Note 1 - Constant current and Auto recovery after fault condition is removed.
Artesyn Embedded Technologies
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 6
ADNB075-12-1PM-C Performance Curves
Figure 2: ADNB075-12-1PM-C Output Voltage Protection – Vin=88Vac
Figure 1: ADNB075-12-1PM-C Ripple and Noise Measurement – Vin = 88Vac
Ta = 25 O
C
Load: Io = 7.5A
Ch 1: Vo
Ta = 25 O
C
Load: Io = 0.75A
Ch 1: Vo
Figure 3: ADNB075-12-1PM-C Turn-on delay – Vin= 88Vac
Figure 4: ADNB075-12-1PM-C Hold Up Time –Vin=88Vac
Load: Io = 7.5A
Ch 1: Vo
Ta = 25 O
Ch2:AC Mains
C
Load: Io = 7.5A
Ch 1: Vo
Ta = 25 O
Ch 2: AC Mains
C
Figure 5: ADNB075-12-1PM-C Transient Response
Figure 6: ADNB075-12-1PM-C Inrush Current
Vin = 230Vac
Ch 1: Vo
Load: Io = 10% ~ 90%
Ch 2: Iout
Duty: 1kHz
Vin = 264Vac
Ch 1: Iin
Load: Io = 7.5A
Ch 2: AC Mains
Ta = 25 O
C
Artesyn Embedded Technologies
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 7
ADNB064-15-1PM-C Performance Curves
Figure 8: ADNB064-15-1PM-C Output Voltage Protection – Vin=88Vac
Figure 7: ADNB064-15-1PM-C Ripple and Noise Measurement – Vin = 88Vac
Ta = 25 O
C
Load: Io = 6.5A
Ch 1: Vo
Ta = 25 O
C
Load: Io = 0.65A
Ch 1: Vo
Figure 9: ADNB064-15-1PM-C Turn-on delay – Vin= 88Vac
Figure 10: ADNB064-15-1PM-C Hold Up Time –Vin=88Vac
Load: Io = 6.5A
Ch 1: Vo
Ta = 25 O
Ch2:AC Mains
C
Load: Io = 6.5A
Ch 1: Vo
Ta = 25 O
Ch 2: AC Mains
C
Figure 11: ADNB064-15-1PM-C Transient Response
Figure 12: ADNB064-15-1PM-C Inrush Current
Vin = 230Vac
Ch 1: Vo
Load: Io = 10% ~ 90%
Ch 2: Iout
Duty: 1kHz
Vin = 264Vac
Ch 1: Iin
Load: Io = 6.5A
Ch 2: AC Mains
Ta = 25 O
C
Artesyn Embedded Technologies
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 8
ADNB040-24-1PM-C Performance Curves
Figure 14: ADNB040-24-1PM-C Output Voltage Protection – Vin=88Vac
Figure 13: ADNB040-24-1PM-C Ripple and Noise Measurement – Vin = 88Vac
Ta = 25 O
C
Load: Io = 4.0A
Ch 1: Vo
Ta = 25 O
C
Load: Io = 0.4A
Ch 1: Vo
Figure 15: ADNB040-24-1PM-C Turn-on delay – Vin= 88Vac
Figure 16: ADNB040-24-1PM-C Hold Up Time –Vin=88Vac
Load: Io = 4.0A
Ch 1: Vo
Ta = 25 O
Ch2:AC Mains
C
Load: Io = 4.0A
Ch 1: Vo
Ta = 25 O
Ch 2: AC Mains
C
Figure 17: ADNB040-24-1PM-C Transient Response
Figure 18: ADNB040-24-1PM-C Inrush Current
Vin = 230Vac
Ch 1: Vo
Load: Io = 10% ~ 90%
Ch 2: Iout
Duty: 1kHz
Vin = 264Vac
Ch 1: Iin
Load: Io = 1.7A
Ch 2: AC Mains
Ta = 25 O
C
Artesyn Embedded Technologies
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 9
ADNB020-48-1PM-C Performance Curves
Figure 20: ADNB020-48-1PM-C Output Voltage Protection – Vin=88Vac
Figure19: ADNB020-48-1PM-C Ripple and Noise Measurement – Vin = 88Vac
Ta = 25 O
C
Load: Io = 2.0A
Ch 1: Vo
Ta = 25 O
C
Load: Io = 0.2A
Ch 1: Vo
Figure 21: ADNB020-48-1PM-C Turn-on delay – Vin= 88Vac
Figure 22: ADNB020-48-1PM-C Hold Up Time –Vin=88Vac
Load: Io = 2.0A
Ch 1: Vo
Ta = 25 O
Ch2:AC Mains
C
Load: Io = 2.0A
Ch 1: Vo
Ta = 25 O
Ch 2: AC Mains
C
Figure 23: ADNB020-48-1PM-C Transient Response
Figure 24: ADNB020-48-1PM-C Inrush Current
Vin = 230Vac
Ch 1: Vo
Load: Io = 10% ~ 90%
Ch 2: Iout
Duty: 1kHz
Vin = 264Vac
Ch 1: Iin
Load: Io = 2.0A
Ch 2: AC Mains
Ta = 25 O
C
Artesyn Embedded Technologies
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 10
Protective Function Specifications
Over Voltage Protection (OVP)
The power supply output voltagelatches off during output overvoltage with the AC line recycled to reset the latch.
ADNB075-12-1PM-C
Parameter
Min
Nom
Max
Unit
12V Vo Output Overvoltage
13.8
/
18
V
ADNB064-15-1PM-C
Parameter
Min
Nom
Max
Unit
15V Vo Output Overvoltage
17.25
/
22.5
V
ADNB040-24-1PM-C
Parameter
Min
Nom
Max
Unit
24V Vo Output Overvoltage
27.6
/
36
V
ADNB020-48-1PM-C
Parameter
Min
Nom
Max
Unit
48V Vo Output Overvoltage
55.2
/
72
V
Artesyn Embedded Technologies
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 11
Over Current Protection (OCP)
ADNB 96W series power supply includes internal current limit circuitry to prevent damage in the event of overload or short
circuit. In the event of overloads, it will go to constant current model, the output voltagemay deviate from the regulation
band but recovery is automatic when the load is reduced to within specified limits.
ADNB075-12-1PM-C
Parameter
Min
Nom
Max
Unit
12V Vo Output Overcurrent
7.65
/
/
A
ADNB064-15-1PM-C
Parameter
Min
Nom
Max
Unit
15V Vo Output Overcurrent
6.528
/
/
A
ADNB040-24-1PM-C
Parameter
Min
Nom
Max
Unit
24V Vo Output Overcurrent
4.08
/
/
A
ADNB020-48-1PM-C
Parameter
Min
Nom
Max
Unit
48V Vo Output Overcurrent
2.04
/
/
A
Artesyn Embedded Technologies
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 12
Mechanical Specifications
Mechanical Drawing (Dimensioning and Mounting Locations)
Artesyn Embedded Technologies
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 13
Weight
The ADNB 96W series packing weight is 0.882lb/400g typical.
Artesyn Embedded Technologies
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 14
Environmental Specifications
EMC Immunity
ADNB 96W series power supply is designed to meet the following EMC immunity specifications:
Table 4. Environmental Specifications:
Document
EN 55022
Description
Conducted Level B and Radiated Level B (stand alone)
Harmonic Distortion
EN 61000-3-2
EN 61000-3-3
EN 61204-3
EN 55024
Harmonic Distortion
EMS immunity
EMS immunity
Artesyn Embedded Technologies
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 15
Safety Certifications
The ADNB 96W series power supply is intended for inclusion in other equipment and the installer must ensure that it is in
compliancewith all the requirements of the end application. This product is only for inclusion by professional installers
within other equipment and must not be operated as a stand alone product.
Table 5. Safety Certifications for ADNB 96W series power supply system:
Document
Description
UL/cUL508/UL1310
TUV EN60950-1
US and Canada Requirements
Germany and European Requirements (All CENELEC Countries)
Artesyn Embedded Technologies
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 16
EMI Emissions
The ADNB 96W series has been designed to comply with the Class B limits of EMI requirements of EN55022 (FCC Part
15) and CISPR 22 (EN55022) for emissions and relevant sections of EN61000 (IEC 61000) for immunity.
The unit is enclosed inside a metal box, tested at full load using resistive load.
Conducted Emissions
The applicable standard for conducted emissions is EN55022 (FCC Part 15). Conducted noise can appear as both
differential mode and common mode noise currents. Differential mode noise is measured between the two input lines, with
the major components occurring at the supply fundamental switching frequency and its harmonics. Common mode noise,
a contributor to both radiated emissions and input conducted emissions, is measured between the input lines and system
ground and can be broadband in nature.
Table 6. Conducted EMI emission specifications of the ADNB 96W series
Parameter
Model
All
Symbol
Margin
Margin
Min
Typ
Max
6
Unit
dB
FCC Part 15, class B
CISPR 22 (EN55022) class B
-
-
-
-
All
6
dB
Artesyn Embedded Technologies
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 17
Radiated Emissions
Unlike conducted EMI, radiated EMI performance in a system environment may differ drastically from that in a stand-alone
power supply. It is thus recommended that radiated EMI be evaluated in a system environment. The applicable standard
is EN55022 Class B (FCC Part 15). Testing ac-dc convertors as a stand-alone component to the exact requirements of
EN55022 can be difficult, because the standard calls for 1m leads to be attached to the input and outputs and aligned such
as to maximize the disturbance. In such a set-up, it is possible to form a perfect dipole antenna that very few ac-dc
convertors could pass. However, the standard also states that ‘an attempt should be made to maximizethe disturbance
consistent with the typical application by varying the configurationof the test sample’.
Artesyn Embedded Technologies
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 18
Operating Temperature
The ADNB 96W series start and operate within stated specifications at an ambient temperature from -25 OC to 70 OC
under all load conditions (see below derating curves for other amount of convectionand orientation. Derate output current
and power by 2.5% per degree above 50 OC. Maximum operating ambient temperature is 70 OC (which implies a 50%
derating at max 70 OC ambient).
Under convection cooling condition, the maximum output power derates linearly from full load. When input voltageis
90Vac, the maximum output power will derate to 90% full load.
Derating Curve
Artesyn Embedded Technologies
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 19
Storage and Shipping Temperature / Humidity
The ADNB 96W series can be stored or shipped at temperatures between -40 OC to +85 OC and relative humidity from
10% to 95%, non-condensing.
Humidity
The ADNB 96W series will operate within specifications when subjected to a relativehumidity from 20% to 90% non-
condensing. The ADNB 96W series can be stored in a relativehumidity from 10% to 95% non-condensing.
Vibration
The ADNB 96W series will pass the following vibrationspecifications:
Acceleration
Frequency Range
Duration
2
gRMS
Hz
10-500
10
mins
Direction
3 mutually perpendicular axis
SLOPE
dB/oct
---
PSD
g2/Hz
---
PSD Profile
FREQ
10-500 Hz
Artesyn Embedded Technologies
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 20
Application Notes
Block Diagram
DC OK Relay Contact
Contact Close
When the output voltagereaches the adjusted output voltage
When the output voltagedrop below 90% output voltage
30V/1A resistive load
Contact Open
Contact Ratings(max.)
Artesyn Embedded Technologies
Technical Reference Note
Rev.04.19.16_#1.1
ADNB 96W Series
Page 21
Output Ripple and Noise Measurement
The setup outlined in the diagram below has been used for output voltageripple and noise measurements on the ADNB
96W series . When measuring output ripple and noise, a scope jack in parallel with a 0.1uF ceramic chip capacitor, and a
47uF aluminum electrolytic capacitor should be used. Oscilloscope should be set to 20MHz bandwidth for this
measurement.
For more information: www.artesyn.com/power
For support: productsupport.ep@artesyn.com
相关型号:
©2020 ICPDF网 联系我们和版权申明