DS550HE-3 [ARTESYN]
Distributed Power System;型号: | DS550HE-3 |
厂家: | ARTESYN TECHNOLOGIES |
描述: | Distributed Power System |
文件: | 总4页 (文件大小:320K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Embedded Power for
Business-Critical Continuity
Rev. 03.02.10_70
DS450HE-3/DS550HE-3
1 of 4
DS450HE-3/
DS550HE-3
450 W - 550 W
Distributed Power System
Distributed Power Bulk Front-End
Total Output Power: 450 - 550 Watts
+12 Vdc Main Output
+3.3 Vdc Stand-by Output
Wide Range Input Voltage: 90 - 264 Vac
Electrical Specifications
Input
Special Features
Input range:
90 - 264 Vac (wide range)
• Active Power Factor Correction
• EN61000-3-2 Harmonic
Compliance
Frequency:
Inrush current:
47 - 63 Hz, single phase AC
15 A maximum
Efficiency:
See curve
• Active AC Inrush Control
• 1U X 2U Form Factor
Conducted EMI:
Radiated EMI:
Power factor:
Leakage current:
Hold up time:
Output
FCC Subpart J EN55022 Class A
FCC Subpart J EN55022 Class A
0.99 typical
3
• 10.3 W / in (DS550HE)
3
8.4 W / in (DS450HE)
• +12 Vdc Output
1.30 mA @ 240 Vac
20 ms minimum
• +3.3 Vdc Stand-By
• No Minimum Load Required
• Hot Plug Operation
• N + 1 Redundant
Main DC voltage:
+12 V
• Internal OR’ing Fets
• Active Current Sharing
• Built-in Cooling Fans
(40 mm x 28 mm)
Stand-By:
+3.3 Vsb
Adjustment range:
Regulation:
Factory Set, no pot adjustments
2
+12 Vdc; +5%/-3%
+3.3 Vsb; +5%/-4%
• I C Communication Interface Bus
• EERPOM for FRU Data
• Amber LED Status, Fan_Fail
• Green LED Status, Power Good /
AC_OK Status
• Internal Fan Speed Control
• Fan Fail Tach Output Signal
• Two Year Warranty
Overcurrent:
Overvoltage:
See Table 1 next page
+12 Vdc; 13.5 - 15 Vdc
+3.3 Vsb; 3.76 - 4.30 Vdc
Undervoltage:
+12 Vdc; 11.0 - 11.5 Vdc
+3.3 Vsb; 2.77 - 3.00 Vdc
Turn-on delay:
1 Second max
+12 V Output Rise Time:
2 - 20 mS, Monotonic
Safety
•
•
•
•
•
UL/cUL 60950 (UL Recognized)
NEMKO+ CB Report EN60950
EN60950
CE Mark
China CCC
Embedded Power for
Business-Critical Continuity
Rev. 03.02.10_70
DS450HE-3/DS550HE-3
2 of 4
Logic Control
PS Inhibit:
When supply is inserted into the system the pin is pulled LOW and power supply is ON after all other pins are seated
2
PS_Status:
I C port P6. When the power supply is on and running normal P6 is low. When the power supply is off, either due to
-PS_ON, PS_KILL, or a fault, then P6 is high.
2
AC_Pfail:
I C port P7. P7 is high except when the power supply turns the main outputs, not +3.3 Vsb, off due to an AC failure
(AC missing or too low for power supply operation). If the supply is turned off due to -PS_ON, PS_KILL, or a fault,
then P7 remains high.
Fan_Fault:
Tach_1:
The PSU will provides an open collector Tach 1 output.
This signal is generated from the fan. The signal should generate 2 pulses per revolution. The logic in the
system will be operating at 3.3 V.
Environmental Specifications
Operating temperature:
-10 °C to 50 °C
Storage temperature:
Altitude, operating:
-40 °C to +70 °C
10,000 ft.
Electromagnetic
-EN61000-3-2, -3-3
susceptibility / Input transients: -EN61000-4-2, 4.3, 4-4, -4-5, 4-11 Level
-EN55024:1998
RoHS & lead-free compliant (no tantalum caps)
Humidity:
20 to 90% RH, non-condensing
Shock and vibration specificatons complies with Emerson Network Power Std. Specification, Q3205
MTBF (Demonstrated):
Ordering Information
400K Hrs at full load, 40 °C
Nominal Output Set Point
Voltage Set Point Tolerance Regulation
Total
Minimum
Current
Maximum Output Ripple
Output
Overcurrent
Current
P/P
12.0 Vdc
3.3 Vsb
± 0.2%
± 1%
+5 / -3%
+5 / -4%
0 A
0 A
37.0 A
3.0 A
120 mV
60 mV
39.5 A - 44.4 A
4.9 A Avg, 7 A max
DS450HE-3
DS550HE-3
12.0 Vdc
3.3 Vsb
± 0.2%
± 1%
+5 / -3%
+5 / -4%
0 A
0A
45.0 A
3.0 A
120 mV
60 mV
48.0 A - 54.0 A
4.9 A Avg, 7 A max
*Overcurrent latches off if overcurrent lasts over 1 second, otherwise it is auto recovery.
*For 5 Vsb, consult marketing.
95
90
85
80
75
70
65
60
55
50
110 V EFFICIENCY %
220 V EFFICIENCY %
10
20
30
50
LOAD %
75
100
Embedded Power for
Business-Critical Continuity
Rev. 03.02.10_70
DS450HE-3/DS550HE-3
3 of 4
Mechanical Drawing
Embedded Power for
Business-Critical Continuity
Rev. 03.02.10_70
DS450HE-3/DS550HE-3
4 of 4
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
DC Output Connector Pinout Assignment
Male connector as viewed from the rear of the supply:
D1 D2 D3 D4 D5 D6
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
C1 C2 C3 C4 C5 C6
PB1 PB2 PB3 PB4 PB5 PB6
B1 B2 B3 B4 B5 B6
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
A1 A2 A3 A4 A5 A6
P1 - Power Supply Side
Pin
Signal Name
+12 V Return
PB 1
1. FCI Power Blade 51721 series
51721-10002406AA
PB 2
PB 3
PB 4
PB 5
PB 6
A1
A2
A3
A4
A5
A6
B1
B2
B3
B4
B5
B6
C1
+12 V Return
+12 V Return
+12 V
Asia (HK)
14/F, Lu Plaza
2. Molex Power Connector
SD-87667 series
87667-7002
+12 V
+12 V
PS_KILL
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
+12 V_Current Share
Logic Return
Write Protect
Mating Connector (System Side)
2
For global contact, visit:
1.FCI Power Blade
51741-10002406CC
Strait Pins
A0 (I C Address BIT 0 Signal)
www.Emerson.com/EmbeddedPower
+3.3V Stand-By
Logic Return
12V Sense Return
Logic Return
techsupport.embeddedpower
@emerson.com
2.FCI Power Blade
51761-10002406AA
Right Angle
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
+3.3 V Stand-By
2
SDA (I C Data Signal)
PSON (Power Enable Signal)
Logic Return
C2
C3
C4
C5
Tach_1 (Fan Fail Signal)
Logic Return
Emerson Network Power.
The global leader in enabling
business-critical continuity.
+3.3 V Stand-By
2
SCL (I C Clock Signal)
AC Power
C6
VIN_GOOD (AC Input present)
Connectivity
D1
-PS_Present (Power Supply Seated)
DC Power
D2
D3
D4
D5
D6
+12 V Sense
Logic Return
+3.3 V Stand-By
S_INT (Alert)
Embedded Computing
Embedded Power
Monitoring
POK (Output Power Ok)
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2010 Emerson Electric Co.
相关型号:
©2020 ICPDF网 联系我们和版权申明