NLS110-9602 [ARTESYN]

LOW TO MEDIUM POWER AC/DC POWER SUPPLIES; 中低功率AC / DC电源
NLS110-9602
型号: NLS110-9602
厂家: ARTESYN TECHNOLOGIES    ARTESYN TECHNOLOGIES
描述:

LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
中低功率AC / DC电源

文件: 总3页 (文件大小:60K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
NLS110-9602  
Q u a d o u t p u t  
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies  
1
7.0 x 4.25 x 1U package  
Overvoltage and short circuit protection  
110W with 20CFM  
90VAC to 264VAC universal input range  
EN55022 conducted emissions level B, radiated  
emissions level A  
UL, VDE and CSA safety approvals  
CE mark  
The NLS110-9602 is a 110W universal input AC/DC power supply on a 7 x 4.25 inch  
card. The NLS110-9602 has proven itself to be highly reliable and versatile product for  
a wide range of communication and industrial applications, with a very high peak  
current capability on each output for drive and motor applications. The NLS110-9602  
provides 80W of output power with free air convection cooling which can be boosted to  
110W with 20CFM of air. Standard features include overvoltage and short circuit  
protection. The NLS110-9602 with full international safety approval and the CE mark,  
meets conducted emissions EN55022 level B. The NLS110-9602 is designed for use in  
low power data networking, computer, telecom and industrial applications such as  
servers, thermal printers, storage devices, vending machines and POS equipment.  
2 YEAR WARRANTY  
All specifications are typical at nominal input, full load at 25°C unless otherwise stated  
SPECIFICATIONS  
OUTPUT SPECIFICATIONS  
GENERAL SPECIFICATIONS  
Total regulation  
Line and load  
(See table)  
1.0s, max.  
Hold-up time  
120VAC @ 60Hz  
35ms @ 80W  
25ms @ 110W  
Rise Time  
At turn-on  
Efficiency  
120VAC @ 110W  
70% min.  
Transient response  
Temperature coefficient  
Overvoltage protection  
Short circuit protection  
(See table)  
±0.02% /°C  
125% , ±10%  
Isolation voltage  
Input/output  
Input/chassis  
3000VAC  
1500VAC  
+5.1V  
Approvals and  
standards  
EN60950, VDE0805, IEC950  
UL1950, CSA C22.2 No. 950  
Cyclic operation  
Yes with auto  
recovery  
Weight  
383g (13.5 oz.)  
MTBF (@ 25˚C)  
MIL-HDBK-217F  
220,000 hours min.  
INPUT SPECIFICATIONS  
Input voltage range  
Universal input  
90 to 264VDC  
47Hz to 440Hz  
(6,8)  
ENVIRONMENTAL SPECIFICATIONS  
Input frequency range  
Thermal performance  
Operating ambient,  
(see derating curve)  
Non-operating  
+50°C to +70°C,  
amb. convection cooled  
0°C to +50°C  
Input surge current  
(cold start)  
120VAC  
230VAC  
18A max.  
35A max.  
–40°C to +85°C  
Derate to  
Safety ground  
leakage current  
120VAC, 60Hz  
230VAC, 50Hz  
0.45mA  
0.75mA  
50% load  
0°C to +50°C,  
80W  
amb. convection cooled  
0°C to +50°C ambient,  
150LFM forced air  
Input current  
Input fuse  
120VAC @ 80W  
120VAC @ 110W  
230VAC @ 80W  
230VAC @ 110W  
0.95A rms  
1.35A rms  
0.53A rms  
0.75A rms  
110W  
Peak (0°C to +50°C, 60s) (See Note 4)  
Relative humidity  
Altitude  
Non-condensing  
5% to 95% RH  
UL/IEC127  
F3.15A H, 250VAC  
Operating  
Non-operating  
10,000 feet max.  
30,000 feet max.  
(11)  
EMC CHARACTERISTICS  
Conducted emissions  
EN55022, FCC part 15  
EN55022, FCC part 15  
EN61000-3-2  
Level B  
Level A  
Compliant  
Vibration (See Note 7)  
Shock  
5Hz to 500Hz  
2.4G rms peak  
516.4 Part IV  
Radiated emissions  
Harmonic current  
emission correction  
ESD air  
ESD contact  
Surge  
Fast transients  
Radiated immunity  
Conducted immunity  
per MIL-STD-810E  
EN61000-4-2  
EN61000-4-2  
EN61000-4-5  
EN61000-4-4  
EN61000-4-3  
EN61000-4-6  
Level 3  
Level 3  
Level 3  
Level 3  
Level 3  
Level 3  
File Name: NLS110.PDF Rev: 12 June 2001  
NLS110-9602  
Q u a d o u t p u t  
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies  
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm  
OUTPUT CURRENTS  
OUTPUT  
VOLTAGE  
TOTAL  
REGULATION  
(4)  
RIPPLE  
MODEL NUMBERS  
(5)  
(2)  
(3)  
MAX (1)  
8.0A  
PEAK  
FAN  
(12)  
+5.1V  
+24.0V  
+12.0V  
–12.0V  
20.0A  
4.5A  
9.0A  
1.5A  
10.0A  
4.5A  
5.0A  
1.0A  
50mV  
±2.0%  
±5.0%  
±3.0%  
±3.0%  
NLS110-9602  
3.5A  
240mV  
120mV  
120mV  
4.5A  
0.5A  
Notes  
TRANSIENT RESPONSE  
1
2
Convection cooled, 80W maximum.  
Peak outputs lasting less than 60 seconds with duty cycle less than 10% .  
Total peak power must not exceed 110W.  
NLS110-9602  
+5.1V (7.5A to 10A)  
+24V (1.5A to 3A)  
+12V (2.5A to 5A)  
-12V (0.5A to 1A)  
150mV peak,  
1ms recovery  
300mV peak,  
1ms recovery  
100mV peak,  
0.5ms recovery  
3
4
Forced air, 20CFM at 1 atmosphere, 110W maximum.  
Amplitude is peak-to-peak. Output ripple is measured across a 20MHz  
bandwidth using a 12 inch twisted pair terminated with a 10µF capacitor.  
Total regulation is defined as the static output regulation at 25°C, including  
initial tolerance, line voltage within stated limits and output voltages  
adjusted to their factory settings.  
Derating curve is application specific for ambient temperatures >50°C.  
Three orthogonal axes, random vibration, 10 minute test for each axis.  
For optimum reliability no part of the heatsink should exceed 100oC and no  
semiconductor case temperature should exceed 115oC.  
5
100mV peak,  
0.5ms recovery  
6
7
8
9
Caution: Allow a minimum of 1 second after disconnecting the power when  
making thermal measurements.  
DERATING CURVE  
Output Power (Watts)  
10 This product is only for inclusion by professional installers within other  
equipment and must not be operated as a stand alone product.  
11 The EMI specifications reference measurements made with the power  
supply mounted on a grounded metal sheet extending 1 inch beyond each  
edge, using an unshielded cable. No external filtering is required during  
conducted emissions testing but some applications may require additional  
filtering to achieve system compliance. A line choke, (AC input cords  
looped twice through an EMI suppression toroid) was used during radiated  
emissions testing. Considerable radiated testing in 1U six-sided boxes has  
shown that units can meet level B in typical systems. Application support  
is available from the factory to assist with EMI compliance.  
110W  
80W  
150 LFM FORCED  
AIR COOLING  
NATURAL  
CONVECTION  
COOLING  
55W  
40W  
12 Requires a minimum mounting stand-off of 6.35mm (0.25 inches) in the end  
use product.  
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C  
OUTPUT PIN CONNECTIONS  
INPUT  
PIN CONNECTIONS  
J 1  
J 2  
FUNCTION  
+5.1V  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Pin 6  
Pin 7  
Pin 8  
Pin 9  
Pin 10  
Pin 11  
Pin 12  
+5.1V  
Pin 1  
AC Neutral  
No Connection  
AC Line  
Return  
Return  
Return  
Return  
+12V  
Pin 2  
Pin 3  
Power fail detect signal  
50msT1200ms  
OPTIONAL POWER FAIL DETECT TIMING DIAGRAM  
T2 will vary with line and load  
AC INPUT  
J 4  
T33ms  
4.75V  
4.75V  
5V OUTPUT  
PFD SIGNAL  
Pout: 110W  
Pin 1  
Safety Earth  
HIGH  
PFD output is an open collector  
which will sink 40mA in the low  
state.  
3.5V MIN  
T3  
LOW  
0-0.4 MAX  
T2  
T1  
+12V  
+24V  
PFD  
-12V Return  
-12V  
Please consult our website for the following items: Application Note  
www.a rte s yn.com  
File Name: NLS110.PDF Rev: 12 June 2001  
NLS110-9602  
Q u a d o u t p u t  
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies  
3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm  
Mechanical Notes  
A
All dimensions are in inches (mm).  
2
7.00 (177.80)  
6.500 (165.100)  
4
3
J4  
1
T1 (REF)  
12  
Recommended direction  
for forced air relative to  
power supply orientation  
shown below.  
4.25  
(107.95)  
T2 (REF)  
3.750  
(95.250)  
J2  
1
2
3
4
Optimum.  
Very good.  
Not recommended.  
Not recommended.  
F1  
J1  
1
3
1
2
1
0.25 (6.35)  
0.25 (6.35)  
J5  
TOLERANCE: .XXX: ±0.005 (0.127)  
.XX: ±0.02 (0.51)  
ALL DIMENSIONS IN INCHES (mm)  
Input and output connectors  
Mating connectors  
AC (J 1) connector type  
AC (J 1) mating connector type  
Molex 26-60-4030 or equivalent.  
Molex 09-50-3031 or equivalent with Molex  
08-50-0105 or equivalent crimp terminals.  
DC (J 2) connector type  
12 position Molex Spox type 26-48-1125  
or equivalent.  
DC (J 2) mating connector type  
Molex Spox type 26-03-3121 and  
contact 08-52-0113.  
Earth (J 4) connector type  
Earth (J 4) mating connector type  
Male 0.250 quick disconnect.  
Molex 90028.  
International Safety Standard Approvals  
VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-1049  
Licence No. 2874, 1653 and 1049  
UL1950 File No. E136005  
CSA C22.2 No. 950 File No. LR41062C  
Data Sheet © Artesyn Technologies  
® 2002  
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising  
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.  
Please consult our website for the following items: Application Note  
www.a rte s yn.com  
File Name: NLS110.PDF Rev: 12 June 2001  

相关型号:

NLS110-9602J

80-110 W AC/DC Universal Input Switch Mode Power Supplies
ARTESYN

NLS110-9602J

80-110 W AC/DC Universal Input Switch Mode Power Supplies
EMERSON-NETWO

NLS12

Fuse
ETC

NLS125

Electric Fuse, 125A, 600VAC, 600VDC, 50000A (IR), Inline/holder,
LITTELFUSE

NLS15

Fuse
ETC

NLS150

Electric Fuse, 150A, 600VAC, 600VDC, 50000A (IR), Inline/holder,
LITTELFUSE

NLS160806T-010J

General Purpose Inductor, 0.01uH, 5%, 1 Element, Air-Core, SMD
TDK

NLS160806T-1N0

General Purpose Inductor, 0.001uH, 5%, 0603
TDK

NLS160806T-1N0D

General Purpose Inductor, 0.001uH, 1 Element, Air-Core, SMD
TDK

NLS160806T-1N2D

General Purpose Inductor, 0.0012uH, 1 Element, Air-Core, SMD
TDK

NLS160806T-1N5D

General Purpose Inductor, 0.0015uH, 1 Element, Air-Core, SMD
TDK

NLS160806T-1N8D

General Purpose Inductor, 0.0018uH, 1 Element, Air-Core, SMD
TDK