UMP04C-S2E-S2Q-S2Q-20-A [ARTESYN]

UMP CONFIG PWR SUPPLY 4SLOT CONN;
UMP04C-S2E-S2Q-S2Q-20-A
型号: UMP04C-S2E-S2Q-S2Q-20-A
厂家: ARTESYN TECHNOLOGIES    ARTESYN TECHNOLOGIES
描述:

UMP CONFIG PWR SUPPLY 4SLOT CONN

文件: 总15页 (文件大小:2530K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
ARTESYN μMP SERIES  
GEN II  
Up to 1800 Watts with New Product  
Enhancements  
Advanced Energy's Artesyn μMP series GEN II power supply  
is a configurable power supply with market-leading density  
and efficiency. It features a very wide 85 to 264 Vac input  
voltage range and employs active power factor correction  
to minimize input harmonic current distortion and to ensure  
compliance with the international EN61000-3-2 standard –  
they have a power factor of 0.99 typical. The power supplies  
also feature active AC inrush control to automatically limit  
inrush current at turn-on to 40 A maximum.  
AT A GLANCE  
Total Power:  
Up to 1800 Watts Peak*  
Input Voltage:  
85 - 264 Vac  
120 - 300 Vdc  
# of Outputs:  
Up to 12  
Military STD shock/vibration (40G’s)  
SPECIAL FEATURES  
Low cost  
Full Medical EN60601 approval  
IEC, terminal block or barrier strip  
* Max output power for μMP16: 1000 W  
90 - 100 VAC; 1200 W 100 - 180 VAC;  
1600 W 180 - 200 W; 1800 W 200 -  
264 VAC. Operational specs for EMI  
and Hold-up are valid to 1600 W max.  
PMBus monitor/control of input  
functions  
input connection options  
Low profile 1U size  
High efficiency  
Superior aesthetics over GEN I  
Constant current limit protection  
High power density.  
· μMP04: 10.8 W/cu-in  
· μMP09: 18.5 W/cu-in  
· μMP10: 15.1 W/cu-in  
· μMP16: 22.9 W/cu-in  
CERTIFICATIONS  
UL  
UL/CSA 62368-1  
ES60601-1 / CSA 22.2  
No.60601-1  
Low noise intelligent fan (speed  
control/fault status), 36% reduction  
from GEN I  
TUV  
CB  
CE  
EN62368-1 / EN60601-1  
Certificate and Report  
Compliance to LVD and  
RoHS Directives  
Downloadable GUI from website  
Optional conformal coating  
CQC  
Approved  
Industrial temp range (-40 ºC to  
70 ºC)  
Medical 2x MOPP  
** μMP tested according to the medical  
standard IEC 60601-1-2 4th Edition.  
No preload required  
©2021 Advanced Energy Industries, Inc.  
μMP  
ELECTRICAL SPECIFICATIONS  
Input  
Input range  
Frequency  
Inrush current  
Efficiency  
85 - 264 Vac, 120 - 350 Vdc (limited to 300 Vdc in medical applications)  
47 - 440 Hz  
40 A peak max. (soft start)  
Up to 91.5% @ full case load  
Power factor  
Standby power  
0.99 typ. meets EN61000-3-2 (n/a @ 440 Hz)  
uMP10/16 < 13 W  
uMP04/09 < 6 W  
Turn-on time  
EMI:  
AC on 2 sec for μMP16/10 and 1.5 sec for μMP04/09, inhibit/enable 250 ms typical  
CISPR 22/EN55022 Level “B” (Both Conducted and Radiated)  
Leakage current  
<200 uA using center-tapped xfmr measurement method.  
(<400 uA @ 264 VAC input)  
Holdover storage  
AC OK  
16.7 ms minimum (independent of input Vac, 0 °C to 50 °C)  
At 1200 W for μMP16  
Signal goes low indicating loss of AC input.  
Hold up = Full cycle ride thru (50 Hz); Open collector  
Harmonic current emission  
Isolation  
Meets EN61000-3-2  
Meets EN62368 and EN60601  
Global inhibit/enable  
Input fuse (internal)  
Warranty  
TTL, Logic “1” and Logic “0”; fan off when unit is inhibited  
μMP16/10: 16 A, 500 Vac, 400 Vdc, μMP04/09: 10 A / 250 V. (both lines fused)  
3 years  
Output  
Factory set point accuracy  
Margining / V-Program  
1%  
3 - 7% nominal analog (single output module only). Contact factory for simple V-program  
modification (i.e. 0-5 V input = 0-100% output voltage).  
Overall regulation  
Ripple  
0.4% or 30 mV which ever is greater  
RMS: 0.1% or 10 mV, whichever is greater  
Pk-Pk: 1.0% or 50 mV, whichever is greater. Bandwidth limited to 20 MHz  
Dynamic response  
Recovery time  
<
5% or 250 mV, with 50% step load, Min 20% load condition  
To within 1% in < 300 μsec  
Reverse voltage protection  
Thermal protection (OTP)  
Remote sense  
100% of rated output current  
All outputs disabled when internal temp exceeds safe operating range  
Up to 0.5 V total drop (not available on triple output module)  
Current share to within 5% of total rated current from 20% to 100% rated load  
5% of nominal Open collector  
Single wire parallel  
DC OK  
Minimum load  
Not required  
Housekeeping standby  
5 Vdc @ 2.0 A max whenever AC input is applied. 1.0 A (2.0 A for μMP04) max convection cooled  
(when output is inhibited off)  
Module inhibit  
Logic - output on with low or open. Different logic options available  
> 1 Megohm, 500 V  
Output/Output isolation  
2
advancedenergy.com  
μMP  
ENVIRONMENTAL SPECIFICATIONS  
Operating temperature  
-40 °C to 70 °C ambient. Derate each output 2.5% per degree from 50 °C to 70 °C. Cold start soak  
-20 °C, allow 10 min warm-up before all outputs are within specification. Reverse air to 40 °C Max due  
to fan derating.  
Storage temperature  
Electromagnetic susceptibility  
Humidity  
-40 °C to +85 °C  
Designed to meet EN61000-4:-3,-5,-6,-11 Class 3 Performance Criteria A  
Operating; non-condensing 10% to 95% RH  
Vibration  
MIL-STD-810E  
MTBF demonstrated  
Altitude  
> 350,000 hours at full load, one μMP04 case + two modules, Telcordia SR-332 calculated MTBF  
Up to 10 K feet; derate linear to 50% from 10 K - 30 K feet  
Vout  
Full load (A) OVP trip max (V) OCP trip typ (Iout%) SCP trip max (Iout%) Overshoot (max mV) Peak Deviation (max mV)  
3 V 3 Module  
0.9  
40  
40  
40  
2.00 V  
5.96 V  
6.31 V  
130%  
130%  
130%  
160%  
160%  
160%  
150  
250  
250  
250  
250  
250  
3.3  
3.6  
5 V Module  
3.2  
36  
36  
30  
5.76 V  
9.0 V  
130%  
130%  
130%  
160%  
160%  
160%  
250  
250  
300  
250  
250  
300  
5
6
10.80 V  
12 V Module  
6
25  
20  
16  
10.80 V  
15.60 V  
19.50 V  
130%  
130%  
130%  
160%  
160%  
160%  
300  
600  
750  
300  
600  
750  
12  
15  
24 V Module  
12  
13  
10  
8
15.60 V  
31.20 V  
39.00 V  
130%  
130%  
130%  
160%  
160%  
160%  
600  
120  
600  
1200  
1500  
24  
30  
1500  
48 V Module  
28  
48  
60  
7
5
4
36.40 V  
62.40 V  
78.00 V  
130%  
130%  
130%  
200%  
160%  
200%  
1400  
2400  
3000  
1400  
2400  
3000  
advancedenergy.com  
3
μMP  
CASE LINE-UP  
Max Output  
180-263 VAC  
Max Continous  
Current  
Case  
Dimensions  
Connections  
85-180 VAC  
256.9 x 88.9 x 40.0  
(10.11” x 3.5” x 1.57”)  
IEC, Terminal-Block,  
Barrier-Strip  
μMP04 - 4 Slot  
μMP09 - 4 Slot  
μMP10 - 6 Slot  
μMP16 - 6 Slot  
400 W  
600 W  
1100 W  
1200 W  
1800 W  
9.91  
9.91  
256.9 x 88.9 x 40.0  
(10.11” x 3.5” x 1.57”)  
IEC, Terminal-Block,  
Barrier-Strip  
550 W  
1000 W  
1000 W  
256.9 x 127 x 40.0  
(10.11” x 5.0” x 1.57”)  
IEC, Terminal-Block,  
Barrier-Strip  
13.87  
13.87  
256.9 x 127 x 40.0  
(10.11” x 5.0” x 1.57”)  
IEC, Terminal-Block,  
Barrier-Strip  
OUTPUT MODULE LINE-UP S2*  
Output Range (Vdc)  
0.9 - 3.6  
Max Current (Amps)  
Max Power (Watts)  
Module Codes Standard Outputs  
A, B, C, D - 2, 2.2, 3, 3.3  
40  
36  
25  
13  
7
144  
180  
240  
240  
240  
3.2 - 6.0  
E, F, G, H - 5, 5, 2, 5.5, 6.0  
6.0 -15.0  
I, J, K, L, M, N - 8, 10, 11, 12, 14, 15  
O, P, Q, R, S - 18, 20, 24, 28, 30  
T, U, V, W, X, Y - 33, 36, 42, 48, 54, 60  
12.0 - 30.0  
33.0 - 60.0  
Dual Output Module. Each output is rated to 96 W (192 Watts total).  
Wide range is adjustable.  
3.3 - 30.0  
4/4  
96/96  
DC OUTPUT MODULE RATING (SK*) 3-SLOTS  
Output (Vdc)  
6.0 – 15.0  
MAX Current (Amps)  
MAX Power (Watts)  
Modules Codes (*) Standard Outputs  
H, I, J, K, L, M, N – 6, 8, 10, 11, 12, 14, 15  
O, P, Q, R, S – 18, 20, 24, 28, 30  
84  
42  
21  
1000  
1000  
1000  
12.0 – 30.0  
28.0 – 60.0  
T, U, V, W, X, Y – 33, 36, 42, 48, 54, 60  
INTERNAL PART NUMBER REFERENCE TABLE  
Part #  
Where X =  
T, C, S  
Description  
μMP10 Cases  
Module Code  
μMP10  
73-951-0001X-G2  
73-956-0001X-G2  
73-963-XXXX  
T, C, S  
μMP16 Cases  
μMP16  
0012, 0024, 0048, 04XX  
0012, 0024, 0048, 04XX  
uMP 1000W Module  
uMP 1000W Module  
SKL - SKZ  
SKL - SKZ  
73-963-00XX-G2  
4
advancedenergy.com  
μMP  
ORDERING INFORMATION  
μMPXY  
-
SKW - S2E - S2Q - ILL  
-
00  
-
A
-
###  
Module Codes:  
First digit  
0-9 = Parallel Code  
Factory assigned  
for modified  
standards  
Case Size  
1-Phase Input where X =  
S2 = 200 W Single O/P (1 Slot)  
SK = 1000 W Single O/P (3 Slot)  
I = 96 W Dual O/P ISO GND (1  
Slot)  
HUP = Hold-Up Module  
(10ms for 500W /1 Slot)  
04 = 1.57” x 3.5” x 10.0”; 400W - 600W 4 Slots  
09 = 1.57 x 3.5 x 10.0, 550W-1100W 4 Slots  
10 = 1.57 x 5.0” x 10.0”, 1000W-1200W, 6 Slots  
16 = 1.57” x 5.0” x 10.0”, 1200W-1800W**, 6  
Slots  
Second Digit  
0 = No Options  
1 = Reverse Air  
2 = Not Used  
3 = Global Enable  
5 = Opt 1 + Opt 3  
** See Output derating table below for uMP16  
Voltage Codes: See voltage  
code table  
Input Type where Y =  
T = Terminal Block  
C = IEC Connector C14  
S = Barrier Strip  
μMP16 OUTPUT POWER DERATING  
Paramater  
Designed For  
85 - 99 Vac  
1000 W  
100 - 140 Vac  
1200 W  
180 - 199 Vac  
1600 W  
200 - 264 Vac  
1800 W  
QAV Evaluation  
1000 W  
1200 W  
1600 W  
1800 W  
Safety Label and Evaluation  
1000 W  
1000 W  
1600 W  
1600 W  
PARALLEL CODES  
Code  
Slots in Parallel  
Code  
Slots in Parallel  
1&2&3  
Code  
Slots in Parallel  
Code  
Slots in Parallel  
no module in parallel  
3,4&5  
1
2
3
4
5
1&2  
2&3  
3&4  
4&5  
5&6  
6
7
8
9
A
B
C
D
E
1&2; 3&4  
1,2&3; 4&5  
0
H
J
1,2,3&4  
1,2,3,4&5  
1,2,3,4,5&6  
1,2,3&4; 5&6  
1&2; 3&4; 5&6  
1,2&3; 4,5&6  
3,4,5&6  
K
4,5&6  
Notes:  
Parallel between SK* (1000 W Modules) and S2* (240 W Modules) will use the codes as follows  
Code 3 to parallel 2 SK* modules  
Code 3 to parallel 1 SK* module and 1 S2* module  
Code H to parallel 1 SK* module and 2 S2* modules  
advancedenergy.com  
5
μMP  
VOLTAGE CODES  
Standard Output Ratings  
Module Output  
Voltage Code  
Single Output One Slot 240 Watts  
Max  
Single Output Three Slots 1000  
Watts Max  
Dual Output One Slot  
96 Watts  
Module  
Identification  
S2  
SK  
I
Output Current  
Output Current  
V1  
Output Current  
V1  
Code  
Volts  
V1  
V2  
A
B
C
D
E
2.0  
2.2  
40.0  
40.0  
40.0  
40.0  
36.0  
34.0  
32.0  
30.0  
25.0  
24.0  
22.0  
20.0  
17.0  
16.0  
13.0  
12.0  
10.0  
8.6  
-
NA  
NA  
NA  
-
3.0  
-
3.3  
-
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
3.4  
3.2  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
4.0  
3.4  
3.2  
5.0  
-
F
5.2  
-
G
H
I
5.5  
-
6.0  
84.0  
84.0  
84.0  
84.0  
84.0  
71.4  
66.7  
42.0  
42.0  
42.0  
35.7  
33.3  
21.0  
21.0  
21.0  
21.0  
18.5  
16.7  
8.0  
J
10.0  
11.0  
12.0  
14.0  
15.0  
18.0  
20.0  
24.0  
28.0  
30.0  
33.0  
36.0  
42.0  
48.0  
54.0  
60.0  
K
L
M
N
O
P
Q
R
S
T
8.0  
7
NA  
NA  
NA  
NA  
NA  
NA  
U
V
W
X
Y
6.7  
5.7  
5.0  
4.4  
4.0  
6
advancedenergy.com  
μMP  
DERATING CURVES - MP10  
Standard Fan (12 V/24 V/48 V)  
Reverse FAN (12 V/24 V/48V)  
85 VAC  
100 VAC  
110 VAC  
200 VAC  
264 VAC  
85 VAC  
100 VAC  
110 VAC  
200 VAC  
264 VAC  
1200  
1100  
1000  
900  
1200  
1100  
1000  
900  
800  
800  
700  
700  
600  
600  
500  
500  
400  
400  
0
10  
20  
30  
40  
50  
60  
7 0  
0
10  
20  
30  
40  
50  
60  
70  
Temperature  
Temperature  
μMP04/09 (AC input on opposite side)  
μMP10/16 (AC input on opposite side)  
S
L
O
T
6
S
L
O
T
5
S
L
O
T
4
S
L
O
T
3
S
L
O
T
1
S
L
O
T
2
S
L
O
T
S
L
O
T
S
L
O
T
S
L
O
T
J2  
J1  
J2  
J1  
4
2
1
3
Input  
Input  
85 - 264 Vac  
400 W max.  
550 W max.  
200 - 264 Vac  
600 W max.  
1100 W max.  
85 - 264 Vac  
1000 W max.  
1200 W max.  
200 - 264 Vac  
1200 W max.  
1800 W max.  
μMP04 = 4 available slots  
μMP09 = 4 available slots  
μMP10 = 6 available slots  
μMP16 = 6 available slots  
advancedenergy.com  
7
μMP  
PIN CONNECTORS  
Mates with  
Landwin 2050S1000 Housing  
2053T011V Pin  
Figure 1. AC Input  
J2  
AC Input  
I2C Bus Output Connector  
Pin Function  
Pin Function  
IEC Connector  
or  
1
2
3
AC neutral  
1
2
3
4
5
6
7
8
9
5 Vcc bus  
JST PHDR-10VS Housing  
JST SPHD-002T-P0.5 (28-24)  
JST SPHD-001T-P0.5 (26-22)  
AC line (hot)  
Serial data signal (SDA)  
Secondary return (COM)  
Serial clock signal (SCL)  
Address bit 2 (A2)  
No connection  
Terminal Block  
Chassis (earth) ground  
PEN L  
J1  
Connector Kit Part No.:  
70-841-023  
PFC Input Connector  
(control & signals)  
Pin Function  
Address bit 1 (A1)  
No connection  
1
2
3
4
5
6
7
8
9
Input AC OK - “emitter”  
Input AC OK - “collector”  
Global DC OK - “emitter”  
Global DC OK - “collector”  
Spare  
Address bit 0 (A0)  
10 No connection  
9
10  
1
2
Global inhibit/optional enable logic “1”  
Global inhibit/optional enable logic “0”  
Global inhibit/optional enable return  
+5 VSB housekeeping  
Figure 2. Connector J1 & J2  
10 +5 VSB housekeeping return  
S2 MODULE  
240 W  
DC Output Control & Signals (Single output)  
Pin Function  
1
2
3
4
5
6
7
8
9
No connection  
No connection  
Current share  
Module inhibit return  
Module ISO inhibit  
SCOM  
-RMT sense  
Margin  
V ADJ  
2.3 0.2  
1.0 0.ꢀ2  
Remote margin / V prog.  
ꢀ9.8 0.ꢀ  
3ꢀ.2 0.3  
36.2 0.3  
10 +RMT sense  
37.2 0.3  
36.2 0.3  
V+  
V-  
CAPS HEIGHT  
4.2 0.3  
1ꢀ.2 MAX  
3.0 MAX  
0.8 - 1.2  
1.6 0.16  
9
10  
1
2
130.0 1.2  
8
advancedenergy.com  
μMP  
SK MODULE  
1000 W 48 V Outputs  
122.00 0.5  
1000 W 12/24 V Output:  
DC Output Control & Signals (Single output)  
Pin Function  
1
2
3
4
5
6
7
8
9
No connection  
No connection  
Current share  
Module inhibit return  
Module ISO inhibit  
SCOM  
-RMT sense  
Margin  
Remote margin / V prog.  
10 +RMT sense  
advancedenergy.com  
9
μMP  
DUAL MODULE  
DC Output Control & Signals (Dual output)  
Pin Function  
1
2
3
4
5
6
7
8
9
-RMT sense V2  
+RMT sense V2  
No connection  
Module inhibit rtn  
Module ISO inhibit  
SCOM  
-RMT sense V1  
No connection  
No connection  
10 +RMT sense V1  
10 advancedenergy.com  
μMP  
μMP SERIES  
μMP04/09 (400/600; 550/1100 Watts Max)  
Case Size: μMP04/09: 10.11” x 3.5” x 1.57” (256.9 mm x 88.9 mm x 40.0 mm)  
Weight: μMP04/09 Case: 1.96 lbs • Single O/P: 0.22 lb.  
• Dual O/P: 0.16 lb. • Blank: 0.06 lb.  
Notes:  
1. Input: IEC 60320 C13 (for IEC connector)  
Barrier Type DECA Switchlab MT300-50003 (for terminal block connector); Max Torque: 4.0 lb-in (0.4 - 0.5 Nm); Wire: 12 - 16 AWG; Wire Strip Length: 0.354” (9.0 mm)  
2. Control Connectors (J1 and J2): 10-position housing, brass, matte tin-plated contacts. Mates with housing 2050S1000 (Landwin) with 2053T011P (Landwin) pins or housing  
PHDR-10VS (JST) and SPHD- 002T-PO.5 (JST) pins.  
3. Output Module Connectors: All single O/P modules are M4 x 10 mm screws; tighten between 6.94 to 8.68 lb-in (8.0 to 10.0 kg-cm). Dual O/P module is PUSH IN conductor connector;  
Wire Strip Length: 0.315” (8.0 mm); Control signal connector: Refer to Item 2.  
4. Chassis Material: Steel with chemical film coating (conductive).  
5. Customer Mounting: Screw M4-type mounting holes; Max. Penetration is 0.138” (3.5 mm); Max. Torque: 8.85 lb-in (1.0 N-m)  
6. All dimensions are in millimeters and inches, and are typical.  
advancedenergy.com  
11  
μMP  
μMP SERIES (CONTINUED)  
μMP10 (1000/1200 Watts Max)  
μMP16 (1200/1800 Watts Max)  
Case Size: μMP10/16: 10.11” x 5” x 1.57” (256.9 mm x 127 mm x 40.0 mm)  
Weight: μMP10/16 Case: 2.78 lbs • Single O/P: 0.22 lb.  
• Dual O/P: 0.16 lb. • Blank: 0.06 lb.  
Notes:  
1. Input: IEC 60320 C13 (for IEC connector)  
Barrier Type DECA Switchlab MT300-50003 (for terminal block connector); Max Torque: 4.0 lb-in (0.4 - 0.5 Nm); Wire: 12 - 16 AWG; Wire Strip Length: 0.354” (9.0 mm)  
2. Control Connectors (J1 and J2): 10-position housing, brass, matte tin-plated contacts.Mates with housing 2050S1000 (Landwin) with 2053T011P (Landwin) pins or housing  
PHDR-10VS (JST) and SPHD-002T-PO.5 (JST) pins.  
3. Output Module Connectors: All single O/P modules are M4 x 10 mm screws; tighten between 6.94 to 8.68 lb-in (8.0 to 10.0 kg-cm). Dual O/P module is PUSH IN conductor connector;  
Wire Strip Length: 0.315” (8.0 mm); Control signal connector: Refer to Item 2.  
4. Chassis Material: Steel with chemical film coating (conductive).  
5. Customer Mounting: Screw M4-type mounting holes; Max. Penetration is 0.138” (3.5 mm); Max. Torque: 8.85 lb-in (1.0 N-m)  
6. All dimensions are in millimeters and inches, and are typical.  
12 advancedenergy.com  
μMP  
μMP HUP MODULE  
The μMP HUP module is intended for use on μMP09 with high efficiency module (SK*) configurations. In such case, only  
one HUP can be used per case.  
Its application is limited with μMP09 and μMP04 configurations and may have multiple HUP’s inserted.  
The HUP module shall provide additional 224μF bulk capacitance (typ.). Typical hold-up time increase with HUP module  
in μMP09 case and SK* module is 10ms at 500W load.  
73-950-002  
Actual μMP HUP Module and μMP09 Configuration  
μMP09 Config with HUP at Slot1  
Typical HUP Response with μMP09-SKW Configuration  
advancedenergy.com  
13  
μMP  
μMP HUP MODULE (CONTINUED)  
Typical HUP Response with μMP09-S2* Configuration  
14 advancedenergy.com  
ABOUT ADVANCED ENERGY  
Advanced Energy (AE) has devoted more than three  
decades to perfecting power for its global customers. AE  
designs and manufactures highly engineered, precision  
power conversion, measurement and control solutions for  
mission-critical applications and processes.  
Our products enable customer innovation in complex  
applications for a wide range of industries including  
semiconductor equipment, industrial, manufacturing,  
telecommunications, data center computing, and medical.  
With deep applications know-how and responsive service  
and support across the globe, we build collaborative  
partnerships to meet rapid technological developments,  
propel growth for our customers, and innovate the future  
of power.  
For international contact information,  
visit advancedenergy.com.  
Specifications are subject to change without notice. Not responsible  
for errors or omissions. ©2021 Advanced Energy Industries, Inc. All rights  
reserved. Advanced Energy®, AE® and Artesyn™ are U.S. trademarks  
of Advanced Energy Industries, Inc.  
powersales@aei.com (Sales Support)  
productsupport.ep@aei.com (Technical Support)  
+1 888 412 7832  
ENG-μMP-235-01 8.26  

相关型号:

UMP04C-S2E-S2Q-S2Q-INN-23-A

UMP CONFIG PWR SUPPLY 4SLOT CONN
ARTESYN

UMP04C-S2E-S2Z-S2Z-20-B

UMP CONFIG PWR SUPPLY 4SLOT CONN
ARTESYN

UMP04C-S2L-S2M-S2M-00-A

UMP CONFIG PWR SUPPLY 4SLOT CONN
ARTESYN

UMP04C-S2L-S2N-S2Q-00-A

UMP CONFIG PWR SUPPLY 4SLOT CONN
ARTESYN

UMP04C-S2L-S2Q-00-A

UMP CONFIG PWR SUPPLY 4SLOT CONN
ARTESYN

UMP04C-S2L-S2Q-S2Q-S2Q-00-A

UMP CONFIG PWR SUPPLY 4SLOT CONN
ARTESYN

UMP04C-S2N-S2T-S2T-20-B

UMP CONFIG PWR SUPPLY 4SLOT CONN
ARTESYN

UMP04C-S2Q-IEJ-ILL-00-A

UMP CONFIG PWR SUPPLY 4SLOT CONN
ARTESYN

UMP04C-S2Q-INN-IRR-00-A

UMP CONFIG PWR SUPPLY 4SLOT CONN
ARTESYN

UMP04C-S2Q-S2Q-10-A

UMP CONFIG PWR SUPPLY 4SLOT CONN
ARTESYN

UMP04C-S2Q-S2Q-S2Q-60-A

UMP CONFIG PWR SUPPLY 4SLOT CONN
ARTESYN

UMP04C-S2Q-S2S-INN-03-A

UMP CONFIG PWR SUPPLY 4SLOT CONN
ARTESYN