LPS110 [ASTEC]
110 Watts; 110瓦Total Power: 80-110 Watts
Input Voltage: 85-264 VAC
120-300 VDC
110 Watts
# of Outputs: Single
LPS110 Series
Electrical Specs
Input
Input range
85-264 VAC
120-300 VDC
Frequency
47-440 Hz
Inrush current
<18 A peak @ 115 VAC;
<36 A peak @ 230 VAC,
cold start @ 25°C
Input current
Efficiency
EMI filter
2.5 A max. (RMS) @ 115 VAC
70% typical at full load
FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
Special Features
Safety ground
leakage current
•
•
•
•
•
•
•
•
•
•
•
Universal input
High efficiency
<0.5 mA @ 50/60 Hz, 264 VAC-input
Output
Maximum power
Remote sense
Built-in EMI filter
80 W for convection;
110 W with 30 CFM forced air
Low output ripple
Adjustable output
Power fail
Overvoltage protection
Overload protection
Optional L bracket (-B suffix)
Cover kit available LPX110-C
Adjustment range
Hold-up time
±5% minimum
20 ms @80 W load, 115 VAC nominal
line
Overload protection
Short circuit protection. Case overload
protected @ 110-145% above peak
rating
Overvoltage protection
5 V output: 5.7-6.7 VDC. Other outputs
10% to 20% above nominal output.
Latching type, recycle AC to reset.
Environmental
Logic Control
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from
50° to 70°C
Power failure
TTL logic signal goes high 50-150 msec
after main output. It goes low at least 4
msec before loss of regulation.
Remote sense
Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection
protected.
Electromagnetic susceptibility: Designed to
meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.75 G peak 5 Hz to 500 Hz, operational
Safety
VDE
UL
CSA
0805/EN60950 (IEC950) 11774-3336-1245 (LC #84997)
Storage temperature: -40° to 85°C
UL1950
E132002
Temperature coefficient: ±.04% per °C
CSA 22.2-234 Level 3
LR53982C
P95100376
NEMKO EN 60950/EMKO-TUE
MTBF demonstrated: >550,000 hours at full load
and 25°C ambient conditions
(74-sec) 203
CB
CE
Certificate and report
Mark (LVD)
1563, 1564, 1565, 1566, 1567
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662
100
rev 12.10.03
ASIA
EUROPE
AMERICAS
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Ordering Information
Model
Number
Output
Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load with
30 CFM Forced Air
Peak
Load1
Regulation2
Ripple
P/P (PARD)3
LPS113
LPS114
LPS115
LPS118
12 V
15 V
24 V
48 V
0 A
0 A
0 A
0 A
6.7 A
5.3 A
3.3 A
1.7 A
9.2 A
7.3 A
4.6 A
2.3 A
10.4 A
8.3 A
5.2 A
2.6 A
±2%
±2%
±2%
±2%
120 mV
150 mV
240 mV
480 mV
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load.
Note: -B suffix added to model number indicates L bracket option.
-B Bracket
Pin Assignments
#6-32 PEM
6 places
4.28"
(108.6)
ConnectorLPS113
LPS114
LPS115
LPS118
2.5"
(63.5)
SK1-1
SK1-3
SK1-5
GND
Neutral
Line
GND
Neutral
Line
GND
Neutral
Line
GND
Neutral
Line
SK2-1
SK2-2
SK2-3
SK2-4
SK2-5
SK2-6
SK2-7
SK2-8
SK2-9
+12 V
+12 V
+12 V
+15 V
+15 V
+15 V
+24 V
+24 V
+24 V
+48 V
+48 V
+48 V
6.4"
(162.6)
7.3"
(185.5)
Common Common Common Common
Common Common Common Common
Common Common Common Common
Common Common Common Common
+12 V
+12 V
2.2"
(56)
+15 V
+15 V
+sense
-sense
Pok
+24 V
+24 V
+sense
-sense
Pok
+48 V
+48 V
+sense
-sense
Pok
0.86"
(21.8)
SK201-1 +sense
SK201-2 -sense
SK202-1 Pok
5.9"
(150.0)
SK202-2 GND
GND
GND
GND
0.25"
(6.35)
Mating Connectors
SK 202
(POK)
AC Input:
Molex 09-50-8051 (USA)
09-91-0500 (UK)
M2
1
2
SK 201
1
(+S) 1
2
PINS: 08-58-0111
(-S) 2
3
4
5
6
7
8
9
DC Outputs:
Molex 09-50-8091 (USA)
09-91-0900 (UK)
PINS: 08-58-0111
4.0"
(101.6)
3.5"
Remote sense/power fail:
Molex 22-01-1022 (USA)
(88.9)
1
3
22-01-1023 (UK)
PINS: 08-50-0114
GND
N
L
Astec Connector Kit #70-841-007, includes all of the above
SK 1
M1
0.156" (4)
DIA (4 places)
6.5"
(165.1)
0.25"
(6.35)
Notes:
7.0"
(177.8)
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±.02”.
3. Specifications are for convection rating at factory settings unless
otherwise stated.
4. Mounting holes M1 and M2 should be grounded for EMI purposes.
5. Mounting hole M1 is safety ground connection.
6. L Bracket mounting (6-32) maximum insertion depth is .20” (5).
7. Warranty: 1 year
1.80"
(45.7)
8. Weight: 1.25 lb / 0.57 kg
0.12"
(3)
www.astecpower.com
101
相关型号: