Total Power: 250 Watts
Input Voltage: 85-264 VAC
120-300 VDC
250 Watts
# of Outputs: Single
LPS250 Series
Electrical Specs
Input
Input range
Frequency
Inrush current
Efficiency
85-264 VAC; 120-300 VDC
47-440 Hz
20 A max., cold start @ 25°C
75% typical at full load
EMI filter
FCC Class B conducted and radiated
CISPR 22 Class B conducted and
radiated EN55022 Class B conducted
and radiated VDE 0878 PT3 Class B
conducted and radiated
0.99 typical
Power factor
Safety ground
leakage current
<0.5 mA @ 50/60 Hz, 264 VAC input
Special Features
Output
Maximum power
With cover: 250 W with 30 CFM forced
air.
(-C) (-CF) (CEF)
2:1 wide ratio
5 V @ 100 mA regulated; 12V @ 500
mA
20 ms @ 250 W load, 115 VAC nominal
line
at factory voltage setting
Short circuit protection on all outputs.
Case overload protected @ 110-145%
above peak rating
5 V output: 5.7 to 6.7 VDC.
Other models 10% to 25% above
nominal output
• Active power factor correction
• IEC EN6100-3-2 compliance
• Remote sense & remote inhibit
• Power fail
• Single wire current sharing
• Built-in EMI filter
Adjustment range
Supervisory output
Hold-up time
• Low output ripple
• 2 Supervisory outputs 5 V and 12 V
• Overvoltage protection
• Overload protection
• Thermal overload protection
• DC power good
Overload protection
Overvoltage protection
• Cover -C
• 120 kHz switching frequency
• Optional top with fan cover -CF
• Optional end fan cover -CEF
Logic Control
Power failure
TTL logic signal goes high 50-150 msec
after 5 V output. It goes low at least 4
msec before loss of regulation
Requires an external contact (N.O or
N.C) to inhibit outputs
TTL logic goes high 50-150 msec after
the output. It goes low when there is
loss of regulation.
Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection
protected.
Environmental
Remote on/off
DC-OK
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from 50° to
70°C
Electromagnetic susceptibility: Designed to meet
IEC 801, -2, -3, -4, -5, -6, Level 3
Remote sense
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.7 G peak 5 Hz to 500 Hz, operational
Safety
VDE
UL
CSA
0805/EN60950 (IEC950)
11774-3336-1262
E132002
LR53982C
Storage temperature: -40° to 85°C
Temperature coefficient: .04% per °C
UL1950
CSA 22.2-234 Level 5
NEMKO EN 60950/EMKO-TUE
P95103550
MTBF demonstrated: >550,000 hours at full load
and 25°C ambient conditionsation
(74-sec) 203
CB
CE
Certificate and report
Mark (LVD)
2186
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662
124
rev 04.07.05
ASIA
EUROPE
AMERICAS
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Kwai Fong, New Territories
Hong Kong
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Ordering Information
Model
Number
Output
Voltage
Minimum Maximum Load with
Peak
Load1
Regulation2
Ripple
P/P (PARD)3
Load
30 CFM Forced Air
LPS252-C
LPS253-C
LPS254-C
LPS255-C
5 V (3-6 V)
12 V (6-12 V)
15 V (12-24 V)
1.50 A
0.63 A
0.50 A
50 A
21 A
16.7 A
10.4 A
60 A
25 A
20 A
12.5 A
2%
2%
2%
2%
50 mV
120 mV
150 mV
240 mV
24 V ( 24-48 V) 0.32 A
Notes:
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. If optional CF or CEF fans are not used, 30CFM forced air cooling needs to be provided and is required through
the length of the power supply. Not convection rated.
5. Output voltage adjustment requires a minimum load.
6. Remote inhibit resets OVP latch
Note: -CF suffix added to the model number indicates cover with top fan.
-CEF suffix added to the model number indicates cover with dual end mounted fan cover and AC inlet.
6-32 (2 places)
Main Output
Output
Voltage
Adjust
M3 (4 places)
#6-32 UNC (8 places)
.24 (6.1)
Pin Assignments
SK3
Terminal
Block TB1
Connector
10.0
12345678
+ve -ve
SK5
SK1 PIN 1 Neutral
PIN 2 Line
10.0
SK4
FAN
PIN 3 Ground
3.68
(93.6)
SK7
SK3 PIN 1 + Remote sense
PIN 2 - Remote sense
PIN 3 Remote inhibit (N.O)
PIN 4 Remote inhibit (N.C)
PIN 5 Common
FAN
5.46
(138.6)
6.64
(168.6)
Optional
(-CF)
PIN 6 Current sharing
PIN 7 Power Fail
PIN 8 DC Power Good
3.15
(80)
8.52
(216.4)
Cover
with Fan
9.0
(228.6)
SK4 PIN 1 + Fan’s power source (12 V @ 500 mA)
PIN 2 - Fan’s power source (12 V @ 500 mA)
10.32
(262.0)
2.17
(55)
SK5 PIN 1 + Supervisory output supply (5 V @ 100 mA)
PIN 2 - Supervisory output supply (5 V @ 100 mA)
10.0
3
2
1
Optional
(-CEF)
1.18 (30.0)
SK7 PIN 1 + Fan’s power source (12 V @ 500 mA)
PIN 2 - Fan’s power source (12 V @ 500 mA)
6-32 (3 places)
Cover
SK1
with fans
5.0 (127.0)
Mating Connectors
SK3 Molex 22-01-1084
PINS:08-70-0057
2.0
(50.8)
3.0
(76.2)
SK4 Molex 22-01-3027
PINS: 08-50-0114
.55
(14)
1.30
(33.0)
SK5 Molex 22-01-3027
PINS: 08-50-0114
AC Inlet
SK7 Molex 22-01-3027
PINS: 08-50-0114
.79
(20)
3.42 (87.0)
Astec Connector Kit #70-841-005, includes all the above.
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is .02ꢀ.
3. Specifications are at factory settings.
4. To enable normally closed remote inhibit, cut
jumper J1.
5. Mounting maximum insertion depth is 0.12ꢀ.
6. Warranty: 1 year
7. Weight: 2.6 lb / 1.19 kg
www.astecpower.com