RD125-4824 [ASTRODYNE]
125W Dual Output Switching Power Supply;型号: | RD125-4824 |
厂家: | ASTRODYNE CORPORATION |
描述: | 125W Dual Output Switching Power Supply |
文件: | 总4页 (文件大小:317K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
125W Dual Output Switching Power Supply
RD125 series
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
All using 105°C long life electrolytic capacitors
Withstands 5G Vibration Test
High efficiency, long life and high reliability
Model Number Output Volts Output Amps
DUAL OUTPUT
Ripple & Noise
Min Load
Line Reg
Load Reg Volt Tolerance
RD125-A
5 Volts(DC)
12 Volts(DC)
5 Volts(DC)
24 Volts(DC)
12 Volts(DC)
24 Volts(DC)
12 Volts(DC)
48 Volts(DC)
24 Volts(DC)
48 Volts(DC)
24 Volts(DC)
12 Volts(DC)
48 Volts(DC)
12 Volts(DC)
48 Volts(DC)
24 Volts(DC)
7.7 Amps
7.7 Amps
4.6 Amps
4.6 Amps
3.7Amps
3.7 Amps
2.3 Amps
2.3 Amps
2.0 Amps
2.0 Amps
3.7Amps
3.7 Amps
2.3 Amps
2.3 Amps
2.0Amps
2.0 Amps
80mV pk-pk
120mV pk-pk
80mV pk-pk
120mV pk-pk
120mV pk-pk
200mV pk-pk
120mV pk-pk
240mV pk-pk
200mV pk-pk
240mV pk-pk
200mV pk-pk
120mV pk-pk
240mV pk-pk
120mV pk-pk
240mV pk-pk
240mV pk-pk
2.0~15Amps
0.5~10Amps
2~10Amps
±1.0%
±2.0%
±1.0%
±2.0%
±0.5%
±1.0%
±0.5%
±1.0%
±0.5%
±1.0%
±0.5%
±1.0%
±0.5%
±1.0%
±0.5%
±1.0%
±3.0%
±4.0%
±3.0%
±4.0%
±1.0%
±5.0%
±1.0%
±5.0%
±1.0%
±3.0%
±1.0%
±5.0%
±1.0%
±5.0%
±1.0%
±5.0%
±5.0%
±7.0%
±5.0%
±7.0%
±2.0%
+8,-5%
±2.0%
+8,-5%
±1.0%
±4.0%
±2.0%
±10%
RD125-B
0.4~5Amps
1.0~7Amps
0.4~5Amps
1.0~7Amps
0.2~2.5Amps
0.5~4Amps
0.2~2.5Amps
0.5~5Amps
1.0~7Amps
0.3~2.5Amps
1.0~7Amps
0.3~2.5Amps
0.5~4Amps
RD125-1224
RD125-1248
RD125-2448
RD125-2412
RD125-4812
RD125-4824
±2.0%
±10%
±1.0%
±8.0%
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
WWW.ASTRODYNETDI.COM
125W Dual Output Switching Power Supply
RD125 series
Efficiency (typ.)
Isolation
84%
INPUT SPECIFICATIONS
3000VAC Input - Output
1500VAC Input - Ground
500VAC Output - Ground
Compliance to
Input Voltage Range
Frequency Range
90 ~ 132 VAC; 176~264VAC selected
by switch; 248~373 Volts(DC)
47-63 Hz
EMS
Inrush Current, typ: (cold start) 40Amps / 230VAC
EN61000-4-2, 3, 4, 5, 6, 8, 11;
ENV50204, EN61000-6-2
(EN50082-2)
Input Current
3.0Amps. @ 115VAC
2.0 Amps. @ 230VAC
< 2mAmps /240VAC
Leakage current
Heavy Industry Level, Criteria A
OUTPUT SPECIFICATIONS
Voltage and Current
Line Regulation (Note 3)
Load Regulation (Note 4)
Voltage Tolerance (Note 2)
Ripple/Noise (Note 1)
ENVIRONMENTAL SPECIFICATIONS
See Selection Chart
See Selection Chart
See Selection Chart
See Selection Chart
See Selection Chart
25mS/230VAC
Oper. Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
RD125-A/B
-25°C to +70°C (See Derate Curve)
-40°C to +85°C, 10~95%
20~90% RH non cond
0.03% / °C (0-50°C) on +5V output
Hold Up Time @ FL
RD125-1224/1248 0.03% / °C (0-50°C) on +12V output
RD125-2448/2412 0.03% / °C (0-50°C) on +24V output
RD125-4812/4824 0.03% / °C (0-50°C) on +48V output
30mS/115VAC
500ms, 20m/230VAC
Setup, Rise Time @ FL
1200mS, 30mS/115VAC
Hiccup mode, auto recover
5Volts only: : 5.75 ~ 6.75Volts(DC)
12Volts only: : 13.8 ~ 16.2Volts(DC)
24Volts only: : 27.6 ~ 32.4Volts(DC)
48Volts only: : 55.2 ~ 64.8Volts(DC)
110 ~ 150% rated output power
Hiccup mode, auto recover
MTBF
RD125-A/B/ 2412/4812/4824 232.4 KHrs min, MIL-UDBK-217F(25°C)
Over Voltage Protection
RD125-A/B
RD125-1224/1248
RD125-2448/2412
RD125-4812/4824
Over Current Protection
RD125-1224/1248/2448
Vibration
232.4 KHrs min, MIL-UDBK-217F(25°C)
10~500Hz, 5G10min./1cycle, period for
60min. each along X, Y, Z axes
PHYSICAL SPECIFICATIONS
Size
DC Volt Adjust
Millimeters
Inches
Weight
199 x 98 x 38
7.83” x 3.86 ” x 1.49 ”
24.69 oz (700g)
RD125-A/B
5Volts only: 4.75 ~ 5.5Volts(DC)
12Volts only: 11.4~13.2Volts(DC)
24Volts only: 22.8~26.4Volts(DC)
40Volts only: 45.6~52.6Volts(DC)
RD125-1224/1248
RD125-2448/2412
RD125-4812/4824
NOTE
GENERAL SPECIFICATIONS
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Tolerance : includes set up tolerance, line regulation and load regula-
tion.
3. Line regulation is measured from low line to high line at rated load.
4. Load regulation is measured from 20% to 100% rated load, and other
output at 60% rated load.
Safety
UL60950-1,
TUV EN60950-1 Approved
≥ 100MΩ / 500Volts(DC)
Compliance to EN55022 (CISPR22)
Class B
Insulation Resistance
EMI
Harmonic Current
Compliance to EN61000-3-2,-3
All specifications are typical at nominal input, full load, and 25°C unless other-
wise noted
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
WWW.ASTRODYNETDI.COM
125W Dual Output Switching Power Supply
RD125 series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
WWW.ASTRODYNETDI.COM
125W Dual Output Switching Power Supply
RD125 series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
WWW.ASTRODYNETDI.COM
相关型号: