WSA 500 SERIES, 30 WATTS
HIGH EFFICIENCY, COMPACT DESIGN SWITCHMODE TECHNOLOGY
A-CASE
MODEL NUMBER
WSA533
WSA540
WSA545
WSA550
WSA555
WSA560
WSA565
WSA570
WSA575
WSA580
WSA590
WSA510
WSA511
WSA512
WSA513
WSA514
WSA515
WSA516
WSA518
WSA520
WSA522
WSA524
WSA526
WSA528
WSA530
WSA532
WSA536
WSA540
WSA544
WSA548
VDC
3.3
4.0
4.5
5
AMPS
5
WATTS
16
19
22
25
25
25
25
25
25
25
27
27
27
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
UL, cUL, TUV Certified CE marked for European Compliance CEC /
DOE EISA 2007 Compliant
5
Standard Specifications
5
• Universal Input Voltage: 90-264Vac 47-63Hz class I or II
• 75 to 85% efficiency
• Output Voltage Tolerance: +/-2.5% Typical, +/-5% Max, from
Full Load to No Load.
• Operating Temperature: 0 - 40°C
• Maximum Output Ripple:
5
5.5
6
4.5
4.15
3.8
3.5
3.3
3.1
3
6.5
7
• 3.3 - 6V: 50mVp-p
• 6.1 - 22V: 100mVp-p
• 22.1 - 32V: 150mVp-p
• 32.1 - 48V: 250mVp-p
7.5
8
9
• Designed for Continuous Duty
10
11
12
13
14
15
16
18
20
22
24
26
28
30
32
36
40
44
48
2.7
2.5
2.5
2.3
2.15
2
• Hold-Up Time : 25mS Minimum @ 120 Vin
• Short Circuit and Over Load Protection
• SELV Output
• MTBF Calculated > 100,000 Hours @ 40°C
• 2 Hour Minimum Loaded Burn-in at 40°C Ambient for
standard output cord configurations
• Leakage current compliant to IEC60601-1 Category B and BF
• 5 Year Warranty
1.85
1.65
1.5
1.35
1.25
1.15
1.07
1
Available Features
• Expanded Operating Temperatures
• 400 Hz Input Rating
• DC Input Rating
• Additional Noise and/or Surge Protection
• LED Power On Indicator
• Fixed-in-place Input Cord
• Wall Plug-in configuration
• Extended Hold-Up Time
0.94
0.83
0.75
0.68
0.63
• Output Cord Sets and Connector Configurations
• Case Colors, Markings & Logos
• 16 Hour Burn-in
All specifications are typical at nominal input, full load, and 25°C unless
otherwise noted
*Add a suffix, “M” for Medical or leave it blank for non-medical.
© Copyright 2015, Astrodyne, Inc
This document is believed to be correct at time of publication and Astrodyne, Inc
accepts no responsibility for consequences from printing errors or inaccuracies.
Specifications are subject to change without notice
www.AstrodyneTDI.com
PH: 908-353-5700 | FAX: 908-353-1021
WSA 500 SERIES, 30 WATTS
HIGH EFFICIENCY, COMPACT DESIGN SWITCHMODE TECHNOLOGY
3.25
A CASE ENCLOSURE
2.72
2.72
1.89
ALSO AVAILABLE WITH INTERNATIONAL
PLUG-IN CONFIGURATION
1.89
3.25
A. WALL PLUG-IN OPTION
B. INPUT CORD OPTION
2.72
VARIOUS INPUT AND OUTPUT CORD
OPTIONS AVAILABLE
1.89
3.25
C. IEC 320 OPTION
Regulatory Compliance
IEC 320 OPTION
USED FOR MOST
INTERNATIONAL APPLICATIONS
Designed for use with medical, information technology, and gen-
eral purpose equipment to the following standards: All models are
approved to:
3.25
• UL 60601-1 / 60950-1
• CSA 22.2 601-1 / 60950-1
• TUV EN 60601-1 / 60950-1
• CE LVD directive
• *cUL Mark
EMC: All models meet European EMC directive and FCC requirements.
Meets all EMC requirements from EN60601-1-2.
Emissions: Level B requirements of FCC CFR 47 part 15 and CISPR11
(EN55011) and CISPR22 (EN55022), EN61000-6-3 (light industrial)
and line harmonic emissions EN61000-3-2.
Immunity: CISPR24 (EN55024), EN61326 and EN61000-3-2.
Certification records are available upon project request.
TOP SURFACE MARKING
AREA = 2.63 X 1.75
© Copyright 2015, Astrodyne, Inc
This document is believed to be correct at time of publication and Astrodyne, Inc
accepts no responsibility for consequences from printing errors or inaccuracies.
Specifications are subject to change without notice
www.AstrodyneTDI.com
PH: 908-353-5700 | FAX: 908-353-1021
相关型号:
WSA524
HIGH EFFICIENCY, COMPACT DESIGN SWITCHMODE TECHNOLOGYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ASTRODYNE
WSA526
HIGH EFFICIENCY, COMPACT DESIGN SWITCHMODE TECHNOLOGYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ASTRODYNE
WSA528
HIGH EFFICIENCY, COMPACT DESIGN SWITCHMODE TECHNOLOGYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ASTRODYNE
WSA530
HIGH EFFICIENCY, COMPACT DESIGN SWITCHMODE TECHNOLOGYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ASTRODYNE
WSA532
HIGH EFFICIENCY, COMPACT DESIGN SWITCHMODE TECHNOLOGYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ASTRODYNE
WSA533
HIGH EFFICIENCY, COMPACT DESIGN SWITCHMODE TECHNOLOGYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ASTRODYNE
WSA536
HIGH EFFICIENCY, COMPACT DESIGN SWITCHMODE TECHNOLOGYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ASTRODYNE
WSA540
HIGH EFFICIENCY, COMPACT DESIGN SWITCHMODE TECHNOLOGYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ASTRODYNE
WSA544
HIGH EFFICIENCY, COMPACT DESIGN SWITCHMODE TECHNOLOGYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ASTRODYNE
WSA545
HIGH EFFICIENCY, COMPACT DESIGN SWITCHMODE TECHNOLOGYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ASTRODYNE
WSA548
HIGH EFFICIENCY, COMPACT DESIGN SWITCHMODE TECHNOLOGYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ASTRODYNE
WSA550
HIGH EFFICIENCY, COMPACT DESIGN SWITCHMODE TECHNOLOGYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ASTRODYNE
©2020 ICPDF网 联系我们和版权申明