ZCS1-120A4DC24VC311 [AZETTLER]
WATER RESISTANT SOLENOID; 水抗电磁阀型号: | ZCS1-120A4DC24VC311 |
厂家: | AMERICAN ZETTLER, INC. |
描述: | WATER RESISTANT SOLENOID |
文件: | 总2页 (文件大小:137K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
ZCS1-120
WATER RESISTANT SOLENOID
FEATURES
• Water resistant
• Capable of handling low and high current requirements
• Versatile mounting and termination
ORDERING INFORMATION
ZCS1-120
1
A
2
1
3
DC6V C 1 1 1
5 6 7 8
4
COIL PARAMETERS
1. Part number: ZCS1-120
• Termination; #8 -32 UNC 2A, #10-32 UNF-2A thread or 1/4” quick
connect
• Connections:
1. Coil isolated (two terminals)
2. One coil lead grounded to bracket (one terminal)
• Coil data:
2. Contact arrangement: A: 1A (SPNO)
3. Coil termination (15in - lb torque spec.)
1. Isolated w/#10-32 terminal (0.22 min. length)
2: Grounded w/#10-32 terminal (0.22 min. length)
3: Isolated w/1/4” Q.C terminal
4: Grounded w/1/4” Q.C terminal
6: Grounded w/#8-32 tapered terminal
7: iSOLATED w/#10-32 terminal (0.45 min. length)
8: Grounded w/#10-32 terminal (0.45 min. length)
4. Coil Voltage: 6,12,14,15, 24, 36, 48
5. Coil Type:
Coil
Voltage (VDC)
Coil
Must-Operate
Voltage (VDC)
Coil
Power (W)
Resistance (ohm)
Rated
6
Max
6.6
Int.
*
Cont.
4.0
Int.
*
Cont.
4.5
Int.
Cont.
12
14
15
24
36
48
13.2
15.4
16.5
26.4
39.6
52.8
6.0
*
9.4
24.0
54.0
*
16.0
26.0
23.0
64.0
160.0
256.0
8.04
*
10.05
16.08
24.12
*
9.0
C: Continuous
I: Intermittent
10.5
11.3
18.0
27.0
26.0
24.0
9.0
6. Contact Material and termination (55 in-lb torque spec.):
1: AgCdO with 5/16” -24 terminal (0.38” min. length)
3: Cu with 5/16” -24 terminal (0.38” min. length)
4: Cu with 1/4” -20 terminal (0.50” min length
5: AgCdO with 5/16” -24 terminal (0.50” min. length)
7. Mounting Bracket: 1: Standard
*Special coils available upon request
2: “L” shaped bracket
8. Factory Assigned Special's: (where undefined contact factory)
1: Without hardware
2: Extra hardware loosely mounted to solenoid
5: Zinc plated mounting bracket
7: No hardware, zinc plated mounting bracket
CONTACT DATA
• Contact Arrangement: 1A (SPNO)
• Contact Material: AgCd0, or Copper
• Termination; 5/16” -24 UNF-2A thread or 1/4” -20 UNC-2A thread
Ratings
Load Voltage
(VDC)
Cont. (A) In-rush (A) Elec. Life Contact Material
12
80
400
400
400
10000*
50,000*
25,000*
Copper
AgCdO
AgCdO
12
36
100
100
*Number of operations
10/11/06
ZCS1-120
GENERAL DATA
Dielelectric Strength
500 Volts
-20°F~150°F (-28.9°C~65.6°C) - Intermittent
-20°F~120°F (-28.9°C~48.9°C) - Continuous
250,000 cycles
Temperature Range
Mechanical Life (no load)
Mounting position (Recommended)
Plunger vertical with cap down
Continuous; Intermittent: 10sec "on"
maximum and minimum 60sec "off".
60sec "on" max and minimum 6min "off."
Duty Cycle
44-55 in*lbs (Contact terminal);
12-18 in*lbs (Coil terminal)
Hardward Torque specification
Weight
170.5 grams
MECHANICAL DATA
1.375
3.253
2 - 0.281X0.400
5“
16
2.UNF- 2A
4
2.125
THREAD TYP
2.875
Cap / Plunger
#10 - 32 UNF -2A
THREAD TYPE
Dimensions and Mounting
Wiring diagram
for Standard Bracket
APPLICATION NOTES:
1.) Not all number combinations are available. Please contact your Sales Representative for available
part numbers.
2.) Solenoid applied in battery charging circuits should be protected from higher than rated voltage during charging.
The service life may be affected by this condition and the solenoid may or may not operate the circuit as intended.
3.) Circuits should be designed to provide safe operation should the solenoid fail in either the open or closed position.
4.) A back-up wrench must be used to hold the bottom nut stationary during installation.
10/11/06
相关型号:
©2020 ICPDF网 联系我们和版权申明