BML-S2C0-Q53G-M624-K0 [BALLUFF]
Magnetically Coded Sensors;型号: | BML-S2C0-Q53G-M624-K0 |
厂家: | Balluff |
描述: | Magnetically Coded Sensors |
文件: | 总2页 (文件大小:126K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Magnetically Coded Sensors
BML-S2C0-Q53L-M604-S0-KA05
Order Code: BML08N2
1) not included in scope of delivery, 2) Distance to tape, 3) Tape, 4) Cable length, 5) Active measurement surface, 6) LED
error signal
Basic features
Electrical data
Additional features 02
Additional features 03
Application
with error signal
Current consumption max. at 24 V DC 80 mA
Real-time capable
linear/rotary motion
Operating voltage Ub
Overvoltage protection
Switch-on delay max.
10...30 VDC
no
Approval/Conformity
cURus
CE
500 ms
EAC
WEEE
Measuring principle
Series
incremental measuring system
S2C
Display/Operation
Function indicator
Green LED
LED red
Electrical connection
Bending radius min., fixed cable
Bending radius min., flexible cable
Cable diameter D
7.5 x D
15 x D
4.9...5.2 mm
Cable length L
5 m, Drag chain compatible
Conductor cross-section
Connection
0.08 mm²
Cable, 5 m, PUR
Connection type
Cable, 5 m, PUR
Connection version
axial
12
Number of conductors
Polarity reversal protected
yes
Internet
www.balluff.com
eCl@ss 9.1: 27-27-07-05
ETIM 6.0: EC002544
1 / 2
Subject to change without notice: 279044
BML08N2_0.36_2021-08-25
Magnetically Coded Sensors
BML-S2C0-Q53L-M604-S0-KA05
Order Code: BML08N2
Environmental conditions
Material
Altitude max.
2000 m
Cable flame-resistant
Housing material
Material jacket
UL94 V0 and IEC 60332/2
Ambient temperature
-20...80 °C
PBT
PUR
Cable temperature, drag chain
Cable temperature, fixed routing
Cable temperature, flexible routing
EN 55016-2-3, Radiation
EN 60068-2-27, Continuous shock
EN 60068-2-27, Shock
EN 60068-2-6, Vibration
EN 61000-4-2, ESD
-25...85 °C
-40...85 °C
-40...85 °C
Mechanical data
Industrial areas
100 g, 2 ms
Dimension
10 x 25 x 35 mm
±4 mm
Lateral offset (Y)
Mounting part
Pitch max.
100 g, 6 ms
Through-hole 3.5 mm
±1.0 °
12 g, 10…2000 Hz
Severity Level 3
Severity Level 2
Severity Level 3
Severity Level 2
Pole width
10 mm
EN 61000-4-3, RFI
Procedure direction
Roll max.
Lengthwise to tape
±3.0 °
EN 61000-4-4, Burst
EN 61000-4-5, Surge
Weight
11 g (excluding cable)
3.0 °
EN 61000-4-6, High-frequency fields Severity Level 3
Yaw max. ±
EN 61000-4-8 Magnetic fields
Severity Level 4
1 mT (no effect)
Ext. magnetic fields max., in
operation
Range/Distance
IP rating
IP67
Edge separation min.
Interpolation factor
Non-linearity max.
Non-linearity typ.
1 ms
Overall system temperature
coefficient
10.5 ppm/K
100
±400 µm (z=1…5 mm, y=±2 mm)
Relative humidity
≤ 90 %, non-condensing
±550 µm (z=0.01…6.5mm,
Storage temperature
-30...85 °C
y=±4mm)
Read distance
Repeat accuracy
Resolution
0.01...6.5 mm
≤ 100 µm
Functional safety
100 µm (edge separation A/B)
0.8 m/s
MTTF (40 °C)
692 a
Traverse speed max.
Interface
Differential signals
Error signal
no
yes
Interface
Digital A/B (HTL)
without reference signal
A before B = rising
Reference signal
Signal sequence
Wiring Diagrams
Internet
www.balluff.com
eCl@ss 9.1: 27-27-07-05
2 / 2
Subject to change without notice: 279044
ETIM 6.0: EC002544
BML08N2_0.36_2021-08-25