BSP00T8 [BALLUFF]
Pressure Sensors;型号: | BSP00T8 |
厂家: | Balluff |
描述: | Pressure Sensors |
文件: | 总2页 (文件大小:129K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Pressure Sensors
BSP B010-FV004-D06S1A-S4
Order Code: BSP00T9
Basic features
Environmental conditions
Approval/Conformity
CE
Ambient temperature
Compensation temperature
EN 60068-2-27, Shock
EN 60068-2-6, Vibration
IP rating
-25...85 °C
UKCA
cULus
EAC
-25...85 °C
500 g, 1 ms
10 g, 25…2000 Hz
IP67
WEEE
Interference immunity
Media temperature
EN 61326-2-3: 2013
-40...125 °C
Electrical connection
Noise emission
EN 61326-2-3: 2013
-40...85 °C
Connection
M12x1-Male, 4-pin, A-coded
Storage temperature
Temperature coefficient typ.
Polarity reversal protected
Short-circuit protection
yes
yes
≤ ±0.5 % FSO/10K
Functional safety
Electrical data
MTTF (40 °C)
661 a
Current draw max.
Load cycles
30 mA
100 mil.
18...30 VDC
250 mA
III
Operating voltage Ub
Output current max.
Protection class
Interface
Interface
IO-Link 1.1
Switching output
PNP normally open/normally
closed (NO/NC)
Switching cycles min.
Switching frequency
100 mil.
200 Hz
Material
Connector housing, material
Gasket, material
Nickel-plated brass
FKM
Housing material
1.4301 stainless steel
Ceramic Al2O3
1.4301 stainless steel
Measuring cell, material
Process connection material
Internet
www.balluff.com
eCl@ss 9.1: 27-20-13-02
1 / 2
Subject to change without notice: 246540
ETIM 6.0: EC000243
BSP00T9_0.51_2021-08-31
Pressure Sensors
BSP B010-FV004-D06S1A-S4
Order Code: BSP00T9
Mechanical data
Range/Distance
Process connection
Tightening torque max.
Weight
NPT 1/4"
30 Nm
120 g
Accuracy
±0.5 % FSO BFSL
35 bar
Burst pressure
Long-term stability max.
Measuring range
Overload pressure
Resolution
0.3 % FSO/year
0...10 bar
20 bar
≤ 12 bits
Response time max.
Sampling rate
13 ms
1 ms
Remarks
vacuum-tight
For more information about MTTF and B10d see MTTF / B10d Certificate
Indication of the MTTF- / B10d value does not represent a binding composition and/or life expectancy assurance; these are simply experiential values with
no warranty implications. These declared values also do not extend the expiration period for defect claims or affect it in any way.
Connector Drawings
Wiring Diagrams
1) Standard mode
2) IO-Link mode
Internet
www.balluff.com
eCl@ss 9.1: 27-20-13-02
ETIM 6.0: EC000243
2 / 2
Subject to change without notice: 246540
BSP00T9_0.51_2021-08-31
©2020 ICPDF网 联系我们和版权申明