LG10A65NU [BANNER]
Laser Gauging Sensors;型号: | LG10A65NU |
厂家: | Banner Engineering |
描述: | Laser Gauging Sensors |
文件: | 总11页 (文件大小:982K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
®
L-GAGE LG Laser Gauging Sensors
Datasheet
•
•
•
•
Self-contained Class 2 modulated visible laser gauging sensor needs no separate
controller
Narrow eꢀecꢁve beam is excellent for precision gauging applicaꢁons such as
distance, height, or thickness measurement
Resoluꢁon to beꢂer than 3 microns for LG5 Series models and beꢂer than 10
microns for LG10 Series models
Banner’s unique scalable analog output automaꢁcally distributes the output signal
over the width of the programmed sensing window 1
•
•
Analog and discrete (switched) outputs with independent window limits
Analog output slope is either posiꢁve or negaꢁve, depending upon which window
limit is programmed first
•
Fast, easy-to-use integrated push-buꢂon TEACH-mode programming; no
potenꢁometer adjustments – Remote TEACH funcꢁon for security and
convenience
•
•
Unique feature holds analog output value for 2 seconds upon loss of signal
Modulated laser beam and narrow opꢁcal band-pass filter provide a high level of
ambient light immunity, including immunity from high-energy factory lighꢁng
•
•
•
Alarm output for signal saturaꢁon and overload of discrete output
Output response is programmable for three speeds
Supply voltage: 12 to 30 V dc
WARNING: Not To Be Used for Personnel Protecꢀon
Never use this device as a sensing device for personnel protecꢀon. Doing so could lead to serious injury or death.
This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety
applicaꢁons. A sensor failure or malfuncꢁon can cause either an energized or de-energized sensor output
condiꢁon.
Models
Analog Current Output Analog Voltage Output
2
3
Sensing Distance
Focal Point
Cable
Discrete Output
Models (4–20 mA)
Models (0–10 V dc)
LG5A65PI
LG5A65PU
2 m (6.5 ꢃ) (8-wire)
Pigtail QD (8-pin Euro)
2 m (6.5 ꢃ) (8-wire)
Pigtail QD (8-pin Euro)
2 m (6.5 ꢃ) (8-wire)
Pigtail QD (8-pin Euro)
2 m (6.5 ꢃ) (8-wire)
Pigtail QD (8-pin Euro)
2 m (6.5 ꢃ) (8-wire)
Pigtail QD (8-pin Euro)
2 m (6.5 ꢃ) (8-wire)
Pigtail QD (8-pin Euro)
PNP (Sourcing)
70 mm (2.8 inches)
LG5A65PIQ
LG5A65NI
LG5A65PUQ
LG5A65NU
Beam size at 53 mm: 0.4 x 0.6 mm
(0.016 x 0.024 inches)
NPN (Sinking)
PNP (Sourcing)
NPN (Sinking)
PNP (Sourcing)
NPN (Sinking)
LG5A65NIQ
LG5B65PI
LG5A65NUQ
LG5B65PU
45 to 60 mm (1.8 to
2.4 inches)
53 mm (2.1 inches)
LG5B65PIQ
LG5B65NI
LG5B65PUQ
LG5B65NU
Beam size at 53 mm: 0.1 mm (0.004
inches)
LG5B65NIQ
LG10A65PI
LG10A65PIQ
LG10A65NI
LG10A65NIQ
LG5B65NUQ
LG10A65PU
LG10A65PUQ
LG10A65NU
LG10A65NUQ
180 mm (7.1 inches)
75 to 125 mm (2.9 to
4.9 inches)
Beam size at 125 mm: 0.6 x 0.8 mm
(0.024 x 0.031 inches)
1
2
3
Patent(s) issued or pending.
The focal point is the distance, measured from the sensor lens, at which the laser image is smallest.
To order the 9 m (30 ꢃ) cable model, add suffix "W/30" to the cabled model number (LG5A65PI W/30).
Original Document
59786 Rev. G
23 May 2017
59786
®
L-GAGE LG Laser Gauging Sensors
Overview
Banner’s Class 2 visible laser displacement sensor brings a sophisꢁcated yet cost-eꢀecꢁve soluꢁon to precision measurement
applicaꢁons. L-GAGE Series sensors feature all-in-one design and require no separate controller.
The L-Gage Laser Gauging System operates in two modes: TEACH (or programming) and RUN. Near and far sensing window limits are set
quickly using simple push-buꢂon or remote signal TEACH-mode programming. One sensor can simultaneously provide both analog and
discrete (switched) outputs. Sensing window limits for each output may be independently programmed. The analog signal features
Banner’s unique scalable output (patent pending), which automaꢁcally distributes the output signal over the width of the programmed
sensing window.
The L-GAGE Laser Gauging Sensor boasts many addiꢁonal features, including selectable response speed, self-diagnosꢁcs with alarm
output, comprehensive status indicator system, and unique output “hold” funcꢁon in case of momentary signal loss in profiling
applicaꢁons.
Opꢀcal Triangulaꢀon
PSD Receiver
Element
The design of the L-GAGE Laser Gauging Sensor is based on opꢁcal triangulaꢁon. An
emiꢂer transmits visible laser light through a lens, toward a target. The laser light
beam from the emiꢂer bounces oꢀ the target, scaꢂering some of its light through
another lens to the sensor’s PSD (posiꢁon-sensiꢁve device) receiver element. The
Signal
Conditioning
Circuitry
target’s distance from the receiver determines the angle the light travels to the
Near
Limit
Far
Limit
Lenses
receiver element; this angle in turn determines where the received light will fall
along the PSD receiver element.
Target Movement
Microprocessor
The posiꢁon of the light on the PSD receiver element is processed through analog
and digital electronics and analyzed by the microprocessor, which calculates the
appropriate output value. The analog output provides a variable signal that is
proporꢁonal to the target’s posiꢁon within the user-programmed analog window
limits. The discrete (switched) output energizes whenever the target is located
between the user-programmed discrete window limits. Analog and discrete window
limits may be the same, or programmed independently.
Output
Circuitry
Emitter
Circuitry
E
Laser
Emitter
Programmed
Sensing Window
Indicators
Signal LED. The Signal LED indicates the strength and condiꢁon of the sensor’s incoming signal.
Signal LED Status
Indicates
OFF
No signal is received, or the target is beyond the range limitaꢁons of the sensor (with some
tolerance beyond the recommended minimum and maximum sensing distance)
Flashing at 2 Hz
Flashing at 10 Hz
ON Solid
Received signal is adequate for processing
Received signal is in saturaꢁon (signal is too strong); alarm output energizes
Received signal is within the nominal condiꢁons for the sensor
Output LED. The Output LED lights when the discrete output is conducꢁng.
Power ON/OFF LED. The Power ON/OFF LED indicates the operaꢁng status of the sensor.
Power ON/OFF LED Status
OFF
Indicates
Power is OFF
Flashing at 2 Hz
Flashing at 1 Hz
ON Solid
Discrete or alarm output is overloaded
Power ON, Laser is disabled
Sensor is operaꢁng normally (power is ON, Laser enabled)
Power Up/Laser Enable. When powering up the sensor, the following should occur:
•
•
All LEDs turn ON for 1 second
Allow 1.25 second delay for Laser Enable at power up. (If sensor is already powered up, allow 0.25 second for Laser Enable.)
2
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 59786 Rev. G
®
L-GAGE LG Laser Gauging Sensors
Conꢁguraꢀon Instrucꢀons
Sensor Programming
Program the sensor using either the sensor’s keypad or via remote
programming. Remote programming is also used to disable the
keypad for security, prevenꢁng unauthorized or accidental
programming adjustment on the producꢁon floor.
Response Speed
Push Button
Response Speed
Indicators
Teach LED
Analog Output
Programming Push Button
Discrete (Switched) Output
Programming Push Button
Signal LED
Output LED
Power ON/OFF LED
Remote Programming
For remote programming, connect the sensor’s yellow wire to +5 to 30V dc, with a remote programming switch connected between
them. The impedance of the remote teach input is 18 kΩ minimum (65 kΩ minimum at 5V).
To program the sensor, follow the sequence of input pulses, buꢂon pushes, and “clicks” for programming on the sensor buꢂons. The
duraꢁon of each pulse (corresponding to a push buꢂon “click”), and the period between mulꢁple pulses, are defined as: 0.04 seconds <
T < 0.8 seconds.
Analog Output Slope
The L-GAGE Laser Gauge may be programmed for either a posiꢁve or a negaꢁve output slope, based on which condiꢁon is taught first. If
the near limit is taught first, the slope will be posiꢁve; if the far limit is taught first, the slope will be negaꢁve. Banner’s unique scalable
analog output (patent pending) automaꢁcally distributes the output signal over the width of the programmed sensing window. Factory
analog output is 0 to 10V dc (LG..U models) or 4 to 20 mA (LG..I models).
Voltage Models
Current Models
10
20
Positive
Slope
Positive
Slope
0
4
Near
Window
Far
Window
Near
Window
Far
Window
Target Position
Target Position
Analog output as a funcꢁon of target posiꢁon
The L-GAGE also features a 2-second hold upon loss of the analog signal, which is useful for profiling and similar applicaꢁons. In the
event of analog signal loss for longer than 2 seconds, the analog output goes to 0V dc (LG..U models) or 4 mA (LG..I models).
P/N 59786 Rev. G
www.bannerengineering.com - Tel: +1-763-544-3164
3
®
L-GAGE LG Laser Gauging Sensors
Teaching Analog Limits Using the Auto-Zero Feature (Analog Output)
For some analog applicaꢁons, a sensing distance set point centered within a sensing window may be required. The TEACH procedure is
simple: teaching the same limit twice causes the sensor to program a window centered on the posiꢁon taught. This window is 10 mm
wide (taught posiꢁon ± 5 mm).
Teaching Fixed-Field Sensing Mode (Discrete Output)
Teaching the same limit twice creates a sensing window with the far limit at the teach distance and the near limit at the minimum
operaꢁng range of the sensor (approx. 42 mm for LG5 Series models, and approx. 60 mm for LG10 Series models).
Beam Dimensions (Typical)
Focal Point
Distance
Beam Width (X)
Beam Height (Y)
LG5 Series
45 mm
53 mm
60 mm
45 mm
53 mm
60 mm
0.3 mm
0.1 mm
0.3 mm
0.6 mm
0.4 mm
0.3 mm
0.5 mm
0.1 mm
0.5 mm
0.9 mm
0.6 mm
0.4 mm
53 mm (2.1 inches)
Y
70 mm (2.8 inches)
LG10 Series
X
75 mm
1.1 mm
0.8 mm
1.5 mm
1.1 mm
100 mm
180 mm (7.1 inches)
125 mm
0.6 mm
0.8 mm
The focal point is the distance, measured from the sensor lens, at which the laser image is smallest.
Teaching Limits for Either Analog or Discrete Output
Either output may be programmed first. For the buꢂon or the remote wire, a buꢂon click or pulse is: 0.04 seconds ≤ T ≤ 0.8 seconds.
1. Enter programming mode.
Method
Acꢀon
Result
TEACH LED turns ON:
Red — Analog output
Green — Discrete output
4
Push Buꢂon
Remote Input
Push and hold the buꢂon for Analog or Discrete output for more than 2 seconds
No acꢁon required
Sensor is waiꢁng for first limit
2. Teach the first limit.
Method
Acꢀon
Result
TEACH LED flashes at 2 Hz
Push Buꢂon
Posiꢁon the target for the first limit and click the same buꢂon
Sensor learns first limit and waits for second
limit
TEACH LED turns ON:
Red — Analog output
Green — Discrete output
Posiꢁon the target for the first limit. For the analog output, double-pulse the remote
line. For the discrete output, single-pulse the remote line.
Remote Input
TEACH LED flashes at 2 Hz
Sensor learns first limit and waits for second
limit
4
Sensor returns to Run mode if the first TEACH condiꢁon is not registered within 120 seconds.
4
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 59786 Rev. G
®
L-GAGE LG Laser Gauging Sensors
3. Teach the second limit.
Method
Acꢀon
Result
Push Buꢂon
Posiꢁon the target for the second limit and click the same buꢂon
TEACH LED goes OFF
Sensor learns second limit and returns
automaꢁcally to RUN mode
Remote Input
Posiꢁon the target for the second limit and single-pulse the remote line
4. Repeat for the other output if a second output is desired.
Teaching Limits for Analog and Discrete Outputs Simultaneously
Both analog and discrete outputs will have idenꢁcal limits. For the buꢂon or the remote wire, a buꢂon click or pulse is: 0.04 seconds ≤ T
≤ 0.8 seconds.
1. Enter programming mode.
Method
Acꢀon
Result
5
Push and hold either buꢂon for more than 2 seconds
Briefly click the other buꢂon
TEACH LED turns ON: Yellow
Push Buꢂon
Remote Input
Sensor is waiꢁng for first limit
No acꢁon required
2. Teach the first limit.
Method
Acꢀon
Result
TEACH LED flashes at 2 Hz, alternaꢁng Red and
Green
Push Buꢂon
Posiꢁon the target for the first limit and click either buꢂon
Sensor learns first limit and waits for second
limit
TEACH LED turns ON: Yellow
Sensor learns first limit and waits for second
limit
Remote Input
Posiꢁon the target for the first limit and triple-pulse the remote line
TEACH LED flashes at 2 Hz, alternaꢁng Red and
Green
3. Teach the second limit.
Method
Acꢀon
Result
Push Buꢂon
Posiꢁon the target for the second limit and click either buꢂon
TEACH LED goes OFF
Sensor learns second limit and returns
automaꢁcally to Run mode
Remote Input
Posiꢁon the target for the second limit and single-pulse the remote line
Sensor Conꢁguraꢀon
Response Speed. Use the Speed push buꢂon to toggle between the three response speed seꢄngs. The combinaꢁon of indicator lights
(Fast and Slow) will tell you which of the three is selected:
Slow
ON
Fast
OFF
ON
Analog Output Frequency Response (–3 dB)
Discrete Output Response Speed
100 milliseconds
4.5 Hz
45 Hz
ON
10 milliseconds
OFF
ON
450 Hz
2 milliseconds
Push Buꢂon Lockout. Enables or disables the keypad to prevent accidental or unauthorized adjustment of the programming seꢄngs.
Procedure
Result
Remote Wire (0.04 sec. < T <
0.8 sec.)
Push Buꢂon
Enable/Disable Push Buꢂons
Not available via push buꢂon
Four-pulse the remote line
Push buꢂons are either enabled
or disabled, depending on
previous condiꢁon
5
Sensor returns to Run mode if first TEACH condiꢁon is not registered within 120 seconds.
P/N 59786 Rev. G
www.bannerengineering.com - Tel: +1-763-544-3164
5
®
L-GAGE LG Laser Gauging Sensors
Installaꢀon Notes
Some targets (those with a stepped plane facing the sensor, a boundary line, or rounded targets) pose specific problems for sensing
distances. The following two images illustrate sensor orientaꢁons for typical targets.
Recommended
Not Recommended
WARNING: Class 2 Safety Notes
Low-power lasers are by definiꢁon incapable of causing eye injury within the duraꢁon of the blink, or aversion
response of 0.25 seconds. They must also emit only visible wavelengths (400-700 nm). Therefore, an ocular hazard
can only exist if an individual overcomes their natural aversion to bright light and stares directly into the laser
beam. The device requirements for these lasers are to have a [hazard] label and to have an indicator light to
indicate laser emission.
The two operaꢀonal safety rules are:
•
•
Do not permit a person to stare at the laser from within the beam
Do not point the laser at a person's eye at close range
6
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 59786 Rev. G
®
L-GAGE LG Laser Gauging Sensors
WARNING:
Beam Paths
The beam emiꢂed by a class 2 laser product should be terminated
at the end of its useful path. Open laser beam paths should be
located above or below eye level where pracꢁcal.
CAUTION: Do Not Disassemble for Repair
This device contains no user-serviceable components. Do not
aꢂempt to disassemble for repair. Use of controls or adjustments
or performance of procedures other than those specified herein
may result in hazardous radiaꢁon exposure. A defecꢁve unit must
be returned to the manufacturer.
RADIANT POWER 0.2 mW
9.8KHz 11-20% DUTY CYCLE
640 - 660 nm
Complies to 21CFR, Parts 1040.10 and
1040.11 except for deviations pursuant to
Laser Notice 50, dated 7-26-01.
Wiring Diagrams
Wiring connecꢁons are funcꢁonally idenꢁcal for either integral or QD cable.
NPN Models
PNP Models
Key
1 = White
2 = Brown
3 = Green
4 = Yellow
5 = Gray
2
7
1
2
7
1
+
+
12–30 V dc
–
12–30 V dc
–
4–20 mA
or 0–10 V
4–20 mA
or 0–10 V
+
–
+
–
6 = Pink
Discrete
Load
Discrete
Load
5
6
7 = Blue
8 = Shield
5
6
Alarm
Load
Alarm
Load
4
3
8
Remote
Teach
Laser
+ 5–30 V dc
4
3
8
Remote
Teach
Laser
+ 5–30 V dc
+ 5–30 V dc ON
0 V dc OFF
Control
+ 5–30 V dc ON
0 V dc OFF
Control
Shield*
Shield*
4 to 20 mA (LG..I models) or 0 to 10V dc (LG..U models)
*The bare shield wire is connected internally to the sensor housing and should be connected as follows:
1. If the sensor housing is mounted so that it is in conꢁnuity with both the machine frame and earth ground, connect the bare
wire (also) to earth ground.
2. If the sensor housing is mounted so that it is insulated from the machine frame, connect the bare wire to -V dc (together with
the blue wire).
3. If the sensor is mounted so that it is in conꢁnuity with the machine frame, but not with earth ground, do not connect the bare
wire (i.e. cut oꢀ the bare wire).
Conversion from Current to Voltage Output (LGxI Models Only)
Typical Voltage Response
bn
bu
+
Value of R
250 Ω
Output Voltage
1 to 5 V
12-30V dc
–
**
R
V
500 Ω
2 to 10 V
wh
**For best results, install a small amount of
capacitance (e.g., 0.1 μF) in parallel with the load resistor
P/N 59786 Rev. G
www.bannerengineering.com - Tel: +1-763-544-3164
7
®
L-GAGE LG Laser Gauging Sensors
Speciꢁcaꢀons
Supply Voltage
Output Conꢁguraꢀons
12 to 30 V dc (10% maximum ripple); 50 mA max at 24 V dc (exclusive of load)
Discrete (switched) and alarm outputs: SPST solid-state switch; choose NPN
(current sinking) or PNP (current sourcing) models
Analog current output (LG...I Models): 4 to 20 mA or 20 to 4 mA (current
sourcing)
Supply Protecꢀon Circuitry
Protected against reverse polarity and transient over voltages
Analog voltage output (LG...U Models): 0 to 10 V dc or 10 to 0 V dc (voltage
sourcing)
Sensing Range
LG5: 45 to 60 mm (1.77 to 2.36 inches)
LG10: 75 to 125 mm (2.95 to 4.92 inches)
Output Raꢀngs
Discrete (switched) and Alarm outputs: 100 mA maximum
OFF-state leakage current: less than 5 microamps
Output saturaꢁon voltage - PNP outputs: less than 1.2 volts at 10 mA and less
than 1.6 volts at 100 mA
Delay at Power-up
1.25 seconds
Sensing Beam
Output saturaꢁon voltage - NPN outputs: less than 200 millivolts at 10 mA and
less than 600 millivolts at 100 mA
650 nm visible red IEC and CDRH Class 2 laser; 0.20 mW radiant output power
Adjustments
Analog output (LG...I Models): 1 kΩ max at 24 V dc, max load resistance = [(Vcc
- 4.5)/0.02]Ω
Analog output (LG...U Models): 2.5 kΩ minimum load impedance
Response speed: Push buꢂon toggles between Slow, Medium, and Fast (see
Output Response Time)
Window limits (analog or discrete): TEACH-mode programming of near and far
window limits (see programming procedure). Limits may also be taught
remotely.
Output Protecꢀon
Discrete and alarm outputs are protected against conꢁnuous overload and
short circuit
Analog output slope: The first limit taught is assigned to the minimum analog
output.
Analog Output (–3 dB) Response Time
Construcꢀon
Fast: 450 Hz (1 millisecond average with 1 millisecond update rate)
Medium: 45 Hz (10 millisecond average with 2 millisecond update rate)
Slow: 4.5 Hz (100 millisecond average with 5 millisecond update rate)
Housing: Zinc alloy die-cast, plated and painted finish
Cover plate: aluminum with painted finish
Lens: acrylic
Discrete Output Response Time
Fast: 2.0 milliseconds ON and OFF
Medium: 10 milliseconds ON and OFF
Slow: 100 milliseconds ON and OFF
Connecꢀons
2 m (6.5 ꢃ) or 9 m (30 ꢃ) 7-conductor shielded PVC-jacketed aꢂached cable, or
150 mm (6 in) 8-pin Euro-style pigtail quick-disconnect. Maꢁng QD cables are
purchased separately.
6
6
Analog Resoluꢀon and Repeatability of Discrete Trip Point (LG5)
Analog Resoluꢀon and Repeatability of Discrete Trip Point (LG10)
Fast: < 40 microns @ 50 mm
Medium: < 12 microns @ 50 mm
Slow: < 3 microns @ 50 mm
Fast: < 150 microns @ 100 mm
Medium: < 50 microns @ 100 mm
Slow: < 10 microns @ 100 mm
6
6
Analog Linearity (LG5)
Analog Linearity (LG10)
±60 microns (±0.002") over 45 to 60 mm sensing window
±10 microns (±0.0003") over 49 to 51 mm sensing window
±200 microns (±0.008 inches) over 75 to 125 mm sensing window
±20 microns (±0.0008 inches) over 95 to 100 mm sensing window
Minimum Window Size (Analog or Discrete)
LG5: 1.5 mm (0.06 inches)
Hysteresis (Discrete Output)
LG5: < 0.2 mm (0.008 inches)
LG10: < 1.0 mm (0.04 inches)
LG10: 5 mm (0.2 inches)
Color Sensiꢀvity (typical)
Temperature Driꢃ
LG5: ±7 microns/°C
LG10: ±25 microns/°C
LG5: < 75 microns (0.003 inches) for white to dark gray ceramic target
LG10: < 100 microns (0.004 inches) for white to dark gray ceramic target
Remote TEACH and Laser Control Input Impedance
Laser Control
18 kΩ minimum (65 kΩ at 5V dc)
To enable laser: Connect green wire to +5 to 30 V dc
To disable laser: Connect green wire to 0 to +2 V dc (or open connecꢁon)
250 millisecond delay upon enable/disable
Remote TEACH
To teach: Connect yellow wire to +5 to 30 V dc
To disable: Connect yellow wire to 0 to +2 V dc (or open connecꢁon)
6
Resoluꢁon and linearity specified @ 24 V dc, 22 °C, using a white ceramic test surface (see Applicaꢁon Notes)
8
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 59786 Rev. G
®
L-GAGE LG Laser Gauging Sensors
Applicaꢀon Notes
Required Overcurrent Protecꢀon
For comparison, a white ceramic test surface has approximately 91% of the
reflecꢁvity of a white Kodak test card with a maꢂe finish. A dark gray ceramic
test surface has approximately 11% of the reflecꢁvity of a white Kodak test
card with a maꢂe finish. (Allow 15-minute warm-up for maximum linearity.)
WARNING: Electrical connecꢁons must be made
by qualified personnel in accordance with local
and naꢁonal electrical codes and regulaꢁons.
Operaꢀng Condiꢀons
Overcurrent protecꢁon is required to be provided by end product applicaꢁon
per the supplied table.
Temperature: –10 °C to 50 °C (14 °F to 122 °F)
Maximum relaꢁve humidity: 90% at +50 °C, non-condensing
Overcurrent protecꢁon may be provided with external fusing or via Current
Limiꢁng, Class 2 Power Supply.
Environmental raꢀng
Supply wiring leads < 24 AWG shall not be spliced.
For addiꢁonal product support, go to www.bannerengineering.com.
IP67, NEMA 6
Vibraꢀon and Mechanical Shock
Supply Wiring (AWG)
Required Overcurrent Protecꢀon (Amps)
Vibraꢁon: 60 Hz, 30 minutes, 3 axes
Shock: 30G for 11 milliseconds, half sine wave, 3 axes
20
22
24
26
28
30
5.0
3.0
2.0
1.0
0.8
0.5
Cerꢀꢁcaꢀons
Resoluꢀon
The following charts illustrate the L-GAGE resoluꢁon with respect to speed (typical, using a white ceramic target).
LG5 Models
LG10 Models
LG10 Models
LG Models
225
200
175
150
125
100
75
45
40
35
30
25
20
15
10
5
Fast
Fast
Medium
Slow
50
25
0
Medium
Slow
75
95
105
115
125
135
Distance (mm)
0
45
50
55
60
65
Distance (mm)
P/N 59786 Rev. G
www.bannerengineering.com - Tel: +1-763-544-3164
9
®
L-GAGE LG Laser Gauging Sensors
Dimensions
20.2 mm (0.80")
55.3 mm
(2.18")
45.5 mm
(1.79")
4.6 mm
(0.18")
Emitted Light
23.9 mm
(0.94")
RADIANT
9.8KHz
1
POWER
Complies to 21CFR, Parts 1040.10 and
1-20% DUTY CYCLE
1040.1
0.2
- 660 nm
640
mW
1
except for deviations
Laser
Notice 50, dated 7-26-01.
pursuant to
Received Light
19.1 mm
(0.75")
68.3 mm
(2.69")
82.3 mm
(3.24")
Clearance for M4 (#8)
Screws (2 places)
9.3 mm
(0.37")
Mounꢁng hardware (M4) is included.
Accessories
Cordsets
8-Pin Threaded M12/Euro-Style Cordsets with Shield
Model
Length
Style
Dimensions
Pinout (Female)
2
3
4
1
7
6
44 Typ.
MQDC-806
1.83 m (6 ꢃ)
5
8
Straight
M12 x 1
ø 14.5
MQDC-815
MQDC-830
4.57 m (15 ꢃ)
9.14 m (30 ꢃ)
1 = White
2 = Brown
3 = Green
4 = Yellow
5 = Gray
6 = Pink
7 = Blue
8 = Shield
Brackets
SMBLG
SMBLGA
•
L-GAGE sensor mounꢁng
bracket
•
L-GAGE adjustable bracket
assembly
•
304 Stainless Steel
•
304 Stainless Steel
10
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 59786 Rev. G
®
L-GAGE LG Laser Gauging Sensors
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or
replace, free of charge, any product of its manufacture which, at the ꢁme it is returned to the factory, is found to have been defecꢁve during the warranty period. This warranty does not cover
damage or liability for misuse, abuse, or the improper applicaꢁon or installaꢁon of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discreꢁon of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY
OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT
DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligaꢁons or liabiliꢁes relaꢁng to any product previously
manufactured by Banner Engineering Corp. Any misuse, abuse, or improper applicaꢁon or installaꢁon of this product or use of the product for personal protecꢁon applicaꢁons when the
product is idenꢁfied as not intended for such purposes will void the product warranty. Any modificaꢁons to this product without prior express approval by Banner Engineering Corp will void the
product warranꢁes. All specificaꢁons published in this document are subject to change; Banner reserves the right to modify product specificaꢁons or update documentaꢁon at any ꢁme.
Specificaꢁons and product informaꢁon in English supersede that which is provided in any other language. For the most recent version of any documentaꢁon, refer to:
www.bannerengineering.com.
©
Banner Engineering Corp. All rights reserved
相关型号:
LG10M12K0BP342525
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 10V, 20% +Tol, 20% -Tol, 12000uF, Through Hole Mount, ROHS COMPLIANT
YAGEO
LG10M15K0BPF-2235
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 10V, 20% +Tol, 20% -Tol, 15000uF, Through Hole Mount, ROHS COMPLIANT
YAGEO
LG10M22K0BP343025
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 10V, 20% +Tol, 20% -Tol, 22000uF, Through Hole Mount, ROHS COMPLIANT
YAGEO
LG10M27K0BP342250
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 10V, 20% +Tol, 20% -Tol, 27000uF, Through Hole Mount, ROHS COMPLIANT
YAGEO
LG10M33K0BP342545
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 10V, 20% +Tol, 20% -Tol, 33000uF, Through Hole Mount, ROHS COMPLIANT
YAGEO
LG10M33K0BP4-2545
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 10V, 20% +Tol, 20% -Tol, 33000uF, Through Hole Mount, ROHS COMPLIANT
YAGEO
LG10M33K0BP442545
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 10V, 20% +Tol, 20% -Tol, 33000uF, Through Hole Mount, ROHS COMPLIANT
YAGEO
©2020 ICPDF网 联系我们和版权申明