LMBWLB72RAS [BANNER]
WLB72B Industrial LED Light Bar (AC);型号: | LMBWLB72RAS |
厂家: | Banner Engineering |
描述: | WLB72B Industrial LED Light Bar (AC) |
文件: | 总6页 (文件大小:634K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
WLB72B Industrial LED Light Bar (AC)
Datasheet
Banner's WLB72 is a very bright LED luminaire that features an even light output for a no glare 'glow'. The WLB72 series is
designed for a wide variety of environments and applications, including but not limited to work stations, machine lighting, and low
bay lighting. The WLB72 uses advanced LED lighting technology to provide a high-quality and maintenance free industrial lighting
solution.
•
•
•
•
•
•
Increase worker productivity and ergonomics with bright, high-quality, uniform light
Exceptionally energy efficient for overall cost savings
Durable light with a metal housing and shatter-resistant window
Intensity can be controlled from 5% to 100% using a compatible dimmer
Rated for use at 120 V ac to 277 V ac
Fast installation with multiple integrated mounting options or accessory brackets
The WLB72 Industrial LED Light Bars are continuous run models that come with 1/2-inch conduit knockouts on the side, back, and
both end caps that allow for lights to be cascaded or "daisy-chained" for a continuous length of light. WLB72 models come with a
five year, limited warranty. To view or download the latest technical information about this product, including specifications,
dimensions, accessories, and wiring, see www.bannerengineering.com.
Important: Lea el siguiente instructivo antes de operar el luminario. Por favor descargue desde
www.bannerengineering.com toda la documentación técnica de los WLB72B Industrial LED Light Bar,
disponibles en múltiples idiomas, para detalles del uso adecuado, aplicaciones, advertencias, y las
instrucciones de instalación de estos dispositivos.
Important: Lisez les instructions suivantes avant d'utiliser le luminaire. Veuillez télécharger la documentation
technique complète des WLB72B Industrial LED Light Bar sur notre site www.bannerengineering.com pour les
détails sur leur utilisation correcte, les applications, les notes de sécurité et les instructions de montage.
Models
Lighted
Family
Tier
Voltage Cascadable
Length (mm)
Control
Connector
LED Color
Window
WLB72
B
Z
C
W
1200
D
A
CT
1200
C = Cascadable
A = 0-10 V Analog
Dimming
B = Basic
Z = AC
W = Daylight white
D = Diffused window
CT = Conduit Entry
Original Document
210184 Rev. A
22 August 2019
210184
WLB72B Industrial LED Light Bar (AC)
Installation Instructions
Install the Light
To remove cover, press
inward at points shown
on both sides.
4x
Self-tapping screw holes (4x)
Figure 1. Removing the cover
WARNING:
•
•
•
•
Risk of Electric Shock
Failure to follow these instructions could result in serious injury or death.
Installation and service of luminaries should be performed by a qualified licensed electrician.
Disconnect or turn off power before installing, removing, or servicing luminaire. Luminaire must be
installed and connected in accordance with the National Electrical Code (NEC) and any applicable local
code requirements. Luminaire must be supplied with a 120–277 V ac 50/60 Hz fuse box or circuit
breaker.
To mount the WLB72 Industrial LED Light Bar, follow these steps.
1. Remove luminaire from packaging and inspect for damage before installing.
2. Determine the mounting method and location. The WLB72 is rated for wall, ceiling, or under cabinet mounting. Optional
mounting brackets are available, see Accessories (p. 5).
3. Remove the cover from the housing by pressing inward at the two snap features on the housing.
4. Place the light in the mounting location and mark the positions of the light mounting holes.
5. Drill the holes and use the appropriate screws to secure the luminaire to the mounting location.
Wire the Light
Follow these steps to wire your WLB72 Industrial LED Light Bar.
Three-position connector
Two-position connector
• First position to LED Driver
• Middle position supply
• Last position for cascade to
another light
white black
(N) (L)
ground
Cable to LED board
(board not shown)
Black and red wires are DC
output power to LED board.
Installer must make connection
using two-position connector, as
shown.
INPUT
OUTPUT
LED Driver
Two dimming wires
(purple and gray)
1. Remove the cover from the housing by pressing inward at the two snap locations on the housing.
2
www.bannerengineering.com - Tel: + 1 888 373 6767
P/N 210184 Rev. A
WLB72B Industrial LED Light Bar (AC)
2. Connect the power by removing the selected knockout and installing either 1/2-inch conduit or an AC power cord with
supplied cord grip strain relief. If you are using rigid conduit, the conduit hub/connector must be approved for use in dry or
damp locations and must be connected to the conduit before the hub/connector is connected to the luminaire. The
supplied cord grip diameter range is 4.3 to 11.4 mm.
3. Connect the incoming supply wires to the LED Driver input connectors according to the wiring diagram.
4. Connect the ground wire to the three-position ground connector.
5. If you are using 0–10 V analog dimming, connect to the LED Driver dimming connectors according to the wiring diagram.
6. Attach the red and black wires from the cover LED board to the output connectors on the Driver.
7. Re-attach the cover to the housing by snapping it into place. Secure the cover to the housing by using a minimum of one
self tapping screw on each end of the housing (four screws are provided).
8. Repeat these steps on other end of the luminaire if you are connecting to more than one luminaire in a continuous run.
Wiring Diagram
Diagram
Wire
Connection
L - Black
N - White
Line/Hot
Neutral
L
L
N
N
Earth ground
- Green/Yellow
Dim (+) - Purple
0–10 V dc analog dimming
Dim (+)
Dim (-)
Dim (+)
Dim (-)
Dim (-) - Gray
Return analog dimming
Specifications
Supply Voltage
Construction
Nominal voltage: 120 V ac to 277 V ac, 60 Hz in North America
Nominal voltage: 120 V ac to 277 V ac, 50/60 Hz outside North America
Power factor: > 0.95 at 120 V ac and > 0.90 at 277 V ac
Total harmonic distortion (THD): < 20%
Galvanized steel with corrosion resistant polyester powder coat,
polycarbonate window and end caps.
Weight: 2.8 kg (6.25 lbs)
Mounting
See electrical characteristics on product label
Compatible with a variety of common mounting and hanging methods.
Housing includes six mounting holes for surface mounting.
Several optional mounting brackets are available (see Accessories)
Supply Current
Max.
Current
Typical Current Draw (A)
Connections
Lighted
Length
(mm)
1/2-inch trade size conduit knockout in nine locations
Draw (A) at
90 V ac
120 V ac
0.43
230 V ac
0.22
277 V ac
0.18
Weight
2.8 kg (6.2 lbs)
1200
0.850
Environmental Rating
IEC IP20
Supply Protection Circuitry
Operating Temperature
Protected against transient voltages
Surface Mount Installation: –40 °C to +50 °C (–40 °F to +122 °F)
85% at +50 °C maximum relative humidity (non-condensing)
LED Lifetime
When operating within specifications, output will decrease less than 30%
after 50,000 hours.
Light Characteristics
Storage Temperature
Daylight White Efficacy: 130 lumens/watt typical at 120 V ac at 25 °C (77 °F)
CRI: 82, typical
–40 °C to +70 °C (–40 °F to +158 °F)
Vibration and Mechanical Shock
Vibration: 10 Hz to 55 Hz, 0.5 mm peak-to-peak amplitude per IEC
60068-2-6 (5 minute sweep, 30 minute dwell)
Shock: 5G 11 ms duration, half sine wave per IEC 60068-2-27
Impact: IK07 (IEC 60068-2-75)
Color
Color Temperature (CCT)
5000 K ( 300 K)
Lumens (Typical at 25 °C)
6800
Daylight White
P/N 210184 Rev. A
www.bannerengineering.com - Tel: + 1 888 373 6767
3
WLB72B Industrial LED Light Bar (AC)
Dimming
Compatible with 0–10 V analog LED dimming, dimmable to 5% intensity
Shielded wiring required for dimming control.
Required Overcurrent Protection
WARNING: Electrical connections must be
made by qualified personnel in accordance with
local and national electrical codes and
regulations.
Application Notes
When connecting continuous run/cascadable lights in series, it is important
not to exceed maximum current limitations of 14 AWG, 75 °C wire, in
accordance with the National Electrical Code (NEC) and any applicable local
code requirements.
Overcurrent protection is required to be provided by end product
application per the supplied table.
Two or more lights installed in parallel must maintain a 150 mm (6 inch)
spacing to maintain a 50 °C operating temperature.
Overcurrent protection may be provided with external fusing or via Current
Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to www.bannerengineering.com.
Certifications and Approvals
Supply Wiring (AWG)
Required Overcurrent Protection (Amps)
20
22
24
26
28
30
5.0
3.0
2.0
1.0
0.8
0.5
UL/cULus E470122
Performance Curves
Illuminance at a Distance
Isolux Pattern
Polar Candela Distribution
2
1
1
2
0 m
2
1
180°
170°
160°
2000
1667
1333
1000
667
Center Beam (lux)
7935 lux
1984 lux
882 lux
Beam Width (m)
1.4 m 2.1 m
2.8 m 4.3 m
4.2 m 6.4 m
5.6 m 8.6 m
6.9 m 10.7 m
8.3 m 12.8 m
150°
140°
130°
0.5 m
1.0 m
1.5 m
2.0 m
120°
110°
100°
496 lux
333
317 lux
0
90°
80°
0 m
2.5 m
3.0 m
333
220 lux
667
70°
60°
50°
40°
Vert.
Horiz.
1000
1333
1667
2000
Vertical Spread: 108.5°
Horizontal Spread: 129.9°
1
2
30°
20°
10°
0°
Vertical Angle:
0° Vertical 90° Horizontal
Mount height of 3 meters (3 m)
200 lux
175 lux
150 lux
125 lux
100 lux
75 lux
50 lux
25 lux
Illuminance at a Distance
Dimensions
All measurements are listed in millimeters, unless noted otherwise.
81.6
[3.21]
72.0
[2.83]
1221.7
[48.10]
9X Ø 22.23
[0.88]
KNOCKOUT
Bracket Mounting Holes
(SMBWLB72F)
951.7
[37.47]
6X Ø 6.35 Hanging Bracket
[0.25]
Mounting Holes
45.0
[1.77]
1021.7
[40.22]
4X M5 x 0.8
PEM
NUT
4
www.bannerengineering.com - Tel: + 1 888 373 6767
P/N 210184 Rev. A
WLB72B Industrial LED Light Bar (AC)
Accessories
Brackets
All measurements are listed in millimeters, unless noted otherwise.
LMBWLB72F
LMBWLB72HK
TILT RANGE 60º
25.4
•
•
Stainless steel
•
Hanging bracket kit allows for suspended
150
LOOSEN
TO ADJUST
OR TO TILT
LIGHT
60º
4 x Ø7
installation
Includes two surface mount brackets and
four screws for mounting onto the
housing
124.6
9.7
•
•
Includes two hanging bracket assemblies
Cables allow for 60 degrees of angle
adjustment
40
LMBWLB72RAS
•
Swivel brackets allow for 180° of
79
70
movement in seven fixed positions
•
•
Stainless steel
Includes two swivel bracket assemblies
and eight screws
2 x Ø7
60
25
Installing and Adjusting the WLB72 Hanging Bracket
To install the hanging bracket, assemble the bracket components as shown.
1. Hanging cable (2)
2. Gripper
2a. Plunger
1
2b. Cross cable nut
3. Cross cable (2)
4. Bracket (2)
LOOSEN
TO ADJUST
OR TO TILT
LIGHT
A
B
2a
2
2b
3
4
When feeding the cable through the gripper, allow at least one inch of cable beyond the gripper. Do not feed any excess cable into
the light housing. To adjust the gripper position:
1. Lift all weight off the gripper.
2. Press the plunger to release the cable.
3. Slide the gripper to a new position.
4. Release the plunger.
5. Tighten the cross cable nut manually.
P/N 210184 Rev. A
www.bannerengineering.com - Tel: + 1 888 373 6767
5
WLB72B Industrial LED Light Bar (AC)
Other Accessories
EBATTWLB72 Emergency LED Driver (Battery) Kit
When AC power fails, the emergency driver will provide 90 minutes of emergency light. When the AC power
is restored, the emergency driver automatically returns to the charge mode.
•
•
•
•
•
•
The kit includes everything needed to install battery inside the WLB72 housing
Smart charger for low energy consumption
Class 2 output, UL 1310 certified, CSA 22.2 No. 223-91 compliant
Meets CEC Title 20 (California Energy Commission) standards
Maintenance free Nickel-Cadmium battery, 7 to 10 year life expectancy
Includes illuminated battery test switch
ACC-WLB72-CSR-5 Cord Grip Accessory (5 pack with nuts)
•
•
•
•
•
•
•
One strain relief is included with each WLB72 light
Cable diameter: 4.3 mm to 11.4 mm (0.17 in to 0.45 in)
For use in clearance holes 22.2 mm (0.875 in) or threaded holes ½ NPT
Nylon 6/6 construction with TPE sealing gland resists common solvents
IEC IP68 rated (70 psi, 5 Bar)
Flammability Rating 94V-2
Temperature: –40 °C to 115 °C (–40 °F to 239 °F)
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for five years on daylight white and warm white models and one year on all other
models following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is
found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner
product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO
BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES
RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT,
STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously
manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the
product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will
void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at
any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to:
www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.
FCC Part 15 and CAN ICES-3 (B)/NMB-3(B)
This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions:
1.
2.
This device may not cause harmful interference, and
This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the manufacturer.
Mexican Importer
Banner Engineering de Mèxico, S. de R.L. de C.V.
David Alfaro Siqueiros 103 Piso 2 Valle oriente
San Pedro Garza Garcia Nuevo Leòn, C. P. 66269
81 8363.2714
©
Banner Engineering Corp. All rights reserved
相关型号:
©2020 ICPDF网 联系我们和版权申明