PFCVA-34X25-E [BANNER]

D10 Expert Series - Small Object Counter;
PFCVA-34X25-E
型号: PFCVA-34X25-E
厂家: Banner Engineering    Banner Engineering
描述:

D10 Expert Series - Small Object Counter

文件: 总9页 (文件大小:677K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DF-G2 High Speed Expert Dual Display  
Small Object Counter  
Quick Start Guide  
Advanced sensor with dual digital displays for small object counting applications  
For complete technical information about this product, including dimensions, accessories, and specifications, see http://  
www.bannerengineering.com and search 178236.  
WARNING: Not To Be Used for Personnel Protection  
Never use this device as a sensing device for personnel protection. Doing so could lead to  
serious injury or death. This device does not include the self-checking redundant circuitry necessary  
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an  
energized or de-energized sensor output condition.  
Overview  
1
2
3
4
5
6
7
Output LED  
LO/DO Switch  
RUN/PRG/ADJ Mode Switch  
Lever Action Fiber Clamp  
Red Signal Level  
Green Threshold  
+/SET/- Rocker Button  
Figure 1. DF-G2 Model Features  
Models  
1
Connector  
Model  
Outputs  
DF-G2-NC-2M  
DF-G2-PC-2M  
DF-G2-NC-Q5  
DF-G2-PC-Q5  
DF-G2-NC-Q7  
DF-G2-PC-Q7  
Single NPN, plus Health Mode output  
Single PNP, plus Health Mode output  
Single NPN, plus Health Mode output  
Single PNP, plus Health Mode output  
Single NPN, plus Health Mode output  
Single PNP, plus Health Mode output  
2 m (6.5 ft) cable, 5-wire  
150 mm (6 in) PVC cable with a 5-pin M12/Euro-style quick  
disconnect  
Integral 5-pin M8/Pico-style quick disconnect  
1
Connector options:  
A model with a QD connector requires a mating cordset  
For 9 m cable, change the suffix 2M to 9M in the 2 m model number (example, DF-G2-NC-9M)  
For 150 mm (6 in) PVC cable with a 5-pin M8/Pico-style QD model, change the suffix 2M to Q3 in the 2 m model number  
(example, DF-G2-NC-Q3)  
For Q3 and Q7 models, use a 5-pin M8/Pico-style or a 6-pin M8/Pico-style mating cordset  
Original Document  
178061 Rev. E  
9 September 2015  
178061  
DF-G2 High Speed Expert Dual Display Small Object Counter  
Fiber Optic Arrays  
Detection Window  
Dimensions  
2
3
Models  
Fiber Exit  
Side exit  
Minimum Object Size  
PFCVA-10X25-S  
PFCVA-10X25-E  
PFCVA-25X25-S  
PFCVA-25X25-E  
PFCVA-34X25-S  
PFCVA-34X25-E  
10 mm x 25 mm  
25 mm x 25 mm  
34 mm x 25 mm  
1.5 mm  
End exit  
Side exit  
End exit  
Side exit  
End exit  
3 mm  
4 mm  
Installation Instructions  
Mounting Instructions  
Mount on a DIN Rail  
1. Hook the DIN rail clip on the bottom of the DF-G2  
over the edge of the DIN rail (1).  
2. Push the DF-G2 up on the DIN rail (1).  
3. Pivot the DF-G2 onto the DIN rail, pressing until it  
snaps into place (2).  
Mount to the Accessory Bracket  
1. Position the DF-G2 in the SA-DIN-BRACKET.  
2. Insert the supplied M3 screws.  
3. Tighten the screws.  
Remove from a DIN rail  
1. Push the DF-G2 up on the DIN rail (1).  
2. Pivot the DF-G2 away from the DIN rail and remove  
it (2).  
2
Custom fiber arrays and mounting configurations are possible. Consult factory for assistance with your small object counting  
application.  
With 2% threshold offset percentage  
3
2
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 178061 Rev. E  
DF-G2 High Speed Expert Dual Display Small Object Counter  
Installing the Fibers  
Move forward  
to release the  
fibers  
Follow these steps to install glass or plastic fibers.  
1. Open the dust cover.  
Fiber Clamp  
2. Move the fiber clamp forward to unlock it.  
3. Insert the fiber(s) into the fiber port(s) until they  
stop.  
4. Move the fiber clamp backward to lock the fiber(s).  
5. Close the dust cover.  
Fiber Receiver  
Port  
Fiber Emitter  
Port  
Fiber Adapters  
NOTE: If a thin fiber with less than 2.2 mm outer diameter is used, install the fiber adapter provided  
with the fiber assembly to ensure a reliable fit in the fiber holder. Banner includes the adapters with all  
fiber assemblies.  
TO  
FIBERS  
TO  
SENSOR  
Fiber Outer Diameter (mm)  
Adapter Color  
Black  
Ø 1.0  
Ø 1.3  
Ø 2.2  
Red  
No adapter needed  
When connecting coaxial-type fiber assemblies to the amplifier, install the single-core fiber to the Transmitter port, and the  
multi-core fiber to the Receiver port. This will result in the most reliable detection.  
RECEIVER  
Multi-core fiber  
Single-core fiber  
TRANSMITTER  
P/N 178061 Rev. E  
www.bannerengineering.com - Tel: +1-763-544-3164  
3
DF-G2 High Speed Expert Dual Display Small Object Counter  
Wiring Diagrams  
PNP Models  
NPN Models  
Key  
1
3
1
4
2
1 = Brown  
2 = White  
3 = Blue  
4 = Black  
5 = Gray  
+
10-30V dc  
+
10–30 V dc  
3
4
Load  
Load  
(6 = no connection)  
2
Health  
Health  
5
5
Remote  
Remote  
Programming  
(N.O.)  
Programming  
(N.O.)  
NOTE: Open lead wires must be connected to a terminal block.  
Top Panel Interface  
Opening the dust cover provides access to the top panel interface. The top panel interface consists of the RUN/PRG/ADJ  
mode switch, LO/DO switch, +/SET/- rocker button, dual red/green digital displays, and output LED.  
RUN/PRG/ADJ Mode Switch  
The RUN/PRG/ADJ mode switch puts the sensor in RUN, PRG (Program), or ADJ (Adjust) mode. RUN  
mode allows the sensor to operate normally and prevents unintentional programming changes via the  
+/SET/- rocker button. PRG mode allows the sensor to be programmed through the display-driven  
programming menu (see Program Mode below). ADJ mode allows the user to perform Expert  
TEACH/SET methods and Manual Adjust (see Adjust Mode below).  
LO/DO Switch  
The LO/DO switch selects Light Operate or Dark Operate mode. In Light Operate mode, the output is  
ON when the sensing condition is above the threshold. (For Window SET, the output is ON when the  
sensing condition is inside the window.) In Dark Operate mode, the output is ON when the sensing  
condition is below the threshold. (For Window SET, the output is ON when the sensing condition is  
outside the window.)  
+/SET/- Rocker Button  
The +/SET/- rocker button is a 3-way button. The +/- positions are engaged by rocking the button left/  
right. The SET position is engaged by clicking down the button while the rocker is in the middle position.  
All three button positions are used during PRG mode to navigate the display-driven programming menu.  
During ADJ mode, SET is used to perform TEACH/SET methods. The rocker button is disabled during  
RUN mode, except when using Window SET, see Window SET on page 6.  
Red/Green Digital Displays  
During RUN and ADJ modes, the Red display shows the signal level, and the Green display shows the  
threshold or the total counts. During PRG mode, both displays are used to navigate the display-driven  
programming menu.  
Output LED  
The output LED provides a visible indication when the output is activated.  
4
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 178061 Rev. E  
DF-G2 High Speed Expert Dual Display Small Object Counter  
Operating Instructions  
Remote Input  
For more information about how to perform TEACH/SET methods and to program the sensor remotely, see  
www.bannerengineering.com and search 178236.  
Run Mode  
Run mode allows the sensor to operate normally and prevents unintentional programming changes. The +/SET/- rocker  
button is disabled during RUN mode, except when using Window SET, see Window SET on page 6.  
In RUN Mode, the SET function of the +/SET/- rocker button allows the user to toggle between the threshold center value  
and the total number of counts on the Green display. If the Totalizer function is enabled, the total counts value increments  
to the programmed value and then starts over at 0. If the Totalizer function is disabled, the total counts value increments  
to 9999 and then starts over at 0. Changing any operational setting causes the total counts value to reset to 0.  
Program Mode  
PROGRAM MODE  
Mode Switch  
to “PRG”  
To scroll through menu lists: Press “+” or “-”  
To enter a choice list or to select and save: Click SET  
To exit a choice list without saving: Press and hold SET for 2 seconds  
SET  
-
+
rocker button  
Menu  
List  
Click SET  
Click SET  
Click SET  
Click SET  
Click SET  
Click SET  
Click SET  
Click SET  
to enter choice list  
to enter choice list  
to enter choice list  
to enter choice list  
to enter choice list  
to enter choice list  
to enter choice list  
to enter choice list  
DISPLAY  
LOOP  
DISPLAY  
LOOP  
DISPLAY  
LOOP  
DISPLAY  
LOOP  
(+) or (-)  
to set value  
(+) or (-)  
(+) or (-)  
(+) or (-)  
to set value  
to set value  
to set value  
(display flips 180˚)  
Click SET to select and save a choice in any list  
Return to Menu List  
on display represents a “w”  
on display represents a “m”  
Figure 2.  
Program (PRG) mode allows the following settings to be programmed in the DF-G2  
P/N 178061 Rev. E  
www.bannerengineering.com - Tel: +1-763-544-3164  
5
DF-G2 High Speed Expert Dual Display Small Object Counter  
Factory Default Settings:  
Setting  
Factory Default  
Threshold  
3700 (typical)  
TEACH Selection  
Response Speed  
Offset Percent  
Window SET  
Standard: 250 µs  
2%  
Totalizer Counts  
Totalizer One-Shot  
Dynamic Event Stretcher  
Display Readout  
OFF  
OFF  
50%  
Numeric, ECO disabled, Normal Orientation  
Adjust Mode  
Sliding the RUN/PRG/ADJ mode switch to the ADJ position allows the user to perform Expert TEACH/SET methods.  
TEACH Procedures  
The instruction manual has detailed instructions for these TEACH modes:  
Window SET  
Light SET  
Dynamic TEACH  
Window SET  
Sets window thresholds that extend a programmable % offset above and below the presented condition  
All other conditions (lighter or darker) cause the output to change state  
Recommended for applications where a product may not always appear in the same place, or when other signals  
may appear  
See Program Mode in the user's manual for programming the Offset Percent setting (to increase/decrease the  
window size)  
A single sensing condition is presented, and the sensor positions window thresholds a programmable % offset above and  
below the presented condition. In LO mode, Window SET designates a sensing window with the Output ON condition inside  
the window, and the Output OFF conditions outside the window.  
Sensing Window  
Sensor positions  
window thresholds  
a programmable %  
offset from the  
presented condition  
Output OFF  
Output ON  
Output OFF  
Darkest  
(no signal)  
Condition  
Presented  
Most Light  
(saturated  
signal)  
Figure 3. Window SET (Light Operate shown)  
Output ON and OFF conditions can be reversed using the LO/DO switch.  
Light SET  
Sets a threshold a programmable % offset below the presented condition  
Changes output state on any condition darker than the threshold condition  
Recommended for applications where only one condition is known, for example a stable light background with  
varying darker targets  
See Program Mode on page 5 for programming the Offset Percent setting  
6
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 178061 Rev. E  
DF-G2 High Speed Expert Dual Display Small Object Counter  
A single sensing condition is presented, and the sensor positions a threshold a programmable % offset below the  
presented condition. When a condition darker than the threshold is sensed, the output either turns ON or OFF, depending  
on the LO/DO setting.  
Threshold Position  
Sensor positions  
threshold a programmable  
% offset below the  
presented condition  
Output OFF  
Output ON  
Darkest  
(no signal)  
Most Light  
(saturated  
signal)  
Condition  
Presented  
Figure 4. Light SET (Light Operate shown)  
Dynamic TEACH  
Teaches on-the-fly  
Establishes a single switching threshold  
Dynamic TEACH is best used when a machine or process may not be stopped for teaching. The sensor learns during actual  
sensing conditions, taking multiple samples of the light and dark conditions and automatically setting the threshold at the  
optimum level.  
Darkest Taught  
Condition  
Lightest Taught  
Condition  
Sensor positions  
threshold midway  
between taught conditions  
Output OFF  
Output ON  
Darkest  
(no signal)  
Most Light  
(saturated  
signal)  
Position  
Figure 5. Dynamic TEACH (Light Operate shown)  
The output ON and OFF conditions can be reversed using the LO/DO switch.  
Troubleshooting  
Percent Minimum Difference after TEACH  
The Dynamic TEACH method will flash a % minimum difference on the displays after a PASS or FAIL.  
Value  
PASS/FAIL  
FAIL  
Description  
0 to 99%  
The difference of the taught conditions does not meet the required minimum  
100 to 300%  
PASS  
The difference of the taught conditions just meets/exceeds the required minimum,  
minor sensing variables may affect sensing reliability  
300 to 600%  
600% +  
PASS  
PASS  
The difference of the taught conditions sufficiently exceeds the required minimum,  
minor sensing variables will not affect sensing reliability  
The difference of the taught conditions greatly exceeds the required minimum, very  
stable operation  
Percent Offset after SET  
The Window and Light SET methods will flash a % offset on the displays after a PASS or FAIL.  
P/N 178061 Rev. E  
www.bannerengineering.com - Tel: +1-763-544-3164  
7
DF-G2 High Speed Expert Dual Display Small Object Counter  
SET Result  
% Offset Meaning  
PASS (with % Offset)  
FAIL (with % Offset)  
FAIL (without % Offset)  
Displays the % offset used for the SET method  
Displays the minimum required % offset necessary to PASS the SET method  
Presented condition cannot be used for the SET method  
Health Mode Alarm  
The Health Mode Alarm alerts you when preventative maintenance becomes necessary to ensure reliable sensing. The  
Health Mode output 2 is Active when the system is OK and operating normally. Health Mode output 2 becomes Inactive  
when the system is in a marginal state because of contamination. The system still operates normally and can detect small  
objects, but is nearing the alarm state. When the system is completely contaminated and unable to ensure reliable  
sensing, the system goes into the alarm state. In the alarm state, the discrete output 1 is forced to the blocked state and  
can no longer be used to detect small objects.  
Threshold Alert  
system operates normally but is nearing the alarm state.  
displays when Health Mode output 2 is inactive because of contamination. The  
Threshold Error  
used to detect small objects.  
displays when discrete output 1 is forced to the blocked state and can no longer be  
The sensor may enter Health Mode Alarm for any of these reasons:  
1. When first powered up; the fiber optic array may already be contaminated  
2. If the Window SET procedure fails, indicating the fiber optic array is contaminated and the sensor could not set a  
valid clear-state light level for reliable detection  
3. If the fiber optic array is contaminated enough that the auto compensation tracking algorithm cannot sufficiently  
adjust the thresholds to ensure reliable detection  
4. If the fiber optic array is blocked for more than 2 seconds  
Return the system to normal operation by cleaning the fiber optic array and performing a Window SET to reset the clear-  
state light level (see Window SET on page 6).  
Specifications  
Sensing Beam  
Output Response Time  
Visible red, 635 nm  
25 µs  
50 µs  
Supply Voltage  
150 µs  
250 µs  
500 µs  
10 to 30 V dc Class 2 (10% maximum ripple)  
Power and Current Consumption (exclusive of load)  
Standard display mode: 960 mW, Current consumption < 40 mA at 24  
V dc  
Repeatability  
12 µs  
ECO display mode: 720 mW, Current consumption < 30 mA at 24 V dc  
12 µs  
30 µs  
50 µs  
80 µs  
Supply Protection Circuitry  
Protected against reverse polarity and transient overvoltages  
Delay at Power-Up  
500 milliseconds maximum; outputs do not conduct during this time  
Connections  
Output Configuration  
PVC-jacketed 2 m or 9 m (6.5 ft or 30 ft) 5-wire integral cable; or  
integral 5-pin M8/Pico-style quick disconnect; or 150 mm (6 in) cable  
with a 5-pin M12/Euro-style quick disconnect; or 150 mm (6 in)  
cable with a 5-pin M8/Pico-style quick disconnect  
For Q3 or Q7 5-pin models, either a 5-pin M8/Pico-style or a 6-pin  
M8/Pico-style mating cordset may be used  
1 current sinking (NPN) or 1 current sourcing (PNP) output, depending on  
model, plus 1 Health Mode output  
Output Rating  
100 mA maximum combined load (derate 1 mA per °C above 30 °C)  
OFF-state leakage current: < 5 μA at 30 V dc;  
ON-state saturation voltage: NPN: < 1.5 V; PNP : < 2 V  
Construction  
Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear  
polycarbonate cover  
Output Protection  
Protected against output short-circuit, continuous overload, transient  
overvoltages, and false pulse on power-up  
Environmental Rating  
IEC IEC IP50, NEMA 1  
Operating Conditions  
Temperature: 10 °C to +55 °C (+14 °F to +131 °F)  
Storage Temperature: 20 °C to +85 °C (4 °F to +185 °F)  
Humidity: 90% at +60 °C maximum relative humidity (non-  
condensing)  
8
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 178061 Rev. E  
DF-G2 High Speed Expert Dual Display Small Object Counter  
Required Overcurrent Protection  
WARNING: Electrical connections must be  
Certifications  
Industrial  
Control  
Equipment  
made by qualified personnel in accordance  
with local and national electrical codes and  
regulations.  
3TJJ  
Overcurrent protection is required to be provided by end product  
application per the supplied table.  
Overcurrent protection may be provided with external fusing or via  
Current Limiting, Class 2 Power Supply.  
Supply wiring leads < 24 AWG shall not be spliced.  
For additional product support, go to http://www.bannerengineering.com.  
Supply Wiring  
Required Overcurrent Protection  
20  
22  
24  
26  
28  
30  
5.0 Amps  
3.0 Amps  
2.0 Amps  
1.0 Amps  
0.8 Amps  
0.5 Amps  
Banner Engineering Corp. Limited Warranty  
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp.  
will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty  
period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.  
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION,  
ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE  
OF DEALING OR TRADE USAGE.  
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE  
LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL,  
CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER  
ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.  
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product  
previously manufactured by Banner Engineering Corp.  
www.bannerengineering.com - Tel: +1-763-544-3164  

相关型号:

PFCVA-34X25-S

D10 Expert Series - Small Object Counter
BANNER

PFD.1B.306.CYZZ

CONN HSG RCPT 6POS JAM NUT SKT
ETC

PFD0753-4BH-TN

DC-DC Regulated Power Supply Module, 4 Output, 750W, LOW PROFILE MODULE
INFINEON

PFD0753-4BH-ZN

DC-DC Regulated Power Supply Module, 4 Output, 750W, LOW PROFILE MODULE
INFINEON

PFD0753-4BH-ZT

DC-DC Regulated Power Supply Module, 4 Output, 750W, LOW PROFILE MODULE
INFINEON

PFD0753-4CH-TN

DC-DC Regulated Power Supply Module, 4 Output, 750W, LOW PROFILE MODULE
INFINEON

PFD0753-4CH-TT

DC-DC Regulated Power Supply Module, 4 Output, 750W, LOW PROFILE MODULE
INFINEON

PFD0753-4CH-ZN

DC-DC Regulated Power Supply Module, 4 Output, 750W, LOW PROFILE MODULE
INFINEON

PFD0753-4CH-ZT

DC-DC Regulated Power Supply Module, 4 Output, 750W, LOW PROFILE MODULE
INFINEON

PFD0753-4DH-TN

DC-DC Regulated Power Supply Module, 4 Output, 750W, LOW PROFILE MODULE
INFINEON

PFD0753-4DH-TT

DC-DC Regulated Power Supply Module, 4 Output, 750W, LOW PROFILE MODULE
INFINEON

PFD0753-4EH-TN

DC-DC Regulated Power Supply Module, 4 Output, 750W, LOW PROFILE MODULE
INFINEON